Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
Eur Heart J Imaging Methods Pract ; 2(1): qyae035, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39045181

RESUMEN

Aims: A comparison of diagnostic performance comparing AI-QCTISCHEMIA, coronary computed tomography angiography using fractional flow reserve (CT-FFR), and physician visual interpretation on the prediction of invasive adenosine FFR have not been evaluated. Furthermore, the coronary plaque characteristics impacting these tests have not been assessed. Methods and results: In a single centre, 43-month retrospective review of 442 patients referred for coronary computed tomography angiography and CT-FFR, 44 patients with CT-FFR had 54 vessels assessed using intracoronary adenosine FFR within 60 days. A comparison of the diagnostic performance among these three techniques for the prediction of FFR ≤ 0.80 was reported. The mean age of the study population was 65 years, 76.9% were male, and the median coronary artery calcium was 654. When analysing the per-vessel ischaemia prediction, AI-QCTISCHEMIA had greater specificity, positive predictive value (PPV), diagnostic accuracy, and area under the curve (AUC) vs. CT-FFR and physician visual interpretation CAD-RADS. The AUC for AI-QCTISCHEMIA was 0.91 vs. 0.76 for CT-FFR and 0.62 for CAD-RADS ≥ 3. Plaque characteristics that were different in false positive vs. true positive cases for AI-QCTISCHEMIA were max stenosis diameter % (54% vs. 67%, P < 0.01); for CT-FFR were maximum stenosis diameter % (40% vs. 65%, P < 0.001), total non-calcified plaque (9% vs. 13%, P < 0.01); and for physician visual interpretation CAD-RADS ≥ 3 were total non-calcified plaque (8% vs. 12%, P < 0.01), lumen volume (681 vs. 510 mm3, P = 0.02), maximum stenosis diameter % (40% vs. 62%, P < 0.001), total plaque (19% vs. 33%, P = 0.002), and total calcified plaque (11% vs. 22%, P = 0.003). Conclusion: Regarding per-vessel prediction of FFR ≤ 0.8, AI-QCTISCHEMIA revealed greater specificity, PPV, accuracy, and AUC vs. CT-FFR and physician visual interpretation CAD-RADS ≥ 3.

4.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38456883

RESUMEN

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Hemodinámica , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
6.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-36882136

RESUMEN

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Masculino , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía
8.
J Am Coll Cardiol ; 79(9): 882-896, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-35241222

RESUMEN

BACKGROUND: The Evolut Low Risk Trial (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients) showed that transcatheter aortic valve replacement (TAVR) with a supra-annular, self-expanding valve was noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke at 2 years. This finding was based on a Bayesian analysis performed after 850 patients had reached 1 year of follow-up. OBJECTIVES: The goal of this study was to report the full 2-year clinical and echocardiographic outcomes for patients enrolled in the Evolut Low Risk Trial. METHODS: A total of 1,414 low-surgical risk patients with severe aortic stenosis were randomized to receive TAVR or surgical AVR. An independent clinical events committee adjudicated adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 730 TAVR and 684 surgical patients from March 2016 to May 2019. The Kaplan-Meier rates for the complete 2-year primary endpoint of death or disabling stroke were 4.3% in the TAVR group and 6.3% in the surgery group (P = 0.084). These rates were comparable to the interim Bayesian rates of 5.3% with TAVR and 6.7% with surgery (difference: -1.4%; 95% Bayesian credible interval: -4.9% to 2.1%). All-cause mortality rates were 3.5% vs 4.4% (P = 0.366), and disabling stroke rates were 1.5% vs 2.7% (P = 0.119), respectively. Between years 1 and 2, there was no convergence of the primary outcome curves. CONCLUSIONS: The complete 2-year follow-up from the Evolut Low Risk Trial found that TAVR is noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke, with event rates that were slightly better than those predicted by using the Bayesian analysis. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients [Evolut Low Risk Trial]; NCT02701283).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Teorema de Bayes , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
9.
J Am Coll Cardiol ; 76(13): 1521-1531, 2020 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-32972528

RESUMEN

BACKGROUND: There is a paucity of data on the burden of in-stent restenosis (ISR) in the United States as well as on its presentation and appropriate treatment strategies. OBJECTIVES: This study aims to provide an analysis of the temporal trends, clinical presentation, treatment strategies, and in-hospital outcomes of patients undergoing percutaneous coronary intervention (PCI) for ISR in the United States. METHODS: This study is a retrospective analysis of data collected in the Diagnostic Catheterization and Percutaneous Coronary Intervention (CathPCI) registry of the National Cardiovascular Data Registry (NCDR) between 2009 and 2017. Of the total patients undergoing PCI, we identified those undergoing PCI for ISR lesions. For comparison of in-hospital outcomes, propensity-score matching was employed. RESULTS: Among the 5,100,394 patients undergoing PCI, 10.6% of patients underwent PCI for ISR lesions. Patients with bare-metal stent ISR declined from 2.6% in 2009 Q3 to 0.9% in 2017 Q2 (p < 0.001), and drug-eluting stent ISR rose from 5.4% in 2009 Q3 to 6.3% in 2017 Q2 (p < 0.001). Patients with ISR PCI were less likely to present with non-ST-segment elevation myocardial infarction (MI) (18.7% vs. 22.5%; p < 0.001) or ST-segment elevation MI (8.5% vs. 15.7%; p < 0.001). In the propensity-matched population of patients, there were no significant differences between patients with ISR and non-ISR PCI for in-hospital complications and hospital length of stay. CONCLUSIONS: ISR represents approximately 10% of all PCI and is treated most commonly with another stent. Approximately 25% of patients present with acute MI. In-hospital outcomes of patients with ISR PCI are comparable with those undergoing non-ISR PCI.


Asunto(s)
Reestenosis Coronaria/epidemiología , Intervención Coronaria Percutánea , Complicaciones Posoperatorias/epidemiología , Sistema de Registros , Anciano , Angiografía Coronaria , Reestenosis Coronaria/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Stents/estadística & datos numéricos , Estados Unidos/epidemiología
10.
Circulation ; 140(23): 1895-1903, 2019 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-31553222

RESUMEN

BACKGROUND: The Absorb everolimus-eluting bioresorbable vascular scaffold (BVS) provides early drug delivery and mechanical support similar to those of metallic drug-eluting stents, followed by complete resorption in ≈3 years with recovery of vascular structure and function. The ABSORB III trial demonstrated noninferior rates of target lesion failure (cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year with BVS compared with cobalt chromium everolimus-eluting stents. Between 1 and 3 years and cumulative to 3 years, adverse event rates (particularly target vessel myocardial infarction and scaffold thrombosis) were increased after BVS. We sought to assess clinical outcomes after BVS through 5 years, including beyond the 3-year time point of complete scaffold resorption. METHODS: Clinical outcomes from ABSORB III were analyzed by randomized device (intention to treat) cumulative to 5 years and between 3 and 5 years. RESULTS: Rates of target lesion failure, target vessel myocardial infarction, and scaffold thrombosis were increased through the 5-year follow-up with BVS compared with everolimus-eluting stents. However, between 3 and 5 years, reductions in the relative hazards of the BVS compared with everolimus-eluting stents were observed, particularly for target lesion failure (hazard ratio, 0.83 [95% CI, 0.55-1.24] versus 1.35 [95% CI, 1.02-1.78]; Pint=0.052) and scaffold thrombosis (hazard ratio, 0.26 [95% CI, 0.02-2.87] versus 3.23 [95% CI, 1.25-8.30]; Pint=0.056) compared with the 0- to 3-year time period. CONCLUSIONS: In the ABSORB III trial, cumulative 5-year adverse event rates were increased after BVS compared with everolimus-eluting stents. However, the period of excess risk for BVS ended at 3 years, coincident with complete scaffold resorption. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov. Unique identifier: NCT01751906.


Asunto(s)
Implantes Absorbibles , Estenosis Coronaria/cirugía , Implantes de Medicamentos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea , Aleaciones de Cromo , Ensayos Clínicos Fase III como Asunto/estadística & datos numéricos , Trombosis Coronaria/epidemiología , Stents Liberadores de Fármacos , Estudios de Equivalencia como Asunto , Everolimus/uso terapéutico , Estudios de Seguimiento , Humanos , Estudios Multicéntricos como Asunto/estadística & datos numéricos , Infarto del Miocardio/epidemiología , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto/estadística & datos numéricos , Método Simple Ciego , Andamios del Tejido , Resultado del Tratamiento
11.
Circ Cardiovasc Interv ; 12(5): e007448, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31084239

RESUMEN

Rotational atherectomy (RA) is an established tool in interventional cardiology for treatment of calcified coronary lesions. Over 3 decades of clinical experience and research, techniques have matured and outcomes have improved. Heterogeneity exists, however, in RA utilization and technique. We assembled a group of experienced RA operators and device experts to summarize and critique key elements of contemporary RA technique, to identify areas of consensus and controversy, and to offer recommendations for optimal performance for the practicing interventional cardiologist. Evolution in RA strategy toward a focus on lesion modification to facilitate balloon angioplasty and stenting has underpinned major advances in procedural safety, including opportunity to use smaller caliber equipment and radial access. Optimal technique and improved safety have permitted exploratory use of RA for different lesion types and reevaluation of procedural requirements, including flush solution composition and transvenous pacing. Preparedness to manage complications remains paramount and recommendations for operators and institutions are outlined.


Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Calcificación Vascular/terapia , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/mortalidad , Aterectomía Coronaria/efectos adversos , Aterectomía Coronaria/instrumentación , Aterectomía Coronaria/mortalidad , Toma de Decisiones Clínicas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Humanos , Selección de Paciente , Factores de Riesgo , Stents , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/mortalidad
12.
N Engl J Med ; 380(18): 1706-1715, 2019 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-30883053

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients. METHODS: We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods. RESULTS: Of the 1468 patients who underwent randomization, an attempted TAVR or surgical procedure was performed in 1403. The patients' mean age was 74 years. The 24-month estimated incidence of the primary end point was 5.3% in the TAVR group and 6.7% in the surgery group (difference, -1.4 percentage points; 95% Bayesian credible interval for difference, -4.9 to 2.1; posterior probability of noninferiority >0.999). At 30 days, patients who had undergone TAVR, as compared with surgery, had a lower incidence of disabling stroke (0.5% vs. 1.7%), bleeding complications (2.4% vs. 7.5%), acute kidney injury (0.9% vs. 2.8%), and atrial fibrillation (7.7% vs. 35.4%) and a higher incidence of moderate or severe aortic regurgitation (3.5% vs. 0.5%) and pacemaker implantation (17.4% vs. 6.1%). At 12 months, patients in the TAVR group had lower aortic-valve gradients than those in the surgery group (8.6 mm Hg vs. 11.2 mm Hg) and larger effective orifice areas (2.3 cm2 vs. 2.0 cm2). CONCLUSIONS: In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Fibrilación Atrial/etiología , Teorema de Bayes , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estimación de Kaplan-Meier , Tiempo de Internación , Masculino , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
14.
JACC Cardiovasc Interv ; 10(23): 2392-2400, 2017 12 11.
Artículo en Inglés | MEDLINE | ID: mdl-29217001

RESUMEN

OBJECTIVES: The authors sought to evaluate the final 5-year safety and effectiveness of the platinum-chromium everolimus-eluting stent (PtCr-EES) in the randomized trial, as well as in 2 single-arm substudies that evaluated PtCr-EES in small vessels (diameter <2.5 mm; n = 94) and long lesions (24 to 34 mm; n = 102). BACKGROUND: In the multicenter, randomized PLATINUM (PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of De Novo Coronary Artery Lesions), the PtCr-EES was noninferior to the cobalt-chromium everolimus-eluting stent (CoCr-EES) at 1 year in 1,530 patients undergoing percutaneous coronary intervention. METHODS: Patients with 1 or 2 de novo coronary artery lesions (reference vessel diameter 2.50 to 4.25 mm, length ≤24 mm) were randomized 1:1 to PtCr-EES versus CoCr-EES. All patients in the substudies received PtCr-EES. The primary endpoint was target lesion failure (TLF), a composite of target vessel-related cardiac death, target vessel-related myocardial infarction, or ischemia-driven target lesion revascularization. RESULTS: In the randomized trial, the 5-year TLF rate was 9.1% for PtCr-EES and 9.3% for CoCr-EES (hazard ratio [HR]: 0.97; p = 0.87). Landmark analysis demonstrated similar TLF rates from discharge to 1 year (HR: 1.12; p = 0.70) and from 1 to 5 years (HR: 0.90; p = 0.63). There were no significant differences in the rates of cardiac death, myocardial infarction, target lesion or vessel revascularization, or stent thrombosis. PtCr-EES had 5-year TLF rates of 7.0% in small vessels and 13.6% in long lesions. CONCLUSIONS: PtCr-EES demonstrated comparable safety and effectiveness to CoCr-EES through 5 years of follow-up, with low rates of stent thrombosis and other adverse events. The 5-year event rates were also acceptable in patients with small vessels and long lesions treated with PtCr-EES. (The PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of De Novo Coronary Artery Lesions [PLATINUM]; NCT00823212; The PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of De Novo Coronary Artery Lesions in Small Vessels [PLATINUM SV]; NCT01498692; The PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of Long De Novo Coronary Artery Lesions [PLATINUM LL]; NCT01500434).


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Aleaciones de Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Platino (Metal) , Anciano , Asia , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Europa (Continente) , Everolimus/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
15.
J Am Coll Cardiol ; 70(23): 2852-2862, 2017 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-29100702

RESUMEN

BACKGROUND: The Absorb everolimus-eluting poly-L-lactic acid-based bioresorbable vascular scaffold (BVS) provides early drug delivery and mechanical support functions similar to metallic drug-eluting stents (DES), followed by complete bioresorption in approximately 3 years with recovery of vascular structure and function. The ABSORB III trial demonstrated noninferior rates of target lesion failure (cardiac death, target vessel myocardial infarction [TVMI], or ischemia-driven target lesion revascularization) at 1 year in 2,008 patients with coronary artery disease randomized to BVS versus cobalt-chromium everolimus-eluting stents (EES). OBJECTIVES: This study sought to assess clinical outcomes through 3 years following BVS implantation. METHODS: Clinical outcomes from the ABSORB III trial were analyzed by randomized treatment assignment cumulative through 3 years, and between 1 and 3 years. RESULTS: The primary composite endpoint of target lesion failure through 3 years occurred in 13.4% of BVS patients and 10.4% of EES patients (p = 0.06), and between 1 and 3 years in 7.0% versus 6.0% of patients, respectively (p = 0.39). TVMI through 3 years was increased with BVS (8.6% vs. 5.9%; p = 0.03), as was device thrombosis (2.3% vs. 0.7%; p = 0.01). In BVS-assigned patients, treatment of very small vessels (those with quantitatively determined reference vessel diameter <2.25 mm) was an independent predictor of 3-year TLF and scaffold thrombosis. CONCLUSIONS: In the ABSORB III trial, 3-year adverse event rates were higher with BVS than EES, particularly TVMI and device thrombosis. Longer-term clinical follow-up is required to determine whether bioresorption of the polymeric scaffold will influence patient prognosis. (ABSORB III Randomized Controlled Trial [RCT] [ABSORB-III]; NCT01751906).


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Inmunosupresores/administración & dosificación , Intervención Coronaria Percutánea , Andamios del Tejido , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Poliésteres , Diseño de Prótesis , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 89(2): 190-198, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26909669

RESUMEN

OBJECTIVE: To examine the influence of smoking on the antiplatelet effect of clopidogrel following percutaneous coronary intervention (PCI). BACKGROUND: Certain studies suggest smokers may have enhanced clopidogrel-induced platelet inhibition compared to non-smokers after PCI. Whether this is affected by clopidogrel dose is unknown. METHODS: In this study, we conducted an analysis of 5,429 patients in the Gauging Responsiveness With A VerifyNow P2Y12 Assay: Impact on Thrombosis and Safety (GRAVITAS) trial. Platelet reactivity was assessed 12-24 hr after PCI (baseline). Patients with high on-treatment platelet reactivity (OTR) (P2Y12 reaction units [PRU] ≥ 230) were randomized to clopidogrel 75 mg or 150 mg daily. Reactivity was subsequently assessed at 30-days, and 6-months. Patients were stratified by smoking status. RESULTS: Smoking was independently associated with lower PRU (P = 0.001), and smokers were less likely to have high OTR (odds ratio 0.80, 95% confidence interval 0.68-0.94; P = 0.006) at baseline. Among patients assigned to clopidogrel 75 mg, smokers had lower PRU and were less likely to still have high OTR at 30-days (P < 0.001) and 6-months (P < 0.001). However, in patients assigned clopidogrel 150 mg, PRU and high OTR did not differ by smoking status at any time. Tests demonstrated an interaction between smoking and dose at 30 days (P = 0.007), and a trend at 6-months (P = 0.098). CONCLUSIONS: Smokers treated with clopidogrel exhibit reduced platelet reactivity and are less likely to have persistent high OTR than non-smokers. This difference is mitigated by clopidogrel 150 mg, indicating non-smokers may require double-dose therapy to achieve a similar antiplatelet effect after PCI. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Plaquetas/efectos de los fármacos , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea , Activación Plaquetaria/efectos de los fármacos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Antagonistas del Receptor Purinérgico P2Y/administración & dosificación , Fumar/efectos adversos , Ticlopidina/análogos & derivados , Anciano , Plaquetas/metabolismo , Distribución de Chi-Cuadrado , Clopidogrel , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico , Relación Dosis-Respuesta a Droga , Stents Liberadores de Fármacos , Femenino , Humanos , Modelos Lineales , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Inhibidores de Agregación Plaquetaria/efectos adversos , Pruebas de Función Plaquetaria , Estudios Prospectivos , Antagonistas del Receptor Purinérgico P2Y/efectos adversos , Receptores Purinérgicos P2Y12/efectos de los fármacos , Receptores Purinérgicos P2Y12/metabolismo , Factores de Riesgo , Fumar/sangre , Ticlopidina/administración & dosificación , Ticlopidina/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 87(4): 703-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26481591

RESUMEN

BACKGROUND: Long-term clinical outcomes after exposure to non-ionic iso-osmolar contrast medium (IOCM) or ionic low-osmolar CM (LOCM) in patients with chronic kidney disease (CKD) undergoing coronary angiography are unclear. METHODS: The ICON trial was a prospective, double-blinded, multicentre study that randomly assigned 146 patients with CKD undergoing coronary angiography with or without percutaneous coronary intervention to the non-ionic IOCM Iodixanol or the ionic LOCM Ioxaglate. We report the 1-year clinical outcomes. RESULTS: After randomization, baseline and procedural characteristics were well-matched between the two groups. At 1 year, three deaths (4.1%) occurred in the ioxaglate and nine deaths in the iodixanol group (13.6%, P = 0.07). The cardiac death rate at 1 year was 2.7% in the ioxaglate group and 9.1% in the iodixanol group (P = 0.07). There were no significant differences in the rates of myocardial infarction (1.4% vs. 1.5%; P = 1.00) and repeated revascularization (6.8% vs. 9.1%; P = 0.75). CONCLUSIONS: The use of ionic LOCM ioxaglate was associated with a numerically lower mortality at 1 year as compared to iodixanol in patients who underwent cardiac catheterization. Future studies evaluating long-term safety following exposure to different types of CM are warranted.


Asunto(s)
Lesión Renal Aguda/inducido químicamente , Angioplastia Coronaria con Balón/efectos adversos , Medios de Contraste/efectos adversos , Angiografía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Ácido Yoxáglico/efectos adversos , Fallo Renal Crónico/complicaciones , Ácidos Triyodobenzoicos/efectos adversos , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/mortalidad , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/mortalidad , Progresión de la Enfermedad , Método Doble Ciego , Femenino , Humanos , Ácido Yoxáglico/análogos & derivados , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/mortalidad , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
18.
N Engl J Med ; 373(20): 1905-15, 2015 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-26457558

RESUMEN

BACKGROUND: In patients with coronary artery disease who receive metallic drug-eluting coronary stents, adverse events such as late target-lesion failure may be related in part to the persistent presence of the metallic stent frame in the coronary-vessel wall. Bioresorbable vascular scaffolds have been developed to attempt to improve long-term outcomes. METHODS: In this large, multicenter, randomized trial, 2008 patients with stable or unstable angina were randomly assigned in a 2:1 ratio to receive an everolimus-eluting bioresorbable vascular (Absorb) scaffold (1322 patients) or an everolimus-eluting cobalt-chromium (Xience) stent (686 patients). The primary end point, which was tested for both noninferiority (margin, 4.5 percentage points for the risk difference) and superiority, was target-lesion failure (cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization) at 1 year. RESULTS: Target-lesion failure at 1 year occurred in 7.8% of patients in the Absorb group and in 6.1% of patients in the Xience group (difference, 1.7 percentage points; 95% confidence interval, -0.5 to 3.9; P=0.007 for noninferiority and P=0.16 for superiority). There was no significant difference between the Absorb group and the Xience group in rates of cardiac death (0.6% and 0.1%, respectively; P=0.29), target-vessel myocardial infarction (6.0% and 4.6%, respectively; P=0.18), or ischemia-driven target-lesion revascularization (3.0% and 2.5%, respectively; P=0.50). Device thrombosis within 1 year occurred in 1.5% of patients in the Absorb group and in 0.7% of patients in the Xience group (P=0.13). CONCLUSIONS: In this large-scale, randomized trial, treatment of noncomplex obstructive coronary artery disease with an everolimus-eluting bioresorbable vascular scaffold, as compared with an everolimus-eluting cobalt-chromium stent, was within the prespecified margin for noninferiority with respect to target-lesion failure at 1 year. (Funded by Abbott Vascular; ABSORB III ClinicalTrials.gov number, NCT01751906.).


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Inmunosupresores/administración & dosificación , Anciano , Angina de Pecho/terapia , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Metales , Persona de Mediana Edad , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA