Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 9(7)2020 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-32660070

RESUMEN

PURPOSE: To compare the reliability of five different intraoral scanners (IOSs) in the capture of implant scanbodies (SBs) and to verify the dimensional congruence between the meshes (MEs) of the SBs and the corresponding library file (LF). METHODS: A gypsum cast of a fully edentulous maxilla with six implant analogues and SBs screwed on was scanned with five different IOSs (PRIMESCAN®, CS 3700®, MEDIT i-500®, ITERO ELEMENTS 5D®, and Emerald S®). Ten scans were taken for each IOS. The resulting MEs were imported to reverse engineering software for 3D analysis, consisting of the superimposition of the SB LF onto each SB ME. Then, a quantitative and qualitative evaluation of the deviations between MEs and LF was performed. A careful statistical analysis was performed. RESULTS: PRIMESCAN® showed the highest congruence between SB MEs and LF, with the lowest mean absolute deviation (25.5 ± 5.0 µm), immediately followed by CS 3700® (27.0 ± 4.3 µm); the difference between them was not significant (p = 0.1235). PRIMESCAN® showed a significantly higher congruence than MEDIT i-500® (29.8 ± 4.8 µm, p < 0.0001), ITERO ELEMENTS 5D® (34.2 ± 9.3 µm, p < 0.0001), and Emerald S® (38.3 ± 7.8 µm, p < 0.0001). CS 3700® had a significantly higher congruence than MEDIT i-500® (p = 0.0004), ITERO ELEMENTS 5D® (p < 0.0001), and Emerald S® (p < 0.0001). Significant differences were also found between MEDIT i-500® and ITERO ELEMENTS 5D® (p < 0.0001), MEDIT i-500® and Emerald S® (p < 0.0001), and ITERO ELEMENTS 5D® and Emerald S® (p < 0.0001). Significant differences were found among different SBs when scanned with the same IOS. The deviations of the IOSs showed different directions and patterns. With PRIMESCAN®, ITERO ELEMENTS 5D®, and Emerald S®, the MEs were included inside the LF; with CS 3700®, the LF was included in the MEs. MEDIT i-500® showed interpolation between the MEs and LF, with no clear direction for the deviation. CONCLUSIONS: Statistically different levels of congruence were found between the SB MEs and the corresponding LF when using different IOSs. Significant differences were also found between different SBs when scanned with the same IOS. Finally, the qualitative evaluation revealed different directions and patterns for the five IOSs.

2.
Artículo en Inglés | MEDLINE | ID: mdl-31936096

RESUMEN

Purpose: To present an experimental strategy for successfully capturing the margins of prepared single teeth with an intraoral scanner (IOS). Methods: The protocol was as follows: (1) an intraoral impression was captured with an IOS, without taking care of the visibility of the margins; (2) a partial analog impression was taken by means of a 3D-printed custom tray filled with polyvinylsiloxane light, after the removal of a retraction cord; (3) the hollow portion of the analog impression, with the preparation margins clearly visible, was scanned extraorally with the same IOS; (4) the scan of the analog impression was imported into computer-assisted-design (CAD) software, where its normals were inverted; (5) the scan with inverted normals was registered on the first intraoral scan, and replaced it; (6) the technician designed the final restoration, which was fabricated and delivered for application. The study outcomes were: (1) the marginal adaptation of the final crown; (2) the quality of interproximal contacts; and (3) the quality of occlusal contacts. Results: Thirty patients (18 males, 12 females; mean age 51.3 ± 11.6 years) were selected for this study. All these patients were restored with a monolithic translucent zirconia crown, fabricated following the aforementioned protocol. The clinical precision and the marginal adaptation of the crowns were optimal, interproximal contact points were perfect, and the only necessary adaptations were occlusal, with some minor precontacts that had to be polished. Conclusions: The present protocol seems to be compatible with the fabrication of clinically precise zirconia crowns. Further studies are needed to confirm these results.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Fotografía Dental/métodos , Impresión Tridimensional , Diente/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
3.
3D Print Med ; 6(1): 1, 2020 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-31915946

RESUMEN

PURPOSE: To present the application of custom-made 3D-printed subperiosteal implants for fixed prosthetic restoration of the atrophic posterior mandible of elderly patients. METHODS: Between January 2017 and June 2018, all partially edentulous patients aged over 65 years, with two or more missing teeth in the posterior atrophic mandible, and who did not want to undergo bone regenerative procedures, were included in this study. These patients were rehabilitated with custom-made subperiosteal implants, designed from cone beam computed tomography (CBCT) and fabricated in titanium by means of direct metal laser sintering (DMLS). The outcome measures were fit and stability of the implants at placement, duration of the intervention, implant survival, and early and late complications. All patients were followed for 1 year after surgery. RESULTS: Ten patients (four males, six females; mean age 69.6, SD ± 2.8, median 69, 95% CI 67.9-71.6) were included in the study. The fit of the implants was satisfactory, with a mean rating of 7 out of 10 (SD ± 1.6, median 7, 95% CI 6-8). Only two implants had insufficient fit, because of the presence of scattering in the CBCT; however, they were adapted to the sites during the interventions. The mean duration of the intervention was 44.3 min (SD ± 19.4, median 37, 95% CI 32.3-56.3). At the one-year follow-up, no implants were lost (survival rate 100%). One implant presented immediate postoperative complications with pain, discomfort and swelling, and two patients experienced late complications, having their provisional restorations fractured during the temporisation phase. All these complications were minor in nature, but the final complication rate amounted to 30% (three of ten patients). CONCLUSIONS: Although this study has limits (small patient sample and short follow-up), DMLS has proven to be an effective method for fabricating accurate subperiosteal implants, with high survival rates. This may represent an alternative treatment procedure in elderly patients with a severely atrophic posterior mandible, since it allows avoidance of regenerative bone therapies. Further studies are needed to confirm these outcomes.