1.
Arch Orthop Trauma Surg ; 143(7): 4491-4500, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36357707

RESUMEN

BACKGROUND: While continuous optimization is attempted to decrease the incidence of dislocation after total hip arthroplasty (THA), dislocation remains a major complication. This meta-analysis aims to analyze the evolution of the dislocation risk after primary THA over the decades and to evaluate its potential publication bias. PATIENTS AND METHODS: A systematic search was performed according to the PRISMA guidelines for this meta-analysis in the literature published between 1962 and 2020. MEDLINE, Cochrane and Embase databases were searched for studies reporting the dislocation risk and length of follow-up. Studies that reported on revision rates only and did not mention separate dislocations were excluded. All study designs were eligible. Study quality was assessed by existing quality assessment tools adjusted for arthroplasty research. Overall risk and yearly dislocation rates were calculated and related to historical time frame, study design, sample size and length of follow-up. RESULTS: In total, 174 studies were included with an overall moderate quality. In total there were 85.209 dislocations reported in 5.030.293 THAs, showing an overall dislocation risk of 1.7%, with a median follow-up of 24 months. The overall dislocation risk classified per decade decreased from 3.7% in 1960-1970 to 0.7% in 2010-2020. The yearly dislocation rate decreased from 1.8 to 0.7% within these same decades. There was no significant correlation between the reported dislocation risk and the duration of follow-up (p = 0.903) or sample size (p = 0.755). The reported dislocation risk was higher in articles with registry data compared to other study designs (p = 0.021). CONCLUSION: The dislocation risk in THA has been decreasing over the past decades to 0.7%. Non-selective registry studies reported a higher dislocation risk compared to studies with selective cohorts and RCTs. This indicates that the actual dislocation risk is higher than often reported and 'real-world data' are reflected better in large-scale cohorts and registries.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Luxaciones Articulares , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Falla de Prótesis , Reoperación/efectos adversos , Luxaciones Articulares/complicaciones , Luxación de la Cadera/epidemiología , Luxación de la Cadera/etiología , Diseño de Prótesis
2.
JBJS Rev ; 10(8)2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-36000764

RESUMEN

BACKGROUND: Decreased pelvic mobility and pelvic retroversion may result from spinal degeneration and lead to changes in the orientation of the acetabular implant after total hip arthroplasty (THA). While multiple patient and surgery-related factors contribute to THA dislocations, there is increasing evidence that sagittal spinopelvic dynamics are relevant for THA stability. The aim of this systematic review was to assess the relationship between previously described sagittal spinopelvic characteristics and implant dislocations after primary THA. METHODS: A comprehensive literature search in the PubMed and Embase databases was conducted for studies reporting on spinopelvic morphology, alignment, pathology, or surgery and THA dislocations. Risk of bias was assessed using the MINORS criteria. Because of high heterogeneity in study methodology, a synthesis of best evidence was performed. Odds ratios (ORs), relative risks (RRs), and effect sizes (g) were calculated. RESULTS: Fifteen studies (1,007,900 THAs) with quality scores of 15 to 23 out of 24 were included. Nine different spinopelvic alignment parameters (8 studies, g = 0.14 to 2.02), spinal pathology (2 studies, OR = 1.9 to 29.2), and previous spinal fusion surgery (8 studies, OR = 1.59 to 23.7, RR = 3.0) were found to be related to THA dislocation. Conflicting results were found for another sagittal pelvic morphology parameter, pelvic incidence. CONCLUSIONS: Several sagittal spinopelvic patient characteristics were found to be related to THA dislocation, and the associated risks were greater than for other patient and surgery-related factors. Future research is needed to determine which of those characteristics and parameters should be taken into account in patients undergoing primary THA. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxaciones Articulares , Enfermedades de la Columna Vertebral , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Humanos , Luxaciones Articulares/cirugía , Pelvis/cirugía , Enfermedades de la Columna Vertebral/cirugía
3.
Arch Orthop Trauma Surg ; 141(7): 1253-1259, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33537847

RESUMEN

PURPOSE: Total hip arthroplasty (THA) is a successful procedure. However, in time, heterotopic ossification (HO) can form due to, amongst others, soft tissue damage. This can lead to pain and impairment. This study compares the formations of HO between patients who underwent either THA with the posterolateral approach (PA) or with the direct lateral approach (DLA). Our hypothesis is that patients who underwent THA with a PA form less HO compared to THA patients who underwent DLA. METHODS: In this prospective cohort study, 296 consecutive patients were included who underwent THA. A total of 127 patients underwent THA with the PA and 169 with the DLA. This was dependent on the surgeon's preference and experience. More than 95% of patients had primary osteoarthritis as the primary diagnosis. Clinical outcomes were scored using the Numeric Rating Scale (NRS) and Harris Hip Score (HHS), radiological HO were scored using the Brooker classification. Follow-up was performed at 1 and 6 years postoperatively. RESULTS: Two hundred and fifty-eight patients (87%) completed the 6-year follow-up. HO formation occurred more in patients who underwent DLA, compared to PA (43(30%) vs. 21(18%), p = 0.024) after 6 years. However, the presence of severe HO (Brooker 3-4) was equal between the DLA and PA (7 vs. 5, p = 0.551). After 6 years the HHS and NRS for patient satisfaction were statistically significant higher after the PA (95.2 and 8.9, respectively) compared to the DLA (91.6 and 8.5, respectively) (p < 0.001 and p = 0.003, respectively). The NRS for load pain was statistically significant lower in the PA group (0.5) compared to the DLA group (1.2) (p = 0.004). The NRS for rest pain was equal: 0.3 in the PA group and 0.5 in the DLA group. CONCLUSION: THA with the PA causes less HO formation than the DLA. TRIAL REGISTRATION: Registrated as HipVit trial, NL 32832.100.10, R-10.17D/HIPVIT 1. Central Commission Human-Related research (CCMO) Registry.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osificación Heterotópica/epidemiología , Complicaciones Posoperatorias/epidemiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Humanos , Osteoartritis de la Cadera/cirugía , Estudios Prospectivos
4.
HSS J ; 16(1): 15-22, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32015736

RESUMEN

BACKGROUND: Aseptic loosening, caused by wear and osteolysis, is the most frequent reason for hip replacement revision in the UK. To prevent aseptic loosening, an acetabular component with vitamin E added to irradiated highly cross-linked polyethylene (HXLPE) was developed to reduce oxidative degradation. QUESTIONS/PURPOSES: A prior study of the vitamin E-blended HXLPE acetabular component after 2 years of follow-up reported no adverse reactions or abnormal mechanical behavior. To further examine this hypothesis of reducing wear and osteolysis, we sought to evaluate outcomes after 6-year follow-up. METHODS: A cohort of 95 of the 112 initial patients (84.2%) completed the 6 years of follow-up after receiving a vitamin E-blended HXLPE acetabular component. Evaluation was performed in terms of clinical (visual analog scale [VAS] score, VAS score with weight-bearing, VAS score for satisfaction, and Harris Hip Score) and radiological (inclination, polar gap, radiolucencies, migration, and 2-D linear femoral head penetration rate) assessment. RESULTS: The mean VAS score for patient satisfaction was 8.75 and the mean Harris Hip Score was 91.8. There were two revisions because of deep infections and one because of a peri-prosthetic femoral fracture. Two acetabular components migrated initially; however, delayed acetabular stabilization occurred. Both patients had good clinical scores at 72 months. The mean femoral head penetration rate was 0.036 mm/year. CONCLUSIONS: This prospective cohort study has shown no adverse reactions concerning the vitamin E additive, promising wear rates, no signs of osteolysis, a 100% survival rate for aseptic loosening, and an all-cause survivorship percentage of 97.4% at 6 years of follow-up.

5.
JB JS Open Access ; 3(3): e0063, 2018 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-30533596

RESUMEN

BACKGROUND: Acetabular cup orientation plays a key role in implant stability and the success of total hip arthroplasty. To date, the orientation has been measured with different imaging modalities and definitions, leading to lack of consensus on optimal cup placement. A 3-dimensional (3D) concept involving a trigonometric description enables unambiguous definitions. Our objective was to test the validity and reliability of a 3D trigonometric description of cup orientation. METHODS: Computed tomographic scans of the pelvis, performed for vascular assessment of 20 patients with 22 primary total hip replacements in situ, were systematically collected. On multiplanar reconstructions, 3 observers independently measured cup orientation retrospectively in terms of coronal inclination, sagittal tilt, and transverse version. The angles measured in 2 planes were used to calculate the angle in the third plane via a trigonometric algorithm. For correlation and reliability analyses, intraobserver and interobserver differences between measured and calculated angles were evaluated with use of the intraclass correlation coefficient (ICC). RESULTS: Measured and calculated angles had ICCs of 0.953 for coronal inclination, 0.985 for sagittal tilt, and 0.982 for transverse version. Intraobserver and interobserver reliability had ICCs of 0.987 and 0.987, respectively, for coronal inclination; 0.979 and 0.981, respectively, for sagittal tilt; and 0.992 and 0.978, respectively, for transverse version. CONCLUSIONS: The 3D concept with its trigonometric algorithm is a valid and reliable tool for the measurement of cup orientation. CLINICAL RELEVANCE: By calculating the transverse version of cups from coronal inclination and sagittal tilt measurements, the trigonometric algorithm enables a 3D definition of cup orientation, regardless of the imaging modality used. In addition, it introduces sagittal tilt that, like pelvic tilt, rotates around the transverse axis.