Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
1.
ASAIO J ; 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38941597

RESUMEN

Although current studies support the use of prophylactic distal perfusion catheters (DPCs) to decrease limb ischemia in patients on venoarterial extracorporeal membrane oxygenation (VA ECMO), methods for monitoring limb ischemia differ between studies. We evaluated the safety of a selective rather than prophylactic DPC strategy at a single center with a well-established protocol for limb ischemia monitoring. Distal perfusion catheters were placed selectively if there was evidence of hypoperfusion at any point until decannulation. All patients were followed daily by vascular surgery with continuous regional saturation monitoring. Of 188 patients supported with VA ECMO, there were no significant differences in baseline characteristics between patients with upfront, delayed, and no DPC. Thirty day mortality was highest in patients with an upfront DPC (56% in the upfront DPC group, 19% in the delayed DPC group, and 22% in the no-DPC group, p < 0.001). The incidence of major bleeding, fasciotomy, and amputation in the entire cohort was 3.7%, 3.7%, and 0%, respectively. With strict adherence to a protocol for limb ischemia monitoring, a selective rather than prophylactic DPC strategy is safe and may obviate the risks of an additional arterial catheter.

3.
Circ Cardiovasc Interv ; : e013903, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38934113

RESUMEN

BACKGROUND: SAPIEN3 (S3) is a ubiquitous redo-transcatheter aortic valve (TAV) replacement alternative for degenerated Evolut valves, but S3 sizing for S3-in-Evolut remains unclear. We sought to compare the impact of in vivo computed tomography (CT)-sizing on redo-TAV feasibility for S3-in-Evolut with traditional bench-sizing. METHODS: CT scans of 290 patients treated using Evolut R/PRO/PRO+ between July 2015 and December 2021 were analyzed. S3-in-Evolut was simulated using S3 outflow/neoskirt plane (NSP) at node-6, -5, and -4. CT-sizing for S3 was determined by averaging 4 areas of the Evolut stent frame at NSP level and 3 nodes below. Redo-TAV was deemed feasible if the NSP was below the coronaries, or the narrowest valve (virtual S3)-to-aorta distance was >4 mm. Risk of prosthesis-patient mismatch was estimated using predicted indexed-effective orifice area. RESULTS: Compared with bench-sizing, CT-sizing yielded smaller S3 size in 82% at node-6, 81% at node-5, and 84% at node-4. Factors associated with CT-sizing less than bench-sizing were larger index Evolut size, underexpansion of index Evolut, and shallower implant depth (all P<0.05). CT-sizing increased redo-TAV feasibility by +8% at node-6, +10% at node-5, and +4% at node-4. Redo-TAV feasibility increased with annulus size, sinotubular junction dimensions, coronary heights, index Evolut size, deeper Evolut implant depth, and lower NSP levels (all P<0.05). CT-sizing had a slightly higher estimated risk of severe prosthesis-patient mismatch (9% at node-6, 7% at node-5, and 6% at node-4), which could be mitigated by changing the NSP. CONCLUSIONS: CT-sizing for S3-in-Evolut is associated with higher feasibility of redo-TAV compared with bench-sizing, potentially reducing the risk of excessive oversizing and S3 underexpansion. Further validation using real-world clinical data is necessary.

5.
J Vasc Surg ; 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38723909

RESUMEN

OBJECTIVE: To evaluate the impact of celiac artery (CA) compression by median arcuate ligament (MAL) on technical metrics and long-term CA patency in patients with complex aortic aneurysms undergoing fenestrated/branched endograft repairs (F/B-EVARs). METHODS: Single-center, retrospective review of patients undergoing fenestrated/branched endovascular aortic aneurysm repairs and requiring incorporation of the CA between 2013 and 2023. Patients were divided into two groups-those with (MAL+) and without (MAL-) CA compression-based on preoperative computed tomography angiography findings. MAL was classified in three grades (A, B, and C) based on the degree and length of stenosis. Patients with MAL grade A had ≤50% CA stenosis measuring ≤3 mm in length. Those with grade B had 50% to 80% CA stenosis measuring 3 to 8 mm long, whereas those with grade C had >80% stenosis measuring >8 mm in length. End points included device integrity, CA patency and technical success-defined as successful implantation of the fenestrated/branched device with perfusion of CA and no endoleak. RESULTS: One hundred and eighty patients with complex aortic aneurysms (pararenal, 128; thoracoabdominal, 52) required incorporation of the CA during fenestrated/branched endovascular aortic aneurysm repair. Majority (73%) were male, with a median age of 76 years (interquartile range [IQR], 69-81 years) and aneurysm size of 62 mm (IQR, 57-69 mm). Seventy-eight patients (43%) had MAL+ anatomy, including 33 patients with MAL grade A, 32 with grade B, and 13 with grade C compression. The median length of CA stenosis was 7.0 mm (IQR, 5.0-10.0 mm). CA was incorporated using fenestrations in 177 (98%) patients. Increased complexity led to failure in CA bridging stent placement in four MAL+ patients, but completion angiography showed CA perfusion and no endoleak, accounting for a technical success of 100%. MAL+ patients were more likely to require bare metal stenting in addition to covered stents (P = .004). Estimated blood loss, median operating room time, contrast volume, fluoroscopy dose and time were higher (P < .001) in MAL+ group. Thirty-day mortality was 3.3%, higher (5.1%) in MAL+ patients compared with MAL- patients (2.0 %). At a median follow-up of 770 days (IQR, 198-1525 days), endograft integrity was observed in all patients and CA events-kinking (n = 7), thrombosis (n = 1) and endoleak (n = 2) -occurred in 10 patients (5.6%). However, only two patients required reinterventions. MAL+ patients had overall lower long-term survival. CONCLUSIONS: CA compression by MAL is a predictor of increased procedural complexity during fenestrated/branched device implantation. However, technical success, long-term device integrity and CA patency are similar to that of patients with MAL- anatomy.

6.
J Invasive Cardiol ; 36(6)2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38446023

RESUMEN

BACKGROUND: The impact of contrast type on coronary optical coherence tomography (OCT) imaging has received limited research. METHODS: We conducted a blinded, prospective, single-center, randomized, controlled crossover study comparing iso-osmolar contrast media (IOCM) with low-osmolar contrast media (LOCM) in patients undergoing clinically indicated coronary OCT imaging. Patients were randomly assigned to undergo OCT imaging with either IOCM or LOCM as the initial contrast medium. Following a washout period, a second run of OCT imaging of the same coronary vessel was performed using the other contrast medium. RESULTS: A total of 62 patients were randomized to IOCM first (n = 31) or LOCM first (n = 31). Mean patient age was 65.9 ± 11.2 years and 74.2% were male, with high prevalence of dyslipidemia (82.3%) and prior myocardial infarction (41.9%). Percutaneous coronary intervention was performed in 60 cases (96.8%) and the left anterior descending artery was the most common target vessel (53.3%). The contrast volume used for OCT imaging was similar for IOCM and LOCM (8.0 [6.9, 9.0] mL vs 8.0 [6.7, 9.0] mL; P = .89), as was the length of clear OCT images (70.0 [62.8, 74.0] mm for IOCM vs 70.0 [64.0, 74.0] mm for LOCM; P = .65). Electrocardiographic changes were observed in 11 runs with IOCM (ventricular repolarization changes in 9 runs and premature ventricular contractions [PVCs] in 2 runs) vs 12 runs with LOCM (ventricular repolarization changes in 9 runs and PVCs in 3 runs). CONCLUSIONS: The use of IOCM in coronary OCT is associated with similar contrast volume and clear imaging length when compared with LOCM.


Asunto(s)
Medios de Contraste , Vasos Coronarios , Estudios Cruzados , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Masculino , Femenino , Medios de Contraste/efectos adversos , Medios de Contraste/administración & dosificación , Anciano , Estudios Prospectivos , Vasos Coronarios/diagnóstico por imagen , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/diagnóstico , Método Simple Ciego , Intervención Coronaria Percutánea/métodos
7.
Catheter Cardiovasc Interv ; 103(5): 695-702, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38419416

RESUMEN

BACKGROUND: The use of the Indigo CAT RX Aspiration System (Penumbra Inc.) during percutaneous coronary intervention has received limited study. METHODS: We retrospectively examined the clinical, angiographic, and procedural characteristics, outcomes, and follow-up of patients who underwent mechanical aspiration thrombectomy with the Indigo CAT RX system (Penumbra Inc.) at a large tertiary care hospital between January 2019 and April 2023. RESULTS: During the study period, 83 patients (85 lesions) underwent thrombectomy with the Indigo CAT RX. Mean patient age was 64.9 ± 14.48 years and 31.2% were women. The most common presentations were ST-segment elevation myocardial infarction (MI) (66.2%) and non-ST-segment elevation MI (26.5%). A final thrombolysis in MI flow grade of 3 and final myocardial blush grade of 3 were achieved in 76% and 46% of the cases, respectively. Technical success was achieved in 88.9% of the cases that included Indigo CAT RX treatment only, compared with 57.1% of the cases that also included manual aspiration. There were no device-related serious adverse events. At 30-day postprocedure, the incidence of major adverse cardiac events (composite of cardiovascular death, recurrent MI, cardiogenic shock, new or worsening New York Heart Association Class IV heart failure, stroke) was 8.5%: 1.3% stroke (postprocedure, in-hospital), 1.3% MI, 6.1% cardiac death, and 7.5% developed cardiogenic shock. CONCLUSIONS: Use of the Indigo CAT RX system is associated with high technical success and acceptable risk of complications, including stroke.


Asunto(s)
Trombosis Coronaria , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Accidente Cerebrovascular , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Carmin de Índigo , Choque Cardiogénico/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Trombectomía/efectos adversos , Infarto del Miocardio con Elevación del ST/terapia , Accidente Cerebrovascular/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Trombosis Coronaria/etiología
8.
Ann Thorac Surg ; 117(6): 1154-1162, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38382704

RESUMEN

BACKGROUND: Selection of transcatheter valve size using preprocedural computed tomography (CT) is standardized and well established. However, valve sizing for surgical aortic valve replacement (SAVR) is currently performed intraoperatively by using sizers, which may result in variation among operators and risk for prosthesis-patient mismatch. This study evaluated the usefulness of CT annulus measurement for SAVR valve sizing. METHODS: This study included patients who underwent SAVR using Inspiris or Magna Ease and received preoperative electrocardiogram-gated CT imaging. Starting from June 2022, study investigators applied a CT sizing algorithm using CT-derived annulus size to guide minimum SAVR label size. The final decision of valve selection was left to the operating surgeon during SAVR. The study compared the appropriateness of valve selection (comparing implanted size with CT-predicted size) and prosthesis-patient mismatch rates without aortic root enlargement between 2 cohorts: 102 cases since June 2022 (CT sizing cohort) and 180 cases from 2020 to 2021 (conventional sizing cohort). RESULTS: Implanted size smaller than CT predicted size and severe prosthesis-patient mismatch were significantly lower by CT sizing than by conventional sizing (12% vs 31% [P = .001] and 0% vs 6% [P = .039], respectively). Interoperator variability was a factor associated with implanted size smaller than CT predicted with conventional sizing, whereas it became nonsignificant with CT sizing. CONCLUSIONS: Applying CT sizing to SAVR led to improved valve size selection, less prosthesis-patient mismatch, and less interoperator variability. CT sizing for SAVR could also be used to predict prosthesis-patient mismatch before SAVR and identify patients who need aortic root enlargement.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Tomografía Computarizada por Rayos X/métodos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Anciano , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Anciano de 80 o más Años , Cuidados Preoperatorios/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
9.
Am Heart J ; 271: 112-122, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38395293

RESUMEN

BACKGROUND: To date, there has been no independent core lab angiographic analysis of patients with COVID-19 and STEMI. The study characterized the angiographic parameters of patients with COVID-19 and STEMI. METHODS: Angiograms of patients with COVID-19 and STEMI from the North American COVID-19 Myocardial Infarction (NACMI) Registry were sent to a Core Laboratory in Vancouver, Canada. Culprit lesion(s), Thrombolysis In Myocardial Infarction (TIMI) flow, Thrombus Grade Burden (TGB), and percutaneous coronary intervention (PCI) outcome were assessed. RESULTS: From 234 patients, 74% had one culprit lesion, 14% had multiple culprits and 12% had no culprit identified. Multivessel thrombotic disease and multivessel CAD were found in 27% and 53% of patients, respectively. Stent thrombosis accounted for 12% of the presentations and occurred in 55% of patients with previous coronary stents. Of the 182 who underwent PCI, 60 (33%) had unsuccessful PCI due to post-PCI TIMI flow <3 (43/60), residual high thrombus burden (41/60) and/or thrombus related complications (27/60). In-hospital mortality for successful, partially successful, and unsuccessful PCI was 14%, 13%, and 27%, respectively. Unsuccessful PCI was associated with increased risk of in-hospital mortality (risk ratio [RR] 1.96; 95% CI: 1.05-3.66, P = .03); in the adjusted model this estimate was attenuated (RR: 1.24; 95% CI: 0.65-2.34, P = .51). CONCLUSION: In patients with COVID-19 and STEMI, thrombus burden was pervasive with notable rates of multivessel thrombotic disease and stent thrombosis. Post-PCI, persistent thrombus and sub-optimal TIMI 3 flow rates led to one-third of the PCI's being unsuccessful, which decreased over time but remained an important predictor of in-hospital mortality.


Asunto(s)
COVID-19 , Angiografía Coronaria , Intervención Coronaria Percutánea , Sistema de Registros , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , COVID-19/complicaciones , COVID-19/terapia , Masculino , Femenino , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/estadística & datos numéricos , Persona de Mediana Edad , Anciano , Mortalidad Hospitalaria , SARS-CoV-2 , Trombosis Coronaria/diagnóstico por imagen , Canadá/epidemiología
11.
JACC Cardiovasc Imaging ; 17(4): 396-407, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37921717

RESUMEN

BACKGROUND: Quantification of myocardial changes in severe aortic stenosis (AS) is prognostically important. The potential for comprehensive myocardial assessment pre-transcatheter aortic valve replacement (TAVR) by computed tomography angiography (CTA) is unknown. OBJECTIVES: This study sought to evaluate whether quantification of left ventricular (LV) extracellular volume-a marker of myocardial fibrosis-and global longitudinal strain-a marker of myocardial deformation-at baseline CTA associate with post-TAVR outcomes. METHODS: Consecutive patients with symptomatic severe AS between January 2021 and June 2022 who underwent pre-TAVR CTA were included. Computed tomography extracellular volume (CT-ECV) was derived from septum tracing after generating the 3-dimensional CT-ECV map. Computed tomography global longitudinal strain (CT-GLS) used semi-automated feature tracking analysis. The clinical endpoint was the composite outcome of all-cause mortality and heart failure hospitalization. RESULTS: Among the 300 patients (80.0 ± 9.4 years of age, 45% female, median Society of Thoracic Surgeons Predicted Risk of Mortality score 2.80%), the left ventricular ejection fraction (LVEF) was 58% ± 12%, the median CT-ECV was 28.5% (IQR: 26.2%-32.1%), and the median CT-GLS was -20.1% (IQR: -23.8% to -16.3%). Over a median follow-up of 16 months (IQR: 12-22 months), 38 deaths and 70 composite outcomes occurred. Multivariable Cox proportional hazards model, accounting for clinical and echocardiographic variables, demonstrated that CT-ECV (HR: 1.09 [95% CI: 1.02-1.16]; P = 0.008) and CT-GLS (HR: 1.07 [95% CI: 1.01-1.13]; P = 0.017) associated with the composite outcome. In combination, elevated CT-ECV and CT-GLS (above median for each) showed a stronger association with the outcome (HR: 7.14 [95% CI: 2.63-19.36]; P < 0.001). CONCLUSIONS: Comprehensive myocardial quantification of CT-ECV and CT-GLS associated with post-TAVR outcomes in a contemporary low-risk cohort with mostly preserved LVEF. Whether these imaging biomarkers can be potentially used for the decision making including timing of AS intervention and post-TAVR follow-up will require integration into future clinical trials.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Función Ventricular Izquierda , Volumen Sistólico , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Estudios Retrospectivos
12.
J Vasc Surg ; 79(5): 1101-1109, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38103807

RESUMEN

OBJECTIVE: To evaluate outcomes and performance of inverted limbs (ILs) when used in conjunction with Zenith fenestrated stent grafts (Zfens) to treat patients with short distance between the lowest renal artery (RA) and aortic or graft bifurcation (A/GB). METHODS: This study was a multicenter, retrospective review of prospectively maintained database of patients with complex aortic aneurysms, failed endovascular aneurysm repair (EVAR), or open surgical repair (OSR) with short distance between LRA and A/GB treated using a combination of Zfen and an IL between 2013 and 2023. Endpoints included technical success, aneurysm sac regression, long-term device integrity, and target vessel patency. We defined technical success as implantation of the device with no endoleak, conversion to an aorto-uni-iliac or OSR. RESULTS: During this time, 52 patients underwent endovascular rescue of failed repair. Twenty (38.5%) of them required relining of the failed repairs using IL due to lowest RA to A/GB length restrictions. Two patients had undergone rescue with a fenestrated cuff alone but developed type III endoleaks. One patient with no previous implant had a short distance between the lowest RA and aortic bifurcation to accommodate the bifurcated distal device, and two patients had failed OSR or anastomotic pseudoaneurysms. The majority (94%) were men with a mean age of 76.8 ± 6.1 years. The mean aortic neck diameter and aneurysm size were 32 ± 4 cm and 7.2 ± 1.3 cm, respectively. The median time laps between initial repair and failure was 36 months (interquartile range [IQR], 24-54 months). Sixteen patients (80%) were classified as American Society of Anesthesiologists class III, whereas four were class IV. Seventy-eight vessels were targeted and successfully incorporated. Technical success was 100%, and median estimated blood loss was 100 mL (IQR, 100-200 mL). Mean fluoroscopy time and dose were 61 ± 18 minutes and 2754 ± 1062 mGy, respectively. Average hospital length of stay was 2.75 ± 2.15 days. Postoperative complication occurred in one patient who required lower extremity fasciotomy for compartment syndrome. At a median follow-up of 50 months (IQR, 18-58 months), there were no device migration, components separation, aneurysmal related mortality, and type I or type III endoleak. Aneurysm sac regression (95%) or stabilization (5%) was observed in all patients, including in four patients (25%) with type II endoleak. CONCLUSIONS: The use of IL in conjunction with Zfen to treat patients with short distance between the lowest RA and A/GB is safe, effective, and has excellent long-term results. The technique expands the indication of Zfen, especially in patients with failed previous EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Médicos , Masculino , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Prótesis Vascular , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/etiología , Stents , Endofuga/etiología , Endofuga/cirugía , Factores de Riesgo , Resultado del Tratamiento , Diseño de Prótesis , Estudios Retrospectivos
13.
JAMA Netw Open ; 6(11): e2343402, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37971742

RESUMEN

Importance: The clinical characteristics and prognosis of patients with ST-segment elevation myocardial infarction (STEMI) with nonobstructive coronaries (MINOCA) are largely unknown. Objective: To assess differences in 5-year mortality in patients presenting with STEMI due to MINOCA and MINOCA mimickers as compared with obstructive disease. Design, Setting, and Participants: A retrospective analysis of a prospective registry-based cohort study of consecutive STEMI activations at 3 regional Midwest STEMI programs. STEMI without a culprit artery and elevated troponin levels were categorized as MINOCA (absence of coronary artery stenosis >50% and confirmed or suspected coronary artery plaque disruption, epicardial coronary spasm, or coronary embolism/thrombosis) or MINOCA mimickers (takotsubo cardiomyopathy, myocarditis, or nonischemic cardiomyopathy). Data were analyzed from March 2003 to December 2020. Main Outcomes and Measures: Adjusted Cox regression analysis was used to assess 5-year mortality risk in STEMI presenting with MINOCA and MINOCA mimickers in comparison with obstructive disease. Results: Among 8560 consecutive patients with STEMI, mean (SD) age was 62 (14) years, 30% were female (2609 participants), and 94% were non-Hispanic White (4358 participants). The cohort included 8151 patients with STEMI due to obstructive disease (95.2%), 120 patients with MINOCA (1.4%), and 289 patients with MINOCA mimickers (3.8%). Patients were followed up for a median (IQR) of 7.1 (3.6-10.7) years. Patients with MINOCA and MINOCA mimickers were less likely to be discharged with cardiac medications compared with obstructive disease. At 5-year follow-up, mortality in STEMI presenting with obstructive disease (1228 participants [16%]) was similar to MINOCA (20 participants [18%]; χ21 = 1.1; log-rank P = .29) and MINOCA mimickers (52 participants [18%]; χ21 = 2.3; log-rank P = .13). In adjusted Cox regression analysis compared with obstructive disease, the 5-year mortality hazard risk was 1.93 times higher in MINOCA (95% CI, 1.06-3.53) and similar in MINOCA mimickers (HR, 1.08; 95% CI, 0.79-1.49). Conclusions and Relevance: In this large multicenter cohort study of consecutive clinical patients with STEMI, presenting with MINOCA was associated with a higher risk of mortality than obstructive disease; the risk of mortality was similar in patients with MINOCA mimickers and obstructive disease. Further investigation is necessary to understand the pathophysiologic mechanisms involved in this high-risk STEMI population.


Asunto(s)
Infarto del Miocardio , Infarto del Miocardio con Elevación del ST , Humanos , Femenino , Persona de Mediana Edad , Masculino , Infarto del Miocardio con Elevación del ST/epidemiología , Infarto del Miocardio/epidemiología , MINOCA , Estudios Retrospectivos , Estudios de Cohortes , Vasos Coronarios , Angiografía Coronaria
14.
J Invasive Cardiol ; 35(7): E341-E354, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37769612

RESUMEN

BACKGROUND: Coronary artery dissection is a feared and potentially life-threatening complication of percutaneous coronary intervention (PCI). METHODS: We examined the clinical, angiographic, and procedural characteristics, and outcomes of coronary dissection at a tertiary care institution. RESULTS: Between 2014 and 2019, unplanned coronary dissection occurred in 141 of 10,278 PCIs (1.4%). Median patient age was 68 (60, 78) years, 68% were men, and 83% had hypertension. The prevalence of diabetes (29%), and prior PCI (37%) was high. Most target vessels were significantly diseased: 48% had moderate/severe tortuosity and 62% had moderate/severe calcification. The most common cause of dissection was guidewire advancement (30%), followed by stenting (22%), balloon angioplasty (20%), and guide-catheter engagement (18%). TIMI flow was 0 in 33% and 1-2 in 41% of cases. Intravascular imaging was used in 17% of the cases. Stenting was used to treat the dissection in 73% of patients. There was no consequence of dissection in 43% of patients. Technical and procedural success was 65% and 55%, respectively. In-hospital major adverse cardiovascular events occurred in 23% of patients: 13 (9%) had an acute myocardial infarction (MI), 3 (2%) had emergency coronary artery bypass graft surgery, and 10 (7%) died. During a mean follow up of 1612 days, 28 (20%) patients died, and the rate of target lesion revascularization was 11.3% (n=16). CONCLUSION: Coronary artery dissection is an infrequent complication of PCI, but is associated with adverse clinical outcomes, such as death and acute MI.


Asunto(s)
Disección Aórtica , Infarto del Miocardio , Intervención Coronaria Percutánea , Masculino , Humanos , Femenino , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Incidencia , Resultado del Tratamiento , Angiografía Coronaria , Infarto del Miocardio/etiología
15.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1333-1339, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37558289

RESUMEN

BACKGROUND: The wearable cardioverter-defibrillator (WCD) prevents sudden cardiac death due to ventricular tachycardia (VT) or ventricular fibrillation (VF) but does not pace for post-shock asystole (PS-A) or bradycardia (PS-B;<50 beats/ min). OBJECTIVES: The purpose of this study was to assess PS-A and PS-B in patients dying out of hospital (OOH) while wearing a WCD. METHODS: The database of the U.S. Food and Drug Administration Manufacturers and User Facility Device Experience (MAUDE) was queried for manufacturers' reports of OOH deaths while patients were wearing a WCD. Excluded were patients who did not receive a shock or were initially shocked for asystole or during resuscitation. RESULTS: From January 2017 to March 2022, 313 patients received an initial WCD shock for VF (n = 150), VT (n = 90), and non-VF/VT rhythms (n = 73). PS-A occurred in 204 patients (65.2%), and PS-B occurred in 111 (35.5%); 85 (41.7%) PS-A patients also had PS-B. Most PS-A patients (n = 185; 90.7%) had an initial shocked rhythm of VF or VT, but 19 patients (9.3%) were initially inappropriately shocked for atrial fibrillation/supraventricular tachycardia (n = 7) and idioventricular (n = 8) or sinus (n = 4) rhythm. PS-A occurred after the first WCD shock in 118 (63.8%) and after the first, second, or third shocks in 159 patients (85.9%). Seven patients had post-shock heart block. Eight patients had permanent pacemakers; 1 became nonfunctional after 1 shock, and 7 showed noncapture and/or asystole after 1 to 4 shocks. CONCLUSIONS: Post-shock asystole appears to be common in patients who die OOH after being shocked by a WCD for VF or VT. PS-A also occurs after inappropriate WCD shocks for non-VF/VT rhythms. Implanted pacemakers may not prevent PS-A after a WCD shock. WCD backup pacing should be explored.


Asunto(s)
Fibrilación Atrial , Paro Cardíaco , Taquicardia Ventricular , Estados Unidos , Humanos , Cardioversión Eléctrica/efectos adversos , Paro Cardíaco/terapia , Fibrilación Ventricular , Desfibriladores , Hospitales
16.
Am J Cardiol ; 202: 111-118, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37429059

RESUMEN

Estimating the likelihood of urgent mechanical circulatory support (MCS) can facilitate procedural planning and clinical decision-making in chronic total occlusion (CTO) percutaneous coronary intervention (PCI). We analyzed 2,784 CTO PCIs performed between 2012 and 2021 at 12 centers. The variable importance was estimated by a bootstrap applying a random forest algorithm to a propensity-matched sample (a ratio of 1:5 matching cases with controls on center). The identified variables were used to predict the risk of urgent MCS. The performance of the risk model was assessed in-sample and on 2,411 out-of-sample procedures that did not require urgent MCS. Urgent MCS was used in 62 (2.2%) of cases. Patients who required urgent MCS were older (70 [63 to 77] vs 66 [58 to 73] years, p = 0.003) compared with those who did not require urgent MCS. Technical (68% vs 87%, p <0.001) and procedural success (40% vs 85%, p <0.001) was lower in the urgent MCS group compared with cases that did not require urgent MCS. The risk model for urgent MCS use included retrograde crossing strategy, left ventricular ejection fraction, and lesion length. The resulting model demonstrated good calibration and discriminatory capacity with the area under the curve (95% confidence interval) of 0.79 (0.73 to 0.86) and specificity and sensitivity of 86% and 52%, respectively. In the out-of-sample set, the specificity of the model was 87%. The Prospective Global Registry for the Study of Chronic Total Occlusion Intervention CTO MCS score can help estimate the risk of urgent MCS use during CTO PCI.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos , Volumen Sistólico , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/cirugía , Enfermedad Crónica , Función Ventricular Izquierda , Sistema de Registros , Angiografía Coronaria/métodos
17.
J Soc Cardiovasc Angiogr Interv ; : 100970, 2023 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-37363317

RESUMEN

Background: Important health care differences exist between the United States (US) and Canada, which may have been exacerbated during the pandemic. We compared clinical characteristics, treatment strategies, and clinical outcomes of patients with ST-segment elevation myocardial infarction (STEMI) and COVID-19 (STEMI-COVID) treated in the US and Canada. Methods: The North American COVID-19 Myocardial Infarction registry is a prospective, investigator-initiated study enrolling patients with STEMI with confirmed or suspected COVID-19 in the US and Canada. The primary end point was in-hospital mortality. Additionally, we explored associations between vaccination and clinical outcomes. Results: Of 853 patients with STEMI-COVID, 112 (13%) were enrolled in Canada, and compared with the US, patients in Canada were more likely to present with chest pain and less likely to have a history of heart failure, stroke/transient ischemic attack, pulmonary infiltrates or renal failure. In both countries, the primary percutaneous coronary intervention was the dominant reperfusion strategy, with no difference in door-to-balloon times; fibrinolysis was used less frequently in the US than in Canada. The adjusted in-hospital mortality was not different between the 2 countries (relative risk [RR], 1.0; 95% CI, 0.46-2.72; P = 1.0). However, the risk of in-hospital mortality was significantly higher in unvaccinated compared with vaccinated patients with STEMI-COVID (RR, 4.7; 95% CI, 1.7-11.53; P = .015). Conclusions: Notable differences in morbidities and reperfusion strategies were evident between patients with STEMI-COVID in the US compared with Canada. No differences were noted for in-hospital mortality. Vaccination, regardless of region, appeared to associate with a lower risk of in-hospital mortality strongly.

18.
Heart Rhythm ; 20(7): 970-975, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37211148

RESUMEN

BACKGROUND: The LifeVest® wearable cardioverter-defibrillator (WCD) prevents sudden cardiac death in at-risk patients who are not candidates for an implantable defibrillator. The safety and efficacy of the WCD may be impacted by inappropriate shocks (IAS). OBJECTIVE: The purpose of this study was to assess the causes and clinical consequences of WCD IAS in survivors of IAS events. METHODS: The Food and Drug Administration's Manufacturers and User Facility Device Experience database was searched for IAS adverse events (AE) that were reported during 2021 and 2022. RESULTS: A total of 2568 IAS-AE were found (average number of IAS per event: 1.5 ± 1.9; range 1-48). IAS were caused by tachycardias (1255 [48.9%]), motion artifacts (840 [32.7%]), and oversensing (OS) of low-level electrical signals (473 [18.4%]) (P <.001). Tachycardias included atrial fibrillation (AF) (828 [32.2%]), supraventricular tachycardia (SVT) (333 [13.0%]), and nonsustained ventricular tachycardia/fibrillation (NSVT/VF) (87 [3.4%]). Activities responsible for motion-induced IAS included riding a motorcycle, lawnmower, or tractor (n = 128). In 19 patients, IAS induced sustained ventricular tachycardia or ventricular fibrillation that subsequently were terminated by appropriate WCD shocks. Thirty patients fell and suffered physical injuries. Conscious patients (n = 1905) did not use the response buttons to abort shocks (47.9%) or used them improperly (20.2%). IAS resulted in 1190 emergency room visits or hospitalizations, and 17.3% of patients (421/2440) discontinued the WCD after experiencing IAS, especially multiple IAS. CONCLUSIONS: The LifeVest WCD may deliver IAS caused by AF, SVT, NSVT/VF, motion artifacts, and oversensing of electrical signals. These shocks may be arrhythmogenic, result in injuries, precipitate WCD discontinuation, and consume medical resources. Improved WCD sensing, rhythm discrimination, and methods to abort IAS are needed.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Cardioversión Eléctrica/efectos adversos , Desfibriladores Implantables/efectos adversos , Fibrilación Ventricular , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicaciones , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Fibrilación Atrial/complicaciones , Taquicardia Supraventricular/complicaciones
19.
J Endovasc Ther ; : 15266028231172375, 2023 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-37154503

RESUMEN

PURPOSE: To evaluate the effect of iliac tortuosity on procedural metrics and outcomes of patients with complex aortic aneurysms (cAAs) undergoing repair with fenestrated/branched endografts (f/b-EVAR [endovascular aortic aneurysm repair]). MATERIAL AND METHODS: The study is a single-center, retrospective review of a prospectively maintained database of patients undergoing aneurysm repair using f/b-EVAR between the years 2013 and 2020 at our institution. Included patients had at least 1 preoperative computed tomography angiography (CTA) available for analysis. Iliac artery tortuosity index (TI) was calculated using centerline of flow imaging from a 3-dimensional work station based on the formula: (centerline iliac artery length / straight-line iliac artery length). The associations between iliac artery tortuosity and procedural metrics, including total operative time, fluoroscopy time, radiation dose, contrast volume, and estimated blood loss (EBL), were evaluated. RESULTS: During this period, 219 patients with cAAs underwent f/b-EVAR at our institution. Ninety-one patients (74% men; mean age = 75.2±7.7 years) met criteria for inclusion into the study. In this group, there were 72 (79%) juxtarenal or paravisceral aneurysms and 18 (20%) thoracoabdominal aortic aneurysms and 5 patients (5.4%) with failed previous EVAR. The average aneurysm diameter was 60.1±0.74 mm. Overall, 270 vessels were targeted, and 267 (99%) were successfully incorporated, including 25 celiac arteries, 67 superior mesenteric arteries, and 175 renal arteries. The mean total operative time was 236±83 minutes, fluoroscopy time was 87±39 minutes, contrast volume was 81±47 mL, radiation dose 3246±2207 mGy, and EBL was 290±409 mL. The average left and right TIs for all patients were 1.5±0.3 and 1.4±0.3, respectively. On multivariable analysis, the interval estimates suggest positive association between TI and procedural metrics to a certain degree. CONCLUSIONS: In the current series, we found no definitive association between iliac artery TI and procedural metrics, including operative time, contrast used, EBL, fluoroscopy time, and dose in patients undergoing cAA repair using f/b-EVAR. However, there was a trend toward association between TI and all these metrics on multivariable analysis. This potential association needs to be evaluated in a larger series. CLINICAL IMPACT: Iliac artery tortuosity should not exclude patients with complex aortic aneurysms from being offered fenestrated or branched stent graft repair. However, special considerations should be taken to mitigate the impact of access tortuosity on alignment of fenestrations with target vessels, including use of extra stiff wires, through and through access and delivering the fenestrated/branched device into another (larger) sheath such as a Gore DrySeal in patients with arteries large enough to accommodate such sheaths.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA