Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 186
Filtrar
2.
Cureus ; 16(4): e58254, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38745812

RESUMEN

Intraductal papillary neoplasm of the bile duct (IPNB) represents a relatively nascent pathological entity, recognized as a precancerous condition within the spectrum of cholangiocarcinoma. Surgical intervention is advocated for all patients with IPNB due to their susceptibility toward obstructive jaundice, cholangitis, and the heightened likelihood of malignant transformation. Nonetheless, the efficacy of radiation therapy for IPNB cases that are either inoperable or refractory remains inadequately substantiated. Herein, we present a case study of an IPNB patient who declined surgery, and a commendable local control was accomplished solely through the implementation of brachytherapy utilizing Ir-192. A septuagenarian Japanese man presented at our medical institution with the chief complaint of jaundice and was subsequently diagnosed with IPNB. The IPNB lesion extensively spanned from the lower intrapancreatic bile duct to the right (extending to B5/B8) and left bile ducts (up to just before B4). The patient underwent weekly endoscopic retrograde cholangiopancreatography (ERCP) sessions. The prescribed treatment regimen encompassed 36 Gy/6 Fr high-dose-rate brachytherapy (HDR-BT) administered once per week during ERCP, with each treatment session adhering to a timeframe not exceeding two hours. Two months following the initiation of treatment, a biliary endoscopy demonstrated complete resolution of the tumor lesion and amelioration of jaundice. The only observed acute adverse event was grade 2 hepatic dysfunctions. To the best of our knowledge, this represents the first documented instance of HDR-BT employed in IPNB management, suggesting its potential as a viable alternative for inoperable or refractory IPNB cases.

3.
Medicine (Baltimore) ; 103(19): e38161, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38728453

RESUMEN

Chest radiography (CR) has been used as a screening tool for lung cancer and the use of low-dose computed tomography (LDCT) is not recommended in Japan. We need to reconsider whether CR really contributes to the early detection of lung cancer. In addition, we have not well discussed about other major thoracic disease detection by CR and LDCT compared with lung cancer despite of its high frequency. We review the usefulness of CR and LDCT as veridical screening tools for lung cancer and other thoracic diseases. In the case of lung cancer, many studies showed that LDCT has capability of early detection and improving outcomes compared with CR. Recent large randomized trial also supports former results. In the case of chronic obstructive pulmonary disease (COPD), LDCT contributes to early detection and leads to the implementation of smoking cessation treatments. In the case of pulmonary infections, LDCT can reveal tiny inflammatory changes that are not observed on CR, though many of these cases improve spontaneously. Therefore, LDCT screening for pulmonary infections may be less useful. CR screening is more suitable for the detection of pulmonary infections. In the case of cardiovascular disease (CVD), CR may be a better screening tool for detecting cardiomegaly, whereas LDCT may be a more useful tool for detecting vascular changes. Therefore, the current status of thoracic disease screening is that LDCT may be a better screening tool for detecting lung cancer, COPD, and vascular changes. CR may be a suitable screening tool for pulmonary infections and cardiomegaly.


Asunto(s)
Detección Precoz del Cáncer , Neoplasias Pulmonares , Radiografía Torácica , Tomografía Computarizada por Rayos X , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Japón/epidemiología , Radiografía Torácica/métodos , Detección Precoz del Cáncer/métodos , Dosis de Radiación , Enfermedades Torácicas/diagnóstico por imagen , Tamizaje Masivo/métodos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen
4.
Artículo en Inglés | MEDLINE | ID: mdl-38389803

RESUMEN

Objective: Few reports have explored the application of urinary trypsinogen-2 measurement in the early diagnosis of post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis, and none have demonstrated the benefits of noninvasive testing. This study aimed to evaluate the clinical application of the rapid urinary trypsinogen-2 dipstick test (Nipro, Japan) compared with serum amylase and lipase levels for the early diagnosis of post-ERCP pancreatitis (PEP). Methods: A total of 100 consecutive patients (54 men and 46 women) who were admitted and underwent ERCP at Tokyo Medical University Hospital from August 2021 to December 2021 were recruited. All patients underwent rapid urinary trypsinogen-2 measurement using the dipstick test before and after ERCP. Measurements were taken 24 h before ERCP for pre-ERCP and 1-4 h after ERCP for post-ERCP. Additionally, serum amylase and lipase levels were measured at 8:00 a.m. of the day after ERCP (at least 8 h after ERCP), and their diagnostic abilities for PEP were compared and evaluated. Results: PEP occurred in 5/100 patients (5%). The sensitivity, specificity, positive predictive value, and negative predictive value of the dipstick test for diagnosing PEP were 100%, 83.2%, 23.8%, and 100%, respectively. These results were comparable to the diagnostic performance of serum amylase and lipase levels at 8:00 a.m. on the day after ERCP (at least 8 h after ERCP). However, false positives must be considered. Conclusion: The dipstick test may be useful in clinical practice as a noninvasive screening test for the early prediction of PEP.

5.
J Hepatobiliary Pancreat Sci ; 31(5): e17-e19, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38189635

RESUMEN

Bile aspiration during endoscopic ultrasound-guided hepaticogastrostomy reduces the risk of bile leakage. Mukai and colleagues devised a method in which side holes for bile aspiration are created using a biopsy punch in a hard type ultra-tapered bougie dilator. Effective bile aspiration was achieved in all four cases attempted.


Asunto(s)
Dilatación , Endosonografía , Humanos , Dilatación/instrumentación , Dilatación/métodos , Gastrostomía/métodos , Bilis , Masculino , Ultrasonografía Intervencional , Femenino , Anastomosis Quirúrgica , Anciano , Drenaje/métodos , Drenaje/instrumentación , Diseño de Equipo
7.
Diagnostics (Basel) ; 14(2)2024 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-38248007

RESUMEN

For pancreatic masses, an evaluation of their vascularity using contrast-enhanced ultrasonography can help improve their characterization. This study was designed to evaluate the utility and safety of contrast-enhanced transabdominal ultrasonography (CE-TUS) and endoscopic ultrasonography (CE-EUS) in the diagnosis of pancreatic masses including solid or cystic masses. This multi-center comparative open-label superiority study is designed to compare Plain (P)-TUS/EUS alone with P-TUS/P-EUS plus CE-TUS/CE-EUS. Three hundred and one patients with a total of 232 solid pancreatic masses and 69 cystic masses were prospectively enrolled. The primary endpoints are to compare the diagnostic accuracy between P-TUS/P-EUS alone and P-TUS/P-EUS plus CE-TUS/CE-EUS for both the TUS and EUS of solid pancreatic masses, and to compare the diagnostic accuracy between P-EUS alone and P-EUS plus CE-EUS in cystic pancreatic masses. The secondary endpoints are to compare the diagnostic sensitivity and specificity of P-TUS/P-EUS alone and P-TUS/P-EUS plus CE-TUS/CE-EUS for pancreatic solid/cystic masses, and the accuracy of P-TUS alone and P-TUS plus CE-TUS for pancreatic cystic masses. Other secondary endpoints included comparing the diagnostic sensitivity, specificity, and accuracy of CE-TUS, CE-EUS and CE-computed tomography (CT) for solid/cystic pancreatic masses. The safety, degree of effective enhancement, and diagnostic confidence obtained with CE-TUS/CE-EUS will also be assessed.

8.
J Hepatobiliary Pancreat Sci ; 31(2): 120-132, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37907717

RESUMEN

BACKGROUND/PURPOSE: Afferent loop syndrome (ALS) is a rare adverse event after gastrointestinal surgery requiring appropriate early decompression treatment. Several endoscopic interventions have been attempted for treatment, including endoscopic enteral metal stent placement (EMSP), endoscopic ultrasound (EUS)-guided entero-enterostomy (EUS-EE), and EUS-guided hepaticogastrostomy (EUS-HGS). However, there are limited data on outcomes, including duration of stent patency. In this study, we evaluated the usefulness of each endoscopic intervention for malignant ALS. METHODS: We retrospectively investigated nine patients with malignant ALS who underwent EMSP, EUS-EE, or EUS-HGS. Information on technical success, clinical efficacy, adverse events, stent dysfunction, and overall survival was collected and analyzed. RESULTS: The most common symptoms were abdominal pain and cholangitis. ALS was treated by EMSP in three patients, EUS-EE in three patients, and EUS-HGS in three patients. Stent placement was successful and clinically effective in all patients with no adverse events. During follow-up, stent dysfunction occurred in two patients treated by EUS-HGS. Eight patients died of primary disease during a median follow-up of 157 days. CONCLUSIONS: Each of the available endoscopic interventions for malignant ALS can be expected to produce similar outcomes, including duration of stent patency. The choice of endoscopic intervention should be made based on the characteristics of each treatment.


Asunto(s)
Síndrome del Asa Aferente , Colestasis , Humanos , Síndrome del Asa Aferente/diagnóstico por imagen , Síndrome del Asa Aferente/etiología , Síndrome del Asa Aferente/cirugía , Colestasis/etiología , Drenaje , Endoscopía , Endosonografía , Hígado/patología , Estudios Retrospectivos , Stents/efectos adversos , Resultado del Tratamiento
9.
Gastrointest Endosc ; 99(1): 50-60, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37562548

RESUMEN

BACKGROUND AND AIMS: Bilioenteric anastomotic stricture (BES) is a well-known adverse event after bilioenterostomy. Recently, EUS-guided antegrade intervention (EUS-AI) has been developed for cases that are difficult to treat by balloon enteroscopy-assisted ERCP. However, no data are available on the long-term outcomes after EUS-AI. The main goal of the present study was to clarify the long-term outcomes of EUS-AI in such patients. METHODS: Between November 2013 and November 2021, 34 patients who were followed for more than 1 year after EUS-AI for BES were identified. The primary endpoint was the rate of stricture resolution. Secondary endpoints were factors associated with stricture resolution, rate of BES recurrence, rate of conversion to surgery, and rate of hepatic fibrosis progression during follow-up. RESULTS: The median follow-up period was 56.7 months. Stricture resolution was achieved in 17 of 34 patients (50%). A multivariate analysis confirmed that the presence of bile duct stones (odds ratio, 9.473; 95% confidence interval, 1.66-53.98; P = .01) was significantly associated with stricture resolution. The stricture recurrence rate was 33%, and the median time from stent removal to recurrence was 31.2 months. Four patients underwent surgery because of recurrent cholangitis. During the median follow-up period of 56.7 months, 25% progressed to hepatic fibrosis based on the Fibrosis-4 index grade. Interestingly, patients without cholangitis during follow-up did not show progression of hepatic fibrosis. CONCLUSIONS: EUS-AI has achieved acceptable long-term clinical outcomes. EUS-AI can be a viable alternative treatment of choice before surgical treatment in patients who are difficult to treat by conventional approaches.


Asunto(s)
Colangitis , Humanos , Constricción Patológica/etiología , Constricción Patológica/cirugía , Estudios Retrospectivos , Colangitis/etiología , Stents/efectos adversos , Cirrosis Hepática , Colangiopancreatografia Retrógrada Endoscópica , Resultado del Tratamiento
10.
Medicine (Baltimore) ; 102(44): e35701, 2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37933064

RESUMEN

INTRODUCTION: In median arcuate ligament syndrome (MALS), the celiac artery is compressed, causing an arcade to develop in the pancreatic head, leading to ischemic symptoms and aneurysms. PATIENT CONCERNS: The patient was diagnosed with borderline resectable pancreatic cancer (PC) and MALS. Endoscopic biliary drainage with a covered metal stent (CMS) was performed for the obstructive jaundice. After the jaundice improved, a modified FOLFIRINOX regimen was initiated. Several days later, cardiopulmonary arrest occurred after hematemesis occurred. Cardiopulmonary resuscitation was performed, his blood pressure stabilized, and emergent upper endoscopy was performed. The CMS was dislodged and active bleeding was observed in the papillae. The CMS was replaced, and temporary hemostasis was achieved. Contrast-enhanced computed tomography revealed a diagnosis of extravasation from the posterior superior pancreaticoduodenal artery (PSPDA) into the biliary tract. Transcatheter arterial embolization was performed. However, the patient was subsequently diagnosed with hypoxic encephalopathy and died on day 14 of hospitalization. DIAGNOSIS: Biliary hemorrhage due to invasion of pancreatic cancer from the PSPDA associated with MALS. INTERVENTION: None. OUTCOMES: Biliary hemorrhage from the PSPDA was fatal in the patient with invasive PC with MALS. LESSONS: Since MALS associated with PC is not a rare disease, the purpose of this study was to keep in mind the possibility of fatal biliary hemorrhage.


Asunto(s)
Hemobilia , Síndrome del Ligamento Arcuato Medio , Neoplasias Pancreáticas , Humanos , Protocolos de Quimioterapia Combinada Antineoplásica , Hemobilia/etiología , Hemorragia/complicaciones , Síndrome del Ligamento Arcuato Medio/diagnóstico , Neoplasias Pancreáticas/complicaciones , Neoplasias Pancreáticas
11.
Endosc Ultrasound ; 12(2): 251-258, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37148137

RESUMEN

Background and Objectives: EUS-guided tissue acquisition is routinely performed for the diagnosis of gastrointestinal tract and adjacent organ lesions. Recently, various types of needles have been developed. However, how the shape of the needle tip and echoendoscope tip angle affect puncturability, has not been clarified. The aim of this experimental study was to compare the puncturability of several 22-gauge EUS-FNA and EUS-guided fine-needle biopsy (EUS-FNB) needles, and to evaluate the effects of the needle tip shape and echoendoscope tip angle on tissue puncturability. Materials and Methods: The following six major FNA and FNB needles were evaluated: SonoTip® ProControl, EZ Shot 3 Plus, Expect™ Standard Handle, SonoTip® TopGain, Acquire™, and SharkCore™. The mean maximum resistance force against needle advancement was evaluated and compared under several conditions using an echoendoscope. Results: The mean maximum resistance force of the needle alone was higher for the FNB needles than for the FNA needles. The mean maximum resistance force of the needle in the echoendoscope with free angle demonstrated that the resistance forces were between 2.10 and 2.34 Newton (N). The mean maximum resistance force increased upon increases in angle of the tip of echoendoscope, particularly in the FNA needles. Among the FNB needles, SharkCore™ had the lowest resistance force (2.23 N). The mean maximum resistance force of the needle alone, the needle in the echoendoscope with free angle, and the needle in the echoendoscope with full-up angle for SonoTip® TopGain were all similar to that of Acquire™. Conclusion: SonoTip® TopGain had similar puncturability to Acquire™ in all tested situations. Regarding the puncturability, SharkCore™ is most suitable for insertion into target lesions, when tight echoendoscope tip angle is necessary.

12.
J Hepatobiliary Pancreat Sci ; 30(7): 983-992, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36458423

RESUMEN

BACKGROUND/PURPOSE: EUS-guided biliary drainage (EUS-BD) has recently been reported to be a useful salvage technique after ERCP fail. However, data on EUS-BD used for preoperative biliary drainage (PBD) are limited. The aim of this study was to verify the clinical feasibility of EUS-BD for PBD. METHODS: PBD was performed for malignant biliary obstruction in 318 patients at our institution between July 2014 and April 2022. Fifteen (4.7%) of these patients underwent surgical resection after preoperative EUS-BD (HGS 13; HDS 1; AGS with HGS 1) and were retrospectively analyzed. RESULTS: The stent was successfully placed in all 15 cases with a median procedure time of 15 min (technical success rate 100%). The median total bilirubin value decreased significantly from 3.7 before drainage to 0.9 after surgery (p < .001) and cholangitis was well managed (clinical success rate 100%). Surgery was performed at a median of 22 days after drainage, and there were no stent-related adverse events or recurrences of biliary obstruction. Severe surgery-related adverse events occurred in three cases, but none were associated with EUS-BD. The stent was removed during surgery in 12 cases. CONCLUSIONS: EUS-BD can be a feasible and safe alternative method of PBD for malignant biliary obstruction after ERCP fail.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Colestasis , Humanos , Estudios Retrospectivos , Estudios de Factibilidad , Colangiopancreatografia Retrógrada Endoscópica/métodos , Colestasis/diagnóstico por imagen , Colestasis/etiología , Colestasis/cirugía , Drenaje/métodos , Ultrasonografía Intervencional , Endosonografía/métodos , Stents/efectos adversos
13.
J Hepatobiliary Pancreat Sci ; 30(3): 351-359, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35918909

RESUMEN

BACKGROUND/PURPOSE: Shear wave elastography (SWE) is a clinical method used to evaluate liver hardness. In this study, we assessed its applicability in assessing the pancreas and its potential for diagnosing chronic pancreatitis. METHODS: We performed SWE on 59 patients who underwent abdominal ultrasound, and measured the computed tomography (CT) values of the pancreas. Patients were classified as having a normal pancreas (NP), early chronic pancreatitis (ECP), or chronic pancreatitis (CP). SW elasticity (SWe), SW dispersion (SWd), and CT values between groups were analyzed. RESULTS: SWe significantly differed between the CP and NP/ECP groups (NP vs CP; P = 0.001, ECP vs CP; P = 0.026,), while SWd showed a significant difference only between the NP and CP group (NP vs CP; P = 0.001). The CT values were significantly different between the CP and NP/ECP groups (NP vs CP; P = 0.0006, ECP vs CP; P = 0.0027). CONCLUSION: Pancreatic SWE and CT values were helpful in the diagnosis of chronic pancreatitis. SWd may reveal status changes in ECP.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Pancreatitis Crónica , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Pancreatitis Crónica/diagnóstico por imagen , Páncreas/diagnóstico por imagen , Ultrasonografía , Hígado
14.
Dig Endosc ; 35(1): 47-57, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35702927

RESUMEN

Urgent or emergency endoscopic retrograde cholangiopancreatography (ERCP) is indicated for gallstone-induced acute cholangitis and pancreatitis. The technique and optimal timing of ERCP depend on the disease state, its severity, anatomy, patient background, and the institutional situation. Endoscopic transpapillary biliary drainage within 24 h is recommended for moderate to severe acute cholangitis. The clinical outcomes of biliary drainage with nasobiliary drainage tube placement and plastic stent placement are comparable, and the choice is made on a case-by-case basis considering the advantages and disadvantages of each. The addition of endoscopic sphincterotomy (EST) is basically not necessary when performing drainage alone, but single-session stone removal following EST is acceptable in mild to moderate cholangitis cases without antithrombotic therapy or coagulopathy. For gallstone pancreatitis, early ERCP/EST are recommended in cases with impacted gallstones in the papilla. In some cases of gallstone pancreatitis, a gallstone impacted in the papilla has already spontaneously passed into the duodenum, and early ERCP/EST lacks efficacy in such cases, with unfavorable findings of cholangitis or cholestasis. If it is difficult to diagnose the presence of gallstones impacted in the papilla on imaging, endoscopic ultrasonography can be useful in determining the indication for ERCP.


Asunto(s)
Colangitis , Cálculos Biliares , Pancreatitis , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Cálculos Biliares/diagnóstico , Cálculos Biliares/diagnóstico por imagen , Esfinterotomía Endoscópica/métodos , Colangitis/diagnóstico , Colangitis/etiología , Colangitis/cirugía , Pancreatitis/complicaciones , Pancreatitis/diagnóstico , Enfermedad Aguda
15.
J Hepatobiliary Pancreat Sci ; 30(3): 401-407, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36043228

RESUMEN

BACKGROUND/PURPOSE: A peroral cholangioscope (POCS) can allow direct visualization of the biliary mucosa and its use is becoming more widespread due to improvements in functionality, image quality, and operability, as well as the development of related devices. Recently, a novel mother-baby peroral cholangioscope (nMB-POCS) with a large (2-mm) accessory channel has been developed. In this study, we evaluated the feasibility of this novel POCS in a dry simulation and animal model. METHODS: We evaluated the ease of insertion and maneuverability of the nMB-POCS, the image quality, and the passage of the devices into the accessory channel and into the common bile duct in a dry and live porcine model. RESULTS: In both models, the nMB-POCS could be easily inserted into the duodenoscope and into the distal bile duct and hilum. The image quality was good, and it was possible to observe the surface structure and the vascular network of the bile duct mucosa in detail. CONCLUSIONS: The nMB-POCS with its larger accessory channel is expected to improve the efficiency of diagnosis and  treatment, and reduce the procedure time. Clinical studies in patients are warranted.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Biliar , Laparoscopía , Animales , Porcinos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Conductos Biliares , Conducto Colédoco
16.
J Hepatobiliary Pancreat Sci ; 30(4): e20-e21, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36048175

RESUMEN

This paper discusses a novel tube placement technique; the "spinning lasso method", in EUS-guided drainage for small pancreatic pseudocysts (PC) with video. In general, the placement of a drainage tube can be difficult in a small PC and the tube often deviates during attempted insertions into the cavity. The technique helps to mitigate this problem.


Asunto(s)
Seudoquiste Pancreático , Humanos , Seudoquiste Pancreático/diagnóstico por imagen , Seudoquiste Pancreático/cirugía , Endosonografía/métodos , Drenaje/métodos , Stents
17.
Artículo en Inglés | MEDLINE | ID: mdl-36224458

RESUMEN

There is a tremendous need for prevention and effective treatment of cancer due to the associated morbidity and mortality. In this study, we introduce sonodynamic therapy (SDT), which is expected to be a new cancer treatment modality. SDT is a promising option for minimally invasive treatment of solid tumors and comprises three different components: sonosensitizers, ultrasound, and molecular oxygen. These components are harmless individually, but in combination they generate cytotoxic reactive oxygen species (ROS). We will explore the molecular mechanism by which SDT kills cancer cells, the class of sonosensitizers, drug delivery methods, and in vitro and in vivo studies. At the same time, we will highlight clinical applications for cancer treatment. The progress of SDT research suggests that it has the potential to become an advanced field of cancer treatment in clinical application. In this article, we will focus on the mechanism of action of SDT and its application to cancer treatment, and explain key factors to aid in developing strategies for future SDT development.

18.
Artículo en Inglés | MEDLINE | ID: mdl-35551555

RESUMEN

Pancreatic cancer (PC) has one of the poorest prognoses among solid cancers, and its incidence has increased recently. Satisfactory outcomes are not achieved with current therapies; thus, novel treatments are urgently needed. High-intensity focused ultrasound (HIFU) is a novel therapy for ablating tissue from the outside of the body by focusing ultrasonic waves from multiple sources on the tumor. In this therapy, only the focal area is heated to 80-100 ºC, which causes coagulative necrosis of the tissue, with hardly any impact on the tissue outside the focal area. Although HIFU is a minimally invasive treatment and is expected to be useful, it is not yet generally known. Here, we discuss the usefulness of HIFU treatment for un-resectable advanced PC using the results of previous research, meta-analyses, and systematic reviews on its efficacy and safety. HIFU therapy for un-resectable PC is useful for its anti-tumor effect and pain relief, and is expected to prolong survival time and improve quality of life. Although HIFU for PC has several limitations and further study is needed, this technique can be safely performed on un-resectable advanced PC. In future, HIFU could be utilized as a minimally invasive treatment strategy for PC patients with a poor prognosis.

19.
J Hepatobiliary Pancreat Sci ; 29(6): e57-e58, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35302713

RESUMEN

Highlight Interventional endoscopic ultrasound has become widely used although it remains challenging. Nagai and colleagues present the first case of single-session endoscopic ultrasound-guided hepaticogastrostomy and endoscopic ultrasound-guided pancreatic duct drainage, and demonstrate that it is feasible for the management of biliary and pancreatic duct stones in patients with surgically altered anatomy.


Asunto(s)
Enfermedades Pancreáticas , Stents , Drenaje , Endosonografía , Humanos , Enfermedades Pancreáticas/complicaciones , Enfermedades Pancreáticas/diagnóstico por imagen , Enfermedades Pancreáticas/cirugía , Conductos Pancreáticos/diagnóstico por imagen , Conductos Pancreáticos/cirugía , Ultrasonografía Intervencional
20.
J Hepatobiliary Pancreat Sci ; 29(7): 817-824, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35030302

RESUMEN

BACKGROUND/PURPOSE: Although the lumen-apposing metal stent (LAMS) is useful for interventional endoscopic ultrasound (EUS) procedures, there has been some concern about the potential for stent-induced adverse events because of the high lumen-apposing force. A newly designed LAMS with less lumen-apposing force has been developed for use with a physician-controlled electrocautery-enhanced delivery system. The aim of this animal study was to evaluate the feasibility of performing interventional EUS using this newly designed LAMS system. METHODS: Endoscopic ultrasound-guided cystogastrostomy was performed using the novel LAMS three times in a wet simulation model. EUS-guided gastroenterostomy and EUS-guided gallbladder drainage were then performed using the system in four pigs. RESULTS: The LAMS was successfully placed in all three EUS-guided cystogastrostomy procedures using the wet simulation model and in all four EUS-guided gastroenterostomy and gallbladder drainage procedures in the animal model. In the 3 weeks following the procedure, eating behavior was normal in all animals and there were no adverse events. The stents remained patent during this time and were removed without difficulty. The fistula was mature in all cases and a standard upper gastrointestinal endoscope was easily advanced via the fistula to observe the afferent and efferent loops or the lumen of the gallbladder. Necropsy confirmed complete adhesion between the stomach and the wall of the jejunum or gallbladder. CONCLUSIONS: Our study findings demonstrate the feasibility of this new LAMS system and its potential clinical value for interventional EUS.


Asunto(s)
Anastomosis Quirúrgica , Electrocoagulación , Endosonografía , Implantación de Prótesis , Stents , Ultrasonografía Intervencional , Anastomosis Quirúrgica/instrumentación , Anastomosis Quirúrgica/métodos , Animales , Fístula del Sistema Digestivo/etiología , Fístula del Sistema Digestivo/cirugía , Drenaje/instrumentación , Drenaje/métodos , Electrocoagulación/instrumentación , Electrocoagulación/métodos , Endosonografía/instrumentación , Endosonografía/métodos , Vesícula Biliar/cirugía , Yeyuno/cirugía , Modelos Animales , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Estómago/cirugía , Porcinos , Ultrasonografía Intervencional/instrumentación , Ultrasonografía Intervencional/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA