Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Crit Care ; 28(1): 107, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38566126

RESUMEN

BACKGROUND: Pre-clinical studies suggest that dyssynchronous diaphragm contractions during mechanical ventilation may cause acute diaphragm dysfunction. We aimed to describe the variability in diaphragm contractile loading conditions during mechanical ventilation and to establish whether dyssynchronous diaphragm contractions are associated with the development of impaired diaphragm dysfunction. METHODS: In patients receiving invasive mechanical ventilation for pneumonia, septic shock, acute respiratory distress syndrome, or acute brain injury, airway flow and pressure and diaphragm electrical activity (Edi) were recorded hourly around the clock for up to 7 days. Dyssynchronous post-inspiratory diaphragm loading was defined based on the duration of neural inspiration after expiratory cycling of the ventilator. Diaphragm function was assessed on a daily basis by neuromuscular coupling (NMC, the ratio of transdiaphragmatic pressure to diaphragm electrical activity). RESULTS: A total of 4508 hourly recordings were collected in 45 patients. Edi was low or absent (≤ 5 µV) in 51% of study hours (median 71 h per patient, interquartile range 39-101 h). Dyssynchronous post-inspiratory loading was present in 13% of study hours (median 7 h per patient, interquartile range 2-22 h). The probability of dyssynchronous post-inspiratory loading was increased with reverse triggering (odds ratio 15, 95% CI 8-35) and premature cycling (odds ratio 8, 95% CI 6-10). The duration and magnitude of dyssynchronous post-inspiratory loading were associated with a progressive decline in diaphragm NMC (p < 0.01 for interaction with time). CONCLUSIONS: Dyssynchronous diaphragm contractions may impair diaphragm function during mechanical ventilation. TRIAL REGISTRATION: MYOTRAUMA, ClinicalTrials.gov NCT03108118. Registered 04 April 2017 (retrospectively registered).


Asunto(s)
Respiración Artificial , Síndrome de Dificultad Respiratoria , Humanos , Diafragma , Respiración Artificial/efectos adversos , Tórax , Ventiladores Mecánicos
2.
J Perinatol ; 44(2): 244-249, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38129599

RESUMEN

OBJECTIVE: To measure tidal volume delivery during nasal intermittent positive pressure ventilation with two nasal interfaces: infant cannula and nasal prongs. STUDY DESIGN: A single-center crossover study of neonates with mild respiratory distress. Fifteen preterm neonates were randomized to initial interface of infant cannula or nasal prongs and monitored on a sequence of pressure settings first on the initial interface, then repeated on the alternate interface. We compared relative tidal volumes between the two interfaces with two-way repeated measures ANOVA during three breath types: synchronized (I), patient effort without ventilator breaths (II), and ventilator breaths without patient effort (III). Clinical trial #NCT04326270. RESULTS: Type III breaths delivered no significant tidal volume. No significant difference was measured in relative tidal volume delivery between the interfaces when breath types were matched. CONCLUSIONS: Nasal intermittent positive pressure ventilation delivers neither clinically nor statistically significant tidal volume with either infant cannula or nasal prongs.


Asunto(s)
Recien Nacido Prematuro , Ventilación con Presión Positiva Intermitente , Recién Nacido , Lactante , Humanos , Presión de las Vías Aéreas Positiva Contínua , Volumen de Ventilación Pulmonar , Cánula , Estudios Cruzados
3.
Ann Intensive Care ; 13(1): 122, 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38055103

RESUMEN

BACKGROUND: The unsuccessful extubation in patients with traumatic cervical spinal cord injuries (CSCI) may result from impairment diaphragm function and monitoring of diaphragm electrical activity (EAdi) can be informative in guiding extubation. We aimed to evaluate whether the change of EAdi during a single maximal maneuver can predict extubation outcomes in CSCI patients. METHODS: This is a retrospective study of CSCI patients requiring mechanical ventilation in the ICU of a tertiary hospital. A single maximal maneuver was performed by asking each patient to inhale with maximum strength during the first spontaneous breathing trial (SBT). The baseline (during SBT before maximal maneuver), maximum (during the single maximal maneuver), and the increase of EAdi (ΔEAdi, equal to the difference between baseline and maximal) were measured. The primary outcome was extubation success, defined as no reintubation after the first extubation and no tracheostomy before any extubation during the ICU stay. RESULTS: Among 107 patients enrolled, 50 (46.7%) were extubated successfully at the first SBT. Baseline EAdi, maximum EAdi, and ΔEAdi were significantly higher, and the rapid shallow breathing index was lower in patients who were extubated successfully than in those who failed. By multivariable logistic analysis, ΔEAdi was independently associated with successful extubation (OR 2.03, 95% CI 1.52-3.17). ΔEAdi demonstrated high diagnostic accuracy in predicting extubation success with an AUROC 0.978 (95% CI 0.941-0.995), and the cut-off value was 7.0 µV. CONCLUSIONS: The increase of EAdi from baseline SBT during a single maximal maneuver is associated with successful extubation and can help guide extubation in CSCI patients.

4.
Crit Care ; 27(1): 325, 2023 08 25.
Artículo en Inglés | MEDLINE | ID: mdl-37626372

RESUMEN

BACKGROUND: Mechanical ventilation is applied to unload the respiratory muscles, but knowledge about transpulmonary driving pressure (ΔPL) is important to minimize lung injury. We propose a method to estimate ΔPL during neurally synchronized assisted ventilation, with a simple intervention of lowering the assist for one breath ("lower assist maneuver", LAM). METHODS: In 24 rabbits breathing spontaneously with imposed loads, titrations of increasing assist were performed, with two neurally synchronized modes: neurally adjusted ventilatory assist (NAVA) and neurally triggered pressure support (NPS). Two single LAM breaths (not sequentially, but independently) were performed at each level of assist by acutely setting the assist to zero cm H2O (NPS) or NAVA level 0 cm H2O/uV (NAVA) for one breath. NPS and NAVA titrations were followed by titrations in controlled-modes (volume control, VC and pressure control, PC), under neuro-muscular blockade. Breaths from the NAVA/NPS titrations were matched (for flow and volume) to VC or PC. Throughout all runs, we measured diaphragm electrical activity (Edi) and esophageal pressure (PES). We measured ΔPL during the spontaneous modes (PL_PES) and controlled mechanical ventilation (CMV) modes (PL_CMV) with the esophageal balloon. From the LAMs, we derived an estimation of ΔPL ("PL_LAM") using a correction factor (ratio of volume during the LAM and volume during assist) and compared it to measured ΔPL during passive (VC or PC) and spontaneous breathing (NAVA or NPS). A requirement for the LAM was similar Edi to the assisted breath. RESULTS: All animals successfully underwent titrations and LAMs for NPS/NAVA. One thousand seven-hundred ninety-two (1792) breaths were matched to passive ventilation titrations (matched Vt, r = 0.99). PL_LAM demonstrated strong correlation with PL_CMV (r = 0.83), and PL_PES (r = 0.77). Bland-Altman analysis revealed little difference between the predicted PL_LAM and measured PL_CMV (Bias = 0.49 cm H2O and 1.96SD = 3.09 cm H2O). For PL_PES, the bias was 2.2 cm H2O and 1.96SD was 3.4 cm H2O. Analysis of Edi and PES at peak Edi showed progressively increasing uncoupling with increasing assist. CONCLUSION: During synchronized mechanical ventilation, a LAM breath allows for estimations of transpulmonary driving pressure, without measuring PES, and follows a mathematical transfer function to describe respiratory muscle unloading during synchronized assist.


Asunto(s)
Infecciones por Citomegalovirus , Soporte Ventilatorio Interactivo , Animales , Conejos , Respiración Artificial , Respiración con Presión Positiva , Respiración
5.
Pediatr Res ; 93(4): 878-886, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35941145

RESUMEN

BACKGROUND: A sealed abdominal interface was positioned below the diaphragm (the "NeoVest") to apply synchronized and proportional negative pressure ventilation (NPV) and was compared to positive pressure ventilation (PPV) using neurally adjusted ventilatory assist (NAVA). Both modes were controlled by the diaphragm electrical activity (Edi). METHODS: Eleven rabbits (mean weight 2.9 kg) were instrumented, tracheotomized, and ventilated with either NPV or PPV (sequentially) with different loads (resistive, dead space, acute lung injury). Assist with either PPV or NPV was titrated to reduce Edi by 50%. RESULTS: In order to achieve a 50% reduction in Edi, NPV required slightly more negative pressure (-8 to -12 cm H2O) than observed in PPV (+6 to +10 cm H2O). The efficiency of pressure transmission from the NeoVest into gastric pressure was 69.6% (range 61.3-77.4%). Swings in esophageal pressure were more negative during NPV than PPV, for all conditions, due to transmission of negative pressure. Transpulmonary pressure was lower during NPV. Transdiaphragmatic pressure swings were reduced similarly for PPV and NPV, suggesting equivalent unloading of the diaphragm. NPV did not affect hemodynamics. CONCLUSIONS: It is feasible to apply NPV sub-diaphragmatically in synchrony and in proportion to Edi in an animal model of respiratory distress. IMPACT: Negative pressure ventilation (NPV), for example, the "Iron Lung," may offer advantages over positive pressure ventilation. In the present work, we describe the "NeoVest," a system consisting of a sealed abdominal interface and a ventilator that applies NPV in synchrony and in proportion to the diaphragm electrical activity (Edi).


Asunto(s)
Soporte Ventilatorio Interactivo , Síndrome de Dificultad Respiratoria , Animales , Conejos , Respiración Artificial , Diafragma , Respiración con Presión Positiva , Modelos Animales
7.
Tissue Eng Part C Methods ; 27(12): 661-671, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34847779

RESUMEN

While transplantation is a viable treatment option for end-stage lung diseases, this option is highly constrained by the availability of organs and postoperative complications. A potential solution is the use of bioengineered lungs generated from repopulated acellular scaffolds. Effective recellularization, however, remains a challenge. In this proof-of-concept study, mice lung scaffolds were decellurized and recellurized using human bronchial epithelial cells (BEAS2B). We present a novel liquid ventilation protocol enabling control over tidal volume and high rates of ventilation. The use of a physiological tidal volume (300 µL) for mice and a higher ventilation rate (40 breaths per minute vs. 1 breath per minute) resulted in higher cell numbers and enhanced cell surface coverage in mouse lung scaffolds as determined via histological evaluation, genomic polymerase chain reaction (PCR) analysis, and immunohistochemistry. A biomimetic lung bioreactor system was designed to include the new ventilation protocol and allow for simultaneous vascular perfusion. We compared the lungs cultured in our dual system to lungs cultured with a bioreactor allowing vascular perfusion only and showed that our system significantly enhances cell numbers and surface coverage. In summary, our results demonstrate the importance of the physical environment and forces for lung recellularization. Impact statement New bioreactor systems are required to further enhance the regeneration process of bioengineered lungs. This proof-of-concept study describes a novel ventilation protocol that allows for control over ventilation parameters such as rate and tidal volume. Our data show that a higher rate of ventilation is correlated with higher cell numbers and increased surface coverage. We designed a new biomimetic bioreactor system that allows for ventilation and simultaneous perfusion. Compared to a traditional perfusion only system, recellularization was enhanced in lungs recellularized with our new biomimetic bioreactor.


Asunto(s)
Pulmón , Ventilación Pulmonar , Ingeniería de Tejidos , Andamios del Tejido , Animales , Células Epiteliales , Pulmón/citología , Ratones , Perfusión , Ventilación Pulmonar/fisiología , Ingeniería de Tejidos/métodos
8.
Clin Perinatol ; 48(4): 783-811, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34774209

RESUMEN

Patient-ventilator asynchrony is very common in newborns. Achieving synchrony is quite challenging because of small tidal volumes, high respiratory rates, and the presence of leaks. Leaks also cause unreliable monitoring of respiratory metrics. In addition, ventilator adjustment must take into account that infants have strong vagal reflexes and demonstrate central apnea and periodic breathing, with a high variability in breathing pattern. Neurally adjusted ventilatory assist (NAVA) is a mode of ventilation whereby the timing and amount of ventilatory assist is controlled by the patient's own neural respiratory drive. As NAVA uses the diaphragm electrical activity (Edi) as the controller signal, it is possible to deliver synchronized assist, both invasively and noninvasively (NIV-NAVA), to follow the variability in breathing pattern, and to monitor patient respiratory drive, independent of leaks. This article provides an updated review of the physiology and the scientific literature pertaining to the use of NAVA in children (neonatal and pediatric age groups). Both the invasive NAVA and NIV-NAVA publications since 2016 are summarized, as well as the use of Edi monitoring. Overall, the use of NAVA and Edi monitoring is feasible and safe. Compared with conventional ventilation, NAVA improves patient-ventilator interaction, provides lower peak inspiratory pressure, and lowers oxygen requirements. Evidence from several studies suggests improved comfort, less sedation requirements, less apnea, and some trends toward reduced length of stay and more successful extubation.


Asunto(s)
Soporte Ventilatorio Interactivo , Niño , Diafragma , Humanos , Lactante , Recién Nacido , Monitoreo Fisiológico , Oxígeno , Volumen de Ventilación Pulmonar
9.
Crit Care ; 25(1): 222, 2021 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-34187528

RESUMEN

BACKGROUND: Prolonged ventilatory support is associated with poor clinical outcomes. Partial support modes, especially pressure support ventilation, are frequently used in clinical practice but are associated with patient-ventilation asynchrony and deliver fixed levels of assist. Neurally adjusted ventilatory assist (NAVA), a mode of partial ventilatory assist that reduces patient-ventilator asynchrony, may be an alternative for weaning. However, the effects of NAVA on weaning outcomes in clinical practice are unclear. METHODS: We searched PubMed, Embase, Medline, and Cochrane Library from 2007 to December 2020. Randomized controlled trials and crossover trials that compared NAVA and other modes were identified in this study. The primary outcome was weaning success which was defined as the absence of ventilatory support for more than 48 h. Summary estimates of effect using odds ratio (OR) for dichotomous outcomes and mean difference (MD) for continuous outcomes with accompanying 95% confidence interval (CI) were expressed. RESULTS: Seven studies (n = 693 patients) were included. Regarding the primary outcome, patients weaned with NAVA had a higher success rate compared with other partial support modes (OR = 1.93; 95% CI 1.12 to 3.32; P = 0.02). For the secondary outcomes, NAVA may reduce duration of mechanical ventilation (MD = - 2.63; 95% CI - 4.22 to - 1.03; P = 0.001) and hospital mortality (OR = 0.58; 95% CI 0.40 to 0.84; P = 0.004) and prolongs ventilator-free days (MD = 3.48; 95% CI 0.97 to 6.00; P = 0.007) when compared with other modes. CONCLUSIONS: Our study suggests that the NAVA mode may improve the rate of weaning success compared with other partial support modes for difficult to wean patients.


Asunto(s)
Técnicas de Diagnóstico Neurológico/normas , Soporte Ventilatorio Interactivo/normas , Músculos Respiratorios/fisiopatología , Desconexión del Ventilador/métodos , Adulto , Técnicas de Diagnóstico Neurológico/estadística & datos numéricos , Humanos , Soporte Ventilatorio Interactivo/instrumentación , Soporte Ventilatorio Interactivo/métodos , Desconexión del Ventilador/instrumentación , Desconexión del Ventilador/estadística & datos numéricos
10.
Anesthesiology ; 134(5): 760-769, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33662121

RESUMEN

BACKGROUND: Reverse triggering is a delayed asynchronous contraction of the diaphragm triggered by passive insufflation by the ventilator in sedated mechanically ventilated patients. The incidence of reverse triggering is unknown. This study aimed at determining the incidence of reverse triggering in critically ill patients under controlled ventilation. METHODS: In this ancillary study, patients were continuously monitored with a catheter measuring the electrical activity of the diaphragm. A method for automatic detection of reverse triggering using electrical activity of the diaphragm was developed in a derivation sample and validated in a subsequent sample. The authors assessed the predictive value of the software. In 39 recently intubated patients under assist-control ventilation, a 1-h recording obtained 24 h after intubation was used to determine the primary outcome of the study. The authors also compared patients' demographics, sedation depth, ventilation settings, and time to transition to assisted ventilation or extubation according to the median rate of reverse triggering. RESULTS: The positive and negative predictive value of the software for detecting reverse triggering were 0.74 (95% CI, 0.67 to 0.81) and 0.97 (95% CI, 0.96 to 0.98). Using a threshold of 1 µV of electrical activity to define diaphragm activation, median reverse triggering rate was 8% (range, 0.1 to 75), with 44% (17 of 39) of patients having greater than or equal to 10% of breaths with reverse triggering. Using a threshold of 3 µV, 26% (10 of 39) of patients had greater than or equal to 10% reverse triggering. Patients with more reverse triggering were more likely to progress to an assisted mode or extubation within the following 24 h (12 of 39 [68%]) vs. 7 of 20 [35%]; P = 0.039). CONCLUSIONS: Reverse triggering detection based on electrical activity of the diaphragm suggests that this asynchrony is highly prevalent at 24 h after intubation under assist-control ventilation. Reverse triggering seems to occur during the transition phase between deep sedation and the onset of patient triggering.


Asunto(s)
Diafragma/fisiología , Monitoreo Fisiológico/métodos , Contracción Muscular/fisiología , Respiración Artificial , Enfermedad Crítica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tiempo
11.
Crit Care ; 25(1): 26, 2021 01 11.
Artículo en Inglés | MEDLINE | ID: mdl-33430930

RESUMEN

BACKGROUND: In patients intubated for mechanical ventilation, prolonged diaphragm inactivity could lead to weakness and poor outcome. Time to resume a minimal diaphragm activity may be related to sedation practice and patient severity. METHODS: Prospective observational study in critically ill patients. Diaphragm electrical activity (EAdi) was continuously recorded after intubation looking for resumption of a minimal level of diaphragm activity (beginning of the first 24 h period with median EAdi > 7 µV, a threshold based on literature and correlations with diaphragm thickening fraction). Recordings were collected until full spontaneous breathing, extubation, death or 120 h. A 1 h waveform recording was collected daily to identify reverse triggering. RESULTS: Seventy-five patients were enrolled and 69 analyzed (mean age ± standard deviation 63 ± 16 years). Reasons for ventilation were respiratory (55%), hemodynamic (19%) and neurologic (20%). Eight catheter disconnections occurred. The median time for resumption of EAdi was 22 h (interquartile range 0-50 h); 35/69 (51%) of patients resumed activity within 24 h while 4 had no recovery after 5 days. Late recovery was associated with use of sedative agents, cumulative doses of propofol and fentanyl, controlled ventilation and age (older patients receiving less sedation). Severity of illness, oxygenation, renal and hepatic function, reason for intubation were not associated with EAdi resumption. At least 20% of patients initiated EAdi with reverse triggering. CONCLUSION: Low levels of diaphragm electrical activity are common in the early course of mechanical ventilation: 50% of patients do not recover diaphragmatic activity within one day. Sedatives are the main factors accounting for this delay independently from lung or general severity. Trial Registration ClinicalTrials.gov (NCT02434016). Registered on April 27, 2015. First patients enrolled June 2015.


Asunto(s)
Diafragma/fisiopatología , Intubación Intratraqueal/efectos adversos , Conducta Sedentaria , Factores de Tiempo , Anciano , Anciano de 80 o más Años , Enfermedad Crítica/epidemiología , Enfermedad Crítica/terapia , Femenino , Humanos , Intubación Intratraqueal/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Respiración Artificial/efectos adversos , Respiración Artificial/métodos
12.
Physiol Rep ; 8(13): e14499, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32633080

RESUMEN

RATIONALE: Synchronized positive pressure ventilation is possible using diaphragm electrical activity (EAdi) to control the ventilator. It is unknown whether EAdi can be used to control negative pressure ventilation. AIM: To evaluate the feasibility of using EAdi to control negative pressure ventilation. METHODS: Fourteen anesthetized rats were studied (380-590 g) during control, resistive breathing, acute lung injury or CO2 rebreathing. Positive pressure continuous neurally adjusted ventilatory assist (cNAVAP+ ) was applied via intubation. Negative pressure cNAVA (cNAVAP- ) was applied with the animal placed in a sealed box. In part 1, automatic stepwise increments in cNAVA level by 0.2 cmH2 O/µV every 30 s was applied for cNAVAP+ , cNAVAP- , and a 50/50 combination of the two (cNAVAP± ). In part 2: During 5-min ventilation with cNAVAP+ or cNAVAP- we measured circuit, box, and esophageal (Pes) pressure, EAdi, blood pressure, and arterial blood gases. RESULTS: Part 1: During cNAVAP+ , pressure in the circuit increased with increasing cNAVA levels, reaching a plateau, and similarly for cNAVAP- , albeit reversed in sign. This was associated with downregulation of the EAdi. Pes swings became less negative with cNAVAP+ but, in contrast, Pes swings were more negative during increasing cNAVAP- levels. Increasing the cNAVA level during cNAVAP± resulted in an intermediate response. Part 2: no significant differences were observed for box/circuit pressures, EAdi, blood pressure, or arterial blood gases. Pes swings during cNAVAP- were significantly more negative than during cNAVAP+ . CONCLUSION: Negative pressure ventilation synchronized and proportional to the diaphragm activity is feasible in small animals.


Asunto(s)
Respiración Artificial/métodos , Animales , Diafragma/fisiología , Masculino , Contracción Muscular , Ratas , Ratas Sprague-Dawley , Respiración Artificial/instrumentación , Respiración Artificial/normas , Ventiladores de Presión Negativa
13.
Arch Dis Child Fetal Neonatal Ed ; 105(6): 640-645, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32269148

RESUMEN

OBJECTIVES: To assess the feasibility and tolerance of NeuroPAP, a new non-invasive ventilation mode which continuously adjusts (during both inspiration and expiration) the pressure support proportionally to the diaphragm electrical activity (Edi), in preterm infants and to evaluate the impact on ventilation pressure and Edi. DESIGN: Prospective cross-over single-centre feasibility study. SETTING: One level 3 neonatal intensive care unit in Canada. PATIENTS: Stable preterm infants ventilated with non-invasive positive pressure ventilation (NIPPV). INTERVENTIONS: Subjects were successively ventilated in NIPPV with prestudy settings (30 min), in NeuroPAP with minimal pressure similar to NIPPV PEEP (positive end-expiratory pressure) (60 min), in NeuroPAP with minimal pressure reduced by 2 cmH20 (60 min), in continuous positive airway pressure (15 min) and again in NIPPV (30 min). Main outcome measures included tolerance, ventilation pressure, Edi and patient-ventilator synchrony. RESULTS: Twenty infants born at 28.0±1.0 weeks were included. NeuroPAP was well tolerated and could be delivered during 100% of planned period. During NeuroPAP, the PEEP was continuously adjusted proportionally to tonic diaphragm Edi, although the average PEEP value was similar to the set minimal pressure. During NeuroPAP, 83 (78-86)% breaths were well synchronised vs 9 (6-12)% breaths during NIPPV (p<0.001). CONCLUSIONS: NeuroPAP is feasible and well tolerated in stable preterm infants, and it allows transient adaptation in PEEP in response to tonic diaphragm electrical activity changes. Further studies are warranted to determine the impact of these findings on clinical outcomes. TRIAL REGISTRATION NUMBER: NCT02480205.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua/métodos , Enfermedades del Prematuro/terapia , Ventilación no Invasiva/métodos , Insuficiencia Respiratoria/terapia , Presión de las Vías Aéreas Positiva Contínua/efectos adversos , Estudios de Factibilidad , Femenino , Edad Gestacional , Humanos , Recién Nacido , Recien Nacido Prematuro , Masculino , Ventilación no Invasiva/efectos adversos , Estudios Prospectivos
14.
Respir Care ; 65(7): 946-953, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32071130

RESUMEN

BACKGROUND: We tested whether work of breathing in premature newborns estimated by phase angle (θ) by using respiratory inductance plethysmography is decreased during neurally-adjusted ventilatory assist (NAVA) noninvasive ventilation (NIV) versus NIV alone. METHODS: NAVA NIV and NIV were applied in random order while using respiratory inductance plethysmography to measure the phase angle. RESULTS: Patient-ventilator asynchrony was decreased during NAVA NIV; however, the phase angle was not different between the modes. A large number of repeated assists with switches to backup were found when using NAVA NIV. Results of the analysis indicated these were due to the apnea alarm limit set during NAVA NIV. CONCLUSIONS: The improvement in patient-ventilator synchrony supports the hypothesis that work of breathing may be decreased with NAVA NIV; however, we were unable to demonstrate this with our study design. Short apnea time settings with NAVA NIV led to a large number of switches to backup and repeated assists during the same neural effort. (ClinicalTrials.gov registration NCT02788110.).


Asunto(s)
Soporte Ventilatorio Interactivo , Ventilación no Invasiva , Apnea , Humanos , Recién Nacido , Recien Nacido Prematuro , Respiración , Trabajo Respiratorio
15.
Crit Care ; 23(1): 346, 2019 11 06.
Artículo en Inglés | MEDLINE | ID: mdl-31694692

RESUMEN

BACKGROUND: Excessive respiratory muscle effort during mechanical ventilation may cause patient self-inflicted lung injury and load-induced diaphragm myotrauma, but there are no non-invasive methods to reliably detect elevated transpulmonary driving pressure and elevated respiratory muscle effort during assisted ventilation. We hypothesized that the swing in airway pressure generated by respiratory muscle effort under assisted ventilation when the airway is briefly occluded (ΔPocc) could be used as a highly feasible non-invasive technique to screen for these conditions. METHODS: Respiratory muscle pressure (Pmus), dynamic transpulmonary driving pressure (ΔPL,dyn, the difference between peak and end-expiratory transpulmonary pressure), and ΔPocc were measured daily in mechanically ventilated patients in two ICUs in Toronto, Canada. A conversion factor to predict ΔPL,dyn and Pmus from ΔPocc was derived and validated using cross-validation. External validity was assessed in an independent cohort (Nanjing, China). RESULTS: Fifty-two daily recordings were collected in 16 patients. In this sample, Pmus and ΔPL were frequently excessively high: Pmus exceeded 10 cm H2O on 84% of study days and ΔPL,dyn exceeded 15 cm H2O on 53% of study days. ΔPocc measurements accurately detected Pmus > 10 cm H2O (AUROC 0.92, 95% CI 0.83-0.97) and ΔPL,dyn > 15 cm H2O (AUROC 0.93, 95% CI 0.86-0.99). In the external validation cohort (n = 12), estimating Pmus and ΔPL,dyn from ΔPocc measurements detected excessively high Pmus and ΔPL,dyn with similar accuracy (AUROC ≥ 0.94). CONCLUSIONS: Measuring ΔPocc enables accurate non-invasive detection of elevated respiratory muscle pressure and transpulmonary driving pressure. Excessive respiratory effort and transpulmonary driving pressure may be frequent in spontaneously breathing ventilated patients.


Asunto(s)
Ventilación no Invasiva/métodos , Presión , Pesos y Medidas/instrumentación , Trabajo Respiratorio/fisiología , Lesión Pulmonar Aguda/fisiopatología , Lesión Pulmonar Aguda/prevención & control , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Respiración Artificial/métodos , Músculos Respiratorios/lesiones , Músculos Respiratorios/fisiopatología , Pesos y Medidas/normas
16.
Intensive Care Med ; 45(10): 1372-1381, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31576436

RESUMEN

PURPOSE: Respiratory muscle weakness frequently develops in critically ill patients and is associated with adverse outcome, including difficult weaning from mechanical ventilation. Today, no drug is approved to improve respiratory muscle function in these patients. Previously, we have shown that the calcium sensitizer levosimendan improves calcium sensitivity of human diaphragm muscle fibers in vitro and contractile efficiency of the diaphragm in healthy subjects. The main purpose of this study is to investigate the effects of levosimendan on diaphragm contractile efficiency in mechanically ventilated patients. METHODS: In a double-blind randomized placebo-controlled trial, mechanically ventilated patients performed two 30-min continuous positive airway pressure (CPAP) trials with 5-h interval. After the first CPAP trial, study medication (levosimendan 0.2 µg/kg/min continuous infusion or placebo) was administered. During the CPAP trials, electrical activity of the diaphragm (EAdi), transdiaphragmatic pressure (Pdi), and flow were measured. Neuromechanical efficiency (primary outcome parameter) was calculated. RESULTS: Thirty-nine patients were included in the study. Neuromechanical efficiency was not different during the CPAP trial after levosimendan administration compared to the CPAP trial before study medication. Tidal volume and minute ventilation were higher after levosimendan administration (11 and 21%, respectively), whereas EAdi and Pdi were higher in both groups in the CPAP trial after study medication compared to the CPAP trial before study medication. CONCLUSIONS: Levosimendan does not improve diaphragm contractile efficiency.


Asunto(s)
Músculos Respiratorios/efectos de los fármacos , Simendán/farmacología , Desconexión del Ventilador/métodos , Enfermedad Crítica/terapia , Método Doble Ciego , Fenómenos Electromagnéticos , Humanos , Debilidad Muscular/etiología , Debilidad Muscular/fisiopatología , Presión , Respiración Artificial/métodos , Simendán/uso terapéutico , Desconexión del Ventilador/normas , Desconexión del Ventilador/tendencias
17.
J Appl Physiol (1985) ; 127(1): 264-271, 2019 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-31161879

RESUMEN

The patient-ventilator breath contribution (PVBC) index estimates the relative contribution of the patient to total tidal volume (Vtinsp) during mechanical ventilation in neurally adjusted ventilator assist mode and has been used to titrate ventilator support. The reliability of this index in ventilated patients is unknown and was investigated in this study. PVBC was calculated by comparing tidal volume (Vtinsp) and diaphragm electrical activity (EAdi) during assisted breaths (Vtinsp/EAdi)assist and during unassisted breaths (Vtinsp/EAdi)no-assist. Vtinsp was normalized to peak EAdi (EAdipeak) using 1) one assisted breath, 2) five consecutive assisted breaths, or 3) five assisted breaths with matching EAdi preceding the unassisted breath (N1PVBC2, X5PVBC2, and PX5VBCEAdi-matching2 , respectively). In addition, PVBC was calculated by comparing only Vtinsp for breaths with matching EAdi (PVBCß2). Test-retest reliability of the different PVBC calculation methods was evaluated with the intraclass correlation coefficient (ICC) using five repeated PVBC maneuvers performed with a 1-min interval. In total, 125 PVBC maneuvers were analyzed in 25 patients. ICC [95% confidence interval] values were 0.46 [0.23-0.66], 0.51 [0.33-0.70], and 0.42 [0.14-0.69] for N1PVBC2, X5PVBC2, PX5VBCEAdi-matching2 , respectively. Complex waveform analyses showed that insufficient EAdi filtering by the ventilator software affects reliability of PVBC calculation. With our new EAdi-matching techniques reliability improved (PVBCß2 ICC: 0.78 [0.60-0.90]). We conclude that current techniques to calculate PVBC exhibit low reliability and that our newly developed criteria and estimation of PVBC-using Vtinsp of assisted breaths and unassisted breaths with matching EAdi-improves reliability. This may help implementation of PVBC in clinical practice. NEW & NOTEWORTHY The patient-ventilator breath contribution (PVBC) index estimates the relative contribution of the patient to tidal volume generated by the patient and the mechanical ventilator during mechanical ventilation in neurally adjusted ventilator assist mode. It could be used to titrate ventilator support and thus to limit development of diaphragm dysfunction in intensive care unit patients. Currently available methods for bedside assessment of PVBC are unreliable. Our newly developed criteria and estimation of PVBC largely improve reliability and help to quantify patient contribution to total inspiratory effort.


Asunto(s)
Respiración Artificial/métodos , Volumen de Ventilación Pulmonar/fisiología , Anciano , Algoritmos , Alarmas Clínicas , Enfermedad Crítica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistemas de Atención de Punto , Estudios Prospectivos , Reproducibilidad de los Resultados , Respiración , Ventiladores Mecánicos
18.
Crit Care ; 23(1): 135, 2019 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-31014366

RESUMEN

BACKGROUND: Veno-venous extracorporeal CO2 removal (vv-ECCO2R) and non-invasive neurally adjusted ventilator assist (NIV-NAVA) are two promising techniques which may prevent complications related to prolonged invasive mechanical ventilation in patients with acute exacerbation of COPD. METHODS: A physiological study of the electrical activity of the diaphragm (Edi) response was conducted with varying degrees of extracorporeal CO2 removal to control the respiratory drive in patients with severe acute exacerbation of COPD breathing on NIV-NAVA. RESULTS: Twenty COPD patients (SAPS II 37 ± 5.6, age 57 ± 9 years) treated with vv-ECCO2R and supported by NIV-NAVA were studied during stepwise weaning of vv-ECCO2R. Based on dyspnea, tolerance, and blood gases, weaning from vv-ECCO2R was successful in 12 and failed in eight patients. Respiratory drive (measured via the Edi) increased to 19 ± 10 µV vs. 56 ± 20 µV in the successful and unsuccessful weaning groups, respectively, resulting in all patients keeping their CO2 and pH values stable. Edi was the best predictor for vv-ECCO2R weaning failure (ROC analysis AUC 0.95), whereas respiratory rate, rapid shallow breathing index, and tidal volume had lower predictive values. Eventually, 19 patients were discharged home, while one patient died. Mortality at 90 days and 180 days was 15 and 25%, respectively. CONCLUSIONS: This study demonstrates for the first time the usefulness of the Edi signal to monitor and guide patients with severe acute exacerbation of COPD on vv-ECCO2R and NIV-NAVA. The Edi during vv-ECCO2R weaning was found to be the best predictor of tolerance to removing vv-ECCO2R.


Asunto(s)
Dióxido de Carbono/efectos adversos , Hemofiltración/métodos , Soporte Ventilatorio Interactivo/métodos , Enfermedad Pulmonar Obstructiva Crónica/terapia , Anciano , Análisis de Varianza , Análisis de los Gases de la Sangre/métodos , Dióxido de Carbono/metabolismo , Femenino , Hemofiltración/tendencias , Humanos , Soporte Ventilatorio Interactivo/tendencias , Masculino , Persona de Mediana Edad , Ventilación no Invasiva/métodos , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Puntuación Fisiológica Simplificada Aguda
19.
J Perinatol ; 39(5): 723-729, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30755718

RESUMEN

BACKGROUND: Nasal intermittent positive pressure ventilation (NIPPV) is a widely used mode of support in neonates, during which ventilator inflations may or may not coincide with spontaneous breathing. OBJECTIVE: We tested the hypothesis that inflations delivered with NIPPV via RAM® cannula and not accompanied by patient effort produce minimal tidal volume as measured by respiratory inductance plethysmography. DESIGN/METHODS: Fourteen subjects were monitored while receiving NIPPV. We compared tidal volumes during ventilator-supported breaths, unsupported breaths, and ventilator inflations not accompanied by patient effort (defined using electrical activity of the diaphragm). RESULTS: Mean tidal volumes in arbitrary units were 0.30 ± 0.22 in NIPPV inflations associated with patient effort and 0.27 ± 0.15 in spontaneous breaths without ventilator assistance (p = 0.82). Tidal volumes during ventilator-only inflations were 0.06 ± 0.04 (p < 0.005 vs. both ventilator-assisted and unassisted efforts). CONCLUSIONS: NIPPV via RAM cannula produces minimal, clinically insignificant tidal volumes during non-spontaneous inflations.


Asunto(s)
Cánula , Recien Nacido Prematuro/fisiología , Ventilación con Presión Positiva Intermitente , Volumen de Ventilación Pulmonar , Estudios Cruzados , Femenino , Edad Gestacional , Humanos , Lactante , Recién Nacido , Cuidado Intensivo Neonatal/métodos , Masculino , Pletismografía , Estudios Retrospectivos
20.
Crit Care ; 22(1): 238, 2018 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-30261920

RESUMEN

BACKGROUND: Diaphragm dysfunction develops frequently in ventilated intensive care unit (ICU) patients. Both disuse atrophy (ventilator over-assist) and high respiratory muscle effort (ventilator under-assist) seem to be involved. A strong rationale exists to monitor diaphragm effort and titrate support to maintain respiratory muscle activity within physiological limits. Diaphragm electromyography is used to quantify breathing effort and has been correlated with transdiaphragmatic pressure and esophageal pressure. The neuromuscular efficiency index (NME) can be used to estimate inspiratory effort, however its repeatability has not been investigated yet. Our goal is to evaluate NME repeatability during an end-expiratory occlusion (NMEoccl) and its use to estimate the pressure generated by the inspiratory muscles (Pmus). METHODS: This is a prospective cohort study, performed in a medical-surgical ICU. A total of 31 adult patients were included, all ventilated in neurally adjusted ventilator assist (NAVA) mode with an electrical activity of the diaphragm (EAdi) catheter in situ. At four time points within 72 h five repeated end-expiratory occlusion maneuvers were performed. NMEoccl was calculated by delta airway pressure (ΔPaw)/ΔEAdi and was used to estimate Pmus. The repeatability coefficient (RC) was calculated to investigate the NMEoccl variability. RESULTS: A total number of 459 maneuvers were obtained. At time T = 0 mean NMEoccl was 1.22 ± 0.86 cmH2O/µV with a RC of 82.6%. This implies that when NMEoccl is 1.22 cmH2O/µV, it is expected with a probability of 95% that the subsequent measured NMEoccl will be between 2.22 and 0.22 cmH2O/µV. Additional EAdi waveform analysis to correct for non-physiological appearing waveforms, did not improve NMEoccl variability. Selecting three out of five occlusions with the lowest variability reduced the RC to 29.8%. CONCLUSIONS: Repeated measurements of NMEoccl exhibit high variability, limiting the ability of a single NMEoccl maneuver to estimate neuromuscular efficiency and therefore the pressure generated by the inspiratory muscles based on EAdi.


Asunto(s)
Enfermedad Crítica/terapia , Diafragma/fisiopatología , Eficiencia/fisiología , Estadística como Asunto/normas , Anciano , Estudios de Cohortes , Electromiografía/métodos , Femenino , Humanos , Unidades de Cuidados Intensivos/organización & administración , Soporte Ventilatorio Interactivo/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Respiración Artificial/métodos , Índice de Severidad de la Enfermedad , Estadística como Asunto/métodos , Trabajo Respiratorio/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA