Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Injury ; 55(11): 111897, 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39321542

RESUMEN

INTRODUCTION: Distal forearm fractures are common in children and adolescents with a spectrum of severity. There are fracture patterns that are suitable for minimal interventions, such as a splint or bandage. The objective of this review was to identify which types of paediatric distal forearm fractures can be safely and effectively managed with a removable splint or bandage. MATERIALS AND METHODS: A scoping review was performed. Databases searched were PubMed, Embase, The Cochrane Library and CINAHL; two trial registries were also searched. All primary study designs with children <18 years of age with a distal forearm fracture that was managed in either a splint or bandage were included. Quality of evidence was determined using the GRADE tool. RESULTS: Twenty-two eligible articles were included from 20 unique studies: 12 randomised controlled trials, seven cohort studies and a case report. Twelve studies focused solely on buckle/torus fractures, with remaining studies including other fracture types, such as incomplete ('greenstick'), complete ('transverse'), or physeal (Salter-Harris). Twelve studies reported that participants with either bandage or splint had appropriate reduction in pain and recovery of function at completion of follow-up for all fracture types. All 20 studies reported minimal adverse events related to fracture management. One study reported worsening angulation with bandage immobilisation for complete fractures in two participants, which required manipulation under anaesthesia. DISCUSSION: There is high quality evidence to support the safety and effectiveness of a splint or bandage for treatment of distal radius buckle and non-displaced incomplete fractures. Several studies supported the use of minimal interventions for various distal radius cortical breach fracture types, with good outcomes, but were limited by heterogeneity (methodology, interventions, outcome measures, reference standard) and potential bias. CONCLUSIONS: Included studies confirmed the inherent stability of buckle fractures. The current literature gap to support minimal interventions for a range of other paediatric distal forearm fracture types was highlighted. High-quality evidence with well-designed, large, multicentre randomised control trials in defined age groups is required to identify which paediatric distal forearm fractures can be safely and effectively managed with either a removable splint or bandage.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39319500

RESUMEN

AIM: Children and their families have reported peripheral intravenous catheter (PIVC) insertion as the most stressful part of their emergency department (ED) encounter, with some enduring multiple attempts without a successful insertion. The purpose of this study was to identify factors associated with abandonment of paediatric PIVC insertion. METHODS: A retrospective cohort study was conducted at the Gold Coast University Hospital. All patients 16 years of age and younger, presented in 2019 with a PIVC insertion attempted in the ED were eligible. The electronic medical records were screened by two reviewers to identify those who required a PIVC insertion. Logistic regression analysis was performed to assess variables associated with PIVC insertion abandonment. RESULTS: Of 6394 records screened, 2401 (8.3%) had a PIVC insertion attempted, with 99 (4.1%) being abandoned. Age <12 months was the strongest predictor of PIVC abandonment at a rate of 11.3% (38/336), with a >10-fold increased risk for infants less than 3 months old and 3-12 months old; adjusted odds ratio (95% confidence interval) 12.4 (5.1-30.2) and 14.8 (5.8-37.4), respectively. Indications of 'infection' or 'rehydration' were associated with a decreased likelihood of abandonment when compared to 'investigation only' in multivariate modelling (odds ratio (95% confidence interval): 0.181 (0.099-0.332) and 0.262 (0.100-0.686), respectively). CONCLUSIONS: This study suggests the rate of PIVC insertion abandonment in children is relatively infrequent. However, more than one in 10 children aged <12 months had PIVC attempts without successful insertion. PIVC abandonment was less likely when there was an indication that necessitated PIVC insertion, such as a serious bacterial infection.

3.
Emerg Med Australas ; 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39099445

RESUMEN

OBJECTIVES: Although it is the most performed invasive procedure, peripheral intravenous catheter (PIVC) insertion in children can be difficult. The primary objective of the study was to identify the factors associated with difficult intravenous access (DIVA) in the paediatric ED, including patient, proceduralist and situational factors. METHODS: This was a single-centre prospective observational cohort study conducted over 28 consecutive days. Research assistants observed PIVC insertion attempts for children under 16 years of age and recorded data for variables relating to the patient, proceduralist and event. Univariate logistic regression modelling was performed to identify factors associated with DIVA, defined as unsuccessful PIVC insertion on the first attempt. RESULTS: A total of 134 participants were recruited; 66 were male (49%) with a median age of 5.7 years. Fifty-two (39%) were classified as having DIVA. There was a total of 207 PIVC insertion attempts with two or more attempts needed for 48 children (36%). Patient factors associated with DIVA included age of 3 years or less and limited vein options. Proceduralist factors included gestalt of 50% or less chance of success, use of a larger gauge (smaller bore) PIVC and less PIVC insertion experience. Situational factors included a combative child, higher pain score and loud ambient noise. CONCLUSIONS: The present study identified multiple patient, proceduralist and situational factors that were associated with DIVA in the paediatric ED. Future studies should explore the development and implementation of a package to address DIVA in children, with the patient-centred goals of reducing pain and improving success.

4.
Med Ultrason ; 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39078993

RESUMEN

Emergency ultrasound, or point-of-care ultrasound (POCUS), has been established into daily patient care over the last decades. The use of abdominal and pelvic ultrasound in clinical practice has the potential to improve the efficiency and safety of pediatric emergency care. This article will provide a review of current applications of pediatric emergency abdominal and urogenital ultrasound, forming the second part of the series.

5.
Australas J Ultrasound Med ; 27(2): 75-88, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38784699

RESUMEN

Purpose: The purpose of this study was to evaluate whether the lung ultrasound (LUS) scores applied to an international cohort of patients presenting to the emergency department (ED) with suspected COVID-19, and subsequently admitted with proven disease, could prognosticate clinical outcomes. Methods: This was an international, multicentre, prospective, observational cohort study of patients who received LUS and were followed for the composite primary outcome of intubation, intensive care unit (ICU) admission or death. LUS scores were later applied including two 12-zone protocols ('de Alencar score' and 'CLUE score'), a 12-zone protocol with lung and pleural findings ('Ji score') and an 11-zone protocol ('Tung-Chen score'). The primary analysis comprised logistic regression modelling of the composite primary outcome, with the LUS scores analysed individually as predictor variables. Results: Between April 2020 to April 2022, 129 patients with COVID-19 had LUS performed according to the protocol and 24 (18.6%) met the composite primary endpoint. No association was seen between the LUS score and the composite primary end point for the de Alencar score [odds ratio (OR) = 1.04; 95% confidence interval (CI): 0.97-1.11; P = 0.29], the CLUE score (OR = 1.03; 95% CI: 0.96-1.10; P = 0.40), the Ji score (OR = 1.02; 95% CI: 0.97-1.07; P = 0.40) or the Tung-Chen score (OR = 1.02; 95% CI: 0.97-1.08). Discussion: Compared to these earlier studies performed at the start of the pandemic, the negative outcome of our study could reflect the changing scenario of the COVID-19 pandemic, including patient, disease, and system factors. The analysis suggests that the study may have been underpowered to detect a weaker association between a LUS score and the primary outcome. Conclusion: In an international cohort of adult patients presenting to the ED with suspected COVID-19 disease who had LUS performed and were subsequently admitted to hospital, LUS severity scores did not prognosticate the need for invasive ventilation, ICU admission or death.

6.
Med Ultrason ; 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38805622

RESUMEN

Point-of-care ultrasound (POCUS) plays an essential role in emergency medicine, providing a range of diagnostic and procedural modalities. It does not involve any ionizing radiation and can improve procedural accuracy and safety. The role of POCUS in the care of pediatric patients differs somewhat from that of adult patients, as there are a range of conditions specific to infants and children. The technical background of pediatric POCUS and its current applications for trauma and thoracic scanning are reviewed and illustrated in this first article of this series.

7.
Lancet Child Adolesc Health ; 8(5): 325-338, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38513681

RESUMEN

BACKGROUND: Sepsis is defined as dysregulated host response to infection that leads to life-threatening organ dysfunction. Biomarkers characterising the dysregulated host response in sepsis are lacking. We aimed to develop host gene expression signatures to predict organ dysfunction in children with bacterial or viral infection. METHODS: This cohort study was done in emergency departments and intensive care units of four hospitals in Queensland, Australia, and recruited children aged 1 month to 17 years who, upon admission, underwent a diagnostic test, including blood cultures, for suspected sepsis. Whole-blood RNA sequencing of blood was performed with Illumina NovaSeq (San Diego, CA, USA). Samples with completed phenotyping, monitoring, and RNA extraction by March 31, 2020, were included in the discovery cohort; samples collected or completed thereafter and by Oct 27, 2021, constituted the Rapid Paediatric Infection Diagnosis in Sepsis (RAPIDS) internal validation cohort. An external validation cohort was assembled from RNA sequencing gene expression count data from the observational European Childhood Life-threatening Infectious Disease Study (EUCLIDS), which recruited children with severe infection in nine European countries between 2012 and 2016. Feature selection approaches were applied to derive novel gene signatures for disease class (bacterial vs viral infection) and disease severity (presence vs absence of organ dysfunction 24 h post-sampling). The primary endpoint was the presence of organ dysfunction 24 h after blood sampling in the presence of confirmed bacterial versus viral infection. Gene signature performance is reported as area under the receiver operating characteristic curves (AUCs) and 95% CI. FINDINGS: Between Sept 25, 2017, and Oct 27, 2021, 907 patients were enrolled. Blood samples from 595 patients were included in the discovery cohort, and samples from 312 children were included in the RAPIDS validation cohort. We derived a ten-gene disease class signature that achieved an AUC of 94·1% (95% CI 90·6-97·7) in distinguishing bacterial from viral infections in the RAPIDS validation cohort. A ten-gene disease severity signature achieved an AUC of 82·2% (95% CI 76·3-88·1) in predicting organ dysfunction within 24 h of sampling in the RAPIDS validation cohort. Used in tandem, the disease class and disease severity signatures predicted organ dysfunction within 24 h of sampling with an AUC of 90·5% (95% CI 83·3-97·6) for patients with predicted bacterial infection and 94·7% (87·8-100·0) for patients with predicted viral infection. In the external EUCLIDS validation dataset (n=362), the disease class and disease severity predicted organ dysfunction at time of sampling with an AUC of 70·1% (95% CI 44·1-96·2) for patients with predicted bacterial infection and 69·6% (53·1-86·0) for patients with predicted viral infection. INTERPRETATION: In children evaluated for sepsis, novel host transcriptomic signatures specific for bacterial and viral infection can identify dysregulated host response leading to organ dysfunction. FUNDING: Australian Government Medical Research Future Fund Genomic Health Futures Mission, Children's Hospital Foundation Queensland, Brisbane Diamantina Health Partners, Emergency Medicine Foundation, Gold Coast Hospital Foundation, Far North Queensland Foundation, Townsville Hospital and Health Services SERTA Grant, and Australian Infectious Diseases Research Centre.


Asunto(s)
Infecciones Bacterianas , Sepsis , Virosis , Humanos , Niño , Estudios de Cohortes , Transcriptoma , Insuficiencia Multiorgánica/diagnóstico , Insuficiencia Multiorgánica/genética , Estudios Prospectivos , Australia , Sepsis/diagnóstico , Sepsis/genética
8.
Australas J Ultrasound Med ; 27(1): 26-41, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38434543

RESUMEN

Introduction/Purpose: Ultrasound is the first-line imaging modality for suspected acute cholecystitis. This can be radiology-performed ultrasound or point-of-care ultrasound (POCUS). POCUS can potentially streamline patient assessment in the emergency department (ED). The primary objective was to evaluate the literature for the diagnostic accuracy of POCUS performed for acute cholecystitis in the ED. Secondary objectives were to assess the effect of POCUS operator training on diagnostic accuracy for acute cholecystitis, utility of POCUS measurement of the common bile duct and POCUS impact on resource utilisation. Methods: A systematic scoping review of articles was conducted using Medline, Embase, CENTRAL and CINAHL. Original studies of adults with POCUS performed for the diagnosis of acute cholecystitis in the ED were included. The study was reported using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews checklist (PRISMA-ScR). Results: A total of 1090 publications were identified. Forty-six met the eligibility criteria. Studies were thematically grouped into categories according to specified objectives. Point-of-care ultrasound was of acceptable but variable accuracy, contributed to by the absence of a consistent reference standard and uniform training requirements. It may positively impact ED resource utilisation through reduced ED length of stay and radiology-performed imaging, whilst improving patient experience. Conclusion: This review highlights the heterogeneity of existing research, emphasising the need for standardisation of training and reference standards in order to precisely define the utility of POCUS for acute cholecystitis in the ED and its benefits on ED resource utilisation.

9.
Ultrasound Med Biol ; 50(6): 898-907, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38519361

RESUMEN

OBJECTIVE: To evaluate the diagnostic accuracy of ultrasound secondary signs of fractures in pediatric patients aged 5-15 y presenting to the emergency department with a clinically non-deformed distal forearm injury. METHODS: This diagnostic study was conducted in South East Queensland, Australia. Emergency clinicians performed point-of-care ultrasound on eligible patients and recorded secondary signs of fractures (pronator quadratus hematoma [PQH] sign, periosteal hematoma, visible angulation) or physeal fractures (fracture-to-physis distance [FPD], physis alteration). The reference standard was the final fracture diagnosis determined by expert panel. The primary outcome was the diagnostic accuracy of secondary signs for cortical breach and physeal fractures. Diagnostic statistics were reported for each relevant secondary sign. RESULTS: A total of 135 participants were enrolled. The expert panel diagnosed 48 "no" fracture, 52 "buckle" fracture and 35 "other" fracture. All "other" fractures were cortical breach fractures and included 15 Salter-Harris II fractures. The PQH sign demonstrated high sensitivity and moderate specificity to diagnose cortical breach fractures (91%, 95% Confidence Interval [CI] 78%-97% and 82%, 73%-88%). Poor sensitivity but high specificity was observed for the visible angulation and periosteal hematoma secondary signs. FPD <1cm showed perfect sensitivity and moderate specificity (100%, 80%-100% and 85%, 78%-90%) for diagnosis of Salter-Harris II fracture. Conversely, physis alteration showed poor sensitivity but excellent specificity (40%, 20%-64% and 99%, 95%-100%) for the diagnosis of Salter-Harris II fractures. CONCLUSION: Ultrasound secondary signs showed good diagnostic accuracy for both cortical breach fractures and Salter-Harris II fractures. Future research should consider optimal use of secondary signs to improve diagnostic accuracy.


Asunto(s)
Ultrasonografía , Humanos , Niño , Femenino , Masculino , Ultrasonografía/métodos , Adolescente , Preescolar , Sensibilidad y Especificidad , Traumatismos del Antebrazo/diagnóstico por imagen , Fracturas del Cúbito/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Prospectivos , Fracturas del Radio/diagnóstico por imagen , Fracturas de la Muñeca
10.
Emerg Med Australas ; 36(4): 579-588, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38481041

RESUMEN

OBJECTIVE: There is substantial practice variation in the management of cellulitis with limited prospective studies describing the course of cellulitis after diagnosis. We aimed to describe the demographics, clinical features (erythema, warmth, swelling and pain), patient-reported disease trajectory and medium-term follow-up for ED patients with cellulitis. METHODS: Prospective observational cohort study of adults diagnosed with cellulitis in two EDs in Southeast Queensland, Australia. Patients with (peri)orbital cellulitis and abscess were excluded. Data were obtained from a baseline questionnaire, electronic medical records and follow-up questionnaires at 3, 7 and 14 days. Clinician adjudication of day 14 cellulitis cure was compared to patient assessment. Descriptive analyses were conducted. RESULTS: Three-hundred patients (mean age 50 years, SD 19.9) with cellulitis were enrolled, predominantly affecting the lower limb (75%). Cellulitis features showed greatest improvement between enrolment and day 3. Clinical improvement continued gradually at days 7 and 14 with persistent skin erythema (41%) and swelling (37%) at day 14. Skin warmth was the feature most likely to be resolved at each time point. There was a discrepancy in clinician and patient assessment of cellulitis cure at day 14 (85.8% vs. 52.8% cured). CONCLUSIONS: A clinical response of cellulitis features can be expected at day 3 with ongoing slower improvement over time. Over one third of patients had erythema or swelling at day 14. Patients are less likely than clinicians to deem their cellulitis cured at day 14. Future research should include parallel patient and clinician evaluation of cellulitis to help develop clearer definitions of treatment failure and cure.


Asunto(s)
Celulitis (Flemón) , Servicio de Urgencia en Hospital , Humanos , Masculino , Estudios Prospectivos , Femenino , Servicio de Urgencia en Hospital/organización & administración , Servicio de Urgencia en Hospital/estadística & datos numéricos , Persona de Mediana Edad , Queensland , Adulto , Anciano , Encuestas y Cuestionarios , Estudios de Cohortes , Estudios de Seguimiento
11.
Ann Emerg Med ; 83(3): 198-207, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37999655

RESUMEN

STUDY OBJECTIVE: In patients aged 5 to 15 years with a clinically nondeformed distal forearm injury presenting to the emergency department (ED), we examined whether point-of-care ultrasound or radiographic imaging had better diagnostic accuracy, with the reference diagnosis determined by an expert panel review. METHODS: This multicenter, open-label, diagnostic randomized controlled trial was conducted in South East Queensland, Australia. Eligible patients were randomized to receive initial imaging through point-of-care ultrasound performed by an ED clinician or radiograph. Images were defined as "no," "buckle," or "other" fracture by the treating clinician. The primary outcome was the diagnostic accuracy of the treating clinician's interpretation compared against the reference standard diagnosis, which was determined retrospectively by an expert panel consisting of an emergency physician, pediatric radiologist, and pediatric orthopedic surgeon, who reviewed all imaging and follow-up. RESULTS: Two-hundred and seventy participants were enrolled, with 135 randomized to each initial imaging modality. There were 132 (97.8%) and 112 (83.0%) correctly diagnosed participants by ED clinicians in the point-of-care ultrasound and radiograph groups, respectively (absolute difference [AD]=14.8%; 95% confidence interval [CI] 8.0% to 21.6%; P<.001). Point-of-care ultrasound had better accuracy for participants with "buckle" fractures (AD=18.5%; 95% CI 7.1% to 29.8%) and "other" fractures (AD=17.1%; 95% CI 2.7% to 31.6%). No clinically important fractures were missed in either group. CONCLUSION: In children and adolescents presenting to the ED with a clinically nondeformed distal forearm injury, clinician-performed (acquired and interpreted) point-of-care ultrasound more accurately identified the correct diagnosis than clinician-interpreted radiographic imaging.


Asunto(s)
Fracturas del Radio , Fracturas de la Muñeca , Adolescente , Niño , Humanos , Servicio de Urgencia en Hospital , Sistemas de Atención de Punto , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/terapia , Estudios Retrospectivos , Ultrasonografía
12.
Australas J Ultrasound Med ; 26(3): 184-190, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37701768

RESUMEN

Introduction/Purpose: Peripheral intravenous catheter (PIVC) insertion can be challenging in children, with point-of-care ultrasound (POCUS) known to increase success rates. The objective of this study was to survey how emergency department (ED) clinicians identify and escalate paediatric patients with difficult intravenous access (DIVA), specifically the use of POCUS. Methods: This cross-sectional study was conducted in an Australian academic mixed ED that surveyed resident medical officers (RMOs), registrars, consultants and senior paediatric nurses. A 15 multiple-choice questionnaire evaluated clinicians experience with paediatric PIVC insertion, approach to identifying and managing DIVA and the use of POCUS or other adjuncts. Results: Eighty clinicians (34.2% response rate) completed the survey. Poor vein palpability was rated the highest predictor of DIVA. Of the respondents, 19 consultants (86.4%), 28 registrars (90.3%) and 16 RMOs (64.0%) used POCUS as an adjunct for paediatric DIVA patients but 16 consultants (72.8%), 21 registrars (67.8%) and 20 RMOs (80.0%) would use this less than 25% of the time in clinical practice. Discussion: This survey suggests more clinicians to prefer using objective factors when identifying paediatric DIVA patients, rather than subjectively using gestalt, which relies on clinician experience. Whilst clearly recognised as a useful tool in our study, POCUS was used infrequently for paediatric DIVA patients. Conclusions: There is currently no consistent process for the identification and escalation of paediatric DIVA patients, including the use of adjuncts such as POCUS. Clinician awareness for these issues should be addressed, which should include the development of guidelines and clinician training in POCUS for PIVC insertion in children.

13.
Emerg Med Australas ; 35(6): 1038-1040, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37704229

RESUMEN

OBJECTIVE: This pilot study compared non-medically trained surf lifesavers' (SLS) ability, after infographic training, to occlude the femoral artery using a pressure point (PP) versus an arterial tourniquet (AT). METHODS: Using a crossover design, eight SLS applied PP and AT to a participant's leg to occlude the femoral artery. Arterial flow, application time and perceived difficulty were recorded. RESULTS: PP achieved 89.7% and 50.8% blood flow reduction for PP and AT, respectively. Average application time was 50.63 and 113.5 s for PP and AT, respectively. Perceived difficulty using a Likert scale from 0 to 10 (0 being no difficulty and 10 being maximal difficulty) was 2.75 and 3.50 for PP and AT, respectively. CONCLUSION: Infographic-trained SLS showed superior blood flow occlusion using PP. This pilot study will inform a larger trial for untrained beachgoers.


Asunto(s)
Extremidad Inferior , Torniquetes , Humanos , Proyectos Piloto , Estudios Cruzados , Hemorragia
15.
J Ultrasound Med ; 42(11): 2525-2534, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37306253

RESUMEN

INTRODUCTION: There is a lack of international consensus as to whether high- or low-level disinfection (HLD or LLD) is required for ultrasound (US) transducers used during percutaneous procedures. This study compared the effectiveness of LLD to HLD on US transducers contaminated with microorganisms from skin. METHODS: Two identical linear US transducers repeatedly underwent either LLD or HLD during the study. Randomization determined which of these transducers was applied to left and right forearms of each participant. Swabs taken from transducers before and after reprocessing were plated then incubated for 4-5 days, after which colony forming units (CFU) were counted and identified. The primary hypothesis was the difference in the proportion of US transducers having no CFUs remaining after LLD and HLD would be less than or equal to the noninferiority margin of -5%. RESULTS: Of the 654 recruited participants 73% (n = 478) had microbial growth from both transducers applied to their left and right forearms before reprocessing. These were included in the paired noninferiority statistical analysis where, after disinfection, all CFUs were eliminated in 100% (95% CI: 99.4-100.0%) of HLD transducer samples (n = 478) and 99.0% (95% CI: 97.6-99.7%) of LLD transducer samples (n = 473). The paired difference in the proportion of transducers having all CFUs eliminated between LLD and HLD was -1.0% (95% CI: -2.4 to -0.2%, P-value <.001). CONCLUSIONS: Disinfection with LLD is noninferior to HLD when microorganisms from skin have contaminated the transducer. Therefore, using LLD for US transducers involved in percutaneous procedures would present no higher infection risk compared with HLD.

16.
Australas J Ultrasound Med ; 26(2): 115-117, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37252628

RESUMEN

We report a young male patient who presented with chest and shoulder tip pain with spontaneous intraperitoneal haemorrhage (haemoperitoneum) due to gastric vessel rupture. Point-of-care ultrasound detected abdominal free fluid, which led to a CT scan of the abdomen and reached the diagnosis. Intra-abdominal bleeding can present as referred chest or shoulder tip pain, as more commonly seen in females with pelvic pathologies. Point-of-care ultrasound may add diagnostic value with the detection of a haemoperitoneum in this context.

17.
N Engl J Med ; 388(22): 2049-2057, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37256975

RESUMEN

BACKGROUND: Data on whether ultrasonography for the initial diagnostic imaging of forearm fractures in children and adolescents is noninferior to radiography for subsequent physical function of the arm are limited. METHODS: In this open-label, multicenter, noninferiority, randomized trial in Australia, we recruited participants 5 to 15 years of age who presented to the emergency department with an isolated distal forearm injury, without a clinically visible deformity, in whom further evaluation with imaging was indicated. Participants were randomly assigned to initially undergo point-of-care ultrasonography or radiography, and were then followed for 8 weeks. The primary outcome was physical function of the affected arm at 4 weeks as assessed with the use of the validated Pediatric Upper Extremity Short Patient-Reported Outcomes Measurement Information System (PROMIS) score (range, 8 to 40, with higher scores indicating better function); the noninferiority margin was 5 points. RESULTS: A total of 270 participants were enrolled, with outcomes for 262 participants (97%) available at 4 weeks (with a window of ±3 days) as prespecified. PROMIS scores at 4 weeks in the ultrasonography group were noninferior to those in the radiography group (mean, 36.4 and 36.3 points, respectively; mean difference, 0.1 point; 95% confidence interval [CI], -1.3 to 1.4). Intention-to-treat analyses (in 266 participants with primary outcome data recorded at any time) produced similar results (mean difference, 0.1 point; 95% CI, -1.3 to 1.4). No clinically important fractures were missed, and there were no between-group differences in the occurrence of adverse events. CONCLUSIONS: In children and adolescents with a distal forearm injury, the use of ultrasonography as the initial diagnostic imaging method was noninferior to radiography with regard to the outcome of physical function of the arm at 4 weeks. (Funded by the Emergency Medicine Foundation and others; BUCKLED Australian New Zealand Clinical Trials Registry number, ACTRN12620000637943).


Asunto(s)
Traumatismos del Antebrazo , Fracturas Óseas , Fracturas de la Muñeca , Adolescente , Niño , Humanos , Australia , Traumatismos del Antebrazo/diagnóstico por imagen , Fracturas Óseas/diagnóstico por imagen , Radiografía , Ultrasonografía , Fracturas de la Muñeca/diagnóstico por imagen , Preescolar , Pruebas en el Punto de Atención
18.
Trials ; 24(1): 366, 2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37254224

RESUMEN

BACKGROUND: Closed reduction of upper limb fractures and/or dislocations are common in the emergency department (ED), which involves physically re-aligning the injured part prior to immobilisation. As this is painful, numerous techniques are available to provide regional anaesthesia to ensure patient tolerance. A Bier block (BB) is typically performed as part of routine care. An alternative technique gaining interest in the ED is ultrasound-guided supraclavicular block (UGSCB), which involves injecting local anaesthetic around the brachial plexus at the supraclavicular fossa under ultrasound guidance. It is unclear whether UGSCB is effective and safe when performed in the ED. METHODS: SUPERB (SUPraclavicular block for Emergency Reduction versus Bier block) is a prospective open-label, non-inferiority randomised controlled trial that compares the effectiveness of UGSCB versus BB for closed reduction of upper limb fractures and/or dislocations. Adult patients presenting with an upper limb fracture and/or dislocation that requires emergent closed reduction in the ED will be eligible. After screening, participants will be randomised to either UGSCB or BB. Once regional anaesthesia is obtained, closed reduction of the injured part will be performed and appropriately immobilised. The primary outcome is maximal pain experienced during closed reduction measured via a visual analogue scale (VAS). Secondary outcomes include baseline and post-reduction pain, patient satisfaction, total opioid requirement in ED, ED length of stay, adverse events and regional anaesthesia failure. DISCUSSION: Existing evidence suggests UGSCB is effective when performed in the operating theatre by trained anaesthetists. SUPERB will be the first randomised controlled trial to elucidate the effectiveness and safety of UGSCB in the ED. The findings have the potential to provide an alternative safe and effective option for the management of upper extremity emergencies in the ED. TRIAL REGISTRATION: This trial has been registered on 21 October 2022 with Australia and New Zealand Clinical Trials Registry (ACTRN12622001356752).


Asunto(s)
Anestesia de Conducción , Fracturas Óseas , Adulto , Humanos , Estudios Prospectivos , Ultrasonografía Intervencional/métodos , Extremidad Superior , Dolor , Ensayos Clínicos Controlados Aleatorios como Asunto
20.
Ultrasound Med Biol ; 49(2): 520-526, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36333153

RESUMEN

Salter-Harris II fractures of the distal radius can result in serious complications. The aim of this study was to measure the fracture-physis distance using point-of-care ultrasound (POCUS) to determine whether a certain distance is associated with Salter-Harris II fractures, compared with other fracture types, in a cohort of children with X-ray-identified distal radius fractures. Participants were from a parent diagnostic study conducted in an Australian tertiary pediatric emergency department, which prospectively evaluated the diagnosis of pediatric distal forearm fractures using POCUS compared against X-ray. Nurse practitioners, who underwent 2 h of training, administered a six-view POCUS protocol in clinically non-angulated pediatric forearm injuries prior to X-ray. This was a secondary analysis of data from the parent study. The 122 participants with X-ray-identified distal radius fractures from the parent study had their POCUS images interpreted by two emergency physician sonologists, who measured the fracture-physis distance. The median and maximum fracture-physis distances for Salter-Harris II fractures (n = 19) were 8.00 and 9.85 mm, whereas minimum and median distances for incomplete fractures (n = 22) were 10.20 and 15.98 mm, and those for complete fractures (n = 9) were 10.85 and 12.85 mm. Buckle fracture (n = 72) distances ranged from 4.35 to 26.55 mm, with a median of 13.65 mm. In children diagnosed with a distal radius fracture on X-ray, a fracture-physis distance cutoff of 1 cm differentiated Salter-Harris II fractures from other cortical breach fracture types, but not buckle fractures. Although this exploratory study suggests the "POCUS 1-cm rule" could be used as a secondary sign to augment the diagnosis of Salter-Harris II distal radius fractures using POCUS, further research is required to validate this measurement prospectively.


Asunto(s)
Fracturas del Radio , Radio (Anatomía) , Humanos , Niño , Sistemas de Atención de Punto , Fracturas del Radio/diagnóstico por imagen , Australia , Radiografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA