Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Oper Dent ; 49(2): 210-221, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38349816

RESUMEN

OBJECTIVES: This study aimed to evaluate the optical and mechanical performance of two single-shade resin-based composites (RBCs) compared to those of a conventional RBC for restoring posterior teeth. METHODS: Two single-shade RBCs, Omnichroma (Tukoyama) and Vittra Unique APS (FGM), and a conventional RBC, Filtek Z350XT shade A2 (3M Oral Care), were evaluated in this study. The optical shade-matching performance was measured using a spectrophotometer. The light emitted by VALO Grand (Ultradent) and transmitted through the 2.0-mm RBC specimens was evaluated using beam profiling. Knoop hardness (KH, N/mm2), degree of conversion (DC, %) at the top and bottom, flexural strength (FS, MPa), elastic modulus (E, GPa), postgel shrinkage (Shr, %), and shrinkage stress (MPa) were evaluated. Scanning electron microscopy (SEM) was used to characterize the filler. Data for FS, E, and Shr were analyzed by one-way analysis of variance (ANOVA) and KH and DC by repeated one-way ANOVA measurement followed by Tukey test (α=0.05). The modified von Mises stress values, light transmission, and SEM images were analyzed qualitatively. RESULTS: All single-shade RBCs exhibited higher chromatic adaptation than the Filtek Z350XT (p<0.001). Omnichroma exhibited less color difference than Vittra Unique APS, irrespective of the shade. The light transmitted through Omnichroma and Vittra Unique APS increased during polymerization. KH and DC values were significantly reduced from the top to the bottom of the specimens for all RBCs (p<0.001); however, the ratio values were always higher than 80%. In general, all RBCs demonstrated similar mechanical properties. All RBCs exhibited a similar FS (p=0.083) and Shr value (p=0.144). Filtek Z350XT exhibited significantly higher E (p<0.001) than both single-shade RBCs. All RBCs exhibited similar shrinkage stress during restoration and similar residual stress during occlusal loading. CONCLUSIONS: Single-shade Omnichroma and Vittra Unique APS increased light transmission during light-activation, demonstrating better chromatic adaptation than conventional Filtek Z350XT. In general, Omnichroma and Vittra Unique APS exhibited similar mechanical properties and shrinkage stress distributions as Filtek Z350XT during light-activation and occlusal loading.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Estrés Mecánico , Resinas Compuestas/uso terapéutico , Módulo de Elasticidad , Dureza , Ensayo de Materiales , Polimerizacion
2.
Oper Dent ; 49(2): 157-165, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38349817

RESUMEN

OBJECTIVES: To evaluate the volume and depth of enamel loss promoted by 37.5% and 7.5% hydrogen peroxide (HP) gels, and quantify the loss of calcium (Ca) and phosphate (P) ions by using ion chromatography (IC) analysis after bleaching. METHODS: Sixty bovine enamel specimens were randomly divided into three groups: Control - no bleaching gel; HP37.5%, application of HP 37.5% for 45 minutes for 14 days; and HP7.5%, application of HP 7.5% for 3 applications of 8 minutes. The surface analysis (n=5) was performed using a scanning electron microscope (SEM) and dispersive energy system (EDS) to calcium and phosphorus dosage. The micro-CT was used for the enamel loss analysis (n=5). IC was used to analyze extracted Ca and P (n=10). Data were analyzed by one-way ANOVA and two-way repeated measures ANOVA, followed by Tukey and Dunnett's tests (α=0.05). RESULTS: Significantly higher volume and depth of enamel loss were found for bleached groups compared with the control group. HP7.5% had significantly higher enamel change than HP37.5%. SEM showed higher enamel porosity for HP37.5% and HP7.5% compared to control. The IC demonstrated a significant increase of Ca incorporated into the gel, however, only HP7.5% had a higher P presence than the control group. The HP7.5% showed higher Ca and P ion exchange than HP37.5% (p<0.001). CONCLUSION: HP37.5% and HP7.5%, caused enamel mineral changes compared with the control group. The IC method was demonstrated to be an effective methodology for detecting enamel mineral loss by the bleaching gel.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Animales , Bovinos , Calcio , Blanqueamiento de Dientes/métodos , Esmalte Dental , Microtomografía por Rayos X , Peróxido de Hidrógeno/química , Minerales , Fosfatos , Geles
3.
Oper Dent ; 49(2): 136-156, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38349819

RESUMEN

OBJECTIVES: To evaluate the effect of the different radiant exposures from a multipeak light curing unit on the physical and mechanical properties of flowable and high-viscosity bulk-fill resin-based composites (RBC). METHODS: Five flowable bulk-fill RBCs (Tetric N-Flow Bulk-fill, Ivoclar Vivadent; Filtek Bulk Fill Flow, 3M Oral Care; Opus Bulk Fill Flow APS, FGM; Admira Fusion x-base, Voco and; and SDR Plus Bulk Fill Flowable, Dentsply Sirona) and five high-viscosity bulk-fill RBCs (Tetric N-Ceram Bulk-fill, Ivoclar Vivadent; Filtek One Bulk Fill, 3M Oral Care; Opus Bulk Fill APS, FGM; Admira Fusion x-tra, Voco; and SonicFill 2, Kerr) were photo-cured using a VALO Cordless light (Ultradent) for 10, 20, and 40 seconds at an irradiance of 1200, 800, or 400 mW/cm2, resulting in the delivery of 4, 8, 12, 16, 24, 32, or 48 J/cm2. Post-gel shrinkage (Shr) was calculated using strain-gauge test. The degree of conversion (DC, %) was calculated using FTIR. Knoop hardness (KH, N/mm2) and elastic modulus (E, MPa) were measured at the top and bottom surfaces. Logarithmic regressions between the radiant exposures and mechanical properties were calculated. Radiodensity was calculated using digital radiographs. Data of Shr and radiodensity were analyzed using two-way analysis of variance (ANOVA), and the DC, KH, and E data were analyzed with two-way ANOVA using split-plot repeated measurement tests followed by the Tukey test (a = 0.05). RESULTS: Delivering higher radiant exposures produced higher Shr values (p<0.001) and higher DC values (R2=0.808-0.922; R2=0.648-0.914, p<0.001), KH (R2=0.707-0.952; R2=0.738-0.919; p<0.001), and E (R2=0.501-0.925; R2=0.823-0.919; p<0.001) values for the flowable and high-viscosity RBCs respectively. Lower KH, E and Shr were observed for the flowable bulk-fill RBCs. All bulk-fill RBCs had a radiopacity level greater than the 4-mm thick aluminum step wedge. The radiant exposure did not affect the radiopacity. CONCLUSION: The Shr, DC, KH, and E values were highly correlated to the radiant exposure delivered to the RBCs. The combination of the higher irradiance for longer exposure time that resulted in radiant exposure between 24 J/cm2 to 48 J/cm2 produced better results than delivering 400 mW/cm2 for 40 s (16 J/cm2), and 800 mW/cm2 for 20 seconds (16 J/cm2) or 1200 mW/cm2 for 10 seconds (12 J/cm2). All the bulk-fill RBCs were sufficiently radiopaque compared to 4 mm of aluminum.


Asunto(s)
Resinas Acrílicas , Aluminio , Resinas Compuestas , Metacrilatos , Poliuretanos , Siloxanos , Viscosidad , Ensayo de Materiales , Polimerizacion , Materiales Dentales , Propiedades de Superficie
4.
Oper Dent ; 2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37881034

RESUMEN

OBJECTIVES: This study evaluated the Knoop hardness (KH, N/mm2) and degree of conversion (DC, %) on the margins of light-cured resin cements with different photoinitiators using a single light-curing unit (LCU) with two heads (mono- and multiwave). METHODS AND MATERIALS: Three types of resin cements were used with different photoinitiators: Megalink Esthetic (Odontomega, São Paulo, Brazil) with a camphorquinone photoinitiator; Allcem Veneer (FGM, Joinville, Brazil) with the Advanced Polymerization system (APS), and Variolink Esthetic LC (Ivoclar Vivadent, Schaan, Liechtenstein). Thirty samples were collected and divided into six groups (n=5 each). The resin cement samples were made into the shape of a maxillary right central incisor and photoactivated under a 0.5-mm-thick ceramic sheet. A single LCU (Radii Xpert, SDI) with two heads (mono- and multiwave) was used. The tip of the LCU was positioned at the center of the sample in a standardized manner. Raman spectroscopy was performed to evaluate the DC, and KH was evaluated through the Knoop microhardness test. Five regions were evaluated: cervical, mesial, buccal (center), distal, and incisal. RESULTS: There was a significant difference in the DC only for the type of cement (p<0.001), indicating that the cement with the APS photoinitiator presented excellent results. There were significant differences in the type of cement (p<0.001), type of light (p<0.001), region (p<0.001), and the interaction between the type of cement and type of light (p<0.001). The resin cement with the APS photoinitiator cured with monowave light showed the highest KH values. The beam profiles of all groups, with and without the interposition of ceramic and resin cement, were examined by light transmission. CONCLUSIONS: The cement with the APS photoinitiator presented the best results with respect to the DC and KH. In comparison with mono- and multiwaves, the LCU may not be a determining factor for the properties of light-cured resin cements. The buccal region showed the best results for DC and KH, indicating the need for a greater amount of light-curing at the cementation margins.

5.
Oper Dent ; 48(3): 304-316, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36917633

RESUMEN

OBJECTIVES: To analyze the effect of using the resin-based composite manufacturer's recommended exposure time on the degree of conversion (DC), Knoop hardness (KH), and elastic modulus (E) of conventional and bulk-fill resin-based composites (RBCs). METHODS: Three resin-based composites (RBCs) were tested: Tetric EvoCeram Bulk Fill (TET), Opus Bulk Fill APS (OPU), and RBC Vittra APS (VIT). They were photo-activated in 2 mm deep, 6 mm diameter molds for their recommended exposure times of 10 seconds, 20 seconds, or 40 seconds from four light-curing units (LCUs). Two delivered a single emission peak in the blue light region (Optilight Max and Radii-Cal) and two delivered multiple emission peaks in the violet and blue region (VALO Cordless and Bluephase G2). After 24 hours of dry storage at 37°C in the dark, the KH (Kgf/mm2), E (MPa) and DC (%) at the top and bottom surfaces of specimens (n=5) were measured and the results analyzed by 2-way analysis of variance (ANOVA) followed by a Tukey test (α=0.05). RESULTS: The irradiance (mW/cm2) and spectral irradiance (mW/cm2/nm) from the LCUs were reduced significantly (8-35%) after passing through 2.0 mm of RBC (p<0.001). The DC at the bottom of VIT and TET was less than at the top surface (p<0.001). OPU had the same DC at the top and bottom surface (p=0.341). The KH and E values at the top surface of VIT and TET were substantially higher than at the bottom (p<0.001). OPU exposed for 40 seconds achieved higher mechanical properties than TET that was photo-activated for 10 seconds (p<0.001). The opacity of different bulk-fill RBCs changed differently during the polymerization; OPU became more opaque, whereas TET became more transparent. When exposed for their recommended times, the 2 mm thick RBCs that used Ivocerin or the APS photoinitiator system were adequately photo-activated using either the single or multiple emission peak LCUs (p=0.341). CONCLUSION: After 24 hours' storage, all the 2 mm thick RBCs photo-cured in 6 mm diameter molds achieved a bottom-to-top hardness ratio of at least 80% when their recommended exposure times were used. TET, when photo-activated for 10 seconds, achieved lower mechanical properties than OPU that had been photo-activated for 40 seconds. The change in opacity of the RBCs was different during photo-activation.


Asunto(s)
Luces de Curación Dental , Curación por Luz de Adhesivos Dentales , Curación por Luz de Adhesivos Dentales/métodos , Ensayo de Materiales , Materiales Dentales , Resinas Compuestas , Dureza , Polimerizacion , Propiedades de Superficie
6.
Oper Dent ; 48(2): 226-235, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36786761

RESUMEN

OBJECTIVES: This study evaluated the influence of the thickness of disilicate ceramic on the light attenuation (mW/cm2), degree of conversion (DC, %), Knoop hardness (KH, N/mm2) and the elastic modulus (E, MPa) of four luting resins. METHODS: Three resin cements: RelyX Veneer (RV, 3M Oral Care, Monrovia, CA USA); Allcem Veneer APS (AC, FGM); Variolink Esthetic LC (VE, Ivoclar Vivadent, Schaan, Liechtenstein) and one flowable resin composite Tetric N-Flow (TF, Ivoclar Vivadent) were photocured for 20 seconds. The irradiance (mW/cm2) and emission spectrum (mW/cm2/nm) from a broad-spectrum LED light unit (Bluephase G2, Ivoclar Vivadent) were measured over the luting material (control) and through 0.3 mm, 0.7 mm, and 1.0 mm thick ceramic discs (e.max CAD, Ivoclar Vivadent). RESULTS: The LED light delivered 26.1 J/cm2 to the surface and 6.2 J/cm2 through the 1.0 mm thick ceramic. The distribution of violet and blue light across the light tip of the light-curing unit (LCU) was relatively homogeneous, but there was less violet range. The irradiance and spectral radiant power decreased significantly as the ceramic thicknesses increased (p<0.001). The luting material type had significant effect on KH and E values (p<0.001). The RV had the greatest KH and E values, and VE had the lowest. Ceramic thickness had no significant effect on KH (p=0.213) and E (p=0.130). The KH (p=0.265) and E (p=0.165) were also not influenced by the location where these measurements were made across the specimens. No significant reduction of the DC was observed as the ceramic thickness increased (p=0.311). CONCLUSION: Increasing the ceramic thickness exponentially reduced the irradiance. This reduction was more pronounced at the shorter wavelengths (violet) of light, with an 82% decrease for 1 mm-thick ceramic. Increasing the ceramic thickness did not affect the DC, irrespective of photoinitiators used in the tested resins. The position of the violet and blue LEDs within the body of the LCU did not influence KH or E in any of the resins tested. The KH and E of VE were significantly lower than the other 3 luting materials tested.


Asunto(s)
Resinas Compuestas , Porcelana Dental , Módulo de Elasticidad , Dureza , Cerámica , Cementos de Resina , Ensayo de Materiales , Propiedades de Superficie
7.
Oper Dent ; 48(2): 207-217, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36656320

RESUMEN

OBJECTIVE: This study aimed to evaluate the effect of activated charcoal toothpaste on the color stability of teeth subjected to tooth bleaching and pigmenting agents. METHODS: A total of 120 bovine crowns were randomly divided into 12 groups (n=10) according to two study factors: staining solutions (three levels): saliva (control), coffee, and red wine; and toothpaste (four levels): BPC, Bianco Pro Clinical (Bianco Oral Care) (Control); BIW, Black is White (Curaprox); BCA, Bianco Carbon (Bianco Oral Care); and NAT, Natural Suavetex (Suavetex). The samples were subjected to office bleaching with a 35% hydrogen peroxide-based gel (Whiteness HP Blue, FGM), followed by immersion in the solution for 45 minutes per day and daily toothbrushing for 7 days. The color (ΔE) and luminosity changes (ΔL*) were measured using reflectance spectroscopy (Vita EasyShade). The CIE values (L*, a*, b*) were measured at baseline after bleaching (T0) and immediately after immersion in solution each day (Ti1-Ti7) and after all toothbrushing cycles (Tb1-Tb7). ΔE and ΔL were analyzed using a two-way analysis of variance and Tukey's test (α=0.05). The clinically unacceptable level of ΔE > 3.3 was used to evaluate the color change. RESULTS: The color change was significantly influenced by the staining solutions and toothpastes (p<0.001). The color change (ΔE) was significantly higher when immersed in wine than in coffee, and lower ΔE values were observed for artificial saliva (control), irrespective of the toothpaste used. In artificial saliva, BPC, BIW, and BCA resulted in significantly lower ΔE values than NAT, which presented a clinically unacceptable level of dental color change (ΔE>3.3). Coffee resulted in a lower (L*) reduction than wine, irrespective of the toothpaste used. CONCLUSION: Charcoal toothpastes resulted in a color change on the surface of the tooth enamel (ΔE). The bleaching effect of the charcoal toothpastes and control evaluated in this study partially reduced the color changes on the surface of the tooth enamel caused by staining solutions but was unable to reestablish the measured values to the baseline. For teeth immersed in artificial saliva, the color change was not noticeable in BCA, BIW, and control-BPC (ΔE≥3.3), except for NAT, which showed a significant color change.


Asunto(s)
Blanqueamiento de Dientes , Animales , Bovinos , Carbón Orgánico , Café , Color , Saliva Artificial , Blanqueamiento de Dientes/métodos , Pastas de Dientes/química
8.
Oper Dent ; 47(4): 412-424, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35917253

RESUMEN

OBJECTIVES: This study evaluated the influence of irradiance/exposure time on the Knoop hardness (KHN) and polymer cross-linking density (PCLD), as well as microtensile bond strength (µTBS), nanoleakage (NL), and in situ degree of conversion (DC) of universal adhesives. METHODS AND MATERIALS: Two universal adhesive systems, Clearfil Universal Bond Quick (CUQ) and Scotchbond Universal Adhesive (SBU), were light-cured using various irradiance/exposure times: 1400 mW/cm2 for 5 s (1400*5); 1400 mW/cm2 for 10 s (1400*10); 3200 mW/cm2 for 5 s (3200*5); and 3200 mW/cm2 for 10 s (3200*10). Adhesive disks from each group were used to measure PCLD by KHN. One hundred and twenty-eight human molars were randomly assigned to 16 groups according to the following variables: adhesive system vs adhesive strategies vs radiance/exposure times. After restoration, specimens were sectioned into resin-dentin sticks and tested for µTBS, NL, and DC. The data from PCLD (%), KHN, µTBS (MPa), NL (%), and DC (%) data were subjected to ANOVA and Tukey's test (α=0.05). RESULTS: Significant reductions in KHN, µTBS, and DC (p=0.00001) values and an increase in NL and PCLD (p=0.00001) values were observed for 3200*10 when compared with other groups. Higher KHN, µTBS, and DC (p=0.000001) values were observed for 3200*5 in comparison with the other groups. The 1400*5 (7 J/cm2) and 1400*10 (14 J/cm2) groups showed intermediate values (p=0.000001). CONCLUSION: Although similar results in terms of hardness, polymer cross-linking density and nanoleakage were observed when 5 seconds at 3200 mW/cm2 and 10 seconds at 1400 mW/cm2 groups were compared, the use of higher irradiance (3200 mW/cm2) for only 5 seconds showed better results in terms of bond strength and degree of conversion for both universal adhesives to dentin. The prolonged exposure time (10 seconds) at the higher irradiance (3200 mW/cm2) showed the worst results.


Asunto(s)
Recubrimiento Dental Adhesivo , Filtración Dental , Adhesivos , Resinas Compuestas/química , Cementos Dentales/química , Dentina , Recubrimientos Dentinarios/química , Humanos , Ensayo de Materiales , Cementos de Resina/química , Resistencia a la Tracción
9.
Oper Dent ; 47(3): E162-E173, 2022 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35584324

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the mineral content, expressed by calcium (Ca) and phosphate (P), in dental enamel exposed to bleaching agents using micro-computed tomography (micro-CT), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and atomic force microscopy (AFM). METHODS: Sixty bovine dental enamel specimens were randomly divided into three groups (n=20): HP35ca (bleached using 35% hydrogen peroxide with Ca); HP35wca (bleached using 35% hydrogen peroxide without Ca); and control (without bleaching). Five specimens from each group were used for SEM and EDS analyses, 10 specimens were used for AFM analysis, and the remaining five specimens were used for micro-CT analysis. The pH of the gels was measured using a pH meter. The EDS and micro-CT data were analyzed using one-way ANOVA and Pearson's correlation test. The AFM data were analyzed using one-way ANOVA (α=0.05). RESULTS: The weight percentages of Ca and P obtained using EDS were similar between the bleached and control groups. Small, superficial changes were observed by SEM in the HP35wca group. The HP35ca group showed similar patterns to the control group. AFM results showed no significant changes in the enamel roughness in any of the tested groups. No significant difference in the volume or depth of structural enamel loss was found between gels with and without Ca. No mineral loss was observed in the dentin substrate. The EDS and micro-CT analysis data exhibited a high correlation (p<0.001). CONCLUSION: The addition of Ca to the bleaching gel had no beneficial effect on the bleached tooth enamel in terms of composition, mineral loss, and surface roughness. Micro-CT results exhibited a high correlation with the EDS results.


Asunto(s)
Calcio , Esmalte Dental , Microscopía , Espectrometría por Rayos X , Blanqueadores Dentales , Microtomografía por Rayos X , Animales , Calcio/análisis , Calcio/química , Bovinos , Esmalte Dental/química , Esmalte Dental/efectos de los fármacos , Geles/química , Peróxido de Hidrógeno/química , Peróxido de Hidrógeno/farmacología , Microscopía/métodos , Microscopía de Fuerza Atómica , Microscopía Electrónica de Rastreo , Fosfatos/análisis , Distribución Aleatoria , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales/química , Blanqueadores Dentales/farmacología
10.
Oper Dent ; 47(2): 214-224, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35584330

RESUMEN

OBJECTIVE: This study was designed to evaluate the effects of charcoal toothpaste on the surface roughness, color stability, and marginal staining of resin composite restorations. METHODS: A total of 100 bovine incisors was collected. The crowns were sectioned and randomly divided into 10 groups (n=10) according to two study factors: toothpaste groups and nanoparticle resin composite groups. Five toothpastes-Bianco Pro Clinical (Bianco Oral Care, Uberlândia, MG, Brazil) - Control group; Bianco Carbon (Bianco Oral Care); NAT, Natural Suavetex Carvão Ativado (Suavetex, Uberlândia, MG, Brazil); Nano Action Black Be Emotion (Polishop, Jundiaí, SP, Brazil); and BIW, Black is White (Curaprox, Curaden AG, Kriens, Switzerland)-and two resin composites-Z350XT (Filtek Z350XT, 3M Oral Care) and Vittra (Vittra APS FGM, Joinville, SC, Brazil)-were used. Circular cavities with a diameter of 4 mm and a depth of 1 mm were prepared on the buccal face of the tooth crowns and restored with resin composites. The specimens were subjected to three months of simulated toothbrushing. The surface roughness (right angle [Ra], in micrometers [µm]) of the resin composites was measured before and after toothbrushing in five areas per specimen. The resin composite color and luminosity changes (ΔE and ΔL, respectively) were measured using reflectance spectroscopy (Vita EasyShade). Macro photographs were taken before and after toothbrushing to qualitatively analyze the marginal staining (MSt) of the resin composite restorations. Scanning electron microscopy (SEM) was performed before and after the simulated toothbrushing. Ra data were analyzed using two-way analysis of variance with repeated measures and the Tukey HSD test; MSt was analyzed using Kruskal-Wallis and Dunn tests (α=0.05), and the resin composite color change was analyzed using the clinically unacceptable level of ΔE > 3.3. RESULTS: Simulated brushing increased Ra irrespective of the resin composite or toothpaste used. No significant differences were found in Ra between the control group and all groups on which the charcoal toothpastes were tested. A clinically unacceptable level of resin composite color change (ΔE>3.3) was found after the use of most charcoal toothpastes. Use of Bianco Carbon resulted in marginal staining similar to that of the control group and was lower than that of the other charcoal toothpastes. Vittra brushed with black toothpaste showed the highest marginal staining. CONCLUSION: Use of charcoal toothpaste resulted in Ra values of resin composites similar to those found with conventional toothpastes. Charcoal toothpaste generally resulted in clinical resin composite color changes (ΔE). All charcoal toothpastes, except Bianco Carbon, caused marginal staining of the resin composite restorations.


Asunto(s)
Carbón Orgánico , Pastas de Dientes , Animales , Bovinos , Color , Resinas Compuestas/química , Ensayo de Materiales , Coloración y Etiquetado , Propiedades de Superficie , Cepillado Dental/métodos , Pastas de Dientes/química
11.
Oper Dent ; 47(2): 163-172, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35604828

RESUMEN

OBJECTIVE: To evaluate the effect of the sample preparation and light-curing units (LCUs) on the Knoop hardness (KH, N/mm2) and degree of conversion (DC, %) of bulk-fill resin-based composite restorations. METHODS: Two molds were made using human molar teeth embedded in acrylic resin. One was a conventional tooth mold where the molar received a mesio-occluso-distal (MOD) preparation. In the other, the tooth was sectioned in three slices (buccal, middle, and lingual). The center slice received a MOD preparation similar to the conventional mold. Both tooth molds were placed in the second mandibular molar position in a Dentoform with a 44-mm interincisal opening. Restorations were made using Opus Bulk Fill (FGM) high viscosity bulk-fill resin-based composite (RBC) and light cured using two different lights: VALO Cordless (Ultradent) and Bluephase G2 (Ivoclar Vivadent). The RBC was placed in one increment that was light-cured for a total of 80 seconds (40 seconds at the occluso-mesial and occluso-distal locations). The RBC specimens were then prepared as follows: EmbPol - tooth mold specimen was embedded in polystyrene resin and polished before testing; Pol - tooth mold specimen was not embedded, but was polished before testing; NotPol - sectioned tooth mold, specimen not embedded nor polished before testing. The KH was measured in different depths and regions of the specimens, and the DC was measured using Raman spectroscopy. RESULTS: The results were analyzed using a 2-way analysis of variance (ANOVA) or repeated measures followed by the Tukey post-hoc test (α=0.05). The preparation method (p<0.001), depth of restoration (p<0.001), and the interaction between method and depth (p=0.003) all influenced the KH values. Preparation method (p<0.001), tooth region (p<0.001), and the interaction between method and tooth region (p=0.002) all influenced DC values. The KH values were reduced significantly from the top to the bottom of the restorations and also at the proximal box when compared with the occlusal region. This outcome was most significant in the proximal boxes. The NotPol method was the most effective method to detect the effect of differences in KH or DC within the restoration. A lower DC and KH were found at the gingival regions of the proximal boxes of the restorations. When the KH and DC values were compared, there were no significant differences between the LCUs (KH p=0.4 and DC p=0.317). CONCLUSION: Preparation methods that embedded the samples in polystyrene resin and polished the specimens reduced the differences between the KH and DC values obtained by different preparation techniques. The NotPol method was better able to detect differences produced by light activation in deeper areas.


Asunto(s)
Luces de Curación Dental , Curación por Luz de Adhesivos Dentales , Resinas Compuestas/química , Materiales Dentales/química , Dureza , Humanos , Ensayo de Materiales , Polimerizacion , Poliestirenos
12.
Oper Dent ; 47(1): 64-75, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-35090036

RESUMEN

OBJECTIVES: To measure the proximal contact force in newtons (N) between incremental and bulk fill class II resin composite restorations and implant molar teeth or adjacent premolar teeth with simulated periodontal ligament. METHODS: The model used was created with a typodont first molar tooth with two bilateral occlusal-proximal class II cavities, an adjacent tooth simulating an implanted molar tooth (Titamax CM, Neodent, Curtiba, PR, Brazil) and a premolar with simulated periodontal ligament. Two resin composite restorative techniques were used: Inc-Z350XT, (Filtek Z350, 3M Oral Care, St. Paul, MN, USA) inserted incrementally and Bulk-OPUS, (Opus Bulk Fill APS, FGM, Joinville, SC, Brazil) high viscosity bulk fill resin composite (n=10). As a control, a typodont having intact teeth without restorations was used. After the restorative procedure, each specimen was radiographed using a digital system (Dürr Dental, Bietigheim-Bissingen, Germany). The proximal contact force (N) was measured using dental floss with a microtensile machine (Microtensile ODEME, Luzerna, SC, Brazil). The specimens were then subjected to mechanical fatigue cycling to simulate 5 years of aging. All the parameters were measured after aging. The X-rays were blindly qualitatively analyzed by two operators to identify the loss of proximal contact. One-way ANOVA was used for comparing the initial contact force between restored and intact teeth. Two-way ANOVA followed by Tukey testing was performed for contact area data and for the contact force/contact area ratio. The proximal contact force data were analyzed using one-way repeated measurement ANOVA followed by Tukey testing (α=0.05). The X-ray proximal contact analyses were described by the frequency. RESULTS: The initial proximal contact force was similar for intact and restored teeth. The contact force and contact area with the molar were significantly higher than with the premolar; however the contact force/contact area ratio was similar for all tested groups. The bulk fill technique showed a contact force similar to the incremental filling technique. Fatigue resulted in a significant reduction in the proximal contact force (p<0.001), irrespective of the region analyzed or restorative material used. The digital X-rays detected no alteration in the proximal contact after occlusal fatigue. CONCLUSIONS: Larger contact area resulted in higher proximal contact force. Proximal contact force decreased with 5 years of simulated occlusal fatigue. The bulk fill technique showed a proximal contact force similar to that of the incremental filling technique.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Diente Premolar , Brasil , Resinas Compuestas/uso terapéutico , Restauración Dental Permanente/métodos , Ensayo de Materiales , Diente Molar
13.
Oper Dent ; 46(3): 283-292, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34437704

RESUMEN

OBJECTIVES: To correlate the radiant power (mW), radiant exitance (or tip irradiance in mW/cm2), emission spectrum (mW/cm2/nm), and beam irradiance profile of 12 light-curing units (LCUs) available in the Brazilian market with their market cost. METHODS AND MATERIALS: Six LCUs that cost more than US$900 (Bluephase G4,VALO Grand, VALO Cordless, Radii Xpert, Elipar DeepCure-S, and Radii plus) and six low-cost LCUs costing less than US$500 (Radii Cal, Optilight Max, High Power LED 3M, Emitter D, Emitter C, and LED B) were examined. Radiant power (mW) and emission spectrum (mW/nm) were measured using an integrating sphere connected to a fiber-optic spectroradiometer. The internal tip diameter (mm) of each LCU was measured using a digital caliper and was used to calculate the average radiant exitance (mW/cm2). Irradiance profiles at the light tip were measured using a commercial laser beam profiler. The cost of each LCU in Brazil was correlated with internal tip diameter, radiant power, and tip irradiance. RESULTS: None of the low-cost LCUs were broad spectrum multiple peak LCUs. There was no correlation between the cost of the LCUs and their averaged tip irradiance; however, there was a high positive correlation between the cost of the LCUs and the radiant power and tip diameter. The VALO Grand, Elipar DeepCure-S, VALO Cordless, and Bluephase G4 all emitted a higher radiant power. They also had a significantly greater tip diameter than other LCUs. For the LCUs with a nonuniform output, some areas of the light tip delivered less than 400 mW/cm2, while other areas delivered more than 2500 mW/cm2. CONCLUSIONS: In general, LCUs that had a higher cost (US$971-US$1800) delivered more power (mW) and had a greater tip diameter (mm), which covered more of a tooth. In general, the low-cost LCUs (US$224-US$470) emitted a lower radiant power and had a smaller tip diameter.


Asunto(s)
Luces de Curación Dental , Diente , Brasil , Resinas Compuestas , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales
14.
Oper Dent ; 46(2): 197-207, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34192325

RESUMEN

OBJECTIVES: To analyze the effect of the porosity caused by incremental and bulk resin composite filling techniques using low- and high-viscosity composite resins on the biomechanical performance of root-treated molars. METHODS: Forty intact molars received standardized mesio-occlusal-distal (MOD) cavity preparation, were root treated, and randomly divided into four groups with different filling techniques (n=10). The first involved two incremental filling techniques using VIT/Z350XT, a nanofilled composite resin (Filtek Z350XT, 3M ESPE) associated with a resin-modified glass ionomer cement, and resin-modified glass ionomer cement (RMGIC; Vitremer, 3M ESPE) for filling the pulp chamber. The second involved TPH/VIT, a microhybrid composite resin TPH3 Spectrum associated with Vitremer. The third and fourth involved two bulk-fill composite resins: SDR/TPH, a low-viscosity resin composite (Surefill SDR flow, Dentsply) associated with TPH3 Spectrum, and POST, a high-viscosity bulk-fill resin composite (Filtek Bulk Fill Posterior, 3M ESPE). The volume of the porosity inside the restoration was calculated by micro-CT. The cusp deformation caused by polymerization shrinkage was calculated using the strain-gauge and micro-CT methods. The cusp deformation was also calculated during 100 N occlusal loading and loading to fracture. The fracture resistance and fracture mode were recorded. Data were analyzed by one-way analysis of variance and Tukey test. The fracture mode was analyzed by the χ2 test. The volume of the porosity was correlated with the cusp deformation, fracture resistance, and fracture mode (a=0.05). RESULTS: Incremental filling techniques associated with RMGIC resulted in a significantly higher porosity than that of both bulk-fill techniques. However, no significant difference was found among the groups for the fracture resistance, fracture mode, and cusp deformation, regardless of the measurement time and method used. No correlation was observed between the volume of the porosity and all tested parameters. CONCLUSIONS: The porosity of the restorations had no influence on the cuspal deformation, fracture resistance, or fracture mode. The use of the RMGIC for filling the pulp chamber associated with incremental composite resins resulted in similar biomechanical performance to that of the flowable or regular paste bulk-fill composite resin restorations of root-treated molars.


Asunto(s)
Resinas Compuestas , Preparación de la Cavidad Dental , Restauración Dental Permanente , Ensayo de Materiales , Diente Molar , Polimerizacion , Porosidad
15.
Oper Dent ; 45(5): E217-E226, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32352352

RESUMEN

CLINICAL RELEVANCE: The clinician should consider the polymerization shrinkage stress when selecting a composite resin for posterior restorations. The use of post-gel shrinkage values should guide the selection of a composite resin for posterior teeth. SUMMARY: Objectives: The objective of this study was to evaluate the effect of the method used for calculation of polymerization shrinkage, total or post-gel, on the shrinkage stress of conventional and bulk-fill composite resins for restoring endodontically treated teeth using finite element analysis.Methods and Materials: Four composite resins were tested for post-gel shrinkage (P-Shr) by the strain-gauge test and total shrinkage (TShr) using an optical method (n=10). Two conventional composite resins, Filtek Z350 XT (3M-ESPE; Z350) and TPH3 Spectrum (Dents-ply; TPH3) and two bulk-fill composite resins. Filtek Bulk-Fill Posterior (3M-ESPE; POST) SureFil SDR flow (Dentsply; SDR) were tested. Elastic modulus (E), diametral tensile strength (DTS), and compressive strength (CS) were also determined (n=10). The residual shrinkage stress was evaluated by finite element analysis with four restorative techniques: incremental with Z350 and TPH3; SDR/TPH3 (two bulk increments of 4 mm and two occlusal increments); and two bulk increments of 5 mm for POST. Data for P-Shr, T-Shr, E, DTS, and CS were analyzed by analysis of variance and Tukey's test (α=0.05), and residual shrinkage was analyzed quantitatively and qualitatively by the modified von Mises criteria.Results: SDR had the lowest CS values, POST and TPH3 had similar and intermediate values, and Z350 had the highest CS. TPH3 and Z350 had similar DTS values and values higher than SDR. Z350 and POST had higher P-Shr, and SDR had lower T-Shr. T-Shr resulted in higher shrinkage stress than P-Shr values. SDR/TPH3 resulted in higher shrinkage stress when using T-Shr and lower values when using the P-Shr value.Conclusion: T-Shr resulted in higher stress in the enamel and in root dentin close to the pulp chamber than P-Shr values. The selection of the T-Shr or P-Shr changed the ranking of the shrinkage stress of the tested composite resin.


Asunto(s)
Resinas Compuestas , Diente Molar , Análisis del Estrés Dental , Ensayo de Materiales , Polimerizacion , Resistencia a la Tracción
16.
Dent Mater ; 36(3): 468-477, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32005546

RESUMEN

OBJECTIVE: The aim of this study was to investigate the influence of the photoinitiator system on the polymerization kinetics of methacrylamide-based monomers as alternatives to methacrylates in adhesives dental-based materials. METHODS: In total, 16 groups were tested. Monofunctional monomers (2-hydroxyethyl methacrylate) - HEMA; (2-hydroxy-1-ethyl methacrylate) -2EMATE, (2-hydroxyethyl methacrylamide) - HEMAM; and (N-(1-hydroxybutan-2-yl) methacrylamide) -2EM; were combined with bifunctional monomers containing the same polymerizing moieties as the monofunctional counterparts (HEMA-BDI; 2EMATE-BDI; HEMAM-BDI; and 2EM-BDI) at 50/50 M ratios. BHT was used as inhibitor (0.1 wt%) and the photoinitiators used were: CQ + EDMAB (0.2/0.8), BAPO (0.2), IVOCERIN (0.2), and DMPA (0.2), in wt%. The polymerization kinetics were monitored using Near-IR spectroscopy (∼6165 cm-1) in real-time while the specimens were photoactivated with a mercury arc lamp (Acticure 2; 320-500 nm, 300 mW/cm2) for 5 min, and maximum rate of polymerization (Rpmax, in %.s-̄1), degree of conversion at Rpmax (DC@Rpmax, in %), and the final degree of conversion (Final DC, in %) were calculated (n = 3). Initial viscosity was measured with an oscillating rheometer (n = 3). Data were analyzed using Two-way ANOVA for the polymerization kinetics and one-way ANOVA for the viscosity. Multiple comparisons were made using the Tukey's test (∝ = 0.05). RESULTS: There was statistically significant interaction between monomer and photoinitiator (p < 0.001). For the methacrylates groups, the highest Rpmax was observed for HEMA + DMPA and 2EMATE + BAPO. For methacrylamides groups, the highest Rpmax were observed for HEMAM and 2EM, both with DMPA. Final DC was higher for the methacrylate groups, in comparison with methacrylamide groups, independent of the photoinitiators. However, for the methacrylamide groups, the association with BAPO led to the lowest values of DC. In terms of DC@Rpmax, methacrylate-based systems showed significantly higher values than methacrylamide formulations. DMPA and Ivocerin led to higher values than CQ/EDMAB and BAPO in methacrylamide-based compounds. BAPO systems showed de lowest values for both HEMA and HEMAM formulations. For the viscosity (Pa.s), only 2EM had higher values (1.60 ± 0.15) in comparison with all monomers. In conclusion, polymerization kinetics was affected by the photoinitiators for both monomers. Viscosity was significantly increased with the use of secondary methacrylamide. SIGNIFICANCE: this work demonstrated the feasibility of using newly-synthesized methacrylamide monomers in conjunction with a series of initiator systems already used in commercial materials.


Asunto(s)
Cementos Dentales , Metacrilatos , Acrilamidas , Bisfenol A Glicidil Metacrilato , Resinas Compuestas , Ensayo de Materiales , Fotoiniciadores Dentales , Polimerizacion
17.
Dent Mater ; 35(11): 1523-1531, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31395449

RESUMEN

OBJECTIVES: Thiourethane oligomers have been shown to increase the fracture toughness and reduce the polymerization stress of methacrylate-based materials. However, network formation has not been elucidated in these materials yet. The aim of this study was to evaluate how the addition of a thiourethane oligomer (TU) influences the sol/gel composition and network structure of methacrylate-based materials using dynamic mechanical analysis and extraction methods. MATERIALS AND METHODS: BisGMA/TEGDMA at systematically varied mass ratios (20/80 to 80/20wt%) were mixed with pre-polymerized thiourethane oligomers at 0 (control) or 20wt%, synthesized by combining pentaerythritol tetra-3-mercaptopropionate with dicyclohexylmethane 4,4⿲-Diisocyanate, at 1:2 isocyanate:thiol. 0.1wt% of 2,2-Dimethoxy-2-phenylacetophenone was added as the photoinitiator and 0.3wt% of 2,6-di-tert-butyl-4-methylphenol was added as a free radical inhibitor. Disk specimens (0.8ÿ10mm in diameter, n=3) were photoactivated at 270mW/ (320â¿¿500nm) for 1min. The degree of conversion (DC) was measured in near-IR (Ë¿6165cmâ¿¿1). Specimens were immersed in two different solvents (water for 7 days or dicholoromethane for 48h). Water sorption (WS) and solubility (SL) were obtained according to ISO 4049. The leachates for both solutions were analyzed with 1H-NMR (400MHz, CDCL3). Bar specimens (1ÿ3ÿ25mm, photocured and then post-processed at 180°C for 8h to DC>95%) were subjected to dynamic mechanical analysis (â¿¿30 to 230°C) to obtain glass transition temperature (Tg), tan delta curves and crosslinking density (ν). Data was analyzed with two-way ANOVA/Tukeyâ¿¿s test (95%). RESULTS: In general, the presence of TU increased the overall conversion. The WS was similar for all groups, but the SL decreased by 2-fold with the addition of the TU oligomer for all compositions, except BisGMA/TEGDMA 80/20. The BisGMA concentration of the leachates increased with increasing BisGMA in the initial mixture, and with the presence of thiourethane. This compositional drift of the gel with the presence of TU was attributed to the preferential dissolution of TEGDMA into the TU network. Tg and ν decreased with the addition of TU, as expected. The addition of TU produced more homogeneous networks, as evidenced by narrower breadth of the tan delta curve. CONCLUSION: The addition of TU affected the composition of the sol/gel in crosslinked networks, which were more homogeneous and presented 2-fold less potentially toxic leachates than the methacrylate controls. CLINICAL SIGNIFICANCE: The addition of TU may produce less cytotoxic materials based on the increased conversion and reduced amount of unreacted extractables from its network after water storage.


Asunto(s)
Resinas Compuestas , Polímeros , Bisfenol A Glicidil Metacrilato , Módulo de Elasticidad , Ensayo de Materiales , Metacrilatos , Polietilenglicoles , Ácidos Polimetacrílicos , Estrés Mecánico , Uretano
18.
Oper Dent ; 44(6): 637-647, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30702404

RESUMEN

OBJECTIVES: This study evaluated the effect of toothbrushing with a dentifrice on gloss, roughness profile, surface roughness, and wear of conventional and bulk-fill resin-based composites. METHODS AND MATERIALS: Gloss and surface roughness of resin-based composites (RBCs; Admira Fusion X-tra, Aura Bulk Fill, Filtek Bulk Fill Flowable, Filtek Bulk Fill Posterior Restorative, Filtek Supreme Ultra, Herculite Ultra, Mosaic Enamel, SDR flow+, Sonic Fill 2, Tetric EvoFlow Bulk Fill and Tetric EvoCeram Bulk Fill) were analyzed before and after brushing; the roughness profile and wear were also determined after toothbrushing. Representative three-dimensional images of the surface loss and images comparing the unbrushed and brushed surfaces were also compared. Analysis of variance and Tukey post hoc tests were applied (α=0.05) to the gloss, surface roughness, roughness profile, and surface loss data. Pearson's correlation test was used to determine the correlation between gloss and surface roughness, surface loss and percentage of gloss decrease after brushing, and surface loss and surface roughness after brushing. RESULTS: For all RBCs tested after 20,000 brushing cycles, the gloss was reduced and the surface roughness increased (p<0.05). However, the roughness profile and the amount of surface loss were dependent on the RBC brand. Admira Fusion X-tra, Aura, Tetric EvoCeram Bulk Fill, and Tetric EvoFlow Bulk Fill showed the deepest areas of wear (p<0.05). A significant negative correlation was found between gloss and surface roughness, and a weak correlation was found between the decrease in gloss and the extent of surface loss, and any increase in surface roughness and the surface loss. CONCLUSIONS: Toothbrushing with a dentifrice reduced the gloss, increased the surface roughness, and caused loss at the surface of all the RBCs tested. Considering all the properties tested, Mosaic Enamel exhibited excellent gloss retention and a low roughness profile and wear, while Admira Fusion X-tra exhibited the greatest decrease in gloss, the highest roughness profile, and the most wear.


Asunto(s)
Dentífricos , Cepillado Dental , Resinas Compuestas , Materiales Dentales , Ensayo de Materiales , Propiedades de Superficie
19.
Oper Dent ; 44(6): 625-636, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30702411

RESUMEN

OBJECTIVE: To analyze the shrinkage stress, bonding interaction, and failure modes between different low-viscosity bulk fill resin composites and conventional resin composites produced by the same manufacturer or a high-viscosity bulk fill resin composite used to restore the occlusal layer in posterior teeth. METHODS & MATERIALS: Three low-viscosity bulk fill resin composites were associated with the conventional resin composites made by the same manufacturers or with a high-viscosity bulk fill resin composite, resulting in six groups (n=10). The bonding interaction between resin composites was tested by assessing the microshear bond strength (µSBS). The samples were thermocycled and were tested with 1-mm/min crosshead speed, and the failure mode was evaluated. The post-gel shrinkage (Shr) of all the resin composites was measured using a strain gauge (n=10). The modulus of elasticity (E) and the hardness (KHN) were measured using the Knoop hardness test. Two-dimensional finite element models were created for analyzing the stress caused by shrinkage and contact loading. The µSBS, Shr, E, and KHN data were analyzed using the Student t-test and one-way analysis of variance. The failure mode data were subjected to chi-square analysis (α=0.05). The stress distribution was analyzed qualitatively. RESULTS: No significant difference was verified for µSBS between low-viscosity bulk fill resin composites and conventional or high-viscosity bulk fill composites in terms of restoring the occlusal layer (p=0.349). Cohesive failure of the low-viscosity bulk fill resin composites was the most frequent failure mode. The Shr, E, and KHN varied between low-viscosity and high-viscosity resin composites. The use of high-viscosity bulk fill resin composites on the occlusal layer reduced the stress at the enamel interface on the occlusal surface. CONCLUSIONS: The use of high-viscosity bulk fill resin composites as an occlusal layer for low-viscosity bulk fill resin composites to restore the posterior teeth can be a viable alternative, as it shows a similar bonding interaction to conventional resin composites as well as lower shrinkage stress at the enamel margin.


Asunto(s)
Resinas Compuestas , Esmalte Dental , Dureza , Humanos , Ensayo de Materiales , Polimerizacion , Viscosidad
20.
Oper Dent ; 44(3): 289-301, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30444687

RESUMEN

OBJECTIVES: To evaluate the effect of light curing bulk fill resin composite restorations on the increase in the temperature of the pulp chamber both with and without a simulated pulpal fluid flow. METHODS AND MATERIALS: Forty extracted human molars received a flat occlusal cavity, leaving approximately 2 mm of dentin over the pulp. The teeth were restored using a self-etch adhesive system (Clearfil SE Bond, Kuraray) and two different bulk fill resin composites: a flowable (SDR, Dentsply) and a regular paste (AURA, SDI) bulk fill. The adhesive was light cured for 20 seconds, SDR was light cured for 20 seconds, and AURA was light cured for 40 seconds using the Bluephase G2 (Ivoclar Vivadent) or the VALO Cordless (Ultradent) in the standard output power mode. The degree of conversion (DC) at the top and bottom of the bulk fill resin composite was assessed using Fourier-Transform Infra Red spectroscopy. The temperature in the pulp chamber when light curing the adhesive system and resin composite was measured using a J-type thermocouple both with and without the presence of a simulated microcirculation of 1.0-1.4 mL/min. Data were analyzed using Student t-tests and two-way and three-way analyses of variance (α=0.05 significance level). RESULTS: The irradiance delivered by the light-curing units (LCUs) was greatest close to the top sensor of the MARC resin calibrator (BlueLight Analytics) and lowest after passing through the 4.0 mm of resin composite plus 2.0 mm of dentin. In general, the Bluephase G2 delivered a higher irradiance than did the VALO Cordless. The resin composite, LCU, and region all influenced the degree of cure. The simulated pulpal microcirculation significantly reduced the temperature increase. The greatest temperature rise occurred when the adhesive system was light cured. The Bluephase G2 produced a rise of 6°C, and the VALO Cordless produced a lower temperature change (4°C) when light curing the adhesive system for 20 seconds without pulpal microcirculation. Light curing SDR produced the greatest exothermic reaction. CONCLUSIONS: Using simulated pulpal microcirculation resulted in lower temperature increases. The flowable composite (SDR) allowed more light transmission and had a higher degree of conversion than did the regular paste (AURA). The greatest temperature rise occurred when light curing the adhesive system alone.


Asunto(s)
Resinas Compuestas , Luces de Curación Dental , Dentina , Humanos , Ensayo de Materiales , Microcirculación , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA