Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
3.
Radiat Environ Biophys ; 61(4): 485-504, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36001144

RESUMEN

Partial body exposure and inhomogeneous dose delivery are features of the majority of medical and occupational exposure situations. However, mounting evidence indicates that the effects of partial body exposure are not limited to the irradiated area but also have systemic effects that are propagated outside the irradiated field. It was the aim of the "Partial body exposure" session within the MELODI workshop 2020 to discuss recent developments and insights into this field by covering clinical, epidemiological, dosimetric as well as mechanistic aspects. Especially the impact of out-of-field effects on dysfunctions of immune cells, cardiovascular diseases and effects on the brain were debated. The presentations at the workshop acknowledged the relevance of out-of-field effects as components of the cellular and organismal radiation response. Furthermore, their importance for the understanding of radiation-induced pathologies, for the discovery of early disease biomarkers and for the identification of high-risk organs after inhomogeneous exposure was emphasized. With the rapid advancement of clinical treatment modalities, including new dose rates and distributions a better understanding of individual health risk is urgently needed. To achieve this, a deeper mechanistic understanding of out-of-field effects in close connection to improved modelling was suggested as priorities for future research. This will support the amelioration of risk models and the personalization of risk assessments for cancer and non-cancer effects after partial body irradiation.


Asunto(s)
Enfermedades Cardiovasculares , Radiometría , Humanos , Medición de Riesgo
4.
Radiat Prot Dosimetry ; 194(1): 42-56, 2021 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-33989429

RESUMEN

Since 2012, the European Radiation Dosimetry Group (EURADOS) has developed its Strategic Research Agenda (SRA), which contributes to the identification of future research needs in radiation dosimetry in Europe. Continued scientific developments in this field necessitate regular updates and, consequently, this paper summarises the latest revision of the SRA, with input regarding the state of the art and vision for the future contributed by EURADOS Working Groups and through a stakeholder workshop. Five visions define key issues in dosimetry research that are considered important over at least the next decade. They include scientific objectives and developments in (i) updated fundamental dose concepts and quantities, (ii) improved radiation risk estimates deduced from epidemiological cohorts, (iii) efficient dose assessment for radiological emergencies, (iv) integrated personalised dosimetry in medical applications and (v) improved radiation protection of workers and the public. This SRA will be used as a guideline for future activities of EURADOS Working Groups but can also be used as guidance for research in radiation dosimetry by the wider community. It will also be used as input for a general European research roadmap for radiation protection, following similar previous contributions to the European Joint Programme for the Integration of Radiation Protection Research, under the Horizon 2020 programme (CONCERT). The full version of the SRA is available as a EURADOS report (www.eurados.org).


Asunto(s)
Monitoreo de Radiación , Protección Radiológica , Europa (Continente) , Humanos , Dosis de Radiación , Radiación Ionizante , Radiometría
5.
Phys Med ; 82: 134-143, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33611050

RESUMEN

The lack of mailed dosimetry audits of proton therapy centres in Europe has encouraged researchers of EURADOS Working Group 9 (WG9) to compare response of several existing passive detector systems in therapeutic pencil beam scanning. Alanine Electron Paramagnetic Resonance dosimetry systems from 3 different institutes (ISS, Italy; UH, Belgium and IFJ PAN, Poland), natLiF:Mg, Ti (MTS-N) and natLiF:Mg, Cu, P (MCP-N) thermoluminescent dosimeters (TLDs), GD-352M radiophotoluminescent glass dosimeters (RPLGDs) and Al2O3:C optically stimulated dosimeters (OSLDs) were evaluate. Dosimeter repeatability, batch reproducibility and response in therapeutic Pencil Beam Scanning were verified for implementation as mail auditing system. Alanine detectors demonstrated the lowest linear energy transfer (LET) dependence with an agreement between measured and treatment planning system (TPS) dose below 1%. The OSLDs measured on average a 6.3% lower dose compared to TPS calculation, with no significant difference between varying modulations and ranges. Both GD-352M and MCP-N measured a lower dose than the TPS and luminescent response was dependent on the LET of the therapeutic proton beam. Thermoluminescent response of MTS-N was also found to be dependent on the LET and a higher dose than TPS was measured with the most pronounced increase of 11%. As alanine detectors are characterized by the lowest energy dependence for different parameters of therapeutic pencil beam scanning they are suitable candidates for mail auditing in proton therapy. The response of luminescence detector systems have shown promises even though more careful calibration and corrections are needed for its implementation as part of a mailed dosimetry audit system.


Asunto(s)
Terapia de Protones , Bélgica , Europa (Continente) , Italia , Polonia , Protones , Dosímetros de Radiación , Radiometría , Reproducibilidad de los Resultados , Dosimetría Termoluminiscente
6.
Phys Med Biol ; 66(3): 035012, 2021 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-33202399

RESUMEN

The lowest possible energy of proton scanning beam in cyclotron proton therapy facilities is typically between 60 and 100 MeV. Treatment of superficial lesions requires a pre-absorber to deliver doses to shallower volumes. In most of the cases a range shifter (RS) is used, but as an alternative solution, a patient-specific 3D printed proton beam compensator (BC) can be applied. A BC enables further reduction of the air gap and consequently reduction of beam scattering. Such pre-absorbers are additional sources of secondary radiation. The aim of this work was the comparison of RS and BC with respect to out-of-field doses for a simulated treatment of superficial paediatric brain tumours. EURADOS WG9 performed comparative measurements of scattered radiation in the Proteus C-235 IBA facility (Cyclotron Centre Bronowice at the Institute of Nuclear Physics, CCB IFJ PAN, Kraków, Poland) using two anthropomorphic phantoms-5 and 10 yr old-for a superficial target in the brain. Both active detectors located inside the therapy room, and passive detectors placed inside the phantoms were used. Measurements were supplemented by Monte Carlo simulation of the radiation transport. For the applied 3D printed pre-absorbers, out-of-field doses from both secondary photons and neutrons were lower than for RS. Measurements with active environmental dosimeters at five positions inside the therapy room indicated that the RS/BC ratio of the out-of-field dose was also higher than one, with a maximum of 1.7. Photon dose inside phantoms leads to higher out-of-field doses for RS than BC to almost all organs with the highest RS/BC ratio 12.5 and 13.2 for breasts for 5 and 10 yr old phantoms, respectively. For organs closest to the isocentre such as the thyroid, neutron doses were lower for BC than RS due to neutrons moderation in the target volume, but for more distant organs like bladder-conversely-lower doses for RS than BC were observed. The use of 3D printed BC as the pre-absorber placed in the near vicinity of patient in the treatment of superficial tumours does not result in the increase of secondary radiation compared to the treatment with RS, placed far from the patient.


Asunto(s)
Impresión Tridimensional , Terapia de Protones/instrumentación , Dosis de Radiación , Neoplasias Encefálicas/radioterapia , Niño , Simulación por Computador , Humanos , Método de Montecarlo , Neutrones , Fantasmas de Imagen , Dosificación Radioterapéutica
7.
Phys Med Biol ; 65(11): 115003, 2020 06 05.
Artículo en Inglés | MEDLINE | ID: mdl-32235080

RESUMEN

The ion recombination is examined in parallel-plate ionization chambers in scanning proton beams at the Danish Centre for Particle Therapy and the Skandion Clinic. The recombination correction factor k s is investigated for clinically relevant energies between 70 MeV and 244 MeV for dose rates below 400 Gy min-1 in air. The Boutillon formalism is used to separate the initial and general recombination. The general recombination is compared to predictions from the numerical recombination code IonTracks and the initial recombination to the Jaffé theory. k s is furthermore calculated with the two-voltage method (TVM) and extrapolation approaches, in particular the recently proposed three-voltage (3VL) method. The TVM is in agreement with the Boutillon method and IonTracks for dose rates above 100 Gy min-1. However, the TVM calculated k s is closer related to the Jaffé theory for initial recombination for lower dose rate, indicating a limited application in scanning light ion beams. The 3VL is in turn found to generally be in agreement with Boutillon's method. The recombination is mapped as a function of the dose rate and proton energy at the two centres using the Boutillon formalism: the initial recombination parameter was found to be A = (0.10 ± 0.01) V at DCPT and A = (0.22 ± 0.13) V at Skandion, which is in better agreement with the Jaffé theory for initial recombination than previously reported values. The general recombination parameter was estimated to [Formula: see text] and [Formula: see text]. Furthermore, the numerical algorithm IonTracks is demonstrated to correctly predict the initial recombination at low dose rates and the general recombination at high dose rates.


Asunto(s)
Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Radiometría/métodos , Cintigrafía/métodos
8.
J Radiol Prot ; 39(4): R37-R50, 2019 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-31307030

RESUMEN

This paper provides a summary of the Education and Training (E&T) activities that have been developed and organised by the European Radiation Dosimetry Group (EURADOS) in recent years and in the case of Training Courses over the last decade. These E&T actions include short duration Training Courses on well-established topics organised within the activity of EURADOS Working Groups (WGs), or one-day events integrated in the EURADOS Annual Meeting (workshops, winter schools, the intercomparison participants' sessions and the learning network, among others). Moreover, EURADOS has recently established a Young Scientist Grant and a Young Scientist Award. The Grant supports young scientists by encouraging them to perform research projects at other laboratories of the EURADOS network. The Award is given in recognition of excellent work developed within the WGs' work programme. Additionally, EURADOS supports the dissemination of knowledge in radiation dosimetry by promoting and endorsing conferences such as the individual monitoring (IM) series, the neutron and ion dosimetry symposia (NEUDOS) and contributions to E&T sessions at specific events.

9.
Phys Med Biol ; 63(8): 085017, 2018 04 19.
Artículo en Inglés | MEDLINE | ID: mdl-29509148

RESUMEN

Systematic 3D mapping of out-of-field doses induced by a therapeutic proton pencil scanning beam in a 300 × 300 × 600 mm3 water phantom was performed using a set of thermoluminescence detectors (TLDs): MTS-7 (7LiF:Mg,Ti), MTS-6 (6LiF:Mg,Ti), MTS-N (natLiF:Mg,Ti) and TLD-700 (7LiF:Mg,Ti), radiophotoluminescent (RPL) detectors GD-352M and GD-302M, and polyallyldiglycol carbonate (PADC)-based (C12H18O7) track-etched detectors. Neutron and gamma-ray doses, as well as linear energy transfer distributions, were experimentally determined at 200 points within the phantom. In parallel, the Geant4 Monte Carlo code was applied to calculate neutron and gamma radiation spectra at the position of each detector. For the cubic proton target volume of 100 × 100 × 100 mm3 (spread out Bragg peak with a modulation of 100 mm) the scattered photon doses along the main axis of the phantom perpendicular to the primary beam were approximately 0.5 mGy Gy-1 at a distance of 100 mm and 0.02 mGy Gy-1 at 300 mm from the center of the target. For the neutrons, the corresponding values of dose equivalent were found to be ~0.7 and ~0.06 mSv Gy-1, respectively. The measured neutron doses were comparable with the out-of-field neutron doses from a similar experiment with 20 MV x-rays, whereas photon doses for the scanning proton beam were up to three orders of magnitude lower.


Asunto(s)
Imagenología Tridimensional/métodos , Fantasmas de Imagen , Terapia de Protones/métodos , Radiometría/métodos , Dosimetría Termoluminiscente/métodos , Rayos gamma , Humanos , Método de Montecarlo , Neutrones , Fotones , Protones , Radiactividad , Cintigrafía , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Dosimetría Termoluminiscente/instrumentación , Agua
10.
Radiat Prot Dosimetry ; 180(1-4): 324-328, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29351653

RESUMEN

Gafchromic EBT3 films are applied in proton radiotherapy for 2D dose mapping because they demonstrate spatial resolution well below 1 mm. However, the film response must be corrected in order to reach the accuracy of dose measurements required for the clinical use. The in-house developed AnalyseGafchromic software allows to analyze and correct the measured response using triple channel dose calibration, statistical scan-to-scan fluctuations as well as experimentally determined dose and LET dependence. Finally, the optimized protocol for evaluation of response of Gafchromic EBT3 films was applied to determine 30 × 40 cm2 dose profiles of the scanning therapy unit at the Cyclotron Centre Bronowice, CCB in Krakow, Poland.


Asunto(s)
Dosimetría por Película/instrumentación , Dosimetría por Película/métodos , Transferencia Lineal de Energía , Terapia de Protones , Radioterapia de Intensidad Modulada/métodos , Calibración , Relación Dosis-Respuesta en la Radiación , Humanos , Dosis de Radiación , Radioterapia de Intensidad Modulada/instrumentación
11.
Radiat Prot Dosimetry ; 180(1-4): 334-337, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29040734

RESUMEN

For commissioning of a proton therapy unit depth dose distributions must be determined and introduced into the Treatment Planning System. In pencil beam scanning (PBS) technique, integral depth dose (IDD) acquisition should be performed with detector large enough to ensure entire beam laterally broadened by scattered and secondary contributions. The purpose of this article is to quantify, using measurements and Monte Carlo transport calculations, the ionization chamber's (IC) geometrical efficiency versus the chamber radius and proton beam energy. The geometrical efficiency of 0.99 was determined for energies up to 160 and 190 MeV for 4.08 and 6 cm radius IC. Much lower geometrical efficiency was obtained for the energy of 226.08 MeV and results in charge loss of 5.8 and 3.6%, respectively. Relative IDD differences between IC 4.08 and 6 cm in radius increase with proton energy and reach 2.4% at the mid-range depth for 226.08 MeV.


Asunto(s)
Terapia de Protones/instrumentación , Terapia de Protones/métodos , Radiometría/instrumentación , Radiometría/métodos , Simulación por Computador , Humanos , Método de Montecarlo , Dosificación Radioterapéutica
12.
Radiat Prot Dosimetry ; 180(1-4): 256-260, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29165619

RESUMEN

Proton beam therapy has advantages in comparison to conventional photon radiotherapy due to the physical properties of proton beams (e.g. sharp distal fall off, adjustable range and modulation). In proton therapy, there is the possibility of sparing healthy tissue close to the target volume. This is especially important when tumours are located next to critical organs and while treating cancer in paediatric patients. On the other hand, the interactions of protons with matter result in the production of secondary radiation, mostly neutrons and gamma radiation, which deposit their energy at a distance from the target. The aim of this study was to compare the response of different passive dosimetry systems in mixed radiation field induced by proton pencil beam inside anthropomorphic phantoms representing 5 and 10 years old children. Doses were measured in different organs with thermoluminescent (MTS-7, MTS-6 and MCP-N), radiophotoluminescent (GD-352 M and GD-302M), bubble and poly-allyl-diglycol carbonate (PADC) track detectors. Results show that RPL detectors are the less sensitive for neutrons than LiF TLDs and can be applied for in-phantom dosimetry of gamma component. Neutron doses determined using track detectors, bubble detectors and pairs of MTS-7/MTS-6 are consistent within the uncertainty range. This is the first study dealing with measurements on child anthropomorphic phantoms irradiated by a pencil scanning beam technique.


Asunto(s)
Fantasmas de Imagen , Terapia de Protones/instrumentación , Protones , Radiometría/instrumentación , Dosimetría Termoluminiscente/instrumentación , Algoritmos , Antropometría , Niño , Preescolar , Diseño de Equipo , Rayos gamma/uso terapéutico , Humanos , Método de Montecarlo , Neutrones , Dosis de Radiación , Radiación Ionizante , Cintigrafía , Dosificación Radioterapéutica
13.
Phys Med ; 34: 80-84, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28131732

RESUMEN

PURPOSE: To measure the environmental doses from stray neutrons in the vicinity of a solid slab phantom as a function of beam energy, field size and modulation width, using the proton pencil beam scanning (PBS) technique. METHOD: Measurements were carried out using two extended range WENDI-II rem-counters and three tissue equivalent proportional counters. Detectors were suitably placed at different distances around the RW3 slab phantom. Beam irradiation parameters were varied to cover the clinical ranges of proton beam energies (100-220MeV), field sizes ((2×2)-(20×20)cm2) and modulation widths (0-15cm). RESULTS: For pristine proton peak irradiations, large variations of neutron H∗(10)/D were observed with changes in beam energy and field size, while these were less dependent on modulation widths. H∗(10)/D for pristine proton pencil beams varied between 0.04µSvGy-1 at beam energy 100MeV and a (2×2)cm2 field at 2.25m distance and 90° angle with respect to the beam axis, and 72.3µSvGy-1 at beam energy 200MeV and a (20×20) cm2 field at 1m distance along the beam axis. CONCLUSIONS: The obtained results will be useful in benchmarking Monte Carlo calculations of proton radiotherapy in PBS mode and in estimating the exposure to stray radiation of the patient. Such estimates may be facilitated by the obtained best-fitted simple analytical formulae relating the stray neutron doses at points of interest with beam irradiation parameters.


Asunto(s)
Neutrones/uso terapéutico , Terapia de Protones , Dosis de Radiación , Dispersión de Radiación , Método de Montecarlo , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica
14.
Med Phys ; 42(5): 2572-84, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25979049

RESUMEN

PURPOSE: To characterize stray radiation around the target volume in scanning proton therapy and study the performance of active neutron monitors. METHODS: Working Group 9 of the European Radiation Dosimetry Group (EURADOS WG9-Radiation protection in medicine) carried out a large measurement campaign at the Trento Centro di Protonterapia (Trento, Italy) in order to determine the neutron spectra near the patient using two extended-range Bonner sphere spectrometry (BSS) systems. In addition, the work focused on acknowledging the performance of different commercial active dosimetry systems when measuring neutron ambient dose equivalents, H(∗)(10), at several positions inside (8 positions) and outside (3 positions) the treatment room. Detectors included three TEPCs--tissue equivalent proportional counters (Hawk type from Far West Technology, Inc.) and six rem-counters (WENDI-II, LB 6411, RadEye™ NL, a regular and an extended-range NM2B). Meanwhile, the photon component of stray radiation was deduced from the low-lineal energy transfer part of TEPC spectra or measured using a Thermo Scientific™ FH-40G survey meter. Experiments involved a water tank phantom (60 × 30 × 30 cm(3)) representing the patient that was uniformly irradiated using a 3 mm spot diameter proton pencil beam with 10 cm modulation width, 19.95 cm distal beam range, and 10 × 10 cm(2) field size. RESULTS: Neutron spectrometry around the target volume showed two main components at the thermal and fast energy ranges. The study also revealed the large dependence of the energy distribution of neutrons, and consequently of out-of-field doses, on the primary beam direction (directional emission of intranuclear cascade neutrons) and energy (spectral composition of secondary neutrons). In addition, neutron mapping within the facility was conducted and showed the highest H(∗)(10) value of ∼ 51 µSv Gy(-1); this was measured at 1.15 m along the beam axis. H(∗)(10) values significantly decreased with distance and angular position with respect to beam axis falling below 2 nSv Gy(-1) at the entrance of the maze, at the door outside the room and below detection limit in the gantry control room, and at an adjacent room (<0.1 nSv Gy(-1)). Finally, the agreement on H(∗)(10) values between all detectors showed a direct dependence on neutron spectra at the measurement position. While conventional rem-counters (LB 6411, RadEye™ NL, NM2-458) underestimated the H(∗)(10) by up to a factor of 4, Hawk TEPCs and the WENDI-II range-extended detector were found to have good performance (within 20%) even at the highest neutron fluence and energy range. Meanwhile, secondary photon dose equivalents were found to be up to five times lower than neutrons; remaining nonetheless of concern to the patient. CONCLUSIONS: Extended-range BSS, TEPCs, and the WENDI-II enable accurate measurements of stray neutrons while other rem-counters are not appropriate considering the high-energy range of neutrons involved in proton therapy.


Asunto(s)
Terapia de Protones/métodos , Radiometría/métodos , Europa (Continente) , Neutrones , Fantasmas de Imagen , Fotones , Terapia de Protones/instrumentación , Protones , Dosis de Radiación , Radiometría/instrumentación , Análisis Espectral/instrumentación , Análisis Espectral/métodos , Agua
15.
Radiat Prot Dosimetry ; 159(1-4): 137-40, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24876341

RESUMEN

A new quality assurance and quality control method for proton eye radiotherapy based on electron paramagnetic resonance (EPR)/alanine dosimetry has been developed. It is based on Spread-Out Bragg Peak entrance dose measurement with alanine detectors. The entrance dose is well correlated with the dose at the facility isocenter, where, during the therapeutic irradiation, the tumour is placed. The unique alanine detector features namely keeping the dose record in a form of stable radiation-induced free radicals trapped in the material structure, and the non-destructive read-out makes this type of detector a good candidate for additional documentation of the patient's exposure over the therapy course.


Asunto(s)
Alanina/química , Espectroscopía de Resonancia por Spin del Electrón/métodos , Oftalmopatías/radioterapia , Terapia de Protones , Garantía de la Calidad de Atención de Salud , Radiometría/métodos , Humanos , Dosificación Radioterapéutica
16.
Ann Behav Med ; 23(4): 253-62, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11761342

RESUMEN

Participant-rated and compendium-coded intensity of daily physical activities were compared in 148 African American, 144 Native American, 51 non-Hispanic White women ages 40 to 91 years who completed 4 days of activity records. For compendium-coded intensity, reported activities were classified as light (< 3 metabolic equivalents [METS]), moderate (3-6 METS), or vigorous (> 6 METS) using the Compendium of Physical Activities (1), whereas these categories were self-assigned for participant-rated intensity. Minutes per day (min/d) spent in activities at each intensity level were computed. Relative to compendium-coded min/d, participants reported significantly greater time spent in light (+10 min/d; p < .01) and vigorous (+17 min/d; p < .001) activities, and less time spent in moderate activities (-27 min/d; p <.001). Similarly, compendium-coded estimates yielded higher rates ofparticipants meeting Centersfor Disease Control and Prevention-American College of Sports Medicine and Surgeon General recommendations than participant-rated estimates (11-18% differences) but substantially lower rates meeting American College of Sports Medicine vigorous recommendations (22% difference). Further, 247 greater kilocalories per day were estimated based on compendium-coded intensity. Kilocalories per day estimates based on compendium codings were more highly associated with pedometer counts than those based on participant ratings (p < .05). Studypatterns were generally seen across all sample subgroups. Discrepancies between participant and compendium estimates are likely to be most meaningful in studies estimating energy expenditure as it relates to health outcomes and in studies estimating vigorous activities.


Asunto(s)
Negro o Afroamericano/estadística & datos numéricos , Hispánicos o Latinos/estadística & datos numéricos , Indígenas Norteamericanos/estadística & datos numéricos , Actividades Cotidianas , Análisis de Varianza , Comparación Transcultural , Metabolismo Energético , Ejercicio Físico , Femenino , Conductas Relacionadas con la Salud/etnología , Humanos , Persona de Mediana Edad
17.
Diabetes Care ; 23(4): 449-54, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10857933

RESUMEN

OBJECTIVE: The purpose of this study was to determine the association between moderate-intensity physical activity (PA) and fasting insulin levels among African-American (n = 47), Native American (n = 46), and Caucasian women (n = 49), aged 40-83 years, enrolled in the Cross-Cultural Activity Participation Study. Associations by race/ethnicity, levels of central obesity, and cardiorespiratory fitness were also examined. RESEARCH DESIGN AND METHODS: Physical activity scores were obtained from detailed PA records that included all PA performed during two consecutive 4-day periods scheduled 1 month apart. Using MET intensity (the associated metabolic rate for a specific activity divided by a standard resting metabolic rate), PA was expressed as MET-min (the product of the minutes for each activity times the MET intensity level) per day of energy expended in moderate (3-6 METs) and moderate/vigorous (> or = 3 METs) PA. Fasting insulin levels were determined by radioimmunoassay. Data were analyzed by multiple linear regression analysis. RESULTS: After adjusting for race/ethnicity, age, educational attainment, and site, an increase of 30 min of moderate-intensity PA was associated with a 6.6% lower fasting insulin level (P < 0.05). The association was similar among races/ethnicities, centrally lean and centrally obese women, and women with low and high cardiorespiratory fitness levels. CONCLUSIONS: These findings lend support to the 1995 Centers for Disease Control and Prevention and American College of Sports Medicine recommendations for an accumulation of 30 min/day in moderate-intensity PA. They also contribute to the growing literature suggesting that moderate amounts of PA have a significant role in reducing the burden of hyperinsulinemia and diabetes among ethnic populations at highest risk for these conditions.


Asunto(s)
Negro o Afroamericano , Comparación Transcultural , Metabolismo Energético , Estado de Salud , Indígenas Norteamericanos , Insulina/sangre , Población Blanca , Glucemia/metabolismo , Presión Sanguínea , Ejercicio Físico , Ayuno , Femenino , Humanos , Persona de Mediana Edad , Análisis de Regresión , Salud de la Mujer
18.
Med Sci Sports Exerc ; 32(2): 531-9, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10694143

RESUMEN

PURPOSE: This study tested the predictive accuracy of the Jackson et al. skinfold (SKF) equations (sigma7SKF and sigma3SKF), a multi-site near-infrared interactance (NIR) prediction equation, and the Futrex-5000 NMR equation in estimating body composition of American Indian women (N = 151, aged 18-60 yr). METHODS: Criterion body density (Db) was obtained from hydrodensitometry at residual lung volume. RESULTS: Sigma7SKF significantly underestimated Db (P < 0.05). Sigma3SKF and Heyward's NIR equations significantly overestimated Db (P < 0.05). The Futrex-5000 NIR equation significantly underestimated percent of body fat (%BF) (P < 0.05). Prediction errors for SKF and multi-site NIR exceeded 0.0080 g x cc(-1). The SEE for Futrex-5000 was 5.5%BF. Thus, ethnic-specific SKF and NIR equations were developed. For the SKF model, the sigma3SKF (triceps, axilla, and suprailium) and age explained 67.3% of the variance in Db:Db = 1.06198316 -0.00038496(sigma3SKF) -0.00020362(age). Cross-validation analysis yielded r = 0.88, SEE = 0.0068 g x cc(-1), E = 0.0070 g x cc(-1), and no significant difference between predicted and criterion Db. For the NIR model, the hip circumference, sigma2AdeltaOD2 (biceps and chest), FIT index, age, and height explained 73.9% of the variance in Db:Db = 1.0707606 -0.0009865(hip circumference) -0.0369861(sigma2deltaOD2) + 0.0004167(height) + 0.0000866(FIT index) -0.0001894(age). Cross-validation yielded r = 0.85, SEE = 0.0076 g x cc(-1), E = 0.0079 g x cc(-1), and a small, but significant, difference between predicted and criterion Db. CONCLUSIONS: We recommend using the ethnic-specific SKF and NIR equations developed in this study to estimate Db of American Indian women.


Asunto(s)
Absorciometría de Fotón/normas , Composición Corporal , Índice de Masa Corporal , Indígenas Norteamericanos , Grosor de los Pliegues Cutáneos , Adolescente , Adulto , Femenino , Humanos , Persona de Mediana Edad , Obesidad/diagnóstico , Sensibilidad y Especificidad , Salud de la Mujer
19.
J Womens Health Gend Based Med ; 8(6): 805-13, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10495261

RESUMEN

Using data from 12 days of detailed physical activity records (PA records), we analyzed the physical activity patterns of 141 African American and Native American women, ages 40 and older, enrolled in the Cross-Cultural Activity Participation Study. PA records were completed every other month for three consecutive 4-day periods. The proportion of women who met the 1993 Centers for Disease Control and Prevention and the American College of Sports Medicine recommendation to accumulate at least 30 minutes of moderate intensity activity during most days of the week (at least 3 days of the 4-day periods) ranged from 63% to 70%. Nearly one third of women met the recommendation for more than one 4-day period. On days when subjects accumulated at least 30 minutes of moderate activity, time spent in moderate activity was 112 minutes/day. Most women performed household chores (95%, median = 24 minutes/day), walking for exercise (87%, median = 30 minutes/day), occupational (65%, median = 37 minutes/day), child care (53%, median = 32 minutes/day), and lawn and garden activities (51%, median = 43 minutes/day). Fewer than 25% reported conditioning and sports activities. In general, more Native Americans than African Americans were active in moderate activities. In conclusion, definitions used to characterize regular physical activity should be consistent among studies, and physical activity surveys among women should include occupation-related and home-related activities.


Asunto(s)
Actividades Cotidianas , Negro o Afroamericano/estadística & datos numéricos , Ejercicio Físico , Indígenas Norteamericanos/estadística & datos numéricos , Grupos Minoritarios/estadística & datos numéricos , Mujeres , Adulto , Anciano , Anciano de 80 o más Años , Comparación Transcultural , Femenino , Humanos , Persona de Mediana Edad , New Mexico , Ocupaciones/estadística & datos numéricos , South Carolina , Encuestas y Cuestionarios
20.
Ethn Dis ; 9(1): 59-69, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10355475

RESUMEN

OBJECTIVE: Native Americans (NA) have higher diabetes morbidity and mortality compared to other ethnic groups. Although exercise plays an important role in diabetes management, little is known about exercise among Native Americans with diabetes. Our goal was to describe knowledge, attitudes and behaviors related to exercise in Native American participants in New Mexico. DESIGN: Bilingual community members administered a questionnaire to assess knowledge, stage of change (a measure of exercise readiness), and physical activity behavior. Hemoglobin A1c (HbA1c) was measured by DCA 2000 analyzer. Height and weight were measured to calculate body mass index (BMI). Average random blood glucose (RBS) levels and diabetes duration were assessed through chart audit. SETTING: Questionnaires were completed in offices in or near the communities. PARTICIPANTS: 514 Native Americans with diabetes were identified as potential participants, 40% (142 women, 64 men) participated. RESULTS: 37% of participants knew exercise lowers blood sugar. 82% reported they were in the preparation, action, or maintenance stage of change for exercise behavior. Seventy seven percent of this population did not meet the Surgeon General's recommendation for accumulating 30 minutes of leisure time endurance exercise on most days of the week. However, 67% of participants fell within the "high activity" category for all moderate and vigorous activities. Average age, BMI and HbA1c were 58.5 yrs., 30.5 kg/m2, 8.6%, respectively. CONCLUSIONS: Interventions to increase physical activity awareness and participation could improve diabetes management and overall health for Native Americans. When evaluating physical activity, researchers need to consider usual activities of daily living and leisure time activities specific to that population. Failure to do so would be ethnocentric and could lead to inappropriate conclusions.


Asunto(s)
Actitud Frente a la Salud/etnología , Diabetes Mellitus/etnología , Ejercicio Físico/psicología , Conocimientos, Actitudes y Práctica en Salud , Indígenas Norteamericanos/psicología , Actividades Cotidianas/psicología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Glucemia/análisis , Índice de Masa Corporal , Diabetes Mellitus/sangre , Diabetes Mellitus/prevención & control , Femenino , Hemoglobina Glucada/análisis , Humanos , Actividades Recreativas/psicología , Masculino , Persona de Mediana Edad , New Mexico , Autocuidado/métodos , Autocuidado/psicología , Encuestas y Cuestionarios , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA