Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Nucl Med ; 49(6): 557-558, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38598452

RESUMEN

ABSTRACT: We report the successful application of radioembolization (SIRT) in a 77-year-old man with end-stage renal disease on hemodialysis and repeated episodes of macroscopic hematuria due to a large renal cell carcinoma of the right kidney extending to liver segment VI. A compassionate SIRT therapy was performed with resin microspheres through the upper pole renal artery and the feeding segmental artery of liver segment VI. Hematuria was resolved after treatment, and 4 months later, a follow-up CT scan revealed tumor size reduction and complete tumor necrosis (Response Evaluation Criteria in Solid Tumors criteria). Ablative SIRT therapy could be a safe and efficient option in a large inoperable RCC.


Asunto(s)
Carcinoma de Células Renales , Embolización Terapéutica , Hematuria , Neoplasias Renales , Humanos , Masculino , Anciano , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/radioterapia , Carcinoma de Células Renales/complicaciones , Carcinoma de Células Renales/patología , Hematuria/etiología , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Neoplasias Renales/radioterapia , Neoplasias Renales/complicaciones , Necrosis , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/complicaciones , Invasividad Neoplásica , Hígado/diagnóstico por imagen , Hígado/patología , Tomografía Computarizada por Rayos X
2.
Artículo en Inglés | MEDLINE | ID: mdl-38083146

RESUMEN

Coronary artery disease (CAD) is a chronic disease associated with high mortality and morbidity. Although treatment with drug-eluting stents is the most frequent interventional approach for coronary artery disease, drug-coated balloons (DCBs) constitute an innovative alternative, especially in the presence of certain anatomical conditions in the local coronary vasculature. DCBs allow the fast and homogenous transfer of drugs into the arterial wall, during the balloon inflation. Their use has been established for treating in-stent restenosis caused by stent implantation, while recent clinical trials have shown a satisfactory efficacy in de novo small-vessel disease. Several factors affect DCBs performance including the catheter design, the drug dose and formulation. Cleverballoon focuses on the design and development of an innovative DCB with everolimus. For the realization of the development of this new DCB, an integrated approach, including in- vivo, in-vitro studies and in-silico modelling towards the DCB optimization, is presented.Clinical Relevance-The proposed study introduces the integration of in- vivo, in-vitro and in silico approaches in the design and development process of a new DCB, following the principles of 3R's for the replacement, reduction, and refinement of animal and clinical studies.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Animales , Enfermedad de la Arteria Coronaria/terapia , Everolimus/farmacología , Resultado del Tratamiento
3.
Sci Rep ; 12(1): 13909, 2022 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-35977960

RESUMEN

Coronary angiography and percutaneous coronary intervention (PCI) procedural details in swine are similar to those performed to humans, since their heart and coronary anatomy closely resembles. However, only a few detailed descriptions of the procedure are available, containing notable differences. We present a feasible and reproducible protocol for percutaneous coronary interventions in porcine experimental models, utilizing ultrasound-guided femoral approach. Nine female pigs were studied to explore the feasibility of superficial femoral arterial (SFA) access for coronary angiography and provisional PCI, as well as the most suitable guiding coronary catheters and angiographic projections for the above interventions. Experiments were performed under general anesthesia, using ultrasound-guided puncture of the SFA to gain arterial access. The Amplatzer AR1® catheter, and the Right Coronary Bypass® catheter were used for the selective engagement of the right and the left coronary artery, respectively. Successful arterial access and subsequent cardiac catheterization were performed in all pigs. Only one animal required a second puncture for femoral artery access. None of the 9 animals presented any significant tachycardia or hypotensive episode. One animal developed an access site-related complication following the first catheterization procedure. During follow-up, 100% success of SFA catheterization was achieved using the same ultrasound-guided technique. The ultrasound-guided superficial femoral artery access for coronary angiography and provisional interventions in porcine models is a quick and safe alternative to the carotid artery approach. The RCB and AR1 catheters may be the best choice for the quick and easy selective coronary engagement of the right and left ostia, respectively.


Asunto(s)
Arteria Femoral , Intervención Coronaria Percutánea , Animales , Cateterismo Cardíaco/métodos , Angiografía Coronaria/métodos , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Humanos , Intervención Coronaria Percutánea/métodos , Arteria Radial , Porcinos , Resultado del Tratamiento , Ultrasonografía Intervencional
4.
J Vasc Interv Radiol ; 30(2): 212-216, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30717952

RESUMEN

PURPOSE: A retrospective longitudinal analysis was performed to evaluate the outcome of consecutive treatments with drug-coated balloons (DCBs) in dysfunctional arteriovenous (AV) dialysis access (fistulae and grafts). MATERIALS AND METHODS: From January 2015 to December 2017, 339 DCBs were used in 257 procedures in 165 patients with dysfunctional accesses. Of these, 38 patients had ≥ 2 procedures and were included in the analysis. A total of 112 procedures were performed with 133 devices (22 patients treated twice, 4 treated 3 times, 7 treated 4 times, 2 treated 5 times, and 3 treated 6 times). Mean balloon diameter was 8.13 mm (min-max range, 3-12 mm) and length was 63.16 mm (min-max range, 40-150 mm). Primary outcome measures were safety and effectiveness based on the noninferiority hypothesis that the second treatment would be as effective as the first regarding postintervention primary patency (PIPP). Secondary outcome measures included independent factors that may influence outcomes. RESULTS: Mean lesion follow-up was 617 d (range, 175-1,100 d). Median PIPP durations were 216.5 d for the first intervention and 280 d for the second (P = .37; hazard ratio, 1.271; 95% confidence interval, 0.75-2.16). There was a significant difference in PIPP in favor of the second intervention when patients with only 2 interventions (22 of 38; 57.9%) were included (first intervention, 269 d; second intervention, 520 d; P = .03; hazard ratio, 2.354; 95% confidence interval, 1.087-5.098). CONCLUSIONS: There was no significant difference in PIPP between the first and second DCB procedures. Results suggest consistency in PIPP with the use of DCBs regardless of aging AV access.


Asunto(s)
Angioplastia de Balón/instrumentación , Derivación Arteriovenosa Quirúrgica/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Oclusión de Injerto Vascular/terapia , Diálisis Renal , Dispositivos de Acceso Vascular , Grado de Desobstrucción Vascular , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Diseño de Equipo , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/fisiopatología , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA