Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Eur J Heart Fail ; 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38847420

RESUMEN

AIM: The RESHAPE-HF2 trial is designed to assess the efficacy and safety of the MitraClip device system for the treatment of clinically important functional mitral regurgitation (FMR) in patients with heart failure (HF). This report describes the baseline characteristics of patients enrolled in the RESHAPE-HF2 trial compared to those enrolled in the COAPT and MITRA-FR trials. METHODS AND RESULTS: The RESHAPE-HF2 study is an investigator-initiated, prospective, randomized, multicentre trial including patients with symptomatic HF, a left ventricular ejection fraction (LVEF) between 20% and 50% with moderate-to-severe or severe FMR, for whom isolated mitral valve surgery was not recommended. Patients were randomized 1:1 to a strategy of delivering or withholding MitraClip. Of 506 patients randomized, the mean age of the patients was 70 ± 10 years, and 99 of them (20%) were women. The median EuroSCORE II was 5.3 (2.8-9.0) and median plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP) was 2745 (1407-5385) pg/ml. Most patients were prescribed beta-blockers (96%), diuretics (96%), angiotensin-converting enzyme inhibitors/angiotensin receptor blockers/angiotensin receptor-neprilysin inhibitors (82%) and mineralocorticoid receptor antagonists (82%). The use of sodium-glucose cotransporter 2 inhibitors was rare (7%). Cardiac resynchronization therapy (CRT) devices had been previously implanted in 29% of patients. Mean LVEF, left ventricular end-diastolic volume and effective regurgitant orifice area (EROA) were 31 ± 8%, 211 ± 76 ml and 0.25 ± 0.08 cm2, respectively, whereas 44% of patients had mitral regurgitation severity of grade 4+. Compared to patients enrolled in COAPT and MITRA-FR, those enrolled in RESHAPE-HF2 were less likely to have mitral regurgitation grade 4+ and, on average, HAD lower EROA, and plasma NT-proBNP and higher estimated glomerular filtration rate, but otherwise had similar age, comorbidities, CRT therapy and LVEF. CONCLUSION: Patients enrolled in RESHAPE-HF2 represent a third distinct population where MitraClip was tested in, that is one mainly comprising of patients with moderate-to-severe FMR instead of only severe FMR, as enrolled in the COAPT and MITRA-FR trials. The results of RESHAPE-HF2 will provide crucial insights regarding broader application of the transcatheter edge-to-edge repair procedure in clinical practice.

2.
JACC Cardiovasc Interv ; 17(12): 1440-1451, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38639690

RESUMEN

BACKGROUND: Thirty-day outcomes with the investigational Intrepid transapical (TA) transcatheter mitral valve replacement (TMVR) system have previously demonstrated good technical success, but longer-term outcomes in larger cohorts need to be evaluated. OBJECTIVES: The authors sought to evaluate the 2-year safety and performance of the Intrepid TA-TMVR system in patients with symptomatic, ≥moderate-severe mitral regurgitation (MR) and high surgical risk. METHODS: Patient eligibility was determined by local heart teams and approved by a central screening committee. Clinical events were adjudicated by an independent clinical events committee. Echocardiography was evaluated by an independent core laboratory. RESULTS: The cohort included 252 patients that were enrolled at 58 international sites before February 2021 as part of the global Pilot Study (n = 95) or APOLLO trial (primary cohort noneligible + TA roll-ins, n = 157). Mean age was 74.2 years, mean STS-PROM was 6.3%, 60.3% were male, and 80.6% were in NYHA functional class III/IV. Most presented with secondary MR (70.1%), and nearly all had ≥moderate-severe MR (98.4%). All-cause mortality was 13.1% (30-day), 27.3% (1-year), and 36.2% (2-year). The 30-day ≥major bleeding event rate was 22.3%. Heart failure rehospitalization was 9.6% (30-day) and 36.2% (2-year). At 2 years, >50% of patients were alive with improvement in NYHA functional class (82.1%, class I/II), and all patients with available echocardiograms had ≤mild MR. CONCLUSIONS: This analysis represents the largest reported TA-TMVR experience with the longest follow-up in high-risk ≥moderate-severe MR patients. Early mortality and heart failure rehospitalizations were significant, exacerbated by early TA-related bleeding events; however, meaningful improvements in clinical outcomes and marked reductions in MR severity were observed through 2 years.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Recuperación de la Función , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Femenino , Masculino , Anciano , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Factores de Tiempo , Anciano de 80 o más Años , Factores de Riesgo , Diseño de Prótesis , Valor Predictivo de las Pruebas , Complicaciones Posoperatorias/etiología , Persona de Mediana Edad , Hemodinámica , Readmisión del Paciente , Ecocardiografía
3.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599692

RESUMEN

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Estudios de Seguimiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos
4.
ESC Heart Fail ; 11(2): 1218-1227, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38303542

RESUMEN

AIMS: Acute mitral regurgitation (MR) in the setting of myocardial infarction (MI) may be the result of papillary muscle rupture (PMR). This condition is associated with high morbidity and mortality. We aim to evaluate the feasibility of transcatheter edge-to-edge mitral valve repair (TEER) in this acute setting. METHODS AND RESULTS: We analysed data from the International Registry of MitraClip in Acute Mitral Regurgitation following acute Myocardial Infarction (IREMMI) of 30 centres in Europe, North America, and the middle east. We included patients with post-MI PMR treated with TEER as a salvage procedure, and we evaluated immediate and 30-day outcomes. Twenty-three patients were included in this analysis (9 patients suffered complete papillary muscle rupture, 9 partial and 5 chordal rupture). The patients' mean age was 68 ± 14 years. Patients were at high surgical risk with median EuroSCORE II 27% (IQR 16, 28) and 20 out of 23 (87% were in cardiogenic shock). All patients were treated with vasopressors, and 17 out of 23 patients required mechanical support. TEER procedure was performed on the median 6 days after the index MI date IQR (3, 11). Procedural success was achieved in 87% of patients. The grade of MR was significantly decreased after the procedure. MR reduction to 0 or 1 + was achieved in 13 patients (57%), to 2 + in 7 patients (30%), P < 0.01. V-Wave was reduced from 49 ± 8 mmHg to 26 ± 10 mmHg post-procedure, P < 0.01. Sixteen out of 23 patients (70%) were discharged from hospital and 5 of them required reintervention with surgical mitral valve replacement. No additional death at 1 year was documented. CONCLUSIONS: TEER is a feasible therapy in critically ill patients with PMR due to a recent MI. TEER may have a role as salvage treatment or bridge to surgery in this population.


Asunto(s)
Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Músculos Papilares , Infarto del Miocardio/complicaciones , Choque Cardiogénico/etiología
5.
Eur Heart J Case Rep ; 8(2): ytae041, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38419752

RESUMEN

Background: Mitral regurgitation (MR) in the context of left ventricular systolic dysfunction is often designated as functional, with emphasis on the underlying cardiomyopathy leading to malcoaptation of the 'otherwise normal valve'. Case summary: A 63-year-old male with ischaemic cardiomyopathy (left ventricular ejection fraction 20%) presented with intractable heart failure in need of inotropic support and could not be stepped down from an ICU hospital setting. Functional MR, graded as moderate on transthoracic echocardiography, was initially not considered as pertinent to the clinical condition and options discussed included initiation of dialysis for volume management, chronic inotropic support, and palliative measures. However, a re-examination of the mitral valve by transoesophageal echo revealed severe regurgitation from annular dilatation and restricted mobility during systole. Transcatheter edge to edge repair utilizing the PASCAL device resulted in marked reduction of MR followed by an abrupt clinical improvement, weaning off inotropes and discharge home 4 days later. At four-year follow-up, the patient is stable on optimal heart failure therapy. Discussion: For many patients with heart failure and underlying cardiomyopathy, the presence of significant functional MR, instead of a 'bystander' disease, actually becomes the dominant driver of symptoms and compounds the low cardiac output state. In these patients, the term 'functional' MR becomes a misnomer, as in fact the so called 'otherwise normal' mitral valve is actually a severely dysfunctional valve with a wide malcoaptation zone. Transcatheter edge to edge repair is an effective bailout procedure for patients with low cardiac output and disproportionate severe functional MR.

6.
Catheter Cardiovasc Interv ; 102(1): 145-154, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37178388

RESUMEN

BACKGROUND: Mitral valve transcatheter edge-to-edge repair (M-TEER) is an effective option for treatment of mitral regurgitation (MR). We previously reported favorable 2-year outcomes for the PASCAL transcatheter valve repair system. OBJECTIVES: We report 3-year outcomes from the multinational, prospective, single-arm CLASP study with analysis by functional MR (FMR) and degenerative MR (DMR). METHODS: Patients with core-lab determined MR ≥ 3+ were deemed candidates for M-TEER by the local heart team. Major adverse events were assessed by an independent clinical events committee to 1 year and by sites thereafter. Echocardiographic outcomes were evaluated by the core laboratory to 3 years. RESULTS: The study enrolled 124 patients, 69% FMR; 31% DMR (60% NYHA class III-IVa, 100% MR ≥ 3+). The 3-year Kaplan-Meier estimate for survival was 75% (66% FMR; 92% DMR) and freedom from heart failure hospitalization (HFH) was 73% (64% FMR; 91% DMR), with 85% reduction in annualized HFH rate (81% FMR; 96% DMR) (p < 0.001). MR ≤ 2+ was achieved and maintained in 93% of patients (93% FMR; 94% DMR) and MR ≤ 1+ in 70% of patients (71% FMR; 67% DMR) (p < 0.001). The mean left ventricular end-diastolic volume (181 mL at baseline) decreased progressively by 28 mL [p < 0.001]. NYHA class I/II was achieved in 89% of patients (p < 0.001). CONCLUSIONS: The 3-year results from the CLASP study demonstrated favorable and durable outcomes with the PASCAL transcatheter valve repair system in patients with clinically significant MR. These results add to the growing body of evidence establishing the PASCAL system as a valuable therapy for patients with significant symptomatic MR.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios Prospectivos , Resultado del Tratamiento
7.
Eur Heart J ; 43(7): 641-650, 2022 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-34463727

RESUMEN

AIMS: Severe mitral regurgitation (MR) following acute myocardial infarction (MI) is associated with high mortality rates and has inconclusive recommendations in clinical guidelines. We aimed to report the international experience of patients with secondary MR following acute MI and compare the outcomes of those treated conservatively, surgically, and percutaneously. METHODS AND RESULTS: Retrospective international registry of consecutive patients with at least moderate-to-severe MR following MI treated in 21 centres in North America, Europe, and the Middle East. The registry included patients treated conservatively and those having surgical mitral valve repair or replacement (SMVR) or percutaneous mitral valve repair (PMVR) using edge-to-edge repair. The primary endpoint was in-hospital mortality. A total of 471 patients were included (43% female, age 73 ± 11 years): 205 underwent interventions, of whom 106 were SMVR and 99 PMVR. Patients who underwent mitral valve intervention were in a worse clinical state (Killip class ≥3 in 60% vs. 43%, P < 0.01), but yet had lower in-hospital and 1-year mortality compared with those treated conservatively [11% vs. 27%, P < 0.01 and 16% vs. 35%, P < 0.01; adjusted hazard ratio (HR) 0.28, 95% confidence interval (CI) 0.18-0.46, P < 0.01]. Surgical mitral valve repair or replacement was performed earlier than PMVR [median of 12 days from MI date (interquartile range 5-19) vs. 19 days (10-40), P < 0.01]. The immediate procedural success did not differ between SMVR and PMVR (92% vs. 93%, P = 0.53). However, in-hospital and 1-year mortality rates were significantly higher in SMVR than in PMVR (16% vs. 6%, P = 0.03 and 31% vs. 17%, P = 0.04; adjusted HR 3.75, 95% CI 1.55-9.07, P < 0.01). CONCLUSIONS: Early intervention may mitigate the poor prognosis associated with conservative therapy in patients with post-MI MR. Percutaneous mitral valve repair can serve as an alternative for surgery in reducing MR for high-risk patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Anciano , Anciano de 80 o más Años , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Infarto del Miocardio/complicaciones , Infarto del Miocardio/terapia , Estudios Retrospectivos , Resultado del Tratamiento
8.
JACC Cardiovasc Interv ; 14(14): 1538-1548, 2021 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-34020928

RESUMEN

OBJECTIVES: This study reports 2-year outcomes from the multicenter, prospective, single-arm CLASP study with functional mitral regurgitation (FMR) and degenerative MR (DMR) analysis. BACKGROUND: Transcatheter repair is a favorable option to treat MR. Long-term prognostic impact of the PASCAL transcatheter valve repair system in patients with clinically significant MR remains to be established. METHODS: Patients had clinically significant MR ≥3+ as evaluated by the echocardiographic core laboratory and were deemed candidates for transcatheter repair by the heart team. Assessments were performed by clinical events committee to 1 year (site-reported thereafter) and core laboratory to 2 years. RESULTS: A total of 124 patients (69% FMR, 31% DMR) were enrolled with a mean age of 75 years, 56% were male, 60% were New York Heart Association functional class III to IVa, and 100% had MR ≥3+. At 2 years, Kaplan-Meier estimates showed 80% survival (72% FMR, 94% DMR) and 84% freedom from heart failure (HF) hospitalization (78% FMR, 97% DMR), with 85% reduction in annualized HF hospitalization rate (81% FMR, 98% DMR). MR ≤1+ was achieved in 78% of patients (84% FMR, 71% DMR) and MR ≤2+ was achieved in 97% (95% FMR, 100% DMR) (all p < 0.001). Left ventricular end-diastolic volume decreased by 33 ml (p < 0.001); 93% of patients were in New York Heart Association functional class I to II (p < 0.001). CONCLUSIONS: The PASCAL repair system demonstrated sustained favorable outcomes at 2 years in FMR and DMR patients. Results showed high survival and freedom from HF rehospitalization rates with a significantly reduced annualized HF hospitalization rate. Durable MR reduction was achieved with evidence of left ventricular reverse remodeling and significant improvement in functional status. The CLASP IID/IIF randomized pivotal trial is ongoing.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Resultado del Tratamiento
9.
J Clin Med ; 10(9)2021 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-33921996

RESUMEN

Patients with severe mitral regurgitation (MR) after myocardial infarction (MI) have an increased risk of mortality. Transcatheter mitral valve repair may therefore be a suitable therapy. However, data on clinical outcomes of patients in an acute setting are scarce, especially those with reduced left ventricle (LV) dysfunction. We conducted a multinational, collaborative data analysis from 21 centers for patients who were, within 90 days of acute MI, treated with MitraClip due to severe MR. The cohort was divided according to median left ventricle ejection fraction (LVEF)-35%. Included in the study were 105 patients. The mean age was 71 ± 10 years. Patients in the LVEF < 35% group were younger but with comparable Euroscore II, multivessel coronary artery disease, prior MI and coronary artery bypass graft surgery. Procedure time was comparable and acute success rate was high in both groups (94% vs. 90%, p = 0.728). MR grade was significantly reduced in both groups along with an immediate reduction in left atrial V-wave, pulmonary artery pressure and improvement in New York Heart Association (NYHA) class. In-hospital and 1-year mortality rates were not significantly different between the two groups (11% vs. 7%, p = 0.51 and 19% vs. 12%, p = 0.49) and neither was the 3-month re-hospitalization rate. In conclusion, MitraClip intervention in patients with acute severe functional mitral regurgitation (FMR) due to a recent MI in an acute setting is safe and feasible. Even patients with severe LV dysfunction may benefit from transcatheter mitral valve intervention and should not be excluded.

10.
Hellenic J Cardiol ; 62(6): 423-428, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33617961

RESUMEN

BACKGROUND: Remote ischemic preconditioning (RIPC) is being evaluated as a strategy to reduce cardiac injury and inflammation in patients undergoing diverse cardiac invasive and surgical procedures. However, it is unclear whether RIPC has protective effects in patients undergoing the transfemoral- transcatheter aortic valve implantation (TF-TAVΙ) procedure. METHODS: Between September 2013 and September 2015, 55 random consecutive patients were prospectively assigned to receive SHAM preconditioning (SHAM, 22 patients) or Remote Ischemic Preconditioning (RIPC) (4 cycles of 5 min intermittent leg ischemia and 5 min reperfusion, 33 patients) prior to TF-TAVI. The primary endpoint was to determine the serum levels of: hs-cTn-I (necrosis), CK-18 (apoptosis), and IL-1b (inflammation). Quantification was performed using commercially available ELISA kits. Patients were sampled 1-day pre TF-TAVΙ and 24-hours post TF-TAVΙ. Secondary endpoints included: total mortality, incidence of periprocedural clinical acute myocardial infarction (AMI), acute kidney injury (AKI), and stroke. RESULTS: 22 SHAM patients and 33 RIPC patients were finally analyzed. Our data revealed no significant difference in serum levels of hs-cTn-I and CK-18 among various groups. However, in the RIPC group, the increase in IL1b level was significantly lower for 24-h post TF-TAVΙ, (p < 0.01). There were no significant differences between groups in the secondary endpoints at the follow-up interval of one month. RIPC-related adverse events were not observed. CONCLUSIONS: Our data suggest that RIPC did not exhibit significant cardiac or kidney protective effects regarding necrosis and apoptosis in patients undergoing TF-TAVΙ. However, an important anti-inflammatory effect was detected in the RIPC group.


Asunto(s)
Estenosis de la Válvula Aórtica , Precondicionamiento Isquémico Miocárdico , Precondicionamiento Isquémico , Infarto del Miocardio , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/cirugía , Humanos , Inflamación/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
11.
Hellenic J Cardiol ; 62(6): 416-422, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33617960

RESUMEN

BACKGROUND: Paravalvular leak (PVL) is a common complication following valve replacement, which leads to heart failure and hemolysis. Transcatheter PVL closure has emerged as a reliable alternative with promising results. We quote the combined three-center experience of PVL patients treated percutaneously. METHODS: Consecutive patients treated percutaneously for PVL were retrospectively studied. Procedural characteristics, inhospital, and long-term clinical outcomes were assessed. Technical (successful deployment) and clinical (NYHA and/or hemolysis improvement) success were evaluated. RESULTS: In total, 39 patients treated for PVL in either the aortic (12 patients) or the mitral (27 patients) position were studied. Amplatzer Vascular Plug III was the most commonly used device among the 45 devices totally implanted. Postprocedurally, the rates of at least moderate PVL (87.5% preprocedurally vs 10.5% at discharge) and functional status (mean NYHA class 2.8 ± 0.7 on admission vs 1.5 ± 0.8 at follow-up) were statistically significantly improved. Total population technical success rate was 89.7%, being comparable between patients treated for mitral or aortic valve PVLs (92.6% vs 83.3%, respectively). Clinical success was achieved in 82.1% of patient cohort without statistical difference among those with isolated aortic or mitral PVL or among those with PVL closure an indication of heart failure or hemolysis. During a mean follow-up of 33.5 months, five patients died, including one periprocedural death. CONCLUSIONS: This multicenter recorded experience confirms that percutaneous PVL closure can be performed with high technical and clinical success rates and limited complications that lead to significant PVL reduction and functional status improvement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Cateterismo Cardíaco , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Falla de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
12.
Clin Case Rep ; 9(2): 1024-1026, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33598290

RESUMEN

Transcatheter aortic valve implantation is a safe procedure even in inoperable patients with multi-organ failure and cardiogenic shock. In such cases, the heart team should be prepared to proceed to emergent implantation for timely and successful management of the patient.

13.
Catheter Cardiovasc Interv ; 97(6): 1259-1267, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33600072

RESUMEN

OBJECTIVES: To assess outcomes in patients with acute mitral regurgitation (MR) following acute myocardial infarction (AMI) who received percutaneous mitral valve repair (PMVR) with the MitraClip device and to compare outcomes of patients who developed cardiogenic shock (CS) to those who did not (non-CS). BACKGROUND: Acute MR after AMI may lead to CS and is associated with high mortality. METHODS: This registry analyzed patients with MR after AMI who were treated with MitraClip at 18 centers within eight countries between January 2016 and February 2020. Patients were stratified into CS and non-CS groups. Primary outcomes were mortality and rehospitalization due to heart failure. Secondary outcomes were acute procedural success, functional improvement, and MR reduction. Multivariable Cox regression analysis evaluated association of CS with clinical outcomes. RESULTS: Among 93 patients analyzed (age 70.3 ± 10.2 years), 50 patients (53.8%) experienced CS before PMVR. Mortality at 30 days (10% CS vs. 2.3% non-CS; p = .212) did not differ between groups. After median follow-up of 7 months (IQR 2.5-17 months), the combined event mortality/re-hospitalization was similar (28% CS vs. 25.6% non-CS; p = .793). Likewise, immediate procedural success (90% CS vs. 93% non-CS; p = .793) and need for reintervention (CS 6% vs. non-CS 2.3%, p = .621) or re-admission due to HF (CS 13% vs. NCS 23%, p = .253) at 3 months did not differ. CS was not independently associated with the combined end-point (hazard ratio 1.1; 95% CI, 0.3-4.6; p = .889). CONCLUSIONS: Patients found to have significant MR during their index hospitalization for AMI had similar clinical outcomes with PMVR whether they presented in or out of cardiogenic shock, provided initial hemodynamic stabilization was first achieved before PMVR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Anciano , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Infarto del Miocardio/complicaciones , Sistema de Registros , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Resultado del Tratamiento
14.
Circulation ; 143(2): 104-116, 2021 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-32975133

RESUMEN

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/normas , Válvula Mitral/cirugía , Sistema de Registros , Reoperación/normas , Reemplazo de la Válvula Aórtica Transcatéter/normas , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Prótesis Valvulares Cardíacas/tendencias , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Reoperación/tendencias , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/tendencias
15.
JACC Cardiovasc Interv ; 13(20): 2344-2357, 2020 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-33092709

RESUMEN

OBJECTIVES: The authors report the CLASP (Edwards PASCAL Transcatheter Mitral Valve Repair System Study) expanded experience, 1-year outcomes, and analysis by functional mitral regurgitation (FMR) and degenerative mitral regurgitation (DMR). BACKGROUND: The 30-day results from the CLASP study of the PASCAL transcatheter valve repair system for clinically significant mitral regurgitation (MR) have been previously reported. METHODS: Eligible patients had symptomatic MR ≥3+, were receiving optimal medical therapy, and were deemed candidates for transcatheter mitral repair by the local heart team. Primary endpoints included procedural success, clinical success, and major adverse event rate at 30 days. Follow-up was continued to 1 year. RESULTS: One hundred nine patients were treated (67% FMR, 33% DMR); the mean age was 75.5 years, and 57% were in New York Heart Association functional class III or IV. At 30 days, there was 1 cardiovascular death (0.9%), MR ≤1+ was achieved in 80% of patients (77% FMR, 86% DMR) and MR ≤2+ in 96% (96% FMR, 97% DMR), 88% of patients were in New York Heart Association functional class I or II, 6-min walk distance had improved by 28 m, and Kansas City Cardiomyopathy Questionnaire score had improved by 16 points (p < 0.001 for all). At 1 year, Kaplan-Meier survival was 92% (89% FMR 96% DMR) with 88% freedom from heart failure hospitalization (80% FMR, 100% DMR), MR was ≤1+ in 82% of patients (79% FMR, 86% DMR) and ≤2+ in 100% of patients, 88% of patients were in New York Heart Association functional class I or II, and Kansas City Cardiomyopathy Questionnaire score had improved by 14 points (p < 0.001 for all). CONCLUSIONS: The PASCAL transcatheter valve repair system demonstrated a low complication rate and high survival, with robust sustained MR reduction accompanied by significant improvements in functional status and quality of life at 1 year. (The CLASP Study Edwards PASCAL Transcatheter Mitral Valve Repair System Study [CLASP]; NCT03170349).


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Resultado del Tratamiento
16.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32592401

RESUMEN

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
17.
ESC Heart Fail ; 7(4): 1409-1418, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32432839

RESUMEN

AIMS: The purpose of this study is to identify echocardiography predictors of clinical response and reverse left ventricular (LV) remodelling in patients with functional mitral regurgitation (FMR) treated with MitraClip. METHOD AND RESULTS: We retrospectively analysed 86 high surgical risk patients with severe FMR; of those, 58 were implanted a MitraClip, and 28 received medical treatment and served as controls. At baseline and at 1-year follow-up, we performed clinical and echocardiography evaluation to assess global longitudinal strain (GLS) and myocardial work [global work index (GWI), global constructive work (GCW), global wasted work (GWW), global work efficiency (GWE)]. Mitral regurgitation was significantly reduced after MitraClip implantation (3.7 ± 0.4 vs. 1.7 ± 0.8, P < 0.001), and the procedure was associated with improvement in brain natriuretic peptide levels (980 ± 1027 vs. 420 ± 338 pg/mL, P < 0.001), New York Heart Association class status (3.2 ± 0.55 vs. 2.0 ± 0.6, P < 0.001), 6-min walking test (233 ± 154 vs. 286 ± 114 m, P = 0.01) at follow-up and reduction of left ventricle end-systolic (LVESV) and left ventricle end-diastolic volumes (LVEDV) (152 ± 68 vs. 136 ± 43 mL, P = 0.004 & 219 ± 74 vs. 193 ± 66 mL, P = 0.001, respectively). MitraClip procedure was associated with improvement of LV performance and significant increase of GWI (607 ± 282 vs. 650 ± 260 mmHg%, P = 0.045) and GCW (854 ± 288 vs. 949 ± 325 mmHg%, P < 0.001). Baseline ejection fraction (EF), GLS, GWI, GCW, and effective regurgitant orifice area were the variables that were associated with reduction of LVEDV 1 year after intervention (P < 0.05 for all) and baseline GCW of the LV was the only variable associated with reduction of LVESV (P = 0.002). Receiver operating characteristic curve analysis identified that a GLS cut-off value of -8.65% (AUC 0.815, P = 0.007) was associated with a 20% reduction of the LVEDV with a sensitivity and specificity of 72% and 70%, respectively, and that a GCW cut-off value of 846 mmHg% (AUC 0.759, P = 0.007) was associated with a 10% reduction of LVESV with sensitivity and specificity 79% and 74%, respectively. CONCLUSIONS: Mitral valve repair with MitraClip has positive clinical and echocardiographic impact in patients with FMR 1 year after implantation. Preserved GLS and GCW values appear to be associated with LV reverse remodelling post intervention.


Asunto(s)
Insuficiencia de la Válvula Mitral , Remodelación Ventricular , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos
19.
JACC Cardiovasc Interv ; 12(23): 2402-2412, 2019 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-31629753

RESUMEN

OBJECTIVES: This study proposes a physiologic assessment of left ventricular outflow tract obstruction (LVOTO) that accommodates changes in systolic flow and accounts for the dynamic neo-left ventricular outflow tract (LVOT). BACKGROUND: Patients considered for transcatheter mitral valve replacement trials often screen-fail because of the perceived risk of LVOTO. In the Intrepid Global Pilot Study, assumed risk of LVOTO was based on computed tomography estimates of the neo-LVOT area computed at end-systole. However, this may overestimate actual risk. METHODS: Retrospective analyses were performed for screen-failed patients for potential LVOTO (n = 33) and treated patients (n = 29) with available dynamic computed tomography. A multiphase assessment of the neo-LVOT area was performed and represented as: 1) multiphase average; and 2) early systolic value. Prospective evaluation was performed in 9 patients approved for enrollment with multiphase and early systole methods that would have previously screen-failed with the end-systolic approach. RESULTS: Of 166 patients screened for possible inclusion; 32 were screen-failed for nonanatomical reasons. Screen failure for assumed LVOTO risk occurred in 37 of 134 (27.6%) patients. Retrospective analysis indicated a potential enrollment increase of 11 of 33 (33.3%) and 18 of 33 (54.5%) patients using multiphase and early systolic assessment methods. In the prospective cohort, there were no clinical observations of LVOTO 30 days post-procedure, despite assumed risk based on end-systolic estimates. CONCLUSIONS: Multiphase, and specifically early systolic, assessment of the neo-LVOT may better determine risk of LVOTO with transcatheter mitral valve replacement compared with end-systolic estimates. This novel approach has the potential to significantly increase patient eligibility, with over one-half of patients previously screen-failed now eligible for treatment.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/cirugía , Tomografía Computarizada por Rayos X , Obstrucción del Flujo Ventricular Externo/etiología , Cateterismo Cardíaco/instrumentación , Ecocardiografía Doppler de Pulso , Ecocardiografía Transesofágica , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Función Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/fisiopatología
20.
JACC Cardiovasc Interv ; 12(16): 1606-1617, 2019 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-31439340

RESUMEN

OBJECTIVES: This study sought to evaluate SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, California) positioning using different strategies. BACKGROUND: Aortic valve-in-valve (ViV) is associated with high risk of elevated gradients. METHODS: S3 aortic ViV procedures in stented bioprostheses were studied. Transcatheter heart valve (THV) positioning was analyzed in a centralized core lab blinded to clinical outcomes. A combined endpoint of severely elevated mean gradient (≥30 mm Hg) or pacemaker need was established. Two positioning strategies were compared: central marker method and top of S3 method. Optimal final depth was defined as S3 depth ≤20%. RESULTS: A total of 113 patients met inclusion criteria and were analyzed (76.5 ± 9.7 years of age, 65.8% male, STS score 8 ± 7.6%). THVs had incomplete shortening in comparison to fully expanded valves (92 ± 3.4%), and expansion was more complete in optimal positioning cases compared with others (93.2 ± 2.7% vs. 91.5 ± 3.5%; p = 0.027). The central marker method demonstrated greater correlation with final implantation depth than the top of S3 method (R2 of 0.48 and 0.14; p < 0.001 and p = 0.001, respectively). The combined endpoint rate was 4.3% in the optimal (higher than 3 mm) implantation group, 12% in the intermediate group, and 50% in the low group (p < 0.001). There were no cases of THV embolization. In cases with central marker higher than 3 mm, 72.4% had optimal final depth. In those with central marker higher than 6 mm, 90% had optimal final depth. CONCLUSIONS: Optimal S3 positioning in aortic ViV is associated with better outcomes. Central marker positioning is more reliable than top of S3 positioning. Central marker bottom position should be 3 mm to 6 mm above the ring.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA