RESUMEN
OBJECTIVE: To investigate the utility of identifying the superficial circumflex iliac artery (SCIA) via ultrasound as an anatomical landmark for ultrasound-guided femoral nerve block. STUDY DESIGN: Observational study. ANIMALS: A group of six canine cadavers weighing >20 kg. METHODS: Pelvic limbs from six canine cadavers were examined to study the relationship between the SCIA and the femoral nerve. Ultrasonographic imaging of the SCIA in each limb was obtained with the transducer placed transversely in the medial aspect of the pelvic limb at the inguinal area. Subsequently, a needle was inserted in close proximity to the femoral nerve using an in-plane technique based on the anatomical relationship between the SCIA and femoral nerve. A total of 0.1 mL of colored latex was then injected at the location where the femoral nerve was expected to be in relationship to the SCIA. Gross dissection of the inguinal region in each pelvic limb was performed after injection. Positive nerve location was defined when the colored latex was in contact with the femoral nerve. RESULTS: A total of eleven pelvic limbs were injected because the SCIA could not be successfully visualized in one limb. Upon dissection, colored latex was found to be in direct contact with the femoral nerve in all 11 injected limbs. CONCLUSIONS AND CLINICAL RELEVANCE: We concluded that the ultrasonographic visualization of the SCIA assisted in the accurate deposition of dye in proximity to the femoral nerve of canine cadavers. Further investigation will determine the efficacy of this technique for performing femoral nerve blocks.
Asunto(s)
Perros/anatomía & histología , Nervio Femoral/diagnóstico por imagen , Arteria Ilíaca/diagnóstico por imagen , Bloqueo Nervioso/veterinaria , Ultrasonografía Intervencional/veterinaria , Puntos Anatómicos de Referencia/anatomía & histología , Puntos Anatómicos de Referencia/diagnóstico por imagen , Animales , Nervio Femoral/anatomía & histología , Arteria Ilíaca/anatomía & histología , Bloqueo Nervioso/métodos , Ultrasonografía Intervencional/métodosRESUMEN
OBJECTIVE To compare cardiac output (CO) measured by use of CT coronary angiography and thermodilution (criterion-referenced standard) at various CO values, record adverse effects, and determine the time needed to measure CO. ANIMALS 5 healthy purpose-bred Beagles (2 males and 3 females). PROCEDURES A prospective nonrandomized crossover study was conducted. Dogs were premedicated with butorphanol tartrate (0.2 mgâ¢kg-1, IM). Anesthesia was induced by IV administration of etomidate (1 to 2 mgâ¢kg-1) and midazolam (0.25 mgâ¢kg-1). Orotracheal intubation was performed, and anesthesia was maintained by administration of isoflurane. The CO was determined by use of thermodilution and by use of CT at 3 CO values. Dobutamine was infused at various rates to obtain the 3 CO values. RESULTS 13 values were obtained and analyzed. The mean ± SD difference between methods was 0.09 ± 0.71 Lâ¢min-1 (95% confidence interval [CI], 0.52 to -0.34 Lâ¢min-1). Only 1 of 13 values was located on the 100% agreement line (ie, 0 line), 7 of 13 values were located within the 95% CI, and 5 of 13 values were outside the 95% CI. CONCLUSIONS AND CLINICAL RELEVANCE For this study, there was poor agreement between the 2 methods. The 95% CI interval was 0.52 to -0.34 Lâ¢min-1, and 5 of 13 values were outside the 95% CI. Therefore, results for the CT method appeared to be inappropriate for use in making clinical decisions.