Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Acta Biomed ; 94(S2): e2023145, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37366190

RESUMEN

The number of shoulder arthroplasties has increased tremendously over the last twenty years, creating a proportional increase in complications rates and revision. Shoulder arthroplasty surgeon should have a clear understanding of the reasons for failure based on the specific index procedure that was performed. The main challenge includes the need for component removal and managing glenoid and humeral bone defects. This manuscript aims to outline the most common indications for revision surgery and treatment options based on a careful and detailed review of the available literature.  This paper should help the surgeon in patient evaluation and selection of the optimal procedure for an individual patient.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artroplastia de Reemplazo , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Artroplastia de Reemplazo/métodos , Húmero/cirugía , Reoperación/métodos , Resultado del Tratamiento
2.
Orthop Rev (Pavia) ; 14(6): 38574, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36267213

RESUMEN

Background: Tranexamic acid and fibrin sealant have been shown to be effective in reducing the need for transfusion after hip fracture surgery. Objective: The aim of this study was to evaluate the efficacy of local haemostatic agents to reduce the need of postoperative transfusion in elederly patients after hip hemiarthroplasty. Methods: All patients admitted to our institution with a diagnosis of proximal femur fracture from September 2018 to March 2021 were involved. Inclusion criteria were: diagnosis of femoral neck fracture, classified as AO 31B2-3, surgical treatment with hip hemiarthroplasty, hemoglobinemia on admission > 8 gr/dL. Patients were divided in four groups. Results: EVICEL was used on 25 patients, TRANEX was used on 52 patients, standard hemostatic care was used on 73 patients, while post-surgical drain was used on 21 patients. 3 patients were transfused in the EVICEL group while 26 patients were transfused in the control group (p 0,0404), there was also statistical significant difference in the need of perioperative transfusion between EVICEL group and drain group with 10 patients transfused (p 0,0102). Statistical significant differences was found about haemoglobin variation in the first post-operative day between TRANEX group and control group (p 0,000155) and between TRANEX group and drain group (p 0,013) and also between TRANEX group and control group in the third post-operative day (p 0,0004). Conclusion: This study demonstrates that the use of both fibrin sealant or TXA can reduce total blood loss and the need of transfusions in geriatric population with intracapsular femur fracture.

3.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2237-2248, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32458032

RESUMEN

PURPOSE: To systematically review the outcomes of surgical treatments of chronic acromioclavicular joint dislocation. METHODS: Studies were identified by electronic databases (Ovid, PubMed). All studies reporting functional and radiological outcomes of surgical treatments of chronic acromioclavicular joint dislocations were included. Following data were extracted: authors and year, study design, level of evidence, number of patients, age, classification of acromioclavicular joint dislocation, time to surgery, surgical technique, follow-up, clinical and imaging outcomes, complications and failures. Descriptive statistics was used, when a data pooling was not possible. Comparable outcomes were pooled to generate summary outcomes reported as frequency-weighted values. Quality appraisal was assessed through the MINORS checklist. RESULTS: Fourty-four studies were included for a total of 1020 shoulders. Mean age of participants was 38 years. Mean follow-up was 32.9 months. Arthroscopic techniques showed better results than open approach (p < 0.0001). Synthetic reconstructions demonstrated better functional outcomes compared to internal fixation and biologic techniques (p < 0.0001). Among biologic techniques, combined coracoclavicular and acromioclavicular ligaments reconstruction showed better Constant (p = 0.0270) and ASES (p = 0.0113) scores compared to isolated coracoclavicular ligaments reconstruction; anatomic biologic non-augmented graft reconstruction showed better Constant (p < 0.0001), VAS (p < 0.0001) and SSV (p = 0.0177) results compared to augmented techniques. No differences in functional outcomes could be found between anatomic biologic non-augmented graft versus synthetic reconstructions. Overall, methodological quality of the included studies was low. CONCLUSION: Anatomic reconstructions, both synthetic and biologic, showed the best functional results. LEVEL OF EVIDENCE: IV.


Asunto(s)
Articulación Acromioclavicular/cirugía , Inestabilidad de la Articulación/cirugía , Procedimientos de Cirugía Plástica/métodos , Luxación del Hombro/cirugía , Adolescente , Adulto , Anciano , Artroscopía/métodos , Fijación Interna de Fracturas/métodos , Humanos , Luxaciones Articulares/cirugía , Ligamentos Articulares/cirugía , Persona de Mediana Edad , Radiografía/métodos , Hombro/cirugía , Resultado del Tratamiento , Adulto Joven
4.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2175-2193, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32797247

RESUMEN

PURPOSE: To systematically review the outcomes of surgical treatments of acute acromioclavicular joint dislocation. METHODS: Studies were identified by electronic databases (Ovid, PubMed). All studies reporting functional and radiological outcomes of surgical treatments of acute acromioclavicular joint dislocations were included. Following data were extracted: authors and year, study design, level of evidence, number of patients, age, classification of acromioclavicular joint dislocation, time to surgery, surgical technique, follow-up, clinical and imaging outcomes, complications, and failures. Descriptive statistics was used, when a data pooling was not possible. Comparable outcomes were pooled to generate summary outcomes reported as frequency-weighted values. Quality appraisal was assessed through the MINORS checklist. RESULTS: One hundred and thirty-three studies were included for a total of 4473 shoulders. Mean age of participants was 36.9 years. Mean follow-up was 42.06 months. Arthroscopy showed better ASES (p < 0.0001) and lower VAS pain score (p = 0.0249) compared to an open approach. Biologic and synthetic reconstructions demonstrated better results over osteosynthesis techniques. Biologic techniques showed overall better Constant (p = 0.0001) and DASH (p = 0.0215) scores, while synthetic reconstruction showed better UCLA score (p = 0.0001). Among suture buttons, triple button showed overall better results in Constant (p = 0.0001) and VAS (p = 0.0001) scores, while better results in DASH score (p = 0.0003) were achieved by 2 double button techniques. Overall, the level of evidence was low. CONCLUSION: Biological and synthetic reconstructions achieved better functional scores compared to osteosynthesis. Among suture buttons, the triple button showed better functional performance. LEVEL OF EVIDENCE: IV.


Asunto(s)
Articulación Acromioclavicular/cirugía , Artroscopía/métodos , Luxaciones Articulares/cirugía , Ligamentos Articulares/cirugía , Prótesis e Implantes , Articulación Acromioclavicular/diagnóstico por imagen , Artroscopía/efectos adversos , Artroscopía/instrumentación , Traumatismos en Atletas/diagnóstico por imagen , Traumatismos en Atletas/cirugía , Humanos , Luxaciones Articulares/diagnóstico por imagen , Complicaciones Posoperatorias , Radiografía , Técnicas de Sutura/instrumentación , Tiempo de Tratamiento , Resultado del Tratamiento
5.
Orthop Rev (Pavia) ; 12(Suppl 1): 8681, 2020 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-32913609

RESUMEN

Three-dimensional (3D) printing is a novel modality with the potential to make a huge impact in the surgical field. The aim of this paper is to provide an overview on the current use of 3D printing in shoulder surgery. We have reviewed the use of this new method in 3 fields of shoulder surgery: shoulder arthroplasty, recurrent shoulder instability and orthopedic shoulder traumatology. In shoulder arthroplasty, several authors have shown that the use of the 3D printer improves the positioning of the glenoid component, even if longer clinical follow-up is needed to determine whether the cost of this system rationalizes the potential improved functional outcomes and decreases glenoid revision rates. In the treatment of anterior shoulder instability, the literature agrees on the fact that the use of the 3D printing can: enhance the dept and size of bony lesions, allowing a patient tailored surgical planning and potentially reducing operative times; allow the production of personalized implants to restore substantial bone loss; restore glenohumeral morphology and instability. In orthopedic trauma, the use of 3D printing can be helpful to increase the understanding of fracture patterns, facilitating a more personalized planning, and can be used for resident training and education. We can conclude the current literature regarding the use of 3D printed models in orthopedic surgery agrees finding objective improvements to preoperative planning and to the surgical procedure itself, by shortening the intraoperative time and by the possibility to develop custom-made, patient-specific surgical instruments, and it suggests that there are tangible benefits for its implementation.

6.
Orthop Rev (Pavia) ; 12(Suppl 1): 8682, 2020 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-32913610

RESUMEN

Over the last decade, regenerative medicine has become increasingly popular throughout the scientific community. The poor healing capacity at the tendon-bone interface makes the rotator cuff an appealing target for biologic agents. Adipose derived stem cells are mesenchymal cells with the capacity for self-renewal and multipotential differentiation. They have been recently proposed, both in isolation and as adjuvants to existing surgical therapies, for the treatment of rotator cuff tears. Several studies have been carried out in this research field, starting from the biological characteristics of adipose derived stem cells, their preparation and culture, up to the application in the experimental field on animal models and on humans. The purpose of this study was to provide a state of the art about the current basic science and clinical literature for the effectiveness of adipose derived stem cells in the treatment of rotator cuff tears.

7.
Orthop Rev (Pavia) ; 12(Suppl 1): 8683, 2020 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-32913611

RESUMEN

Chronic shoulder impingement is one of the most common causes of shoulder pain. Intrinsic, extrinsic and secondary factors play a role in this syndrome; however the etiology of the pathology is still under debate. In rare cases, it can be caused by tumors, such as an osteochondroma. In the present study, a 49-year-old patient presented with shoulder pain for 6 months. Initially he underwent conservative treatment, without relief of symptoms. Xrays and MRI were then performed and showed the presence of an exostotic formation on the undersurface of the lateral third of the clavicle. The formation was arthroscopically removed. Histologic examination confirmed the diagnosis of osteochondroma. After surgery, the patient resumed fully activities with no symptoms within 3 months. At 1 year follow up, there are still no clinical or radiological signs of recurrence. This is, to our knowledge, the first case where an arthroscopic approach was used to remove an ostochondroma of the distal third of the clavicle.

8.
Orthop Rev (Pavia) ; 12(Suppl 1): 8687, 2020 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-32913615

RESUMEN

Patients with alkaptonuria can present ochronotic degenerative arthropathy due to the accumulation of pigments in the cartilages. Ochronotic arthropathy initially affects the spine, then there is the involvement of the other large joints, with greater frequency of the knees. In this article we will present two patients with alkaptonuria who have been effectively treated with knee and hip replacement, comparing our experience with what is available in the literature.

9.
Injury ; 51 Suppl 3: S23-S27, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32564965

RESUMEN

INTRODUCTION: Every year more than 300,000 proximal femur fractures are diagnosed. Their number will double within 30 years. In femoral neck fractures treated with hip hemiarthroplasty 90-days mortality is 29.5-51.6%. Haemorrhage is one amongst other complications that is associated with increasing postoperative mortality. Transfusion rate in these patients ranges from 25.7% to 39%. Blood transfusions expose to complications. Fibrin sealants are useful in reducing perioperative need for transfusions, total blood loss, blood loss from drainage. The aim of this study is to assess whether the use of a fibrin sealant during hip hemiarthroplasty implant reduces the need for transfusion. PATIENT AND METHODS: All patients admitted with a proximal femur fracture from September 2018 to May 2019 were reviewed. Inclusion criteria were: femoral neck fracture AO 31B2-3, hip hemiarthroplasty. Exclusion criteria were: previous surgery on the affected hip, coagulation disorders, hematopoietic disorders. Patients were divided in fibrin sealant group and control group. All patients underwent partial hip replacement through a posterolateral approach. 4 ml of fibrin sealant (EVICEL, Omrix Biopharmaceuticals, Diegem, Belgium) were sprayed on the soft tissues of patients included in the fibrin sealant group. Primary outcome of our study was need for perioperative transfusion. Secondary outcomes were: mean red blood cell transfused volume, variations in haematocrit and haemoglobin and total blood volume loss. RESULTS: Eighty-one consecutive patients were enrolled. EVICEL was used on 19 patients, standard haemostatic care on 62 patients. Two patients were transfused in the fibrin sealant group, 22 in the control group (p 0,0371). Mean transfused volume was 21,05 ml in the fibrin sealant group and 116,16 ml in the control group (p 0,0017). No significant difference could be found in haematocrit and haemoglobin variation and total blood loss. DISCUSSION: A reduction in transfusional need with the use of fibrin sealants was reported in studies on total hip arthroplasty and was confirmed by our study. CONCLUSION: EVICEL reduces need for transfusion in patients undergoing hip hemiarthroplasty for a femoral neck fracture. It must be held among the options when a stricter control on transfusional requirement is needed.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Cuello Femoral , Hemiartroplastia , Bélgica , Transfusión Sanguínea , Fracturas del Cuello Femoral/cirugía , Adhesivo de Tejido de Fibrina/uso terapéutico , Humanos , Resultado del Tratamiento
10.
World J Orthop ; 10(2): 63-70, 2019 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-30788223

RESUMEN

Total knee arthroplasty is a common procedure, with extremely good clinical results. Despite this success, it produces 20% unsatisfactory results. Among the causes of these failures is metal hypersensitivity. Metal sensitization is higher in patients with a knee arthroplasty than in the general population and is even higher in patients undergoing revision surgery. However, a clear correlation between metal sensitization and symptomatic knee after surgery has not been ascertained. Surely, patients with a clear history of metal allergy must be carefully examined through dermatological and laboratory testing before surgery. There is no globally accepted diagnostic algorithm or laboratory test to diagnose metal hypersensitivity or metal reactions. The patch test is the most common test to determine metal hypersensitivity, though presenting some limitations. Several laboratory assays have been developed, with a higher sensitivity compared to patch testing, yet their clinical availability is not widespread, due to high costs and technical complexity. Symptoms of a reaction to metal implants present across a wide spectrum, ranging from pain and cutaneous dermatitis to aseptic loosening of the arthroplasty. However, although cutaneous and systemic hypersensitivity reactions to metals have arisen, thereby increasing concern after joint arthroplasties, allergies against implant materials remain quite rare and not a well-known problem. The aim of the following paper is to provide an overview on diagnosis and management of metal hypersensitivity in patients who undergo a total knee arthroplasty in order clarify its real importance.

11.
Knee Surg Sports Traumatol Arthrosc ; 24(12): 3809-3819, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26197937

RESUMEN

PURPOSE: To identify prognostic factors significantly associated with rotator cuff repair outcome and define the strength of these associations. METHODS: Search was performed using electronic databases. Studies reporting prognostic factors affecting rotator cuff repair outcome were included. Primary outcomes were: structural integrity, Disabilities of the Arm, Shoulder and Hand score, American Shoulder and Elbow Surgeons score, and Constant score. Each other outcome was considered as secondary outcome. Descriptive statistics was used. When possible, meta-analyses were performed. Methodological quality was assessed using the Quality In Prognosis Studies Tool. A best evidence synthesis was performed using the Grading of Recommendations Assessment, Development and Evaluation framework adapted to prognostic studies. RESULTS: Sixty-four studies were included. Methodological quality was high only for twelve studies. The overall quality of evidence was low to very low. Meta-analyses were possible only for seven studies. Older age and larger tears size were found to affect retear risk. Results were controversial for fatty infiltration, acromioclavicular joint or biceps procedures, acromiohumeral distance, delamination of tendon edges, musculotendinous junction position, number of tendons involved, and tendon length, quality and retraction. Baseline scores and workers compensation claim predicted functional outcomes. Subjective outcome was also affected by patient's expectations. CONCLUSIONS: Despite the large number of outcomes and prognostic factors evaluated by a relative small number of studies, almost not prognostic in design, it was not possible to reach any definitive conclusion regarding the most relevant predictors of outcome of rotator cuff repair. Moreover, the low methodological quality of the included studies and, subsequently, the low quality of evidence, seriously affected the strength of recommendation of the present review. Based on data available, retear risk is mainly affected by older age and larger tears size. Baseline scores and work compensation claim are the most significant predictors for functional outcomes. LEVEL OF EVIDENCE: Systematic review of level I-IV prognostic studies, Level IV.


Asunto(s)
Lesiones del Manguito de los Rotadores/cirugía , Artroplastia/métodos , Artroscopía/métodos , Humanos , Pronóstico , Manguito de los Rotadores/cirugía , Articulación del Hombro/cirugía , Resultado del Tratamiento
12.
Int Orthop ; 40(11): 2277-2287, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26202017

RESUMEN

PURPOSE: The purpose of this study was to determine the efficacy of surgical and conservative treatment in the prevention of recurrence after primary patellar dislocation. METHODS: Studies were searched on MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials and CINHAL from their inception to April 2015. All randomized controlled clinical trials comparing surgical versus conservative treatment after first patellar dislocation were included. Primary outcomes were: recurrent dislocation, subluxation, overall instability and subsequent surgery. Secondary outcomes included imaging, and subjective and objective clinical assessment tools. Methodological quality of the studies was assessed using Cochrane Collaboration's "Risk of Bias" tool. Pooled analyses were reported as risk ratio (RR) using a random effects model. Continuous data were reported as standardized mean difference (SMD) and 95 % confidence intervals (CIs). Heterogeneity was assessed using I². RESULTS: Nine studies were included in the meta-analyses. Methodological quality of the studies was moderate to low. Meta-analyses showed that surgical treatment significantly reduces the redislocation rate (RR = 0.62; 95% CI = 0.39, 0.98, p = 0.04) and provides better results on Hughston VAS score (SMD = -0.32; 95% CI = -0.61, -0.03; p = 0.03) and running (OR = -0.52; 95% CI = 0.31, 0.88; p = 0.01). Conservative treatment showed less occurrence of minor complications (OR = 3.46; 95% CI = 2.08, 5.77; p = 0.01) and better results in the figure-of-8 run test (SMD = 0.42; 95% CI = 0.06, 0.77; p = 0.02) and in the squat down test (SMD = -0.45; 95% CI = -0.81, -0.10; p < 0.00001). No other significant differences could be found. CONCLUSIONS: Based on the available data, surgical treatment of primary patella dislocation significantly reduces the risk of patella redislocation.


Asunto(s)
Tratamiento Conservador/métodos , Rótula/cirugía , Luxación de la Rótula/terapia , Humanos , Recurrencia , Resultado del Tratamiento
13.
Knee Surg Sports Traumatol Arthrosc ; 23(2): 423-42, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25557222

RESUMEN

PURPOSE: The purpose of this systematic review was to detect the reliability of the currently available magnetic resonance imaging measurements used in the evaluation of repaired rotator cuff. METHODS: Search was performed using major electronic databases from their inception to February 2014. All studies reporting post-operative magnetic resonance assessment after rotator cuff repair were included. After the identification of available magnetic resonance criteria, reliability studies were further analysed. Descriptive statistics were used to summarize findings. Methodological quality was assessed using the Quality Appraisal of Reliability Studies checklist. RESULTS: One hundred and twenty studies were included in the review. Twenty-six different criteria were identified. Ten studies reported inter-observer reliability, and only two assessed intra-observer reliability of some of the identified criteria. Structural integrity was the most investigated criterion. The dichotomized Sugaya's classification showed the highest reliability (k = 0.80-0.91). All other criteria showed moderate to low inter-observer reliability. Tendon signal intensity and footprint coverage showed a complete discordance. Intra-observer reliability was high for the presence of structural integrity, and moderate to low for all other criteria. Methodological quality was high only for one study and moderate for three studies. CONCLUSIONS: Twenty-six different criteria described by multiple classification systems have been identified for the magnetic resonance assessment of rotator cuff after repair. Reliability of most of them has not been analysed yet. With the data available, only the presence of structural integrity showed good intra- and inter-observer agreement. LEVEL OF EVIDENCE: Systematic review of descriptive and qualitative studies, Level IV.


Asunto(s)
Imagen por Resonancia Magnética , Evaluación del Resultado de la Atención al Paciente , Manguito de los Rotadores/patología , Manguito de los Rotadores/cirugía , Tejido Adiposo/patología , Quistes Óseos/patología , Médula Ósea/patología , Edema/patología , Humanos , Atrofia Muscular/patología , Periodo Posoperatorio , Reproducibilidad de los Resultados , Lesiones del Manguito de los Rotadores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA