1.
J Clin Med ; 13(10)2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38792411

RESUMEN

Background: Centrifugal-flow left ventricular assist devices (CF-LVADs) have improved morbidity and mortality for their recipients. Hospital readmissions remain common, negatively impacting quality of life and survival. We sought to identify risk factors associated with hospital readmissions among patients with CF-LVADs. Methods: Consecutive patients receiving a CF-LVAD between February 2011 and March 2021 were retrospectively evaluated using prospectively maintained institutional databases. Hospital readmissions within three years post-LVAD implantation were dichotomized into heart failure (HF)/LVAD-related or non-HF/LVAD-related readmissions. Multivariable Cox regression models augmented using a machine learning algorithm, the least absolute shrinkage and selection operator (LASSO) method, for variable selection were used to estimate associations between HF/LVAD-related readmissions and pre-, intra- and post-operative clinical variables. Results: A total of 204 CF-LVAD recipients were included, of which 138 (67.7%) had at least one HF/LVAD-related readmission. HF/LVAD-related readmissions accounted for 74.4% (436/586) of total readmissions. The main reasons for HF/LVAD-related readmissions were major bleeding, major infection, HF exacerbation, and neurological dysfunction. Using pre-LVAD variables, HF/LVAD-related readmissions were associated with substance use, previous cardiac surgery, HF duration, pre-LVAD inotrope dependence, percutaneous LVAD/VA-ECMO support, LVAD type, and the left ventricular ejection fraction in multivariable analysis (Harrell's concordance c-statistic; 0.629). After adding intra- and post-operative variables in the multivariable model, LVAD implant hospitalization length of stay was an additional predictor of readmission. Conclusions: Using machine learning-based techniques, we generated models identifying pre-, intra-, and post-operative variables associated with a higher likelihood of rehospitalizations among patients on CF-LVAD support. These models could provide guidance in identifying patients with increased readmission risk for whom clinical strategies to mitigate this risk may further improve LVAD recipient outcomes.

2.
Clin Transplant ; 38(5): e15330, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38716787

RESUMEN

INTRODUCTION: Since the 2018 change in the US adult heart allocation policy, more patients are bridged-to-transplant on temporary mechanical circulatory support (tMCS). Previous studies indicate that durable left ventricular assist devices (LVAD) may lead to allosensitization. The goal of this study was to assess whether tMCS implantation is associated with changes in sensitization. METHODS: We included patients evaluated for heart transplants between 2015 and 2022 who had alloantibody measured before and after MCS implantation. Allosensitization was defined as development of new alloantibodies after tMCS implant. RESULTS: A total of 41 patients received tMCS before transplant. Nine (22.0%) patients developed alloantibodies following tMCS implantation: 3 (12.0%) in the intra-aortic balloon pump group (n = 25), 2 (28.6%) in the microaxial percutaneous LVAD group (n = 7), and 4 (44.4%) in the veno-arterial extra-corporeal membrane oxygenation group (n = 9)-p = .039. Sensitized patients were younger (44.7 ± 11.6 years vs. 54.3 ± 12.5 years, p = .044), were more likely to be sensitized at baseline - 3 of 9 (33.3%) compared to 2 out of 32 (6.3%) (p = .028) and received more transfusions with red blood cells (6 (66.6%) vs. 8 (25%), p = .02) and platelets (6 (66.6%) vs. 5 (15.6%), p = .002). There was no significant difference in tMCS median duration of support (4 [3,15] days vs. 8.5 [5,14.5] days, p = .57). Importantly, out of the 11 patients who received a durable LVAD after tMCS, 5 (45.5%) became sensitized, compared to 4 out of 30 patients (13.3%) who only had tMCS-p = .028. CONCLUSIONS: Our findings suggest that patients bridged-to-transplant with tMCS, without significant blood product transfusions and a subsequent durable LVAD implant, have a low risk of allosensitization. Further studies are needed to confirm our findings and determine whether risk of sensitization varies by type of tMCS and duration of support.


Asunto(s)
Trasplante de Corazón , Corazón Auxiliar , Isoanticuerpos , Humanos , Masculino , Femenino , Persona de Mediana Edad , Isoanticuerpos/inmunología , Isoanticuerpos/sangre , Estudios de Seguimiento , Adulto , Factores de Riesgo , Pronóstico , Estudios Retrospectivos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/terapia , Rechazo de Injerto/etiología
3.
J Am Med Inform Assoc ; 31(4): 919-928, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38341800

RESUMEN

OBJECTIVES: We conducted an implementation planning process during the pilot phase of a pragmatic trial, which tests an intervention guided by artificial intelligence (AI) analytics sourced from noninvasive monitoring data in heart failure patients (LINK-HF2). MATERIALS AND METHODS: A mixed-method analysis was conducted at 2 pilot sites. Interviews were conducted with 12 of 27 enrolled patients and with 13 participating clinicians. iPARIHS constructs were used for interview construction to identify workflow, communication patterns, and clinician's beliefs. Interviews were transcribed and analyzed using inductive coding protocols to identify key themes. Behavioral response data from the AI-generated notifications were collected. RESULTS: Clinicians responded to notifications within 24 hours in 95% of instances, with 26.7% resulting in clinical action. Four implementation themes emerged: (1) High anticipatory expectations for reliable patient communications, reduced patient burden, and less proactive provider monitoring. (2) The AI notifications required a differential and tailored balance of trust and action advice related to role. (3) Clinic experience with other home-based programs influenced utilization. (4) Responding to notifications involved significant effort, including electronic health record (EHR) review, patient contact, and consultation with other clinicians. DISCUSSION: Clinician's use of AI data is a function of beliefs regarding the trustworthiness and usefulness of the data, the degree of autonomy in professional roles, and the cognitive effort involved. CONCLUSION: The implementation planning analysis guided development of strategies that addressed communication technology, patient education, and EHR integration to reduce clinician and patient burden in the subsequent main randomized phase of the trial. Our results provide important insights into the unique implications of implementing AI analytics into clinical workflow.


Asunto(s)
Inteligencia Artificial , Insuficiencia Cardíaca , Humanos , Instituciones de Atención Ambulatoria , Comunicación , Insuficiencia Cardíaca/terapia , Tecnología de la Información
4.
JAMA Cardiol ; 9(3): 272-282, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38294795

RESUMEN

Importance: The existing models predicting right ventricular failure (RVF) after durable left ventricular assist device (LVAD) support might be limited, partly due to lack of external validation, marginal predictive power, and absence of intraoperative characteristics. Objective: To derive and validate a risk model to predict RVF after LVAD implantation. Design, Setting, and Participants: This was a hybrid prospective-retrospective multicenter cohort study conducted from April 2008 to July 2019 of patients with advanced heart failure (HF) requiring continuous-flow LVAD. The derivation cohort included patients enrolled at 5 institutions. The external validation cohort included patients enrolled at a sixth institution within the same period. Study data were analyzed October 2022 to August 2023. Exposures: Study participants underwent chronic continuous-flow LVAD support. Main Outcome and Measures: The primary outcome was RVF incidence, defined as the need for RV assist device or intravenous inotropes for greater than 14 days. Bootstrap imputation and adaptive least absolute shrinkage and selection operator variable selection techniques were used to derive a predictive model. An RVF risk calculator (STOP-RVF) was then developed and subsequently externally validated, which can provide personalized quantification of the risk for LVAD candidates. Its predictive accuracy was compared with previously published RVF scores. Results: The derivation cohort included 798 patients (mean [SE] age, 56.1 [13.2] years; 668 male [83.7%]). The external validation cohort included 327 patients. RVF developed in 193 of 798 patients (24.2%) in the derivation cohort and 107 of 327 patients (32.7%) in the validation cohort. Preimplant variables associated with postoperative RVF included nonischemic cardiomyopathy, intra-aortic balloon pump, microaxial percutaneous left ventricular assist device/venoarterial extracorporeal membrane oxygenation, LVAD configuration, Interagency Registry for Mechanically Assisted Circulatory Support profiles 1 to 2, right atrial/pulmonary capillary wedge pressure ratio, use of angiotensin-converting enzyme inhibitors, platelet count, and serum sodium, albumin, and creatinine levels. Inclusion of intraoperative characteristics did not improve model performance. The calculator achieved a C statistic of 0.75 (95% CI, 0.71-0.79) in the derivation cohort and 0.73 (95% CI, 0.67-0.80) in the validation cohort. Cumulative survival was higher in patients composing the low-risk group (estimated <20% RVF risk) compared with those in the higher-risk groups. The STOP-RVF risk calculator exhibited a significantly better performance than commonly used risk scores proposed by Kormos et al (C statistic, 0.58; 95% CI, 0.53-0.63) and Drakos et al (C statistic, 0.62; 95% CI, 0.57-0.67). Conclusions and Relevance: Implementing routine clinical data, this multicenter cohort study derived and validated the STOP-RVF calculator as a personalized risk assessment tool for the prediction of RVF and RVF-associated all-cause mortality.


Asunto(s)
Sistema Cardiovascular , Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Masculino , Persona de Mediana Edad , Estudios de Cohortes , Corazón Auxiliar/efectos adversos , Estudios Prospectivos , Factores de Riesgo , Femenino , Adulto , Anciano
5.
J Heart Lung Transplant ; 42(7): 853-858, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37086251

RESUMEN

By unloading the failing heart, left ventricular (LV) assist devices (LVADs) provide a favorable environment for reversing adverse structural and functional cardiac changes. Prior reports have suggested that an improved native LV function might contribute to the development of LVAD thrombosis. We used the Interagency Registry for Mechanically Assisted Circulatory Support and found that LV functional improvement is associated with a lower risk for device thrombosis. The risk for cerebrovascular accident and transient ischemic attack was comparable across post-LVAD LV function subgroups, while the risk of hemolysis was lower in subgroups of patients with better LV function on LVAD support.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Trombosis , Humanos , Corazón , Ventrículos Cardíacos , Función Ventricular Izquierda , Trombosis/etiología , Corazón Auxiliar/efectos adversos
7.
J Interv Card Electrophysiol ; 66(2): 471-481, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36063282

RESUMEN

BACKGROUND: The strategy of cardiac implantable electronic device (CIED) implantations performed as day-case admissions has gained a wider acceptance overtime; however, data on safety are still limited. This study aims to investigate the safety of a same-day discharge protocol introduced in our hospital for the postprocedural management of patients undergoing CIED implantation. METHODS: Α prospective, non-interventional, non-randomised study performed in a single high-volume implanting centre for a 16-month period (March 2020 to June 2021). At total of 821 of 965 (85.1%) patients scheduled for elective CIED implantation were considered to be eligible for inclusion in the Short-stay Device Management Protocol. These patients were compared with a historical group of 932 patients, meeting the same inclusion criteria. RESULTS: Procedure was successful in 812 patients (98.9%), committed to same-day discharge versus 921 of 932 patients (98.8%) admitted for overnight stay (p = 0.87). Overall, 90-day complication rate was comparable in both groups (4.14% vs 4.07%, p = 0.95), as was major (1.46% vs. 1.82%, p = 0.55) and minor (2.67% vs. 2.25%, p = 0.64) complication rates. The composite early post-procedural complication rates and late post-procedural complication rates were comparable among groups (0.97 vs 1.18%, p = 0.70 and 0.73% vs 0.64%, p = 0.83, respectively). Six hundred sixty-seven patients (84%) preferred the same-day discharge strategy. Finally, a reduction of 792 bed-days was recorded, resulting in possible financial Health System benefits. CONCLUSIONS: Same-day discharge is feasible and safe in the majority of patients referred for CIED implantation. Additionally, same-day discharge is preferred by patients and may reduce procedure-related costs due to significant bed-day reductions.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Alta del Paciente , Estudios Prospectivos , Hospitalización , Estudios Retrospectivos
8.
Cancers (Basel) ; 16(1)2023 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-38201522

RESUMEN

We conducted a single-center, non-interventional retrospective study of melanoma patients with COVID-19 (1 March 2020 until 17 March 2023). The cohort was further divided into three groups according to the periods of SARS-CoV-2 variant dominance in Greece. We recorded demographics, comorbidities, vaccination data, cancer diagnosis/stage, types of systemic melanoma treatments, date of COVID-19 diagnosis and survival. We identified 121 patients. The vast majority (87.6%) had advanced disease (stages III or IV). A total of 80.1% of the patients were receiving immune checkpoint inhibitor-based therapies, 92.5% had asymptomatic/mild COVID-19 and 7.4% had moderate/severe/critical disease, while 83.5% contracted COVID-19 during the third period of the pandemic. Sixteen patients (13.2%) were hospitalized for COVID-19 with a median length of stay of 12 days (range: 1-55 days). Advanced age, heart failure, number of comorbidities (≤1 vs. >1), vaccination status and the time period of the infection correlated with more severe COVID-19, whereas only heart failure and time period were independently correlated with severity. The 30-day mortality rate after COVID-19 was 4.2%. With a median follow-up of 340 days post-COVID-19, 17.4% of patients were deceased. In this cohort of melanoma patients with COVID-19, the 30-day mortality rate was low. There was no association between melanoma stage, treatment receipt and type of treatment with COVID-19 severity.

9.
Blood Press ; 31(1): 228-235, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36123788

RESUMEN

PURPOSE: We investigated whether blood pressure (BP) control measures, visit-to-visit BP variability, and time in therapeutic range (TTR) are associated with future cardiovascular outcomes in hypertensive patients. MATERIALS AND METHODS: Among 1,408 hypertensive patients without cardiovascular disease, we prospectively evaluated the incident major cardiovascular events over 6 years. In newly diagnosed patients, antihypertensive drug treatment was initiated. We estimated two markers of on-treatment BP control, (1) visit-to-visit BPV as the coefficient of variation of office systolic BP (BP-CV), and (2) TTR calculated as the percentage of office systolic BP measurements within 120-140mmHg across visits. RESULTS: The hypertensive cohort (672 males, mean age 60 years, 31% newly diagnosed) had a mean systolic/diastolic BP of 142/87 mmHg. The mean number of visits was 4.9 ± 2.6, while the mean attained systolic/diastolic BP during follow-up was 137/79 mmHg using 2.7 ± 1.1 antihypertensive drugs. The BP-CV and TTR were 9.1 ± 4.1% and 45 ± 29%, respectively, and the incidence of the composite outcome was 8.3% (n = 117). After adjustment for relevant confounders and standardization to z-scores, BP-CV and TTR were associated with a 43% (95% CI, 27-62%) increase and a 33% (95% CI, 15-47%) reduction in the outcome. However, the joint evaluation of TTR and BP-CV in a common multivariable model indicated that a standardized change of TTR was associated with the outcome to a greater extent than BP-CV (mean hazard ratios of 30% vs. 24%, respectively). When combined with the higher BP standardized-CV quartile, the lower TTR quartile predicted the outcome by 2.3 times (95% CI, 1.1-5.4) compared to the inverse TTR and BP-CV quartile pattern. CONCLUSION: High BP-CV or low TTR was associated with future cardiovascular events in a cohort of treated hypertensive patients. As a determinant, the extent of TTR value appears greater than BP-CV when these measures are considered in the same multivariable model.


Asunto(s)
Enfermedades Cardiovasculares , Hipertensión , Antihipertensivos/farmacología , Antihipertensivos/uso terapéutico , Presión Sanguínea , Enfermedades Cardiovasculares/etiología , Humanos , Hipertensión/complicaciones , Hipertensión/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo
10.
Artículo en Inglés | MEDLINE | ID: mdl-36018270

RESUMEN

OBJECTIVES: Calcified or fibrotic cusps in patients with bicuspid aortic valves and aortic regurgitation complicate successful aortic valve (AV)-repair. Aortic valve neocuspidization (AVNeo) with autologous pericardium offers an alternative treatment to prosthetic valve replacement. We compared patients with regurgitant bicuspid valves undergoing AV-repair or AVNeo. METHODS: We retrospectively analysed patients with regurgitant bicuspid valves undergoing AV-repair or AVNeo. We focused on residual regurgitation, pressure gradients and effective orifice area, determined preoperatively and at discharge. RESULTS: AV-repair was performed in 61 patients (mean age: 43.2 ± 11.3 years) and AVNeo in 22 (45.7 ± 14.1). Prior to the operation patients of the AV-repair group showed severe regurgitation in 38 cases (62.3%) and moderate in 23 (37.6%); in the AVNeo group, all patients exhibited severe regurgitation. Postoperatively, 57 patients (93.4%) patients had no or mild regurgitation after AV-repair and 21 (95.4%) after AVNeo. In AVNeo-patients, peak (10.6 ± 3.1 mmHg vs 22.7 ± 11 mmHg, P< 0.001) and mean pressure gradients (5.9 ± 2 mmHg vs 13.8 ± 7.3 mmHg, P < 0.001) were significantly lower and the orifice area significantly larger (2.9 ± 0.8 cm2 vs 1.9 ± 0.7 cm2, P < 0.001) compared to repair. CONCLUSIONS: Compared to AV-repair, patients AVNeo showed lower mean pressure gradients and larger orifice areas at discharge. The functional result was not different.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Humanos , Adulto , Persona de Mediana Edad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios Retrospectivos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Hemodinámica , Resultado del Tratamiento
11.
J Clin Med ; 11(12)2022 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-35743611

RESUMEN

Left ventricular assist devices (LVADs) are an established treatment modality for advanced heart failure (HF). It has been shown that through volume and pressure unloading they can lead to significant functional and structural cardiac improvement, allowing LVAD support withdrawal in a subset of patients. In the first part of this review, we discuss the historical background, current evidence on the incidence and assessment of LVAD-mediated cardiac recovery, and out-comes including quality of life after LVAD support withdrawal. In the second part, we discuss current and future opportunities to promote LVAD-mediated reverse remodeling and improve our pathophysiological understanding of HF and recovery for the benefit of the greater HF population.

12.
Eur J Cardiothorac Surg ; 62(5)2022 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-35396837

RESUMEN

OBJECTIVES: Minimally invasive mitral valve repair (MVR) promises major advantages over median sternotomy regarding cosmetic results and faster recovery. However, the long-term functional outcome of minimally invasive MVR has been questioned by critics because the limited access may not exclusively promise high-quality repair. This study examines the long-term outcome regarding survival and reoperation rate. METHODS: All patients undergoing minimally invasive MVR from February 2000 until March 2020 were included in this study. Baseline clinical and surgical characteristics were summarized from the internal database. Primary end points were survival and freedom from reoperation, analysed via Kaplan-Meier curves. Secondary end points were periprocedural complications after minimally invasive MVR and incidence for recurrent mitral regurgitation >II°. RESULTS: A total of 1194 patients underwent minimally invasive MVR, in 17 cases mitral valve replacement was required. The mean age was 55.1 years [47.6; 62.7]. The successful minimally invasive repair rate was 97%. The 30-day mortality was 0.6%. Survival was 96.7% [standard deviation (SD): 5.8%], 91.6% (SD: 1.1%) and 80.0% (SD: 11.2%) at 5, 10 and 20 years. The incidence of reoperation was 4.4% (SD: 3.2%), 10.3% (SD: 7.4%) and 16.7% (SD : 7.4%) at 5, 10 and 20 years, respectively. Concomitant procedures such as tricuspid valve repair and modified Cryo-maze procedure were performed in 263 cases. CONCLUSIONS: Minimally invasive MVR for degenerative mitral regurgitation is safe, shows excellent functional long-term results and is associated with low perioperative and late mortality.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Resultado del Tratamiento , Procedimientos Quirúrgicos Cardíacos/métodos , Esternotomía/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
13.
J Clin Med ; 11(6)2022 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-35330034

RESUMEN

BACKROUND: Mitral valve (MV) repair in the case of a large anterior-posterior diameter and redundant valve tissue remains challenging and favors repair with a ring that exhibits a large anterior-posterior diameter. Compared to other available rings, the Medtronic Simulus annuloplasty ring shows the largest anterior-posterior diameter. This study reports for the first time mid-term results using this annuloplasty ring. METHODS: Between 11/2015 and 12/2019, a total of 378 patients underwent MV repair for degenerative mitral regurgitation using the Medtronic Simulus ring, according to the following selection criteria: large MV annuli, abundant leaflet tissue (i.e., Barlow disease), and risk for SAM. RESULTS: Overall survival after 5 years was 90.8 ± 4.6%. Five patients required valve-related reoperations because of ring dehiscence (n = 1), progression of native valve disease (n = 2), dehiscence of quadrangular resection suture (n = 1), and endocarditis (n = 1). The cumulative incidence of valve-related reoperation at 5 years was 1.3 ± 0.5%. At latest follow-up, echocardiography demonstrated excellent valve function with no/mild MR in 299 patients (94.6%). Two patients (0.6%) had more than moderate MR. No patient developed SAM after repair. CONCLUSION: Repair of MV with large annuli and abundant leaflet tissue with the Medtronic Simulus annuloplasty ring shows excellent mid-term results regarding reoperation rates and recurrent MR.

16.
Hellenic J Cardiol ; 64: 77-86, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34843996

RESUMEN

His bundle pacing (HBP) is proven to be a safe and effective alternative pacing modality that, in addition, avoids pacemaker-induced cardiomyopathy (PICM) by achieving a "physiological" ventricular stimulation, via the native conduction system. Indications include various causes of bradycardia requiring anti-bradycardic pacing, inadequately controlled atrial fibrillation requiring AV node ablation and established PICM. In addition, HBP may also be used as an alternative therapy for patients with heart failure (HF) and an indication for cardiac resynchronization therapy (CRT). Available data show several advantages of HBP with regard to preservation or restoration of intra- and inter-ventricular synchronization; improvement in left ventricular ejection fraction, functional status and quality of life; decrease in atrial fibrillation incidence and improvement in HF hospitalization rates, compared with conventional pacing. Nevertheless, superiority in terms of mortality rates has not been consistently demonstrated, and the long-term efficacy and safety of HBP remain to be proven. In the present manuscript, we review the status of HBP and present our current experience with this novel pacing modality.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Fibrilación Atrial/terapia , Bradicardia/terapia , Fascículo Atrioventricular , Estimulación Cardíaca Artificial/efectos adversos , Electrocardiografía , Insuficiencia Cardíaca/terapia , Humanos , Calidad de Vida , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
17.
J Card Surg ; 36(12): 4537-4545, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34580919

RESUMEN

BACKGROUND: The dual-filter Sentinel™ Cerebral Protection System (Sentinel-CPS) is increasingly used during transcatheter aortic valve replacement (TAVR). However, complex vascular anatomy may challenge Sentinel-CPS deployment. AIM OF THE STUDY: We sought to investigate the impact of anatomic features of the aortic arch and the supra-aortic arteries on technical device failure of Sentinel-CPS application. METHODS: Analysis of the multislice computed tomography pre-TAVR aortograms of all patients undergoing TAVR with Sentinel-CPS between 2016 and 2020 (n = 92) was performed. We investigated the impact of aortic arch anatomy, configuration, and the angles of the supra-aortic arteries, including the determination of vascular tortuosity index on device failure of Sentinel-CPS application. RESULTS: The Sentinel-CPS was applied successfully in 83 patients (90.2%). Device failure in nine patients (9.8%) was due to the infeasibility to perform correct deployment of both filters (n = 7) and to obtain peripheral radial access (n = 2). Patients with a failure of Sentinel-CPS application had a higher right subclavian tortuosity index (217 [92-324] vs. 150 [42-252], p = .046), a higher brachiocephalic tortuosity index (27 [5-51] vs. 10 [0-102], p = 0.033) and a larger angulation of the brachiocephalic artery (59° [22-80] vs. 39° [7-104], p = .014) compared with patients with successful application. A brachiocephalic angle more than 59° was predictive for device failure. No differences in aortic arch anatomy or common carotid artery tortuosity were detected between the groups. CONCLUSIONS: Brachiocephalic tortuosity was found to be associated with failure of Sentinel-CPS application. Filter-based usage should be avoided in TAVR patients with a brachiocephalic angle more than 59°.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Tomografía Computarizada Multidetector , Diseño de Prótesis , Factores de Riesgo , Resultado del Tratamiento
18.
J Card Surg ; 36(4): 1298-1304, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33512725

RESUMEN

OBJECTIVES: For tailored treatment of primary mitral regurgitation (MR), surgeons developed different repair techniques. One of them, the edge-to-edge repair has recently seen a revival, especially for Barlow's disease. METHODS: This study was designed to assess the outcomes of the edge-to-edge technique in mitral valve (MV) repair. Preoperative, periprocedural, and postoperative data were prospectively collected in a dedicated database and analyzed retrospectively. RESULTS: Between March 1999 and July 2019, a total of 152 patients (mean age: 60 ± 13) received an edge-to-edge repair combined with annuloplasty for degenerative MR at our institution. MR resulted from posterior leaflet prolapse in 23 patients (15.1%), anterior leaflet prolapse in 19 (12.5%), and bileaflet prolapse in 110 (72.4%). Of those who had a bileaflet prolapse, 91 (82.7%) had Barlow's disease. Follow-up was complete in 97.4% (6.4 ± 5.7 years). Echocardiographic assessment was achieved in 85.5% (5.1 ± 5.6 years). Overall survival after 10 years was 73.7 ± 5.0%. Twelve patients required valve-related reoperations due to ring dehiscence (n = 2), leaflet suture dehiscence (n = 2), progression of native valve disease (n = 6), or due to device failure (ring fracture) (n = 2). The cumulative incidence of valve-related reoperation at 10 years was 8.4 ± 3.0% (5.2 ± 4.1% in patients with Barlow's disease). At latest follow-up, echocardiography revealed excellent valve function with no or mild MR in 93 patients (88.6%). The mean gradient was 2.9 ± 1.3 mmHg at discharge and decreased to 2.4 ± 1.3 mmHg. Three patients (2.8%) had more than moderate MR. CONCLUSION: Edge-to-edge MV repair is a simple method with excellent results in terms of valvular function and durability especially in patients with Barlow's disease.


Asunto(s)
Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Anciano , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
19.
J Card Surg ; 36(4): 1241-1248, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33484180

RESUMEN

PURPOSE: The Sentinel Cerebral Protection System (Sentinel-CPS) is increasingly used in transcatheter aortic valve replacement (TAVR). However, the impact of inserting the Sentinel-CPS inside the brain-supplying arteries on cerebral perfusion and oxygenation is unknown. METHODS: Twenty patients undergoing transfemoral TAVR with (n = 10) and without (n = 10) cerebral embolic protection using the Sentinel-CPS were prospectively observed. All patients received conscious sedation and cerebral oxygen saturation (rSO2 ) was continuously measured with near-infrared spectroscopy (NIRS). The cumulative perioperative cerebral desaturation was calculated for each patient by multiplying rSO2 below an individualized desaturation threshold by time. In addition, rSO2 values at the time of Sentinel-CPS insertion, filter positioning, and device retraction were analyzed. RESULTS: There was no significant difference in cumulative cerebral desaturation in patients with Sentinel-CPS (median [IQR]) (0 [0/81] s%) and without (median [IQR]) (0 [0/23] s%), p = .762. A total of 6 patients (33.3%) experienced a perioperative decrease in rSO2 below the individualized desaturation threshold (n = 3 with Sentinel-CPS, n = 3 without Sentinel-CPS; p = 1.000). Cerebral desaturation was detected during valve deployment (n = 5) and after postdilatation (n = 1). No desaturation events occurred during Sentinel-CPS insertion, filter positioning, or retraction. CONCLUSION: Our pilot study revealed no difference in cumulative perioperative cerebral desaturation between TAVR with and without Sentinel-CPS. Catheter- and filter-based manipulations in the brain-supplying arteries for Sentinel-CPS application were not associated with a decrease of cerebral perfusion and oxygenation.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Oxígeno , Proyectos Piloto , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS