Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Hum Vaccin Immunother ; 20(1): 2330168, 2024 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-38567541

RESUMEN

Human papillomavirus (HPV) vaccines, primarily relying on neutralizing antibodies, have proven highly effective. Recently, HPV-specific antibodies have been detected in the female genital tract secretions captured by first-void urine (FVU), offering a minimally invasive diagnostic approach. In this study, we investigated whether HPV16-specific antibodies present in FVU samples retain their neutralizing capacity by using pseudovirion-based neutralization assays. Paired FVU and serum samples (vaccinated n = 25, unvaccinated n = 25, aged 18-25) were analyzed using two orthogonal pseudovirion-based neutralization assays, one using fluorescence microscopy and the other using luminescence-based spectrophotometry. Results were compared with HPV16-specific IgG concentrations and correlations between neutralizing antibodies in FVU and serum were explored. The study demonstrated the presence of neutralizing antibodies in FVU using both pseudovirion-based neutralization assays, with the luminescence-based assay showing higher sensitivity for FVU samples, while the fluorescence microscopy-based assay exhibited better specificity for serum and overall higher reproducibility. High Spearman correlation values were calculated between HPV16-IgG and HPV16-neutralizing antibodies for both protocols (rs: 0.54-0.94, p < .001). Significant Spearman correlations between FVU and serum concentrations were also established for all assays (rs: 0.44-0.91, p < .01). This study demonstrates the continued neutralizing ability of antibodies captured with FVU, supporting the hypothesis that HPV vaccination may reduce autoinoculation and transmission risk to the sexual partner. Although further protocol optimizations are warranted, these findings provide a foundation for future research and larger cohort studies that could have implications for the optimal design, evaluation, and implementation of HPV vaccination programs.


Asunto(s)
Infecciones por Papillomavirus , Vacunas contra Papillomavirus , Humanos , Femenino , Adolescente , Adulto Joven , Adulto , Infecciones por Papillomavirus/prevención & control , Reproducibilidad de los Resultados , Anticuerpos Antivirales , Anticuerpos Neutralizantes , Pruebas de Neutralización/métodos , Genitales Femeninos , Papillomavirus Humano 16 , Inmunoglobulina G
2.
Eur J Med Res ; 29(1): 131, 2024 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-38368382

RESUMEN

BACKGROUND: First-void urine (FVU) provides a non-invasive method for collecting a wide range of biomarkers found in genital tract secretions. To optimize biomarker collection in FVU, this study investigated the impact of naturally present and supplemented precipitating agents: uromodulin (UMOD) and polyethylene glycol (PEG), on the concentration of human papillomavirus (HPV) pseudovirions (PsV), cell-free DNA (cfDNA), and cellular genomic DNA (gDNA) through centrifugation. METHODS: FVU samples from ten healthy female volunteers, along with a control sample, were spiked with seal herpesvirus 1 (PhHV-1) DNA, HPV16 plasmid DNA, and HPV16 PsV with an enhanced green fluorescent protein (EGFP) reporter. The samples were subjected to various concentration protocols involving PEG precipitation, low-speed centrifugation (5 min at 1000×g), and medium-speed centrifugation (1 h at 3000×g). Subsequently, quantitative PCR (qPCR) was used to assess cellular and cell-free glyceraldehyde-3-phosphate dehydrogenase (GAPDH) DNA, cell-free PhHV-1 and HPV16 DNA, and PsV (EGFP) DNA. In addition, UMOD levels were measured. RESULTS: The findings revealed that PEG significantly increased the concentration of cfDNA and gDNA in the pellet after centrifugation, with the most pronounced effect observed for cfDNA. Moreover, low-speed centrifugation without PEG effectively depleted cellular gDNA while preserving cfDNA in the supernatants. Pseudovirions were consistently pelleted, even with low-speed centrifugation, and a positive but not significant effect of PEG on PsV (EGFP) DNA yield in the pellet was observed. Additionally, a significant correlation was observed between UMOD and GAPDH, HPV16, and PsV (EGFP) DNA quantities in the pellet. Furthermore, large variations among the FVU samples were observed. CONCLUSIONS: With this study, we provide novel insights into how various biomarker precipitation protocols, including both the properties of FVU and the use of PEG as a precipitating agent, influence the concentration of cfDNA, cellular gDNA, and pseudovirions.


Asunto(s)
Ácidos Nucleicos Libres de Células , Papillomavirus Humano 16 , Humanos , Femenino , Papillomavirus Humano 16/genética , Biomarcadores , ADN
3.
J Med Virol ; 95(10): e29133, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37812015

RESUMEN

Assessment of humoral immune responses following human papillomavirus (HPV) vaccination currently relies on invasive blood sampling. This longitudinal cohort study explores the usability of first-void urine as a noninvasive alternative sample for antibody detection. In this study, 58 women receiving three doses of the 9vHPV vaccine within a Gardasil9 (9vHPV) Phase III randomized controlled trial were included. Participants provided paired first-void urine and blood samples before vaccination (M0), 1 month after the third dose (M7), and ~3 years after the third dose (M43). Type-specific antibody responses to the 9vHPV types were analyzed in 174 first-void urine and 172 serum samples using a virus-like particle-based IgG multiplex enzyme-linked immunosorbent assay. Additionally, total human IgG concentrations were determined using the BioPlex assay. At M7, 1 month after complete 9vHPV vaccination, 95%-100% of first-void urine and 100% of serum samples had detectable concentrations, varying by HPV type. At M43, 84%-100% of first-void urine and 98%-100% of serum samples had HPV-specific antibody concentrations. Results show significant Spearman rank correlations between type-specific HPV-antibody concentrations for paired first-void urine and serum at all time points. This study confirms the potential feasibility of utilizing first-void urine as a noninvasive immunological sample within HPV vaccine trials.


Asunto(s)
Infecciones por Papillomavirus , Vacunas contra Papillomavirus , Femenino , Humanos , Anticuerpos Antivirales , Estudios de Seguimiento , Inmunidad Humoral , Inmunoglobulina G , Estudios Longitudinales , Infecciones por Papillomavirus/prevención & control , Vacunación
4.
Prev Med Rep ; 35: 102368, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37680853

RESUMEN

The 12th HPV Prevention and Control meeting was held on June 2-3, 2022, in Antwerp, Belgium. This technical meeting focused on several topics. This report summarises the discussions and lessons learned on two topics: an update on one-dose HPV vaccination studies and humoral immune responses upon HPV vaccination. Long-term follow-up studies from Costa Rica (eleven years) and India (ten years) report stable levels of antibodies after a single HPV vaccination. High vaccine effectiveness against incident persistent HPV 16/18 infection was seen in India (95.4%, 85.0-99.9) ten years postvaccination and in Kenya (97.5%, 81.7-99.7) eighteen months postvaccination, an important observation in a setting with a higher HPV prevalence. The potential impact of HPV vaccination using a one-dose schedule in India was modelled and showed that implementation of one-dose schedule can contribute towards achieving WHO Cervical Cancer elimination goals. These data support the WHO SAGE recommendations for adopting a one-dose schedule for females aged 9-20 years. Immunobridging studies were discussed during the meeting. General agreement was reached that when thoughtfully applied, they can support and accelerate the expanded use of HPV vaccine with new vaccine schedules, age cohorts, or vaccine formulations. Internationally standardised measurements of HPV immune responses important for the progress of HPV vaccinology field. Humoral immune responses upon HPV vaccination plateau at 24 months regardless of number of doses, therefore, data should be analysed after at least 24 months of follow-up to bridge studies accurately.

5.
Molecules ; 26(7)2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33915837

RESUMEN

The potential of first-void (FV) urine as a non-invasive liquid biopsy for detection of human papillomavirus (HPV) DNA and other biomarkers has been increasingly recognized over the past decade. In this study, we investigated whether the volume of this initial urine stream has an impact on the analytical performance of biomarkers. In parallel, we evaluated different DNA extraction protocols and introduced an internal control in the urine preservative. Twenty-five women, diagnosed with high-risk HPV, provided three home-collected FV urine samples using three FV urine collection devices (Colli-Pee) with collector tubes that differ in volume (4, 10, 20 mL). Each collector tube was prefilled with Urine Conservation Medium spiked with phocine herpesvirus 1 (PhHV-1) DNA as internal control. Five different DNA extraction protocols were compared, followed by PCR for GAPDH and PhHV-1 (qPCR), HPV DNA, and HBB (HPV-Risk Assay), and ACTB (methylation-specific qPCR). Results showed limited effects of collection volume on human and HPV DNA endpoints. In contrast, significant variations in yield for human endpoints were observed for different DNA extraction methods (p < 0.05). Additionally, the potential of PhHV-1 as internal control to monitor FV urine collection, storage, and processing was demonstrated.


Asunto(s)
Biomarcadores , ADN Viral , Técnicas de Diagnóstico Molecular , Papillomaviridae , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/orina , Adulto , ADN Viral/aislamiento & purificación , ADN Viral/orina , Femenino , Humanos , Persona de Mediana Edad , Papillomaviridae/genética , Infecciones por Papillomavirus/virología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Flujo de Trabajo , Adulto Joven
6.
Front Immunol ; 11: 1657, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32849573

RESUMEN

The potential of first-void (FV) urine as a non-invasive method to monitor human papillomavirus (HPV) vaccination has been reported, mainly focusing on urine as a sample to assess HPV DNA. Besides HPV DNA, vaccine-induced HPV antibodies originating from cervicovaginal secretions were recently shown to be detectable in FV urine as well. This presents a novel opportunity for non-invasive sampling to monitor HPV antibody status in women participating in large epidemiological studies and HPV vaccine trials. The simultaneous assessment of both HPV infection and immunogenicity on a non-invasive, readily obtained sample is particularly attractive.


Asunto(s)
Alphapapillomavirus/inmunología , Anticuerpos Antivirales/orina , Inmunogenicidad Vacunal , Infecciones por Papillomavirus/diagnóstico , Vacunas contra Papillomavirus/uso terapéutico , Biomarcadores/orina , Femenino , Humanos , Infecciones por Papillomavirus/inmunología , Infecciones por Papillomavirus/orina , Infecciones por Papillomavirus/virología , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Urinálisis
7.
J Med Virol ; 92(12): 3774-3783, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32266996

RESUMEN

Vaccine-induced human papillomavirus (HPV) antibodies originating from cervicovaginal secretions were recently shown to be detectable in first-void (FV) urine. This presents a novel opportunity for noninvasive sampling to monitor HPV antibody status in women participating in large epidemiological studies and HPV vaccine trials. With a view towards method optimization, this study compared the measurement of HPV antibodies in FV urine using a multiplex L1/L2 virus-like particles (VLP)-based ELISA (M4ELISA) with previously reported results using a glutathione S-transferase (GST)-L1-based immunoassay (GST-L1-MIA). We tested 53 paired FV urine and serum samples from 19- to 26-year-old healthy women, unvaccinated (n = 17) or vaccinated with either the bivalent or quadrivalent HPV-vaccine during adolescence (n = 36). HPV6/11/16/18 antibodies were measured using M4ELISA and compared with GST-L1-MIA results. Inter-assay and inter-specimen correlations were examined using the Spearman's rank test (rs). As expected, lower HPV antibody concentrations were found in FV urine than in serum. Vaccinated women had significantly higher HPV6/11/16/18 antibody levels in both FV urine and serum compared with those unvaccinated (M4ELISA; FV urine P = .0003; serum P ≤ .0001). HPV antibody levels in FV urine and serum showed a significant positive correlation (M4ELISA anti-HPV6/11/16/18, rs = 0.85/0.86/0.91/0.79, P ≤ .001). Despite assay differences, there was moderate to good correlation between M4ELISA and GST-L1-MIA (FV urine anti-HPV6/11/16/18, rs = 0.86/0.83/0.89/0.53, P ≤ .0001; serum anti-HPV6/11/16/18, rs = 0.93/0.89/0.94/0.75, P ≤ .0001). FV urine HPV antibody detection is comparable with both assays, further supporting this noninvasive sampling method as a possible option for HPV vaccine assessment. Approaches to improve the sensitivity and larger studies are warranted to determine the feasibility of FV urine for vaccine-induced HPV antibody detection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA