Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
J Hazard Mater ; 477: 135282, 2024 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-39088952

RESUMEN

Although biocides are important materials in modern society and help protect human health and the environment, increasing exposure to combined biocides can cause severe side effects in the human body, such as lung fibrosis. In this study, we developed a receptonics system to screen for biocides in combined household chemical products based on biocides. The system contains transient receptor potential ankyrin 1 (TRPA1) nanovesicles (NVs) to sense biocides based on pain receptors and a side-gated field-effect transistor (SGFET) using a single-layer graphene (SLG) micropattern channel. The binding affinities between the TRPA1 receptor and the various biocides were estimated by performing biosimulation and using a calcium ion (Ca2+) assay, and the sensitivity of the system was compared with that of TRPA1 NV receptonics systems. Based on the results of the TRPA1 NV receptonics system, the antagonistic and potentiation effects of combined biocides and household chemical products depended on the concentration. Finally, the TRPA1 NV receptonics system was applied to screen for biocides in real products, and its performance was successful. Based on these results, the TRPA1 NV receptonics system can be utilized to perform risk evaluations and identify biocides in a simple and rapid manner.

2.
Life (Basel) ; 14(7)2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39063641

RESUMEN

The human clavicle's unique S-shaped, three-dimensional structure complicates fracture management. This study evaluated the anatomical conformity of pre-contoured anatomical plates using 3D-printed clavicle models. CT scans from 30 patients (15 males and 15 females) were used to create these models. Three brands of distal clavicle plate systems (Acumed, Synthes, and Arthrex) were tested for fit. Measurements included the distance from the distal end of the clavicle to the plate's lateral end, the gap between the clavicle and the plate, and the overhang distance. Results showed significant differences in clavicle length between sexes, with men having a mean length of 156.1 ± 7.6 mm and women 138.4 ± 4.3 mm, both with normal distribution (p > 0.05). The mean lateral distance was 7.9 ± 1.7 mm, and the mean medial gap was 3.6 ± 3.0 mm, showing no significant differences between products or sexes. The mean overhang distance was 5.8 ± 4.6 mm, with larger values in women for the Acumed (p = 0.037) and Arthrex (p = 0.000) plates. Overall, pre-contoured plates exhibited notable discrepancies, especially in shorter clavicles.

3.
Injury ; 55(10): 111657, 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-39002321

RESUMEN

PURPOSE: Although hook plate fixation is popularly used, concerns exist regarding periprosthetic fractures and the necessity to remove the plate to prevent subacromial erosion and subsequent acromion fracture, due to its non-anatomical design. We hypothesized that a low profile 2.7 mm distal locking hook plate would provide comparable stability to a properly used 3.5 mm distal locking hook plate MATERIALS AND METHODS: A 3.5 mm distal locking plate (type 1) and a low profile 2.7 mm plate (type 2) were assessed by finite element analysis. Peak von Mises stress (PVMS) was calculated on the acromion's undersurface, clavicle shaft, and hook, focusing on how these stresses varied with the number and placement of distal locking screws. RESULTS: Increased distal screws in both types led to lower PVMS on the acromion's undersurface and the hook, with the lowest acromion PVMS observed in type 2 with three distal screws, and on the hook in type 1 with two distal screws. Increasing the number of distal screws similarly reduced PVMS on the clavicle shaft, with the lowest in type 1 with two distal screws. In both plate types, the most posterior distal locking screw played a crucial role in distributing stress across the acromion and the hook. CONCLUSION: The low profile 2.7 mm distal locking hook plate showed comparable biomechanical results to the 3.5 mm distal locking hook plate. Increasing the number of distal locking screws showed less stress concentration on the bone and hook in both models. The most posterior distal locking screw showed an essential role in stress distribution.

4.
Lab Chip ; 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39072370

RESUMEN

Ion channels, which are key to physiological regulation and drug discovery, control ion flux across membranes, and their dysregulation leads to various diseases. Ca2+ monitoring is crucial for cellular signaling when performing Ca-based assays in ion channel research; these assays are widely utilized in both academic and pharmaceutical contexts for drug screening and pharmacological profiling. However, existing detection methods are limited by slow detection speeds, low throughput, complex processes, and low analyte viability. In this study, we developed a label-free optical biosensing method using a conical Au/polydimethylsiloxane platform tailored to detect Ca2+ influx in A549-originated nanovesicles facilitated by the transient receptor potential ankyrin 1 (TRPA1) channel. Nanovesicles expressing cellular signaling components mimic TRPA1 signal transduction in cell membranes and improve analyte viability. The conical Au/polydimethylsiloxane sensor converted Ca2+ influx events induced by specific agonist exposure into noticeable changes in relative transmittance under visible light. The optical transmittance change accompanying Ca2+ influx resulted in an enhanced sensing response, high accuracy and reliability, and rapid detection (∼5 s) without immobilization or ligand treatments. In the underlying sensing mechanism, morphological variations in nanovesicles, which depend on Ca2+ influx, induce a considerable light scattering change at an interface between the nanovesicle and Au, revealed by optical simulation. This study provides a foundation for developing biosensors based on light-matter interactions. These sensors are simple and cost-effective with superior performance and diverse functionality.

5.
Clin Shoulder Elb ; 27(2): 203-211, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38863404

RESUMEN

BACKGROUND: Little is known about alterations of the rotator cuff (RC) macroscopic vasculature associated with medical conditions and/or habits that predispose a person to diseases of the peripheral microcirculation. The high frequency of cuff tear and re-tear in patients with diabetes, hypercholesterolemia, uncontrolled arterial hypertension, or metabolic syndrome may be due to tissue hypovascularity. METHODS: The macroscopic vasculature of both the articular and bursal sides of the posterosuperior RC was evaluated arthroscopically in 107 patients (mean age, 58.2 years) with no RC tear. Patients were divided into three groups according to medical comorbidities and lifestyle factors (group I, none; group II, smokers and/or drinkers and one comorbidity; and group III, two or more comorbidities). Pulsating vessels originating from both the myotendinous and osteotendinous junctions were assessed as "clearly evident," "poorly evident," or "not evident." RESULTS: Groups I, II, and III comprised 36, 45, and 26 patients, respectively. Within the myotendinous junction, vessels were visualized in 22 group I patients (61%), 25 group II patients (55%), and 6 group III patients (23%) (P=0.007). Pulsating arterial vessels originating from the osteotendinous junction were seen in 42%, 36%, and 0% of patients, respectively (P<0.001). Within the bursal side of the RC, a dense anastomotic network was visualized (either clearly or poorly) in 94% (34), 80% (36), and 35% (9) of patients, respectively (P<0.001). CONCLUSIONS: The macroscopic vasculature of the RC is influenced by pre-existing diseases and lifestyle factors, which may impair peripheral microcirculation. Level of evidence: III.

6.
Am J Sports Med ; 52(6): 1439-1448, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38551128

RESUMEN

BACKGROUND: Even though arthroscopic rotator cuff repair is recognized as a standard treatment option, the risk of postoperative retear is a major concern. PURPOSE: To evaluate the effect of porcine-derived absorbable patch-type atelocollagen during arthroscopic rotator cuff repair. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A total of 64 patients with rotator cuff tears diagnosed on magnetic resonance imaging (MRI) were enrolled prospectively from November 2020 to December 2021. Both groups had repairs using the suture bridge technique. For the atelocollagen group, before securing the lateral anchors, we inserted porcine-derived absorbable patch-type atelocollagen between the footprint and the tendon. On postoperative day 2, the patients underwent MRI to confirm containment of the patch-type atelocollagen. At 6 months and 1 year postoperatively, the signal intensity of the repaired tendon was assessed using MRI. Patients were evaluated using the Constant score as the primary outcome, along with the visual analog scale for pain; range of motion; American Shoulder and Elbow Surgeons score; University of California, Los Angeles, score; and Korean Shoulder Score preoperatively and at 2, 3, 6, and 12 months postoperatively. RESULTS: No significant changes in the Constant score as primary outcome, pain or other functional scores, and range of motion were observed between the groups at 1 year postoperatively. The patch-type atelocollagen was confirmed to be contained by the time-zero MRI scan taken 2 days postoperatively. Among the 55 patients included in final analysis, 12 retear cases were recorded (21.8% retear rate). A significantly lower retear rate was found in the atelocollagen group, as 3 cases were observed in this group (10.3%) and 9 cases were observed in the conventional repair group (34.6%) (P = .048). CONCLUSION: The Constant score was not different between the groups. The retear rate after rotator cuff repair was significantly lower in the group that received porcine-derived absorbable patch-type atelocollagen compared with in the conventional group. REGISTRATION: KCT0005184 (Clinical Research Information Service [CRIS]; https://cris.nih.go.kr).


Asunto(s)
Implantes Absorbibles , Artroscopía , Colágeno , Lesiones del Manguito de los Rotadores , Humanos , Artroscopía/métodos , Masculino , Persona de Mediana Edad , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Femenino , Estudios Prospectivos , Colágeno/uso terapéutico , Animales , Anciano , Imagen por Resonancia Magnética , Rango del Movimiento Articular , Porcinos , Recurrencia
7.
Adv Mater ; 36(9): e2303079, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37487578

RESUMEN

The transmission and pathogenesis of highly contagious fatal respiratory viruses are increasing, and the need for an on-site diagnostic platform has arisen as an issue worldwide. Furthermore, as the spread of respiratory viruses continues, different variants have become the dominant circulating strains. To prevent virus transmission, the development of highly sensitive and accurate on-site diagnostic assays is urgently needed. Herein, a facile diagnostic device is presented for multi-detection based on the results of detailed receptor-ligand dynamics simulations for the screening of various viral strains. The novel bioreceptor-treated electronics (receptonics) device consists of a multichannel graphene transistor and cell-entry receptors conjugated to N-heterocyclic carbene (NHC). An ultrasensitive multi-detection performance is achieved without the need for sample pretreatment, which will enable rapid diagnosis and prevent the spread of pathogens. This platform can be applied for the diagnosis of variants of concern in clinical respiratory virus samples and primate models. This multi-screening platform can be used to enhance surveillance and discriminate emerging virus variants before they become a severe threat to public health.


Asunto(s)
Bioensayo , Grafito , Animales , Ligandos , Electrónica
8.
Clin Shoulder Elb ; 26(4): 397-405, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38052505

RESUMEN

BACKGROUND: A precontoured plate rarely fits properly within the patient's clavicle and must be bent intraoperatively. This study aimed to determine whether anatomical reduction could be achieved using a plate bent before surgery. METHODS: This study included 87 consecutive patients with displaced mid-shaft clavicle fractures who underwent plate fixation and were followed-up for a minimum of 1 year. After exclusions, 39 consecutive patients underwent fixation with a precontoured plate bent intraoperatively (intraoperative bending group), and 28 underwent fixation with the plate bent preoperatively (preoperative bending group). Using free software and a three-dimensional (3D) printer, ipsilateral clavicle 3D-printed models were constructed. Using plain radiographs, the distance between the edge of the lateral inferior cortex and the medial inferior cortex was measured. The angle between the line connecting the inferior cortex edge and the line passing through the flat portion of the superior cortex of the distal clavicle was measured. RESULTS: Mean length differences between the ipsilateral and contralateral clavicle were smaller on both anteroposterior (AP; P=0.032) and axial images (P=0.029) in the preoperative bending group. The mean angular differences on both AP (P=0.045) and axial images (P=0.008) were smaller in the preoperative bending group. No significant differences were observed between the two groups in functional scores at the last follow-up. CONCLUSIONS: Smaller differences in length and angle between the ipsilateral and contralateral clavicle, indicative of reduction, were observed in the preoperative bending group. Using the precontoured technique with low expense, the operation was performed more effectively as reflected by a shorter operation time. Level of evidence: III.

9.
Clin Shoulder Elb ; 26(3): 323-329, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37607856

RESUMEN

Rotator cuff tear is a common shoulder injury that compromises both function and quality of life. Despite the prevalence of the injury and advancements in repair techniques, a significant percentage of these repairs fail. This review aims to explore the multifactorial reasons behind this failure, including the degenerative nature of the rotator cuff tendon, inherent and extrinsic factors, and the role of hypoxia in tissue degeneration. Additionally, it elucidates potential strategies for improving healing outcomes.

10.
Adv Mater ; 35(35): e2302996, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37377148

RESUMEN

An in vitro model, composed of the short-wavelength human opsins and rhodopsins, is created. Two types of photosensitive neural spheroids are transfected for selective reaction under bluish-purple and green lights. These are employed to two devices with intact neuron and neural-spheroid to study the interaction. By photostimulation, the photosensitive spheroid initiated photoactivation, and the signal generated from its body is transmitted to adjacent neural networks. Specifically, the signal traveled through the axon bundle in narrow gap from photosensitive spheroid to intact spheroid as an eye-to-brain model including optic nerve. The whole process with photosensitive spheroid is monitored by calcium ion detecting fluorescence images. The results of this study can be applied to examine vision restoration and novel photosensitive biological systems with spectral sensitivity.


Asunto(s)
Opsinas , Visión Ocular , Humanos , Opsinas/metabolismo , Neuronas/metabolismo , Esferoides Celulares/metabolismo
11.
ACS Sens ; 8(6): 2169-2178, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37161992

RESUMEN

Nanoplasmonic sensors are a widely known concept and have been studied with various applications. Among them, gas detection is engaging attention in many fields. However, the analysis performance of nanoplasmonic sensors based on refractive index confined to the metal nanostructure characteristics causes challenges in gas detection. In this study, we develop a graphene-encased gold nanorod (AuNR)-based nanoplasmonic sensor to detect cadaverine gas. The graphene-encased AuNR (Gr@AuNR) presents an ultrasensitive peak wavelength shift even with tiny molecules. In addition, the external potential transmitted through graphene induces an additional shift. A chemical receptor is immobilized on Gr@AuNR (CR@Gr@AuNR) for selectively capturing cadaverine. The CR@Gr@AuNR achieves ultrasensitive detection of cadaverine gas, and the detection limit is increased to 15.99 ppb by applying a voltage to graphene. Furthermore, the experimental results of measuring cadaverine generated from spoiled pork show the practicality of CR@Gr@AuNR. The strategy of external-boosted nanoplasmonics provides new insight into plasmonic sensing and applications.


Asunto(s)
Grafito , Nanotubos , Grafito/química , Oro/química , Cadaverina , Nanotubos/química
12.
Sensors (Basel) ; 23(3)2023 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-36772463

RESUMEN

In a connected car, the vehicle's internal network is connected to the outside through communication technology. However, this can cause new security vulnerabilities. In particular, V2X communication, to provide the safety of connected cars, can directly threaten the lives of passengers if a security attack occurs. For V2X communication security, standards such as IEEE 1609.2 define the technical functions that digital signature and encryption to provide security of V2X messages. However, it is difficult to verify the security technology by applying it to the environment with real roads because it can be made up of other safety accidents. In addition, vehicle simulation R&D is steadily being carried out, but there is no simulation that evaluates security for the V2X application level. Therefore, in this paper, a virtual machine was used to implement a V2X communication simulation environment that satisfies the requirements for the security evaluation of connected cars. Then, we proposed scenarios for cybersecurity testing and evaluation, implemented and verified through CANoe Option.Car2X. Through this, it is possible to perform sufficient preliminary verification to minimize the variables before verifying security technology in a real road environment.

13.
J Orthop Trauma ; 37(2): e57-e62, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36084238

RESUMEN

OBJECTIVES: To determine the demographic characteristics and clinical and radiologic results of low transcondylar fractures and compare them with those of other types of distal humerus fractures using multicenter data and to suggest an optimal method for their treatment. DESIGN: Retrospective cohort study. SETTING: Tertiary-care university hospital. PATIENTS: Between 2009 and 2019, 581 patients who underwent surgery for distal humerus fractures (OTA/AO classification A1 to C3) were enrolled at 7 university-affiliated hospitals. INTERVENTION: Internal fixation of low transcondylar fractures. MAIN OUTCOME MEASURES: Demographic characteristics, including sex, age, mechanism of injury, fixation methods, and complications, were compared between low transcondylar (group A) and other distal humerus (group B) fractures. Clinical outcomes assessed included pain, stability, and range of motion. Radiographs obtained at the latest follow-up were assessed for union, delayed union, nonunion, and implant failure. RESULTS: Mean age was 62.1 ± 19.1 (range, 20-95) years, and it was higher in group A (n = 100) than in group B (n = 376). Patients in group A were predominantly women. Low-energy trauma, such as that from a simple fall, was the most common cause of fracture in group A. Both column fixation, including parallel and orthogonal double plating, was performed more commonly in group A than in group B (87.4% vs. 66.4%, P < 0.001). The nonunion rate was higher in group A, but the difference was not significant. The incidence of ulnar nerve-related symptoms was higher in group A after surgery (6.3% vs. 2.0%, P = 0.003). No significant difference in clinical outcomes was found between the groups. CONCLUSIONS: Low transcondylar fractures occurred more frequently than other distal humerus fractures in older female patients and accounted for 21% of distal humerus fractures. The incidence of ulnar nerve-related symptoms was higher in patients with low transcondylar fractures after surgery. Clinical outcomes were not inferior in patients with low transcondylar fractures. The nonunion rate in patients with low transcondylar fractures treated with double plating was 3.6%. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fijación Interna de Fracturas , Fracturas Humerales Distales , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Placas Óseas , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fracturas Humerales Distales/cirugía , Rango del Movimiento Articular , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
14.
Biosens Bioelectron ; 215: 114551, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35839622

RESUMEN

Monitoring food freshness/spoilage is important to ensure food quality and safety. Current methods of food quality monitoring are mostly time-consuming and labor intensive processes that require massive analytical equipment. In this study, we developed a portable bioelectronic nose (BE-nose) integrated with trace amine-associated receptor (TAAR) nanodiscs (NDs), allowing food quality monitoring via the detection of food spoilage indicators, including the biogenic amines cadaverine (CV) and putrescine (PT). The olfactory receptors TAAR13c and TAAR13d, which have specific affinities for CV and PT, were produced and successfully reconstituted in ND structures. TAAR13 NDs BE-nose-based side-gated field-effect transistor (SG-FET) system was constructed by utilizing a graphene micropattern (GM) into which two types of olfactory NDs (TAAR13c ND and TAAR13d ND) were introduced, and this system showed ultrahigh sensitivity for a limit of detection (LOD) of 1 fM for CV and PT. Moreover, the binding affinities between the TAAR13 NDs and the indicators were confirmed by a tryptophan fluorescence quenching assay and biosimulations, in which the specific binding site was confirmed. Gas-phase indicators were detected by the TAAR13 NDs BE-nose platform, and the LODs for CV and PT were confirmed to be 26.48 and 7.29 ppb, respectively. In addition, TAAR13 NDs BE-nose was fabricated with commercial gas sensors as a portable platform for the measurement of NH3 and H2S, multiplexed monitoring was achieved with similar performance, and the change ratio of the indicators was observed in a real sample. The integration of commercial gas sensors on a BE-nose enhanced the accuracy and reliability for the quality monitoring of real food samples. These results indicate that the portable TAAR13 NDs BE-nose can be used to monitor CV and PT over a wide range of concentrations, therefore, the electronic nose platform can be utilized for monitoring the freshness/spoilage step in various foods.


Asunto(s)
Técnicas Biosensibles , Receptores Odorantes , Técnicas Biosensibles/métodos , Cadaverina , Nariz Electrónica , Putrescina , Receptores Odorantes/química , Reproducibilidad de los Resultados
15.
Nano Lett ; 22(16): 6825-6832, 2022 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-35801941

RESUMEN

A photoreceptor on the retina acts as an optical waveguide to transfer an individual photonic signal to the cell inside, which is determined by the refractive index of internal materials. Under the photoactivation of photoreceptors making conformational and chemical variation in a visual cell, the optical signal modulation is demonstrated using an artificial photoreceptor-based waveguide with a controlling beam refraction. Two types of nanodiscs are made of human photoreceptor proteins, short-wavelength-sensitive opsin and rhodopsin, with spectral sensitivity. The refractive index and nonlinear features of those two photosensitive nanodiscs are investigated as fundamental properties. The photonanodiscs are photoactivated in such a way that allow refractive index tuning over 0.18 according to the biological function of the respective proteins with color-dependent response.


Asunto(s)
Refractometría , Rodopsina , Humanos , Retina , Rodopsina/metabolismo
16.
Am J Sports Med ; 50(8): 2219-2226, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35604076

RESUMEN

BACKGROUND: Because the articular layer is more prone to retraction than the bursal layer of the supraspinatus tendon, it is important to restore each layer anatomically while repairing delaminated rotator cuff tears (RCTs). PURPOSE: To compare clinical outcomes and tendon integrity between knotless layer-by-layer and conventional en masse repair techniques for delaminated RCTs. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: We retrospectively reviewed data from 174 consecutive patients with delaminated RCTs treated by arthroscopic suture bridge repair. Only 115 patients with medium to large supraspinatus tears with delamination were included. The 33 patients treated using the knotless layer-by-layer technique (group 2) were matched 1:1 with patients treated using en masse repair with the suture bridge technique (group 1) based on propensity scores. Tendon thickness was measured on magnetic resonance imaging (MRI). Signal changes in the bursal, articular, and intratendinous layers were assessed using T2-weighted MRI. RESULTS: Postoperatively, statistically significant improvements were seen in both groups compared with preoperatively functional scores. At the final follow-up, there was a statistically significant difference in the Constant score, which was higher in group 2 than in group 1 (91.4 ± 6.0 and 84.3 ± 16.4, respectively; P = .005). There was 1 case of a retear in each group, representing a 3% retear rate. Group 2 had thicker tendons than group 1 (6.9 ± 1.1 and 6.0 ± 1.2 mm, respectively; P = .017). On T2-weighted MRI, a low signal intensity in the articular layer was more common in group 2 (P = .046). CONCLUSION: En masse repair using the suture bridge technique and the knotless layer-by-layer technique were both effective. Regarding tendon healing, no significant differences were seen in retear rates. However, superior results in terms of the Constant score, tendon thickness, and signal intensity in the articular layer were observed using the knotless layer-by-layer technique.


Asunto(s)
Lesiones del Manguito de los Rotadores , Artroscopía/métodos , Humanos , Imagen por Resonancia Magnética , Puntaje de Propensión , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/cirugía , Técnicas de Sutura , Suturas , Resultado del Tratamiento
17.
Biosens Bioelectron ; 207: 114195, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35325719

RESUMEN

Due to the increase in drug-facilitated sexual assault (DFSA) enabled by the illegal use of drugs, there have been constant demands for simple methods that can be used to protect oneself against crime in real life. γ-Hydroxybutyric acid (GHB), a central nervous system depressant, is one of the most dangerous drugs for use in DFSA because it is colorless and has slow physiological effects, which pose challenges for developing in situ, real-time GHB monitoring techniques. In this study, we developed a method for in situ colorimetric GHB detection using various self-protection products (SPPs) coated with 2-(3-bromo-4-hydroxystyryl)-3-ethylbenzothiazol-3-ium iodide (BHEI) as a chemical receptor embedded in hydrogels. Additionally, smartphone-based detection offers enhanced colorimetric sensitivity compared to that of the naked eye. The developed SPPs will help address drug-facilitated social problems.


Asunto(s)
Técnicas Biosensibles , Oxibato de Sodio , Colorimetría , Hidrogeles , Hidroxibutiratos
18.
Biosens Bioelectron ; 202: 113981, 2022 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-35086028

RESUMEN

The development of effective assay techniques for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has recently received research attention due to its rapid worldwide spread and considerable risk to human health. The receptor-binding domain (RBD) of the spike (S) protein in SARS-CoV-2, a key component for viral entry that has a unique sequence compared to other structural proteins, has been considered an important diagnostic target. In this respect, low-frequency vibrational modes have the advantage of providing information about compositional and structural dependencies at the peptide level. In this study, the sensitive and selective detection of peptides derived from the RBD in SARS-CoV-2 and SARS-CoV was investigated using metamaterial-based sensing chips with a terahertz time-domain spectroscopy (THz-TDS) system. Based on their RBD sequences, two pairs of peptides with 20 residues each were prepared. The sensitivity, specificity, and reproducibility of the proposed system were examined via quantitative analysis using THz metamaterials at three resonance frequencies, and it was found that the species could be discriminated based on their sequences. The THz signals were analyzed with regard to the major amino acid components of the peptides, and the molecular distributions were also investigated based on the hydropathy and net charge of the peptides.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Humanos , Péptidos/metabolismo , Unión Proteica , Reproducibilidad de los Resultados , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus/química
19.
Biosens Bioelectron ; 200: 113908, 2022 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-34972042

RESUMEN

Monitoring food spoilage is one of the most effective methods for preventing food poisoning caused by biogenic amines or microbes. Therefore, various analytical techniques have been introduced to detect low concentrations of cadaverine (CV) and putrescine (PT), which are representative biogenic polyamines involved in food spoilage (5-8 ppm at the stage of initial decomposition after storage for 5 days at 5 °C and 17-186 ppm at the stage of advanced decomposition after storage for 7 days at 5 °C). Although previous methods showed selective CV and PT detection even at low concentrations, the use of these methods remains challenging in research areas that require in-situ, real-time, on-site monitoring. In this study, we demonstrated for the first time an in-situ high-performance chemical receptor-conjugated graphene electronic nose (CRGE-nose) whose limits of detection (LODs), 27.04 and 7.29 ppb, for CV and PT are up to 102 times more sensitive than those of conventional biogenic amine sensors. Specifically, the novel chemical receptors 2,7-bis(3-morpholinopropyl)benzo[lmn][3,8] phenanthroline-1,3,6,8(2H,7H)-tetraone (NaPhdiMor (NPM)) and 2,7-bis(2-((3-morpholinopropyl)amino)ethyl)benzo[lmn][3,8]phenanthroline-1,3,6,8(2H,7H)-tetraone (NaPhdiEtAmMor (NPEAM)) were designed on the basis of density functional theory (DFT) calculations, and their interaction mechanism was characterized by a DFT 3D simulation. Interestingly, the CRGE-nose was connected on a micro sim chip substrate via wire bonding and then integrated into wireless portable devices, resulting in a cost-effective, high-performance prototype CRGE-nose device capable of on-site detection. The portable CRGE-nose can be used for in-situ monitoring of CV and PT concentration changes as low as 27.04 and 7.29 ppb in real meats such as pork, beef, lamb and chicken.


Asunto(s)
Técnicas Biosensibles , Grafito , Animales , Aminas Biogénicas , Cadaverina , Bovinos , Nariz Electrónica , Putrescina , Ovinos
20.
Arch Orthop Trauma Surg ; 142(2): 219-226, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33170353

RESUMEN

INTRODUCTION: We compared the angle of the humerus and plate and to assess compatibility of a plate to the proximal humerus using three-dimensional (3D) printed models. MATERIALS AND METHODS: A total of 120 cases were included, who underwent anteroposterior shoulder radiographs. From these, 30 cases with 3D shoulder computed tomography scans were randomly selected to print 3D model. The lateral angle between the lateral cortex of the humeral shaft and lateral border of the greater tuberosity (GT), neck-shaft angle, and height from the most proximal point of the GT to the angular point were measured. When the plates were applied on the 3D models, the gap from the most proximal point of the GT to the proximal rim of the plate was measured. RESULTS: The mean lateral angle in plain radiographs was 12.9 ± 2.2° and height from the most proximal point of the GT to the angular point was 44.4 ± 4.7 mm. The bending angles of the three plates were 8° and 10°. Height from the proximal rim of the plate to the bending point was 42.4, 42.0 and 43.8 mm. In 98% of cases, the lateral angle of the humerus was larger than all three plates. In 43% of cases, height of the GT was smaller than height of plates. When plates were applied to the 3D model, the mean gap from GT to plate was 4.8 ± 2.8 mm. CONCLUSIONS: There was large variation in the lateral angle of the proximal humerus, which was not correlated with the neck-shaft angle. The lateral angle of the humerus was larger than the plates and prone to varus reduction and medial collapse. LEVEL OF EVIDENCE OR CLINICAL RELEVANCE: Basic science study.


Asunto(s)
Fracturas del Hombro , Hombro , Placas Óseas , Fijación Interna de Fracturas , Humanos , Húmero/diagnóstico por imagen , Húmero/cirugía , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA