Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Aging Clin Exp Res ; 36(1): 209, 2024 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-39446214

RESUMEN

The link between biological aging and prostate cancer (PCa) risk, particularly as indicated by elevated prostate-specific antigen (PSA) levels, remains uncertain. This study utilized data from the National Health and Nutrition Examination Survey (2001-2010) to explore this association. Biological age was assessed using Klemera-Doubal method age (KDMAge) and phenotypic age (PhenoAge). PCa was identified through self-reported diagnoses, and highly probable PCa was determined by PSA levels. We analyzed the prevalence of PCa and PSA-defined highly probable PCa across quartiles of biological age measures using weighted chi-square and linear trend tests. Associations were evaluated using weighted multiple logistic regression models. Among 7,209 and 6,682 males analyzed, the overall weighted prevalence of PCa was 2.86%, increasing to 9.60% in those aged 65 and above. A significant rise in PCa prevalence was observed with higher quartiles of KDMAge or PhenoAge (P for trend < 0.001), particularly in those under 65. In this younger group, higher PhenoAge acceleration quartiles were linked to increased PCa prevalence and higher risk of PCa (OR = 1.50, P = 0.015) as well as highly probable PCa in those without a diagnosis (OR = 1.28, P = 0.031). These findings suggest that accelerated biological aging is associated with an increased risk of PCa and may indicate early risk as signaled by PSA levels, even in those without a PCa diagnosis.


Asunto(s)
Envejecimiento , Encuestas Nutricionales , Antígeno Prostático Específico , Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/epidemiología , Neoplasias de la Próstata/sangre , Anciano , Persona de Mediana Edad , Antígeno Prostático Específico/sangre , Estados Unidos/epidemiología , Prevalencia , Factores de Riesgo , Adulto , Anciano de 80 o más Años
2.
Mater Today Bio ; 28: 101234, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39309165

RESUMEN

Magnesium (Mg)-based scaffolds are garnering increasing attention as bone repair materials owing to their biodegradability and mechanical resemblance to natural bone. Their effectiveness can be augmented by incorporating surface coatings to meet clinical needs. However, the limited bonding strength and unclear mechanisms of these coatings have impeded the clinical utility of scaffolds. To address these issues, this study introduces a composite coating of high-bonding-strength polydopamine-microarc oxidation (PDA-MHA) on Mg-based scaffolds. The results showed that the PDA-MHA coating achieved a bonding strength of 40.56 ± 1.426 MPa with the Mg scaffold surface, effectively enhancing hydrophilicity and controlling degradation rates. Furthermore, the scaffold facilitated bone regeneration by influencing osteogenic markers such as RUNX-2, OPN, OCN, and VEGF. Transcriptomic analyses further demonstrated that the PDA-MHA/Mg scaffold upregulated carboxypeptidase Z expression and activated the Wnt-4/ß-catenin signaling pathway, thereby promoting bone regeneration. Overall, this study demonstrated that PDA can synergistically enhance bone repair with Mg scaffold, broadening the application scenarios of Mg and PDA in the field of biomaterials. Moreover, this study provides a theoretical underpinning for the application and clinical translation of Mg-based scaffolds in bone tissue engineering endeavors.

3.
BMC Urol ; 24(1): 100, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689213

RESUMEN

BACKGROUND: Bone metastasis (BM) carries a poor prognosis for patients with upper-tract urothelial carcinoma (UTUC). This study aims to identify survival predictors and develop a prognostic nomogram for overall survival (OS) in UTUC patients with BM. METHODS: The Surveillance, Epidemiology, and End Results database was used to select patients with UTUC between 2010 and 2019. The chi-square test was used to assess the baseline differences between the groups. Kaplan-Meier analysis was employed to assess OS. Univariate and multivariate analyses were conducted to identify prognostic factors for nomogram establishment. An independent cohort was used for external validation of the nomogram. The discrimination and calibration of the nomogram were evaluated using concordance index (C-index), area under receiver operating characteristic curve (AUC), calibration curve, and decision curve analysis (DCA). All statistical analyses were performed using SPSS 23.0 and R software 4.2.2. RESULTS: The mean OS for UTUC patients with BM was 10 months (95% CI: 8.17 to 11.84), with 6-month OS, 1-year OS, and 3-year OS rates of 41%, 21%, and 3%, respectively. Multi-organ metastases (HR = 2.21, 95% CI: 1.66 to 2.95, P < 0.001), surgery (HR = 0.72, 95% CI: 0.56 to 0.91, P = 0.007), and chemotherapy (HR = 0.37, 95% CI: 0.3 to 0.46, P < 0.001) were identified as independent prognostic factors. The C-index was 0.725 for the training cohort and 0.854 for the validation cohort, and all AUC values were > 0.679. The calibration curve and DCA curve showed the accuracy and practicality of the nomogram. CONCLUSIONS: The OS of UTUC patients with BM was poor. Multi-organ metastases was a risk factor for OS, while surgery and chemotherapy were protective factors. Our nomogram was developed and validated to assist clinicians in evaluating the OS of UTUC patients with BM.


Asunto(s)
Neoplasias Óseas , Carcinoma de Células Transicionales , Nomogramas , Neoplasias Ureterales , Humanos , Neoplasias Óseas/secundario , Neoplasias Óseas/mortalidad , Masculino , Femenino , Anciano , Persona de Mediana Edad , Carcinoma de Células Transicionales/secundario , Carcinoma de Células Transicionales/mortalidad , Neoplasias Ureterales/mortalidad , Neoplasias Ureterales/patología , Neoplasias Ureterales/secundario , Tasa de Supervivencia , Neoplasias Renales/patología , Neoplasias Renales/mortalidad , Pronóstico , Estudios Retrospectivos , Programa de VERF , Anciano de 80 o más Años
4.
World J Urol ; 42(1): 122, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38453696

RESUMEN

PURPOSE: To maintain safe intrarenal pelvic pressure (IPP), the combination of flexible ureteroscope (fURS) and traditional ureteral access sheath (T-UAS) should maintain a basic rule that is the ratio of endoscope-sheath diameter (RESD) ≤ 0.75. However, the negative-pressure ureteral access sheath (NP-UAS) may break the rule of negative pressure suction. This study aimed to examine the effect of NP-UAS on IPP and flow rate (FR) with varying RESD. METHODS: In a 3D-printed renal model, flexible ureteroscopy lithotripsy (fURL) was replicated. Six sizes of fURS paired with 12Fr T-UAS and NP-UAS resulted in six distinct RESDs of 0.63, 0.78, 0.87, 0.89, 0.90, and 0.91. While the irrigation pressure (IRP) was set between 100 and 800 cmH2O and the sucking pressure (SP) was set between 0 and 800 cmH2O, the IPP and FR were measured in each RESD. RESULTS: NP-UASs can reduce the IPP and increase the FR at the same RESD compared to T-UASs. The IPP decreased with increasing SP with NP-UAS. When RESD ≤ 0.78, T-UAS and NP-UAS can maintain IPP < 40 cmH2O in most circumstances. When RESD = 0.87, it is challenging for T-UAS to sustain IPP < 40 cmH2O; however, NP-UAS can do so. When RESD ≥ 0.89, it is difficult to maintain an IPP < 40 cmH2O even with NP-UAS. CONCLUSION: NP-UAS can decrease IPP and increase FR compared with T-UAS. To maintain a safe IPP, it is recommended that RESD < 0.85 when utilizing NP-UAS.


Asunto(s)
Cálculos Renales , Uréter , Humanos , Ureteroscopía/métodos , Riñón , Ureteroscopios
5.
World J Urol ; 42(1): 130, 2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38460016

RESUMEN

OBJECTIVE: To explore the parameters influencing intraoperative calculi excretion (ICE) during flexible ureteroscopy lithotripsy (fURL) using in vitro simulation experiments. METHODS: 3D-printed human kidney models were used to simulate the elimination of gravel during fURL. The factors influencing the ICE during fURL were analyzed by comparing the effects of different degrees of hydronephrosis (mild, moderate, and severe), surgical positions (supine and lateral position), ratios of endoscope-sheath diameter (RESD) (0.625, 0.725, and 0.825), gravel sizes (0.50-1.00 mm, 0.25-0.50 mm, and 0.10-0.25 mm), and ureteral access sheaths (UASs) (traditional UAS and negative-pressure UAS) on ICE. RESULTS: The impacts of various UAS, RESD, degree of hydronephrosis, surgical positions, and gravel sizes on ICE were all significant (p < 0.05). We found no evidence of multicollinearity for all the independent variables, and the linear regression equation fitted as ICE ( g / min ) = 0.102 + 0.083 ∗ UAS grade - 0.050 ∗ RESD grade - 0.048 ∗ hydronephrosis grade + 0.065 ∗ position grade - 0.027 ∗ gravel size grade (R2 = 0.569). CONCLUSION: Employing negative-pressure UAS, smaller RESD, milder hydronephrosis, lateral position, and smaller gravel size contribute to improved ICE during fURL. Among them, the adoption of negative-pressure UAS had the most substantial effects.


Asunto(s)
Hidronefrosis , Cálculos Renales , Litotricia , Cálculos Ureterales , Humanos , Ureteroscopía , Cálculos Renales/cirugía , Ureteroscopios , Cálculos Ureterales/cirugía
6.
Int J Biol Macromol ; 263(Pt 2): 130407, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38417747

RESUMEN

This study focuses on enhancing interventional medical devices, specifically catheters, using a novel composite material. Challenges like corrosion and contamination in vivo, often caused by body fluids' pH, bacteria, and proteins, lead to mechanical damage, bacterial colonization, and biofilm formation on devices like catheters. The objective of this study was to prepare a versatile composite (HFs) by designing polyurethanes (HPU) with an ionic chain extender (HIID) and blending them with amphiphilic nanofibrillated cellulose (Am-CNF). The composite leverages dynamic interactions such as hydrogen bonding and electrostatic forces, as evidenced by Molecular Mechanics (MM) calculations. The H4F0.75 composite exhibited exceptional properties: 99 % length recovery post 600 stretching cycles at 100 % strain, rapid self-healing in artificial urine, high bactericidal activity, and excellent cell viability. Moreover, mechanical aging tests and UV-vis spectral analysis confirmed the material's durability and safety. These findings suggest that the HFs composite holds significant promise for improving catheters' performance in medical applications.


Asunto(s)
Incrustaciones Biológicas , Celulosa , Celulosa/farmacología , Celulosa/química , Poliuretanos/farmacología , Poliuretanos/química , Incrustaciones Biológicas/prevención & control , Catéteres , Antibacterianos/farmacología , Antibacterianos/química
7.
Carbohydr Polym ; 327: 121666, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38171658

RESUMEN

Self-healing coatings have shown promise in controlling the degradation of scaffolds and addressing coating detachment issues. However, developing a self-healing coating for magnesium (Mg) possessing multiple biological functions in infectious environments remains a significant challenge. In this study, a self-healing coating was developed for magnesium scaffolds using oxidized dextran (OD), 3-aminopropyltriethoxysilane (APTES), and nano-hydroxyapatite (nHA) doped micro-arc oxidation (MHA), named OD-MHA/Mg. The results demonstrated that the OD-MHA coating effectively addresses coating detachment issues and controls the degradation of Mg in an infectious environment through self-healing mechanisms. Furthermore, the OD-MHA/Mg scaffold exhibits antibacterial, antioxidant, and anti-apoptotic properties, it also promotes bone repair by upregulating the expression of osteogenesis genes and proteins. The findings of this study indicate that the OD-MHA coated Mg scaffold possessing multiple biological functions presents a promising approach for addressing infectious bone defects. Additionally, the study showcases the potential of polysaccharides with multiple biological functions in facilitating tissue healing even in challenging environments.


Asunto(s)
Dextranos , Magnesio , Magnesio/farmacología , Dextranos/farmacología , Materiales Biocompatibles Revestidos/farmacología , Regeneración Ósea , Osteogénesis , Durapatita/farmacología , Apoptosis , Andamios del Tejido
8.
Adv Sci (Weinh) ; 11(10): e2307746, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38145346

RESUMEN

Electrical stimulation (ES) is proposed as a therapeutic solution for managing chronic wounds. However, its widespread clinical adoption is limited by the requirement of additional extracorporeal devices to power ES-based wound dressings. In this study, a novel sandwich-structured photovoltaic microcurrent hydrogel dressing (PMH dressing) is designed for treating diabetic wounds. This innovative dressing comprises flexible organic photovoltaic (OPV) cells, a flexible micro-electro-mechanical systems (MEMS) electrode, and a multifunctional hydrogel serving as an electrode-tissue interface. The PMH dressing is engineered to administer ES, mimicking the physiological injury current occurring naturally in wounds when exposed to light; thus, facilitating wound healing. In vitro experiments are performed to validate the PMH dressing's exceptional biocompatibility and robust antibacterial properties. In vivo experiments and proteomic analysis reveal that the proposed PMH dressing significantly accelerates the healing of infected diabetic wounds by enhancing extracellular matrix regeneration, eliminating bacteria, regulating inflammatory responses, and modulating vascular functions. Therefore, the PMH dressing is a potent, versatile, and effective solution for diabetic wound care, paving the way for advancements in wireless ES wound dressings.


Asunto(s)
Diabetes Mellitus , Hidrogeles , Humanos , Biomimética , Proteómica , Cicatrización de Heridas , Vendajes
9.
Materials (Basel) ; 16(9)2023 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-37176215

RESUMEN

This study examines how aging affects the healing capacity of bituminous composites containing polyphosphoric acid (PPA). PPA is commonly used in bituminous composites to enhance its elasticity, however, PPA effectiveness highly depends on other constituents on the matrix and the environmental (internal and external) factors. In terms of internal factors, the interplay between PPA and various bitumen modifiers have been extensively studied. Here, we study how external factors such as exposure to ultraviolet radiation affect PPA's efficacy, measured in terms of change in bitumen's healing index. The study results showed that the introduction of PPA to bituminous composites significantly increases the bitumen healing index, however, the change in the healing index becomes less pronounced as aging progresses. The presence of additives such as taconite were found to affect the effect of PPA on bitumen's healing index. For instance, bitumens containing 30% taconite showed the highest increase in their healing index in the presence of PPA among studied scenarios. Overall, bitumen containing PPA had a higher healing index than those without PPA regardless of the extent of aging and dosage of modifiers. This, in turn, indicates that PPA is highly effective for enhancing bitumen healing. This can be attributed to the role of PPA in promoting intermolecular interactions within the bitumen matrix.

10.
Urolithiasis ; 51(1): 52, 2023 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-36929459

RESUMEN

To propose the suitable diameter of calculus debris produced during flexible ureteroscopy lithotripsy (fURL). A glass tube was used to simulate the stone excretion process during Furl. Different stone diameters (0.50-1.00 mm, 0.25-0.50 mm, and 0.10-0.25 mm) with three sizes of flexible ureteroscopy (fURS) (7.5Fr, 8.7Fr, and 9.9Fr) and ureteral access sheath (UAS) (12/14Fr) with or without negative pressure suction were employed in the experiment. The intraoperative calculi excretion (ICE) was recorded according to the stones discharged from the gap between fURS and UAS. The ICE raised significantly in thinner fURS and UAS due to the smaller Ratio of Endoscope-Sheath Diameter (RESD). The gravel size ≤ 0.25 mm was conducive to drainage with traditional UAS, while using fURS with negative-pressure UAS could significantly improve ICE. The gravel size ≤ 0.5 mm was conducive to expulsion. We clarify that ICE during ureteroscopy relates to RESD and negative pressure suction. The proper size of the stone fragment is critical in ensuring the expulsion during fURL, ≤ 0.25 mm in traditional UAS and ≤ 0.50 mm in negative-pressure UAS, respectively.


Asunto(s)
Cálculos Renales , Litotricia , Uréter , Cálculos Ureterales , Humanos , Ureteroscopía , Ureteroscopios , Litotricia/efectos adversos , Cálculos Ureterales/cirugía , Cálculos Renales/cirugía
11.
Front Bioeng Biotechnol ; 10: 1092543, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36686259

RESUMEN

Introduction: The repair of a diseased ureter is an urgent clinical issue that needs to be solved. A tissue-engineered scaffold for ureteral replacement is currently insufficient due to its incompetent bioactivity, especially in long-segment abnormalities. The primary reason is the failure of urothelialization on scaffolds. Methods: In this work, we investigated the ability of gelatin-grafted tubular scaffold in ureteral repairment and its related biological mechanism. We designed various porous asymmetric poly (L-lactic acid) (PLLA)/poly (L-lactide-co-e-caprolactone) (PLCL) tubes with a thermally induced phase separation (TIPS) method via a change in the ratio of solvents (named PP). To regulate the phenotype of urothelial cells and ureteral reconstruction, gelatin was grafted onto the tubular scaffold using ammonolysis and glutaraldehyde crosslinking (named PP-gel). The in vitro and in vivo experiments were performed to test the biological function and the mechanism of the scaffolds. Results and Discussion: The hydrophilicity of the scaffold significantly increased after gelatin grafting, which promoted the adhesion and proliferation of urothelial cells. Through subcutaneous implantation in rats, PP-gel scaffolds demonstrated good biocompatibility. The in vivo replacement showed that PP-gel could improve urothelium regeneration and maintain renal function after the ureter was replaced with an ∼4 cm-long PP-gel tube using New Zealand rabbits as the experimental animals. The related biologic mechanism of ureteral reconstruction was detected in detail. The gelatin-grafted scaffold upgraded the integrin α6/ß4 on the urothelial cell membrane, which phosphorylates the focal adhesion kinase (FAK) and enhances urothelialization via the MAPK/Erk signaling pathway. Conclusion: All these results confirmed that the PP46-gel scaffold is a promising candidate for the constitution of an engineered ureter and to repair long-segment ureteral defects.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA