Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur Heart J Imaging Methods Pract ; 2(3): qyae103, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39439746

RESUMEN

Aims: Structural heart defects, including congenital ventricular septal defect closure or intracardiac rerouting, frequently require surgical reconstruction using hand-cut patch materials. Digitally modelled patch templates may improve patch fit and reduce outflow tract obstruction, residual defect risk, and conduction system damage. In this study, we benchmarked mixed-reality and a desktop application against a digitalized model of a real implanted patch. Methods and results: Ten patients scheduled for the repair of various defects consented to prospective inclusion in the study. After surgery, a digital model of the implanted patch was created from the residual material. Five clinical experts created 10 digital patches, 1 per patient, both in mixed-reality and desktop application, for comparison with the reference measurements, including the digitalized model of the real patch used during the surgery. Subjective residual shunt risk prediction was performed using both modalities. Digital patches created in mixed-reality closely matched the surgical material, whereas those created using desktop applications were significantly smaller. Different evaluators showed varying preferences for the application of the residual shunt risk and area. Conclusion: Digitally created patches can assist surgeons in preoperatively sizing of patch implants, potentially reducing post-operative complications.

2.
Abdom Radiol (NY) ; 46(7): 3205-3216, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33688987

RESUMEN

PURPOSE: Patients with Fontan circulation are at risk of developing hepatic fibrosis/cirrhosis. The mechanisms and disease development are unclear and early secondary liver cancer is a concern. This study will describe hepatic imaging findings in a national cohort of adolescents with Fontan circulation. METHODS: The patients prospectively underwent abdominal contrast enhanced magnetic resonance imaging (MRI) including diffusion-weighted imaging. Images were assessed for criteria of fibrosis/cirrhosis including characterization of hepatic nodules. These nodules were in addition, assessed by ultrasonography (US). Nodules ≥ 1 cm were investigated and monitored to evaluate malignant transformation. Clinical and hepatic serological data were recorded. RESULTS: Forty-six patients, median age of 16.5 years (15.4-17.9 years) were enrolled. All patients underwent US examination and MRI was performed in 35/46 patients. On MRI, 60% had hepatomegaly and 37% had signs of fibrosis/cirrhosis. Seven patients had together 13 nodules ≥ 1 cm in diameter. Only 4/13 (17%) where seen on US. Nodules had variable MRI signal characteristics including hepatobiliary contrast enhancement and two nodules revealed portal venous phase 'wash-out' on the first examination. No further imaging signs of malignancy were revealed during the follow-up period of median 24.4 (7-42) months. CONCLUSION: The majority of adolescents with Fontan circulation had imaging findings of fibrosis/cirrhosis of varying severity. US had low detection rate of hepatic nodules compared to MRI. The imaging work-up before transition to adult cardiology care did not reveal findings suggestive of malignancy. However, the high prevalence of Fontan-associated liver disease calls for surveillance strategies even in childhood.


Asunto(s)
Procedimiento de Fontan , Neoplasias Hepáticas , Adolescente , Adulto , Humanos , Hígado/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética , Ultrasonografía
3.
Pediatr Radiol ; 51(1): 66-76, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33033916

RESUMEN

BACKGROUND: Children with Fontan circulation are at risk of developing hepatic fibrosis/cirrhosis. Reliable noninvasive monitoring techniques are lacking or under development. OBJECTIVE: To investigate surrogate indicators of hepatic fibrosis in adolescents with Fontan circulation by evaluating hepatic magnetic resonance (MR) T1 mapping and extracellular volume fraction measurements compared to US shear-wave elastography. MATERIALS AND METHODS: We analyzed hepatic native T1 times and extracellular volume fractions with modified Look-Locker inversion recovery. Liver stiffness was analyzed with shear-wave elastography. We compared results between 45 pediatric patients ages 16.7±0.6 years with Fontan circulation and 15 healthy controls ages 19.2±1.2 years. Measurements were correlated to clinical and hemodynamic data from cardiac catheterization. RESULTS: MR mapping was successful in 35/45 patients, revealing higher hepatic T1 times (774±44 ms) than in controls (632±52 ms; P<0.001) and higher extracellular volume fractions (47.4±5.0%) than in controls (34.6±3.8%; P<0.001). Liver stiffness was 1.91±0.13 m/s in patients vs. 1.20±0.10 m/s in controls (P<0.001). Native T1 times correlated with central venous pressures (r=0.5, P=0.007). Native T1 was not correlated with elastography in patients (r=0.2, P=0.1) or controls (r = -0.3, P=0.3). Extracellular volume fraction was correlated with elastography in patients (r=0.5, P=0.005) but not in controls (r=0.2, P=0.6). CONCLUSION: Increased hepatic MR relaxometry and shear-wave elastography values in adolescents with Fontan circulation suggested the presence of hepatic fibrosis or congestion. Central venous pressure was related to T1 times. Changes were detected differently with MR relaxometry and elastography; thus, these techniques should not be used interchangeably in monitoring hepatic fibrosis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Procedimiento de Fontan , Hepatopatías , Adolescente , Adulto , Niño , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Hepatopatías/patología , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Adulto Joven
4.
Tidsskr Nor Laegeforen ; 140(17)2020 11 24.
Artículo en Inglés, Noruego | MEDLINE | ID: mdl-33231396

RESUMEN

New methods for holographic visualisation provide a true three-dimensional experience of medical images. The technique is generating great interest among surgeons.


Asunto(s)
Realidad Aumentada , Humanos , Imagenología Tridimensional , Tecnología
5.
Pediatr Radiol ; 48(11): 1567-1575, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29974179

RESUMEN

BACKGROUND: Assessment of qualitative or subjective image quality in radiology is traditionally performed using a fixed-point scale even though reproducibility has proved challenging. OBJECTIVE: Image quality of 3-T coronary magnetic resonance (MR) angiography was evaluated using three scoring methods, hypothesizing that a continuous scoring scale like visual analogue scale would improve the assessment. MATERIALS AND METHODS: Adolescents corrected for transposition of the great arteries with arterial switch operation, ages 9-15 years (n=12), and healthy, age-matched controls (n=12), were examined with 3-D steady-state free precession magnetic resonance imaging. Image quality of the coronary artery origin was evaluated by using a fixed-point scale (1-4), visual analogue scale of 10 cm and a visual analogue scale with reference points (figurative visual analogue scale). Satisfactory image quality was set to a fixed-point scale 3=visual analogue scale/figurative visual analogue scale 6.6 cm. Statistical analysis was performed using Cohen kappa coefficient and agreement index. RESULTS: The mean interobserver scores for the fixed-point scale, visual analogue scale and figurative visual analogue scale were, respectively, in the left main stem 2.8, 5.7, 7.0; left anterior descending artery 2.8, 4.7, 6.6; circumflex artery 2.5, 4.5, 6.2, and right coronary artery 3.2, 6.3, 7.7. Scoring with a fixed-point scale gave an intraobserver κ of 0.52-0.77 while interobserver κ was lacking. For visual analogue scale and figurative visual analogue scale, intraobserver agreement indices were, respectively, 0.08-0.58 and 0.43-0.71 and interobserver agreement indices were up to 0.5 and 0.65, respectively. CONCLUSION: Qualitative image quality evaluation with coronary 3-D steady-state free precession MR angiography, using a visual analogue scale with reference points, had better reproducibility compared to a fixed-point scale and visual analogue scale. Image quality, being a continuum, may be better determined by this method.


Asunto(s)
Angiografía por Resonancia Magnética/normas , Calidad de la Atención de Salud , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía , Escala Visual Analógica , Adolescente , Estudios de Casos y Controles , Niño , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA