Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
BMJ Open ; 14(7): e085637, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38986559

RESUMEN

INTRODUCTION: Central venous access devices (CVADs) are commonly used for the treatment of paediatric cancer patients. Catheter locking is a routine intervention that prevents CVAD-associated adverse events, such as infection, occlusion and thrombosis. While laboratory and clinical data are promising, tetra-EDTA (T-EDTA) has yet to be rigorously evaluated or introduced in cancer care as a catheter lock. METHODS AND ANALYSIS: This is a protocol for a two-arm, superiority type 1 hybrid effectiveness-implementation randomised controlled trial conducted at seven hospitals across Australia and New Zealand. Randomisation will be in a 3:2 ratio between the saline (heparinised saline and normal saline) and T-EDTA groups, with randomly varied blocks of size 10 or 20 and stratification by (1) healthcare facility; (2) CVAD type and (3) duration of dwell since insertion. Within the saline group, there will be a random allocation between normal and heparin saline. Participants can be re-recruited and randomised on insertion of a new CVAD. Primary outcome for effectiveness will be a composite of CVAD-associated bloodstream infections (CABSI), CVAD-associated thrombosis or CVAD occlusion during CVAD dwell or at removal. Secondary outcomes will include CABSI, CVAD-associated-thrombosis, CVAD failure, incidental asymptomatic CVAD-associated-thrombosis, other adverse events, health-related quality of life, healthcare costs and mortality. To achieve 90% power (alpha=0.05) for the primary outcome, data from 720 recruitments are required. A mixed-methods approach will be employed to explore implementation contexts from the perspective of clinicians and healthcare purchasers. ETHICS AND DISSEMINATION: Ethics approval has been provided by Children's Health Queensland Hospital and Health Service Human Research Ethics Committee (HREC) (HREC/22/QCHQ/81744) and the University of Queensland HREC (2022/HE000196) with subsequent governance approval at all sites. Informed consent is required from the substitute decision-maker or legal guardian prior to participation. In addition, consent may also be obtained from mature minors, depending on the legislative requirements of the study site. The primary trial and substudies will be written by the investigators and published in peer-reviewed journals. The findings will also be disseminated through local health and clinical trial networks by investigators and presented at conferences. TRIAL REGISTRATION NUMBER: ACTRN12622000499785.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Neoplasias , Humanos , Niño , Infecciones Relacionadas con Catéteres/prevención & control , Catéteres Venosos Centrales/efectos adversos , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/métodos , Ácido Edético/uso terapéutico , Australia , Trombosis/prevención & control , Trombosis/etiología , Nueva Zelanda , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Calidad de Vida , Heparina/efectos adversos , Heparina/administración & dosificación , Heparina/uso terapéutico
2.
J Pediatr Nurs ; 78: 112-117, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38917612

RESUMEN

BACKGROUND: The PiccPed® health application was developed to support clinical decision-making in peripherally inserted central catheter (PICC) management. We aimed to evaluate its impact on nurses' knowledge regarding the prevention of PICC-associated adverse events in pediatrics and neonatology. METHODS: A quasi-experimental, pre-post intervention study, was conducted with a dependent/paired sample of pediatric and neonatal nurses from two tertiary hospitals in South Brazil. Data were collected from October 2022 to January 2023 across three phases: pre-, intervention (use of the PiccPed®) and post-test. Study outcomes were a knowledge test (15 questions) of evidence-based PICC maintenance procedures, and PiccPed® app time spent and screens used. RESULTS: A total of 56 nurses completed the study. The post-test mean score was significantly higher (12/15; standard deviation (SD) 1.9) in comparison with the pre-test (mean 9/15; SD 2.2). The change in scores was significantly higher for nurses without postgraduate qualifications, in comparison to those with (Mean Difference 1.26; p = 0.039). Each minute using the app resulted in a significant increase of 0.04 points (95% confidence interval 0.01-0.08; p = 0.014) on the mean post-test score (10.94 points). CONCLUSION: The research demonstrated that PiccPed® enhances nurses' learning regarding the prevention of adverse events associated with PICC maintenance in pediatrics and neonatology. APPLICATION TO PRACTICE: The app can be safely and effectively used for training and continuing education of nurses who care for children and neonates with PICCs.

3.
Nurse Educ Pract ; 77: 103983, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38701684

RESUMEN

AIM: To focus learning through clarity of the enrolled nurse (EN) role (a second tier nurse position) through development of a user-friendly workplace performance assessment tool commensurate with EN standards for practice. BACKGROUND: Internationally, the nursing workforce comprises regulated and unregulated staff. In Australia, similar to other western countries, there are two tiers of regulated workforce, namely Registered Nurses (RNs) and Enrolled Nurses (ENs). Differences in RN and EN standards based on the education preparation are not always clearly differentiated in workplace practice. Roles are often seen as interchangeable: Improved clarity of both regulated and unregulated roles, when numbers of healthcare workers are burgeoning, assists performance assessment that guides further learning and safe practice. DESIGN: Two phase sequential, non-experimental design. METHODS: Phase one used focus groups (n=48), expert reference panel (n=8) and end-users (n=16) to develop simple language statements. Phase two involved field testing of the statements. FINDINGS: A 30-item, criterion-based workplace performance tool was developed. Principal component analysis of completed tools indicated work could be organised around three key areas of practice, namely, higher order thinking and problem solving, routine daily activities of care and personal and social attributes. DISCUSSION: Participants reported the statement items assisted in determining suitable activities and accompanying cues in discussing learning needs. Analysis assisted with discriminating broader elements of EN workplace performance. CONCLUSIONS: Workplace learning is important for nurses to continue to build their capacity to deliver optimum care. Assessment tools that describe professional capability in plain language statements and provide examples of supportive behavioural cues help guide on-going learning through improving the validity and thereby consistency of assessment processes. Furthermore, comprehensible and meaningful statements and cues can readily be adopted by students and educators to target learning and feedback thereby enhancing clarity of the EN role, to distinguish from other nursing roles.


Asunto(s)
Grupos Focales , Lugar de Trabajo , Humanos , Australia , Aprendizaje , Competencia Clínica/normas , Rol de la Enfermera
4.
J Clin Nurs ; 33(5): 1762-1776, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38413831

RESUMEN

BACKGROUND: Healthcare consumers require diverse resources to assist their navigation of complex healthcare interactions, however, these resources need to be fit for purpose. AIM: In this study, we evaluated the utility, usability and feasibility of children, families and adults requiring long-term intravenous therapy using a recently developed mobile health application (App), intravenous (IV) Passport. DESIGN: Multi-site, parallel, multi-method, prospective cohort study. METHODS: A multi-site, multi-method study was carried out in 2020-2021, with 46 participants (20 adults, 26 children/family) reporting on their experiences surrounding the use of the IV Passport for up to 6 months. RESULTS: Overall, utility rates were acceptable, with 78.3% (N = 36) using the IV Passport over the follow-up period, with high rates of planned future use for those still active in the project (N = 21; 73%), especially in the child/family cohort (N = 13; 100%). Acceptability rates were high (9/10; IQR 6.5-10), with the IV Passport primarily used for documenting new devices and complications. Thematic analysis revealed three main themes (and multiple subthemes) in the qualitative data: Advocacy for healthcare needs, Complexity of healthcare and App design and functionality. CONCLUSION: Several recommendations were made to improve the end-user experience including 'how to' instructions; and scheduling functionality for routine care. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The IV Passport can be safely and appropriately integrated into healthcare, to support consumers. IMPACT: Patient-/parent-reported feedback suggests the Intravenous Passport is a useful tool for record-keeping, and positive communication between patients/parents, and clinicians. REPORTING METHOD: Not applicable. PATIENT CONTRIBUTION: Consumers reported their experiences surrounding the use of the IV Passport for up to 6 months.


Asunto(s)
Telemedicina , Adulto , Niño , Humanos , Estudios Prospectivos , Telemedicina/métodos , Atención a la Salud , Padres , Comunicación
5.
J Pediatr Nurs ; 76: 68-75, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38364591

RESUMEN

PURPOSE: Children with chronic and complex health conditions frequently need intravenous devices. The current approach to intravenous device selection, insertion, and monitoring is inconsistent, and healthcare consumers are often negatively affected by siloed health information, and poor future planning. Despite child- and family-centred care being recognised as a pillar of paediatric nursing care, limited implementation for vascular access device planning and management is evident. DESIGN AND METHODS: To address this, we conducted a multi-phased approach to co-create, then evaluate, a mobile health (mHealth) application: IV Passport. Co-creation involved a prioritisation survey, followed by a Passport advisory panel consensus meeting. Following confirmation of the required content and features of the Passport, the mHealth application was designed and content validation achieved via survey. RESULTS: The prioritisation survey yielded recommendations for seven features (e.g., graphical presentations of current/past devices). Content for nine device types (e.g., totally implanted ports) was suggested, each with 10 related items (e.g., insertion site). Content items for device-associated complications, future vascular access plans, and educational resources were also suggested. Following design, the application was released through Apple and Android platforms; and adapted to a paper version. Content validation was established; 100% strongly agreed the application was easy to use; 80% agreed/strongly agreed that they would recommend the Passport to others. CONCLUSION: IV Passport embodies effective child- and family-centred care through consumer co-creation to empower patients and families manage vascular access devices. PRACTICE IMPLICATIONS: IV Passport remains active; and can be utilised across many healthcare settings and patient populations.


Asunto(s)
Telemedicina , Dispositivos de Acceso Vascular , Humanos , Niño , Aplicaciones Móviles , Masculino , Femenino , Enfermedad Crónica , Enfermería Pediátrica
7.
Pediatrics ; 153(2)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38287882

RESUMEN

CONTEXT: Central venous access device (CVAD) locks are routine interventions used to prevent and treat complications, such as infection, thrombosis, and catheter occlusion. OBJECTIVE: To compare and rank lock-solutions for prevention or treatment of complications in pediatrics. Design Systematic review and network meta-analysis. DATA SOURCES: Five databases and 2 clinical trial registries were searched. STUDY SELECTION: Published and unpublished randomized controlled trials that enrolled pediatric patients with a CVAD and compared the effectiveness of lock-solutions. DATA EXTRACTION: Data extraction was conducted by 2 reviewers. Odds ratio (OR) for prevention or treatment of CVAD-associated bloodstream infection (BSI), thrombosis, occlusion, CVAD-failure, and mortality were calculated, with point estimates ranking lock-solutions. RESULTS: Twenty-nine studies were included. Chelating agents and antibiotic locks given as prevention were associated with lower odds (OR: 0.11; 95% confidence interval [CI]: 0.02-0.67; moderate-quality; OR: 0.19; 95% CI: 0.05-0.79, high-quality, respectively) of CVAD-associated BSI compared with heparinized saline (reference). Preventative thrombolytic agents had lower odds (OR: 0.64, 95% CI: 0.44-0.93; low-quality) of CVAD occlusion, whereas ethanol had higher odds (OR: 2.84, 95% CI: 1.31-6.16; high-quality) compared with heparinized saline (reference). No lock solution had effects on thrombosis prevention or treatment, CVAD-failure, CVAD-associated BSI treatment failure, or mortality. LIMITATIONS: There was substantial uncertainty around the point estimates because of the limited number of studies for outcomes and study heterogeneity. More high-quality studies are needed to confirm the efficacy of lock solutions. CONCLUSIONS: Chelating agents and antibiotic locks may be effective for CVAD-associated BSI prevention in pediatrics. Thrombolytic agents can be an option for CVAD occlusion prevention, whereas ethanol may not be recommended.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Sepsis , Trombosis , Niño , Humanos , Antibacterianos , Infecciones Relacionadas con Catéteres/prevención & control , Cateterismo Venoso Central/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Quelantes , Etanol , Fibrinolíticos , Metaanálisis en Red , Trombosis/etiología , Trombosis/prevención & control
8.
Pediatr Res ; 96(1): 148-158, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38200324

RESUMEN

BACKGROUND AND AIMS: Invasive devices are widely used in healthcare settings; however, pediatric patients are especially vulnerable to invasive device-associated harm. This study aimed to explore invasive device utility, prevalence, harm, and clinical practice across three Australian pediatric tertiary hospitals. METHODS: In 2022-2023, a multi-center, observational, rolling-point-prevalence survey was conducted. Fifty-per-cent of inpatients were systemically sampled by random allocation. Patients with devices were then followed for up to 3-days for device-related complications/failures and management/removal characteristics. RESULTS: Of the 285 patients audited, 78.2% had an invasive device (n = 412 devices), with a median of 1 device-per-patient (interquartile range 1-2), with a maximum of 13 devices-per-patient. Over half of devices were vascular access devices (n = 223; 54.1%), followed by gastrointestinal devices (n = 112; 27.2%). The point-prevalence of all device complications on Day 0 was 10.7% (44/412 devices) and period-prevalence throughout the audit period was 27.7% (114/412 devices). The period-prevalence of device failure was 13.4% (55/412 devices). CONCLUSIONS: The study highlighted a high prevalence of invasive devices among hospitalized patients. One-in-ten devices failed during the audit period. These findings underscore the need for vigilant monitoring and improved strategies to minimize complications and enhance the safety of invasive devices in pediatric hospital settings. IMPACT: A high prevalence of invasive devices among hospitalized patients was reported. Of the 285 patients audited, almost 80% had an invasive device (total 412 devices), with a median of 1 device-per-patient and a maximum of 13 devices-per-patient. The most common devices used in pediatric healthcare are vascular access devices (n = 223; 54.1%), however, 16% (n = 36) of these devices failed, and one-third had complications. The point prevalence of all device complications at day 0 was 10.7% (44 out of 412 devices), with a period prevalence of 27.7% (114 out of 412 devices) throughout the audit period.


Asunto(s)
Centros de Atención Terciaria , Humanos , Niño , Masculino , Femenino , Preescolar , Prevalencia , Lactante , Australia/epidemiología , Adolescente , Falla de Equipo/estadística & datos numéricos , Dispositivos de Acceso Vascular/efectos adversos , Recién Nacido , Encuestas y Cuestionarios , Hospitales Pediátricos
9.
J Adv Nurs ; 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38263365

RESUMEN

AIM: This study aimed to estimate the proportion and rate of skin complications and mechanical dysfunction associated with indwelling invasive devices in paediatric healthcare. DESIGN: This systematic review is reported in accordance with Cochrane standards for randomized controlled trials and the Meta-analysis of Observation Studies in Epidemiology for cohort studies. DATA SOURCES: MEDLINE, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched. REVIEW METHODS: Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) paediatric participants admitted to a hospital, (3) reporting post-insertion device-associated skin complication and/or mechanical dysfunction, and (4) published in English, were included. Device-associated skin complication and mechanical dysfunction (infiltration, leakage, occlusion/blockage, dislodgement/malposition, breakage and others). Pooled proportion and incidence rate per 1000 device days are reported. RESULTS: This review synthesized 114 studies (30,782 devices; 1,635,649 device-days). Skin complications were reported in 40 studies, but none exclusively reported individual device-related pressure injuries. Mechanical dysfunctions were well-reported for central venous access devices, peripheral intravenous catheters, nasogastric/gastric tubes and peritoneal dialysis catheters but less for arterial catheters, extracorporeal membrane oxygenation and ventricular assist devices. CONCLUSIONS: This systematic review highlights the need for standardized definitions and reporting methods to better surveil and benchmark device-related complications, particularly for understudied device types. Device-related pressure injuries were not reported in any of the included studies, and all devices except for vascular access devices require standardized reporting of complications. IMPACT: Despite the widespread use of invasive devices, comprehensive data on their prevalence, utility, and associated paediatric complications is limited. This review identified prevalent skin complications, occlusions and dislodgments in children with devices, underscoring the need for standardized reporting to enhance surveillance and understanding of paediatric device-related complications. REPORTING METHOD: MOOSE (Meta-analyses Of Observational Studies in Epidemiology) Checklist. PATIENT OR PUBLIC CONTRIBUTION: No Patient or Public Contribution.

10.
Int J Environ Health Res ; : 1-14, 2024 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-38245844

RESUMEN

The association of air pollution and greenspace with respiratory pathogen acquisition and respiratory health was investigated in a community-based birth-cohort of 158 Australian children. Weekly nasal swabs and daily symptom-diaries were collected for 2-years, with annual reviews from ages 3-7-years. Annual exposure to fine-particulate-matter (PM2.5), nitrogen-dioxide (NO2), and normalised-difference-vegetation-index (NDVI) was estimated for pregnancy and the first 2-years-of-life. We examined rhinovirus, any respiratory virus, Streptococcus pneumoniae, Moraxella catarrhalis, and Haemophilus influenzae detections in the first 3-months-of-life, age at initial pathogen detection, wheezing in the first 2-years, and asthma at ages 5-7-years. Our findings suggest that higher NDVI was associated with fewer viral and M. catarrhalis detections in the first 3-months, while increased PM2.5 and NO2 were linked to earlier symptomatic rhinovirus and H. influenzae detections, respectively. However, no associations were observed with wheezing or asthma. Early-life exposure to air pollution and greenspace may influence early-life respiratory pathogen acquisition and illness. .

11.
Hosp Pediatr ; 14(1): e25-e41, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38161187

RESUMEN

CONTEXT: The risk of invasive device-related thrombosis and bleeding contributes to morbidity and mortality, yet their prevalence by device-types is poorly understood. OBJECTIVES: This study aimed to estimate pooled proportions and rates of thrombotic and bleeding complications associated with invasive devices in pediatric health care. DATA SOURCES: Medline, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched. STUDY SELECTION: Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) pediatric participants admitted to a hospital, (3) reporting thrombotic and bleeding complications, and (4) published in English, were included. DATA EXTRACTION: Meta-analysis of observational studies in epidemiology guidelines for abstracting and assessing data quality and validity were used. MAIN OUTCOMES AND MEASURES: Device-specific pooled thromboses (symptomatic, asymptomatic, unspecified) and bleeding (major, minor). RESULTS: Of the 107 studies, 71 (66%) focused on central venous access devices. Symptomatic venous thromboembolism in central venous access devices was 4% (95% confidence interval [CI], 3-5; incidence rate 0.03 per 1000 device-days, 95% CI, 0.00-0.07), whereas asymptomatic was 10% (95% CI, 7-13; incidence rate 0.25 per 1000 device-days, 95% CI, 0.14-0.36). Both ventricular assist devices (28%; 95% CI, 19-39) and extracorporeal membrane oxygenation (67%; 95% CI, 52-81) were often associated with major bleeding complications. CONCLUSIONS: This comprehensive estimate of the incidence and prevalence of device-related thrombosis and bleeding complications in children can inform clinical decision-making, guide risk assessment, and surveillance.


Asunto(s)
Trombosis , Tromboembolia Venosa , Niño , Humanos , Anticoagulantes , Trombosis/epidemiología , Trombosis/etiología , Hemorragia/epidemiología , Hemorragia/etiología , Hemorragia/terapia , Atención a la Salud
12.
Hosp Pediatr ; 14(1): e42-e56, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38161188

RESUMEN

CONTEXT: Indwelling invasive devices inserted into the body for extended are associated with infections. OBJECTIVE: This study aimed to estimate infection proportion and rates associated with invasive devices in pediatric healthcare. DATA SOURCES: Medline, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched. STUDY SELECTION: Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) pediatric participants admitted to a hospital, (3) postinsertion infection complications, and (4) published in English, were included. DATA EXTRACTION: Meta-analysis of observational studies in epidemiology guidelines for abstracting and assessing data quality and validity were used. MAIN OUTCOMES AND MEASURES: Device local, organ, and bloodstream infection (BSIs) pooled proportion and incidence rate (IR) per-1000-device-days per device type were reported. RESULTS: A total of 116 studies (61 554 devices and 3 632 364 device-days) were included. The highest number of studies were central venous access devices associated BSI (CVAD-BSI), which had a pooled proportion of 8% (95% confidence interval [CI], 6-11; 50 studies) and IR of 0.96 per-1000-device-days (95% CI, 0.78-1.14). This was followed by ventilator-associated pneumonia in respiratory devices, which was 19% (95% CI, 14-24) and IR of 14.08 per-1000-device-days (95%CI, 10.57-17.58). CONCLUSIONS: Although CVAD-BSI and ventilator associated pneumonia are well-documented, there is a scarcity of reporting on tissue and local organ infections. Standard guidelines and compliance initiatives similar to those dedicated to CVADs should be implemented in other devices in the future.


Asunto(s)
Catéteres Venosos Centrales , Sepsis , Niño , Humanos , Incidencia
13.
J Perinat Neonatal Nurs ; 37(4): 332-339, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37878518

RESUMEN

Vascular access devices play vital roles within neonatal care. We aimed to identify neonatal vascular access device insertion and management practices, and describe the incidence and risk factors for complication development. This is a prospective cohort study of neonates requiring vascular access devices over 3 months in an Australian quaternary-referral neonatal intensive care unit. In addition to describing current practices, primary outcomes were device failure, complications, and skin complications. Results are reported using descriptive statistics and with risk factors calculated via Cox proportional hazards regression. A total of 104 neonates required 302 vascular access devices, over 1375 catheter days. Peripheral intravenous catheters (PIVCs) were most used (n = 186; 62%), followed by umbilical venous catheters (n = 52; 17%). Insertion attempts were often undocumented; but for those recorded, 5% of devices (n = 15) required 4 attempts or more. Device failure occurred in 28% (n = 82), at an incidence rate of 62.5 per 1000 catheter days (95% confidence interval [CI] 49.7-75.9). Failure was most frequent in PIVCs (37%; n = 68), peripheral arterial catheters (33%; n = 2), and peripherally inserted central catheters (20%; n = 6). Infiltration and extravasation were the most frequent cause of PIVC failure (12%; n = 35). A birth weight less than 1500 g was associated with a significant decrease in PIVC failure (hazard ratio 0.58; 95% CI 0.34-0.99).


Asunto(s)
Cateterismo Periférico , Recién Nacido , Humanos , Estudios Prospectivos , Australia/epidemiología , Cateterismo Periférico/métodos , Catéteres de Permanencia/efectos adversos , Unidades de Cuidado Intensivo Neonatal , Recién Nacido de muy Bajo Peso
14.
Pediatr Pulmonol ; 58(12): 3428-3436, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37671813

RESUMEN

OBJECTIVE: Airway interactions between viruses, especially rhinoviruses, and potentially pathogenic bacteria (PPB; Streptococcus pneumoniae, Haemophilus influenzae, and Moraxella catarrhalis) in early infancy may increase the risk of subsequent wheezing and asthma. We evaluated the association between rhinovirus and PPB in the first 3 months of life and wheezing episodes before age 2 years and asthma at age 5-7 years. METHODS: An Australian community-based birth cohort of healthy children involved parents collecting nasal swabs weekly and completing symptom diaries daily until age 2 years. In a follow-up subset, asthma diagnosis was assessed annually until age 7 years. Swabs were analyzed by real-time polymerase chain reaction assays. Children were included if they returned symptom diaries beyond age 3 months (wheeze) or were reviewed at age 5-7 years (asthma). RESULTS: 1440 swabs were returned by 146 children in the first 3 months of life. Wheeze and asthma outcomes were recorded for 146 and 84 children, respectively. Each additional week of rhinovirus detection increased the incidence of wheezing before age 2 years by 1.16 times (95% confidence interval [CI]: 0.99-1.35). There were no significant associations between bacteria and wheeze. Each additional week with H. influenzae increased the odds of asthma at age 5-7 years by 135% (odds ratio: 2.35, 95% CI: 0.99-5.58). No significant interaction was observed between rhinovirus and PPB for wheezing or asthma. CONCLUSION: Early life rhinovirus infection was associated with wheezing before age 2 years and H. influenzae with asthma by age 5-7 years. Microbes may play an etiologic role in wheezing and asthma, warranting further study.


Asunto(s)
Asma , Rhinovirus , Niño , Humanos , Lactante , Preescolar , Ruidos Respiratorios/etiología , Australia/epidemiología , Asma/diagnóstico , Bacterias , Haemophilus influenzae
15.
Ther Adv Vaccines Immunother ; 11: 25151355231167116, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37124959

RESUMEN

Children with paediatric rheumatic diseases (PRDs) are at increased risk of vaccine-preventable disease. Safe and effective vaccination is central to preventive care in PRD patients; however, uncertainty surrounding immunogenicity and safety has contributed to suboptimal vaccination. The aim of this study was to evaluate treatment effect on immunogenicity to vaccination in PRD patients and assess vaccine safety, specifically adverse events following immunisation (AEFI) and disease flare. Scoping review. In this scoping review, a systematic search of PubMed, CINAHL and Embase databases was conducted from 2014 to 23 August 2022 to identify observational studies evaluating the immunogenicity and safety of commonly used vaccinations in PRD patients. The primary outcome was immunogenicity (defined as seroprotection and protective antibody concentrations), with secondary outcomes describing AEFI and disease flare also extracted. Due to extensive heterogeneity related to diagnostic and vaccination variability, narrative synthesis was used to describe the findings of each study. Study quality was assessed via the Mixed Methods Appraisal Tool. The review was prospectively registered with PROSPERO (CRD42022307212). The search yielded 19 studies evaluating immunogenicity to vaccination and incidence of AEFI and disease flares in this population, which were of acceptable quality. Corticosteroids did not have deleterious effects on vaccine response. Treatment with conventional disease-modifying antirheumatic drugs (DMARDs) and biologic DMARDs generally had no effect immunogenicity in PRD patients. While patients exhibited adequate seroprotection, protective antibody levels were lower in patients on some immunosuppressant agents. Varicella infections were recorded post vaccination in several patients with low protective antibody levels undergoing treatment with DMARDs and corticosteroids. Most vaccines appear safe and effective in PRD patients, despite immunosuppressant treatment. Booster vaccinations should be considered with some studies highlighting inadequate seroprotection following primary course of vaccinations with acceleration of antibody decline over time. There was limited evidence to support avoiding live vaccines in PRD patients.

16.
Emerg Med Australas ; 35(5): 759-770, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37062587

RESUMEN

OBJECTIVE: This study aimed to (i) capture clinicians' knowledge, attitude and adherence to the first Australian national peripheral intravenous catheter (PIVC) Clinical Care Standard, (ii) examine the instrument performance of the knowledge related questions and (iii) explore the educational needs for, and barriers to, Standard adherence among Australian ED clinicians. METHODS: A cross-sectional national online survey was conducted from March to June 2022, using a snowball sampling method. The survey used 5-point Likert scales and multiple-choice questions to capture respondents' knowledge, attitude and adherence to the Standard as well as the educational needs for, and barriers to, Standard adherence. RESULTS: In total, 433 ED nurses and doctors responded. Although nearly half (n = 206, 47.6%; 95% confidence interval [CI] 55.5-65.8) of respondents claimed that they were unfamiliar with the Standard, questions on PIVC knowledge yielded that most respondents had adequate knowledge of most of the key standards. Respondents' attitudes towards multiple intravenous insertion attempts and ongoing PIVC competency monitoring are not in agreement with the Standard. Self-reported practices regarding routine insertion of idle catheters (55%; 95% CI 49.9-59.9), using antecubital fossa as the first insertion site (84%; 95% CI 80-87), insertion without confidence (46%; 95% CI 41.2-51.1) and lack of routine reviewing the ongoing needs of PIVC (40%; 95% CI 35.3-45.1) were not aligned with the Standard. Unawareness of the Standard and non-practical recommendations were rated as the top barriers to Standard adherence. CONCLUSION: The findings of the survey suggest that the Standard may need modification to align with the needs of ED clinicians. Future studies need to explore the applicability and relevancy of some recommendations in the ED settings as they may cause low adherence to the Standard.


Asunto(s)
Cateterismo Periférico , Conocimientos, Actitudes y Práctica en Salud , Humanos , Estudios Transversales , Nivel de Atención , Australia , Servicio de Urgencia en Hospital , Catéteres
17.
Pediatr Res ; 93(1): 160-167, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35411069

RESUMEN

BACKGROUND: Our study aims to explore the experience of having a central venous access device (CVAD) from the perspective of the child and family and how movements within and outside of hospital environments influence this experience. METHODS: A mixed-methods study was conducted across Children's Health Queensland (Australia), including inpatient and home-care settings. Children less than 18 years with CVADs were eligible and followed for 3 months or CVAD removal. A subgroup of primary caregivers participated in semi-structured interviews. Quantitative and qualitative measures of child and family CVAD experiences were explored. RESULTS: In total, 163 patients with 200 CVADs were recruited and followed for 6993 catheter days (3329 [48%] inpatients; 3147 [45%] outpatients; 517 [7%] home). Seventeen participants were interviewed. Experiences of having a CVAD were complex but predominantly positive primarily related to personalized CVAD care, healthcare quality, and general wellbeing. Their experience was shaped by their movements through hospital and home environments, including care variation and distress with procedures. Device selection and insertion location further influenced experience, including safety, impairments in activities of daily living, school, and recreation. CONCLUSIONS: CVAD experiences were influenced by nonmodifiable (e.g., diagnosis) and modifiable factors (e.g., education; care variation). Clinical approaches and policies that account for family and child considerations should be explored. IMPACT: Variation in decision making and management for pediatric CVADs is accepted by many clinicians, but the influence this variation has on the health experience of children and their families is less well explored. This is the first study to draw from a broad range of children requiring CVADs to determine their experience within and outside of healthcare facilities. Interdisciplinary clinicians and researchers need to work collaboratively with children and their families to provide resources and support services to ensure they have positive experiences with CVADs, no matter where they are managed, or who they are managed by.


Asunto(s)
Cateterismo Venoso Central , Catéteres Venosos Centrales , Servicios de Atención de Salud a Domicilio , Humanos , Niño , Actividades Cotidianas , Australia , Escolaridad
18.
Am J Epidemiol ; 191(12): 2084-2097, 2022 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-35925053

RESUMEN

We estimated the degree to which language used in the high-profile medical/public health/epidemiology literature implied causality using language linking exposures to outcomes and action recommendations; examined disconnects between language and recommendations; identified the most common linking phrases; and estimated how strongly linking phrases imply causality. We searched for and screened 1,170 articles from 18 high-profile journals (65 per journal) published from 2010-2019. Based on written framing and systematic guidance, 3 reviewers rated the degree of causality implied in abstracts and full text for exposure/outcome linking language and action recommendations. Reviewers rated the causal implication of exposure/outcome linking language as none (no causal implication) in 13.8%, weak in 34.2%, moderate in 33.2%, and strong in 18.7% of abstracts. The implied causality of action recommendations was higher than the implied causality of linking sentences for 44.5% or commensurate for 40.3% of articles. The most common linking word in abstracts was "associate" (45.7%). Reviewers' ratings of linking word roots were highly heterogeneous; over half of reviewers rated "association" as having at least some causal implication. This research undercuts the assumption that avoiding "causal" words leads to clarity of interpretation in medical research.


Asunto(s)
Investigación Biomédica , Lenguaje , Humanos , Causalidad
19.
J Hosp Med ; 17(10): 832-842, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36039964

RESUMEN

BACKGROUND: Pediatric extravasation injuries are significant healthcare-associated injuries, with sometimes significant sequelae. Evidence-based guidance on management is necessary to prevent permanent injury. PURPOSE: A systematic review of the literature, including aggregated case series, investigating extravasation injury management of hospitalized pediatric patients. DATA SOURCES: PubMed, Cummulative Index to Nursing and Allied Health Literature (CINAHL), and Excerpta Medica database (EMBASE) were searched on December 13, 2021. STUDY SELECTION: Primary research investigating extravasation injury management of hospitalized pediatric patients (to 18 years), published from 2010 onwards and in English, independently screened by two authors, with arbitration from a third author. DATA EXTRACTION: Data regarding the study, patient (age, primary diagnosis), extravasation (site, presentation, outcome), and treatment (first aid, wound management) were extracted by two authors, with arbitration from a third author. DATA SYNTHESIS: From an initial 1769 articles, 27 studies were included with extractable case data reported in 18 studies, resulting in 33 cases. No clinical trials were identified, instead, studies were primarily case studies (52%) of neonates (67%), with varied extravasation symptoms. Studies had good selection and ascertainment, but few met the causality and reporting requirements for quality assessments. Signs and symptoms varied, with scarring (45%) and necrosis (30%) commonly described. Diverse treatments were categorized into first aid, medical, surgical, and dressings. CONCLUSIONS: Despite infiltration and extravasation injuries being common within pediatric healthcare, management interventions are under-researched, with low-quality studies and no consensus on treatments or outcomes.


Asunto(s)
Extravasación de Materiales Terapéuticos y Diagnósticos , Niño , Extravasación de Materiales Terapéuticos y Diagnósticos/terapia , Humanos , Recién Nacido
20.
J Clin Virol ; 155: 105249, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35939878

RESUMEN

BACKGROUND: Cross-sectional studies report negative associations between rhinovirus and other RNA respiratory viruses. However, longitudinal studies with frequent, serial sampling are needed to identify the directionality of this relationship and its nature. OBJECTIVE: To investigate the association between rhinovirus and other RNA respiratory viruses detected 1-week apart. METHODS: The Observational Research in Childhood Infectious Diseases cohort study was conducted in Brisbane, Australia (2010-2014). Parents collected nasal swabs weekly from birth until age 2-years. Swabs were analysed by real-time polymerase chain reaction. The association between new rhinovirus detections and five other RNA viruses (influenza, respiratory syncytial virus, parainfluenza viruses, seasonal human coronaviruses, and human metapneumovirus) in paired swabs 1-week apart were investigated. RESULTS: Overall, 157 children provided 8,101 swabs, from which 4,672 paired swabs 1-week apart were analysed. New rhinovirus detections were negatively associated with new pooled RNA respiratory virus detections 1-week later (adjusted odds ratio (aOR) 0.48; 95% confidence interval (CI): 0.13-0.83), as were pooled RNA virus detections with new rhinovirus detections the following week (aOR 0.34; 95%CI: 0.09-0.60). At the individual species level, rhinovirus had the strongest negative association with new seasonal human coronavirus detections in the subsequent week (aOR 0.34; 95%CI: 0.120.95) and respiratory syncytial virus had the strongest negative association with rhinovirus 1-week later (aOR 0.21; 95%CI: 0.050.88). CONCLUSION: A strong, negative bidirectional association was observed between rhinovirus and other RNA viruses in a longitudinal study of a community-based cohort of young Australian children. This suggests within-host interference between RNA respiratory viruses.


Asunto(s)
Infecciones por Enterovirus , Virus Sincitial Respiratorio Humano , Infecciones del Sistema Respiratorio , Virus , Australia/epidemiología , Cohorte de Nacimiento , Niño , Preescolar , Estudios de Cohortes , Estudios Transversales , Humanos , Lactante , Estudios Longitudinales , Estudios Prospectivos , ARN , Infecciones del Sistema Respiratorio/epidemiología , Rhinovirus/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA