RESUMEN
OBJECTIVES: To determine the prevalence, trends, and potential nosocomial transmission events of the hidden reservoir of rectal carriage of extended-spectrum beta-lactamase-producing Enterobacterales (ESBL-E). METHODS: From 2013 to 2022, yearly point prevalence surveys were conducted in a large Dutch teaching hospital. On the day of the survey, all admitted patients were screened for ESBL-E rectal carriage using peri-anal swabs and a consistent and sensitive selective culturing method. All Enterobacterales phenotypically suspected of ESBL production were analysed using whole genome sequencing for ESBL gene detection and clonal relatedness analysis. RESULTS: On average, the ESBL-E prevalence was 4.6% (188/4,119 patients), ranging from 2.1 to 6.6% per year. The ESBL-prevalence decreased on average 5.5% per year. After time trend correction, the prevalence in 2016 and 2020 was lower compared to the other year. Among the ESBL-E, Escherichia coli (80%) and CTX-M genes (85%) predominated. Potential nosocomial transmission events could be found in 5.9% (11/188) of the ESBL-E carriers. CONCLUSIONS: The ESBL-E rectal carriage prevalence among hospitalized patients was 4.6% with a downward trend from 2013 to 2022. The decrease in ESBL-E prevalence in 2020 could have been due to the COVID-19 pandemic and subsequent countrywide measures as no nosocomial transmission events were detected in 2020. However, the persistently low ESBL-E prevalences in 2021 and 2022 suggest that the decline in ESBL-E prevalence goes beyond the COVID-19 pandemic, indicating that overall ESBL-E carriage rates are declining over time. Continuous monitoring of ESBL-E prevalence and transmission rates can aid infection control policy to keep antibiotic resistance rates in hospitals low.
Asunto(s)
Portador Sano , Infección Hospitalaria , Infecciones por Enterobacteriaceae , Enterobacteriaceae , Hospitales de Enseñanza , Secuenciación Completa del Genoma , beta-Lactamasas , Humanos , beta-Lactamasas/genética , Países Bajos/epidemiología , Prevalencia , Infecciones por Enterobacteriaceae/epidemiología , Infecciones por Enterobacteriaceae/microbiología , Infecciones por Enterobacteriaceae/transmisión , Portador Sano/epidemiología , Portador Sano/microbiología , Masculino , Femenino , Enterobacteriaceae/genética , Enterobacteriaceae/efectos de los fármacos , Enterobacteriaceae/enzimología , Anciano , Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , Persona de Mediana Edad , Adulto , Recto/microbiología , Anciano de 80 o más Años , Adulto JovenRESUMEN
BACKGROUND: The current reference standard to diagnose a SARS-CoV-2 infection is real-time reverse transcriptase polymerase chain reaction (RT-PCR). This test poses substantial challenges for large-scale community testing, especially with respect to the long turnaround times. SARS-CoV-2 antigen tests are an alternative, but typically use a lateral flow assay format rendering them less suitable for analysis of large numbers of samples. METHODS: We conducted an evaluation of the Diasorin SARS-CoV-2 antigen detection assay (DAA) compared to real-time RT-PCR (Abbott). The study was performed on 248 (74 qRT-PCR positive, 174 qRT-PCR negative) clinical combined oro-nasopharyngeal samples of individuals with COVID-19-like symptoms obtained at a Municipal Health Service test centre. In addition, we evaluated the analytical performance of DAA with a 10-fold dilution series of SARS-CoV-2 containing culture supernatant and compared it with the lateral flow assay SARS-CoV-2 Roche/SD Biosensor Rapid Antigen test (RRA). RESULTS: The DAA had an overall specificity of 100% (95%CI 97.9%-100%) and sensitivity of 73% (95%CI 61.3%-82.7%) for the clinical samples. Sensitivity was 86% (CI95% 74.6%-93.3%) for samples with Ct-value below 30. Both the DAA and RRA detected SARS-CoV-2 up to a dilution containing 5.2 × 102 fifty-percent-tissue-culture-infective-dose (TCID50)/ml. DISCUSSION: The DAA performed adequately for clinical samples with a Ct-value below 30. Test performance may be further optimised by lowering the relative light unit (RLU) threshold for positivity assuming the in this study used pre-analytical protocol . The test has potential for use as a diagnostic assay for symptomatic community-dwelling individuals early after disease onset in the context of disease control.
Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Nasofaringe , Sensibilidad y EspecificidadRESUMEN
BACKGROUND: Vancomycin-resistant enterococci (VRE) may cause nosocomial outbreaks. This article describes all VRE carriers that were identified in 2018 at Elisabeth-Tweesteden Hospital, Tilburg, The Netherlands. AIM: To investigate the genetic relatedness of VRE isolates and the possibility of a common environmental reservoir using environmental sampling and whole-genome sequencing (WGS). METHODS: Infection control measures consisted of contact isolation, contact surveys, point prevalence screening, environmental sampling, cleaning and disinfection. VRE isolates were sequenced using a MiSeq sequencer (Illumina, San Diego, CA, USA), and assembled using SPAdes v.3.10.1. A minimal spanning tree and a neighbour joining tree based on allelic diversity of core-genome multi-locus sequence typing and accessory genes were created using Ridom SeqSphere+ software (Ridom GmbH, Münster, Germany). FINDINGS: Over a 1-year period, 19 VRE carriers were identified; of these, 17 were part of two outbreaks. Before environmental cleaning and disinfection, 55 (14%) environmental samples were VRE-positive. Fifty-one isolates (23 patient samples and 28 environmental samples) were available for WGS analysis. Forty-four isolates were assigned to ST117-vanB, five were assigned to ST17-vanB, and two were assigned to ST80-vanB. Isolates from Outbreak 1 (N=22) and Outbreak 2 (N=22) belonged to ST117-vanB; however, WGS showed a different cluster type with 257 allelic differences. CONCLUSION: WGS of two outbreak strains provided discriminatory information regarding genetic relatedness, and rejected the hypothesis of a common environmental reservoir. A high degree of environmental contamination was associated with higher VRE transmission. Quantification of environmental contamination may reflect the potential for VRE transmission and could therefore support the infection control measures.