Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Hum Factors ; 65(7): 1407-1421, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-34974764

RESUMEN

OBJECTIVE: To investigate the digit force control during a five-digit precision grasp in aligned (AG) and unaligned grasping (UG) configurations. BACKGROUND: The effects of various cylindrical handles for tools on power grasp performance have been previously investigated. However, there is little information on force control strategy of precision grasp to fit various grasping configurations. METHOD: Twenty healthy young adults were recruited to perform a lift-hold-lower task. The AG and UG configurations on a cylindrical simulator with force transducers were adjusted for each individual. The applied force and moment, the force variability during holding, and force correlations between thumb and each finger were measured. RESULT: No differences in applied force, force correlation, repeatability, and variability were found between configurations. However, the moments applied in UG were significantly larger than those in AG. CONCLUSION: The force control during precision grasp did not change significantly across AG and UG except for the digit moment. The simulator is controlled efficiently with large moment during UG, which is thus the optimal configuration for precision grasping with a cylindrical handle. Further research should consider the effects of task type and handle design on force control, especially for individuals with hand disorders. APPLICATION: To design the handle of specific tool, one should consider the appropriate configuration according to the task requirements of precision grasping to reduce the risk of accumulating extra loads on digits with a cylindrical handle.


Asunto(s)
Dedos , Fuerza de la Mano , Adulto Joven , Humanos , Desempeño Psicomotor
2.
Sensors (Basel) ; 18(2)2018 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-29414850

RESUMEN

In this paper, a fiber Bragg grating (FBG)-based stress monitoring system instrumented on an orthotropic steel deck arch bridge is demonstrated. The FBG sensors are installed at two types of critical fatigue-prone welded joints to measure the strain and temperature signals. A total of 64 FBG sensors are deployed around the rib-to-deck and rib-to-diagram areas at the mid-span and quarter-span of the investigated orthotropic steel bridge. The local stress behaviors caused by the highway loading and temperature effect during the construction and operation periods are presented with the aid of a wavelet multi-resolution analysis approach. In addition, the multi-modal characteristic of the rainflow counted stress spectrum is modeled by the method of finite mixture distribution together with a genetic algorithm (GA)-based parameter estimation approach. The optimal probability distribution of the stress spectrum is determined by use of Bayesian information criterion (BIC). Furthermore, the hot spot stress of the welded joint is calculated by an extrapolation method recommended in the specification of International Institute of Welding (IIW). The stochastic characteristic of stress concentration factor (SCF) of the concerned welded joint is addressed. The proposed FBG-based stress monitoring system and probabilistic stress evaluation methods can provide an effective tool for structural monitoring and condition assessment of orthotropic steel bridges.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA