Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Zhonghua Yi Xue Za Zhi ; 104(21): 1972-1978, 2024 Jun 04.
Artículo en Chino | MEDLINE | ID: mdl-38825940

RESUMEN

Objective: To explore the relationship between the onset time of sepsis-associated acute kidney injury (SA-AKI) and adverse clinical outcomes. Methods: Data were derived from Beijing Acute Kidney Injure Trial (BAKIT) which investigated the epidemiology of acute kidney injury (AKI) in critically ill patients at 30 intensive care units (ICU) of 28 tertiary hospitals in Beijing from 1 March to 31 August 2012. Patients who were older than 18 years and diagnosed with sepsis and AKI, and expected to stay in ICU for at least 24 h were included in this study. A total of 653 patients were included in this study, 414 males and 239 females with a mean age of (68.2±17.0) years. According to the onset time of SA-AKI, patients were grouped into early AKI (E-AKI) (AKI occurred within 48 hours after ICU admission) and late AKI (L-AKI) (AKI occurred after 48 hours of ICU admission) group. The primary outcome was major adverse kidney events (MAKE), consisted of all-cause mortality, renal replacement therapy-dependence, and an inability to recover to 1.5 times of the baseline creatinine value up to 30 days. Multivariable logistic regression was used to investigate the association between the onset time of SA-AKI and clinical outcomes. Results: A total of 653 patients with SA-AKI were included, 423 (64.8%) patients developed E-AKI, 230 (35.2%) cases developed L-AKI, MAKE occurred in 405 (62.0%) cases, and 301 (46.1%) patients died in hospital. Compared with E-AKI group, L-AKI patients showed higher AKI 3 level rate [55.7%(128/230) vs 40.2%(170/423), P<0.001], incidence of MAKE [72.6%(167/230) vs 56.3%(238/423,P<0.001)] and hospital mortality [55.2%(127/230) vs 44.1%(174/423), P=0.001]. The risk of MAKE and in-hospital mortality in L-AKI group increased for 2.55-fold times (OR=3.55, 95%CI: 1.94-6.04) and 1.84-fold times (OR=2.84, 95%CI: 1.44-5.60) when compared with those in E-AKI, respectively (both P<0.05). Conclusion: Late timing onset of SA-AKI is associated with poor clinical outcomes.


Asunto(s)
Lesión Renal Aguda , Unidades de Cuidados Intensivos , Sepsis , Humanos , Lesión Renal Aguda/etiología , Sepsis/complicaciones , Masculino , Femenino , Persona de Mediana Edad , Anciano , Mortalidad Hospitalaria , Enfermedad Crítica , Factores de Tiempo , Terapia de Reemplazo Renal , Modelos Logísticos
2.
Nanotechnology ; 28(7): 075501, 2017 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-27977004

RESUMEN

A carbon monoxide (CO) thermoelectric (TE) gas sensor was fabricated by affixing a Au/Co3O4 catalyst tablet on a TE film layer. The Au/Co3O4 catalyst tablet was prepared by a co-precipitation and tablet compression method and its possible catalytic mechanism was discussed by means of x-ray diffraction, field emission scanning electron microscopy, high resolution transmission electron microscopy, x-ray photoelectron spectroscopy, temperature-programmed reduction of hydrogen, Fourier transform infrared spectroscopy and Brunauer-Emmett-Teller analysis. The optimal catalyst, with a Au content of 10 wt%, was obtained at a calcination temperature between 200 and 300 °C. The small size of the Au nanoparticles, high specific surface, the existence of Co3+ and water-derived species contributed to  high catalytic activity. Based on the optimal Au/Co3O4 catalyst tablet, the CO TE gas sensor worked at room temperature and showed a response voltage signal (ΔV) of 23 mV, high selectivity among hydrogen and methane, high stability, and a fast response time of 106 s for 30 000 ppm CO/air. In addition, a CO concentration in the range of 5000-30 000 ppm could obviously be detected and exhibited a linear relationship with ΔV. The CO TE gas sensor provides a promising option for the detection of CO gas at room temperature.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA