Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 28(Pt 6): 1720-1728, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34738925

RESUMEN

Next-generation high-brilliance X-ray photon sources call for new X-ray optics. Here we demonstrate the possibility of using monolithic diamond channel-cut crystals as high-heat-load beam-multiplexing narrow-band mechanically stable X-ray monochromators with high-power X-ray beams at cutting-edge high-repetition-rate X-ray free-electron laser (XFEL) facilities. The diamond channel-cut crystals fabricated and characterized in these studies are designed as two-bounce Bragg reflection monochromators directing 14.4 or 12.4 keV X-rays within a 15 meV bandwidth to 57Fe or 45Sc nuclear resonant scattering experiments, respectively. The crystal design allows out-of-band X-rays transmitted with minimal losses to alternative simultaneous experiments. Only ≲2% of the incident ∼100 W X-ray beam is absorbed in the 50 µm-thick first diamond crystal reflector, ensuring that the monochromator crystal is highly stable. Other X-ray optics applications of diamond channel-cut crystals are anticipated.

2.
J Synchrotron Radiat ; 27(Pt 6): 1553-1563, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33147180

RESUMEN

Wavefront-preserving X-ray diamond crystal optics are essential for numerous applications in X-ray science. Perfect crystals with flat Bragg planes are a prerequisite for wavefront preservation in Bragg diffraction. However, this condition is difficult to realize in practice because of inevitable crystal imperfections. Here, X-ray rocking curve imaging is used to study the smallest achievable Bragg-plane slope errors in the best presently available synthetic diamond crystals and how they compare with those of perfect silicon crystals. It is shown that the smallest specific slope errors in the best diamond crystals are about 0.08 (3) µrad mm-2. These errors are only 50% larger than the 0.05 (2) µrad mm-2 specific slope errors measured in perfect silicon crystals. High-temperature annealing at 1450°C of almost flawless diamond crystals reduces the slope errors very close to those of silicon. Further investigations are in progress to establish the wavefront-preservation properties of these crystals.

3.
J Synchrotron Radiat ; 26(Pt 4): 1069-1072, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31274429

RESUMEN

Self-amplified spontaneous emission (SASE) enables X-ray free-electron lasers (XFELs) to generate hard X-ray pulses of sub-100 fs duration. However, due to the stochastic nature of SASE, the energy spectrum fluctuates from pulse to pulse. Many experiments that employ XFEL radiation require the resolution of the spectrum of each pulse. The work presented here investigates the capacity of a thin strongly bent diamond crystal to resolve the energy spectra of hard X-ray SASE pulses by studying its diffraction properties. Rocking curves of the symmetric C*(440) reflection have been measured for different bending radii. The experimental data match the theoretical modelling based on the Takagi-Taupin equations of dynamical diffraction. A uniform strain gradient has proven to be a valid model of strain deformations in the crystal.

4.
J Synchrotron Radiat ; 26(Pt 4): 1101-1109, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31274433

RESUMEN

A wake monochromator based on a large-area diamond single crystal for hard X-ray self-seeding has been successfully installed and commissioned in the hard X-ray free-electron laser (FEL) at the Pohang Accelerator Laboratory with international collaboration. For this commissioning, the self-seeding was demonstrated with a low bunch charge (40 pC) and the nominal bunch charge (180 pC) of self-amplified spontaneous emission (SASE) operation. The FEL pulse lengths were estimated as 7 fs and 29.5 fs, respectively. In both cases, the average spectral brightness increased by more than three times compared with the SASE mode. The self-seeding experiment was demonstrated for the first time using a crystal with a thickness of 30 µm, and a narrow bandwidth of 0.22 eV (full width at half-maximum) was obtained at 8.3 keV, which confirmed the functionality of a crystal with such a small thickness. In the nominal bunch-charge self-seeding experiment, the histogram of the intensity integrated over a 1 eV bandwidth showed a well defined Gaussian profile, which is evidence of the saturated FEL and a minimal electron-energy jitter (∼1.2 × 10-4) effect. The corresponding low photon-energy jitter (∼2.4 × 10-4) of the SASE FEL pulse, which is two times lower than the Pierce parameter, enabled the seeding power to be maximized by maintaining the spectral overlap between SASE FEL gain and the monochromator.

5.
J Synchrotron Radiat ; 25(Pt 4): 1022-1029, 2018 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-29979163

RESUMEN

X-ray free-electron lasers in the oscillator configuration (XFELO) are future fully coherent hard X-rays sources with ultrahigh spectral purity. X-ray beams circulate in an XFELO optical cavity comprising diamond single crystals. They function as high-reflectance (close to 100%), narrowband (∼10 meV) Bragg backscattering mirrors. The average power density of the X-ray beams in the XFELO cavity is predicted to be as high as ∼10 kW mm-2. Therefore, XFELO feasibility relies on the ability of diamond crystals to withstand such a high radiation load and preserve their high reflectivity. Here the endurance of diamond crystals to irradiation with multi-kW mm-2 power density X-ray beams is studied. It is shown that the high Bragg reflectivity of the diamond crystals is preserved after the irradiation, provided it is performed at ∼1 × 10-8 Torr high-vacuum conditions. Irradiation under 4 × 10-6 Torr results in a ∼1 meV shift of the Bragg peak, which corresponds to a relative lattice distortion of 4 × 10-8, while the high Bragg reflectivity stays intact.

6.
Opt Express ; 25(21): 25090-25097, 2017 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-29041180

RESUMEN

Quality of a refractive compound X-ray lens can be limited by imperfections in surfaces of unit lenses and stacking precision. In general case both the lens transmission and optical aberrations define properties of a beam in the lens exit plane; together they can be expressed in terms of the generalized pupil function. In this work we measure this function for a diamond single crystal compound refractive lens. Consequently, we apply the pupil function to evaluate the performance of the examined compound refractive X-ray lens. A number of practically important conclusions can be drawn from such analysis.

7.
Opt Express ; 25(3): 2852-2862, 2017 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-29519002

RESUMEN

A precise spectral characterization of every single pulse is required in many x-ray free-electron laser (XFEL) experiments due to the fluctuating spectral content of self-amplified spontaneous emission (SASE) beams. Bent single-crystal spectrometers can provide sufficient spectral resolution to resolve the SASE spikes while also covering the full SASE bandwidth. To better withstand the high heat load induced by the 4.5 MHz repetition rate of pulses at the forthcoming European XFEL facility, a spectrometer based on single-crystal diamond has been developed. We report a direct comparison of the diamond spectrometer with its Si counterpart in experiments performed at the Linac Coherent Light Source.

8.
J Synchrotron Radiat ; 24(Pt 1): 103-109, 2017 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-28009551

RESUMEN

Linear parabolic diamond refractive lenses are presented, designed to withstand high thermal and radiation loads coming from upgraded accelerator X-ray sources. Lenses were manufactured by picosecond laser treatment of a high-quality single-crystal synthetic diamond. Twelve lenses with radius of curvature at parabola apex R = 200 µm, geometrical aperture A = 900 µm and length L = 1.5 mm were stacked as a compound refractive lens and tested at the ESRF ID06 beamline. A focal spot of size 2.2 µm and a gain of 20 were measured at 8 keV. The lens profile and surface quality were estimated by grating interferometry and X-ray radiography. In addition, the influence of X-ray glitches on the focusing properties of the compound refractive lens were studied.

9.
Rev Sci Instrum ; 87(12): 125117, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28040980

RESUMEN

We report on the manufacturing and X-ray tests of bent diamond-crystal X-ray spectrographs, designed for noninvasive diagnostics of the X-ray free-electron laser (XFEL) spectra in the spectral range from 5 to 15 keV. The key component is a curved, 20-µm thin, single crystalline diamond triangular plate in the (110) orientation. The radius of curvature can be varied between R = 0.6 m and R = 0.1 m in a controlled fashion, ensuring imaging in a spectral window of up to 60 eV for ≃8 keV X-rays. All of the components of the bending mechanism (about 10 parts) are manufactured from diamond, thus ensuring safe operations in intense XFEL beams. The spectrograph is transparent to 88% for 5-keV photons and to 98% for 15-keV photons. Therefore, it can be used for noninvasive diagnostics of the X-ray spectra during XFEL operations.


Asunto(s)
Diamante , Rayos Láser , Modelos Teóricos , Difracción de Rayos X/métodos , Rayos X
10.
Rev Sci Instrum ; 85(6): 063106, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24985798

RESUMEN

A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressure High-Temperature grown type-IIa diamond crystal plates with the (111) orientation. The first crystal has a thickness of ~100 µm to allow high reflectivity within the Bragg bandwidth and good transmission for the other wavelengths for downstream use. The second crystal is about 300 µm thick and makes the exit beam of the monochromator parallel to the incoming beam with an offset of 600 mm. Here we present details on the monochromator design and its performance.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA