Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Ann Pediatr Cardiol ; 17(1): 81-84, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38933059

RESUMEN

A neonate born of third-degree consanguineous marriage presented on day 12 of life with congestive cardiac failure. A male sibling died at 3 months of age, cause of which was not known. He was treated with decongestive measures and multiple inotropes. 2D Echocardiogram revealed severe Left ventricular dysfunction with prominent trabeculations and deep recesses in the left ventricle suggestive of Left ventricular non-compaction. He was also found to have horse-shoe kidney. Considering the presence of cardiac left ventricular non compaction, horse-shoe kidney and family history of neonatal death and pregnancy loss clinical exome sequencing was done. It detected a homozygous missense variant in exon 6 of the AGK gene suggestive of Senger's syndrome. Baby was on regular follow-up and was thriving well on diuretics, sacubitril-valsartan and weekly levosimendan infusions. At 8 months of age, cardiac transplantation was successfully done and baby has been doing well post-transplantation. LVNC in children is rare with an estimated incidence of 0.11 per 100,000, the highest incidence being during infancy. Senger's syndrome is autosomal recessive in inheritance. Senger's syndrome associated with Left ventricular non compaction has been reported only once in literature so far. Renal manifestations in the form of horse shoe kidney like in our index baby has not been reported previously with Senger's syndrome.

2.
Heart Lung Circ ; 33(3): 292-303, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38360502

RESUMEN

BACKGROUND & AIM: The deleterious consequences of chronically elevated venous pressure in patients with profound right ventricular or biventricular dysfunction are well known, including renal and hepatic dysfunction, and volume overload. The only option for these patients, if they fail optimal medical treatment, is a heart transplant, as they are not candidates for left ventricular assist device therapy. Mean perfusion pressure (MPP) is important in the outcomes of critically ill patients with high venous pressure. The question arises whether MPP is important for the outcomes of heart transplants in patients with elevated pre-transplant venous pressure. Medical management of heart failure patients with reduced ejection fraction involves lowering the systemic afterload with vasodilators while awaiting a transplant. We hypothesised that when venous pressure is elevated prior to transplant, a substantial reduction in systemic arterial elastance (Ea) through vasodilation may significantly decrease MPP, resulting in compromised end-organ function and consequent unfavourable outcomes after heart transplantation. This study aims to investigate whether a low MPP serves as a risk factor for adverse outcomes in heart transplant recipients with high venous pressure. METHOD: A retrospective analysis was conducted on 250 heart transplant recipients undergoing isolated heart transplantation at a single institution from October 2012 to March 2020. Right atrial pressure (RAP) of more than 15 mmHg was considered high. Additionally, Ea calculated as the ratio of end-systolic pressure to stroke volume, and MPP calculated as the difference between mean arterial pressure and RAP were considered in our analysis. The outcomes of transplantation were measured in terms of 90-day mortality and survival up to 7 years. RESULTS: High RAP was a significant risk factor for short-term and medium-term survival if Ea was low (<2.7 mmHg/mL, the median value). This group had 39.39% in-hospital mortality compared to 14.49% for RAP<15 mmHg (p∼0.005). When Ea was high, this difference in survival was not evident: 8% for RAP<15 mmHg vs 4.8% for RAP>15 mmHg (p∼0.550). This effect was mediated through a lower MPP, and the mortality due to lower MPP increased strikingly with higher body surface area (BSA). A negative correlation was observed between MPP indexed to BSA (MPPI) and the Model for End-Stage Liver Disease score (r∼-0.3580, p<0.0001) as well as creatinine (r∼-0.3551, p<0.0001). MPPI less than 40 mmHg/m2 was associated with poorer short-term (23.2% for MPPI<40 mmHg/m2 vs 7.1% for MPPI>40 mmHg/m2, p∼0.001) and medium-term survival. The impact of high RAP and low Ea on survival was evident even on medium-term follow-up; only 30% survival at 7 years follow-up for high RAP and low Ea vs 75% for RAP<15 mmHg (p∼0.0033). CONCLUSION: The acceptable blood pressure during vasodilator therapy in patients with high RAP needs to be higher, especially in those with higher BSA. MPPI less than 40 mmHg/m2 is a risk factor for survival, in the short and medium-term, after heart transplantation.


Asunto(s)
Enfermedad Hepática en Estado Terminal , Insuficiencia Cardíaca , Trasplante de Corazón , Humanos , Estudios Retrospectivos , Superficie Corporal , Enfermedad Hepática en Estado Terminal/complicaciones , Índice de Severidad de la Enfermedad , Presión Venosa , Vasodilatadores , Perfusión
3.
Ann Card Anaesth ; 20(1): 108-109, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28074808

RESUMEN

In spite of distal perfusion of the limb using a cannula, the limb can have ischemic events if there is an undetected kink or clot anywhere in the line or thrombus in the artery. There are several ways to monitor and assess the limb ischemia. Monitoring for clinical signs of limb ischemia like temperature change and pallor is reliable and mandatory. We report a method where we used color Doppler to document the blood flow. Curvilinear vascular probe of an echo machine is used to identify the flow in the distal femoral artery of the lower limb. . As we have demonstrated in the video attached, once flow to the distal limb perfusion system is shut off by closing the three way stop cock, we can appreciate the immediate cessation of flow in the artery by Doppler.


Asunto(s)
Cateterismo Periférico , Oxigenación por Membrana Extracorpórea , Arteria Femoral/diagnóstico por imagen , Ultrasonografía Doppler en Color/métodos , Velocidad del Flujo Sanguíneo/fisiología , Arteria Femoral/fisiología , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA