Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Eur J Neurol ; 23(5): 906-11, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26843095

RESUMEN

BACKGROUND AND PURPOSE: Based on a tight network of stroke units (SUs) and interventional centres, endovascular treatment of acute major intracranial vessel occlusion has been widely implemented in Austria. Documentation of all patients in the nationwide SU registry has thereby become mandatory. METHODS: Demographic, clinical and interventional characteristics of patients who underwent endovascular treatment for acute ischaemic stroke in 11 Austrian interventional centres between 1 October 2013 and 30 September 2014 were analysed. RESULTS: In total, 301 patients (50.5% women; median age 70.5 years; median National Institutes of Health Stroke Scale score 17) were identified.193 patients (64.1%) additionally received intravenous thrombolysis. The most frequent vessel occlusion sites were the M1 segment of the middle cerebral artery (n = 161, 53.5%), the intracranial internal carotid artery (n = 60, 19.9%) and the basilar artery (n = 40, 13.3%). Stent retrievers were used in 235 patients (78.1%) and adequate reperfusion (modified Thrombolysis in Cerebral Infarction scores 2b and 3, median onset to reperfusion time 254 min) was achieved in 242 patients (81.4%). Symptomatic intracranial haemorrhage occurred in 7%. 43.8% of patients (n = 132) had good functional outcome (modified Rankin Scale score 0-2) and the mortality rate was 20.9% (n = 63) after 3 months. Compared to the anterior circulation, vertebrobasilar stroke patients had higher mortality. Patients with secondary hospital transportation had better outcomes after 3 months than in-house treated patients. CONCLUSION: Our results document nationwide favourable outcome and safety rates of endovascular stroke treatment comparable to recent randomized trials. The ability to provide such data and the need to further optimize such an approach also underscore the contribution of respective registries.


Asunto(s)
Isquemia Encefálica/terapia , Procedimientos Endovasculares/métodos , Accidente Cerebrovascular/terapia , Trombectomía/métodos , Terapia Trombolítica/métodos , Administración Intravenosa , Anciano , Austria , Isquemia Encefálica/tratamiento farmacológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Stents , Accidente Cerebrovascular/tratamiento farmacológico , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Estados Unidos
2.
Radiologe ; 55(10): 833-9, 2015 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-26377920

RESUMEN

BACKGROUND: Minimally invasive procedures have played an emerging role in pain management during recent years. OBJECTIVES: Evaluation of the different types of periradicular infiltration as fundamental procedures in the progressive stepwise concept of pain management. Comparison of the different therapeutic substances. RESULTS: In the mid-term and long-term periradicular infiltration is effective in 60-80 % of patients regarding analgesic and functional aspects. Compliance with the guidelines should help to minimize potentially fatal complications. CONCLUSION: Periradicular infiltration is of significant importance concerning the treatment of spinal nerve root irritation. Periradicular infiltration is regarded as a safe procedure, especially when supported by computed tomography (CT) scans.


Asunto(s)
Anestesia Local/métodos , Anestésicos Locales/administración & dosificación , Dolor de Espalda/prevención & control , Manejo del Dolor/métodos , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X/métodos , Medicina Basada en la Evidencia , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Resultado del Tratamiento
4.
Radiology ; 221(2): 437-46, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11687688

RESUMEN

PURPOSE: To evaluate the safety and performance of a recently developed expanded polytetrafluoroethylene (ePTFE)-covered nitinol stent-graft to create transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension and related complications. MATERIALS AND METHODS: The ePTFE-covered nitinol stent-graft was used to create TIPS in 16 patients with recurrent variceal bleeding (n = 13) or refractory ascites (n = 3). Follow-up was performed with duplex ultrasonography, clinical assessment, and venography at 6 months. Technical success and portosystemic pressure gradients (PPGs) before and after stent-graft implantation and at follow-up were assessed. Two patients died during follow-up. Histopathologic follow-up data were available for one patient at autopsy and for the other after liver transplantation. RESULTS: The implantation technical success rate was 100%. Mean (+/- SD) PPG was reduced from 24 mm Hg +/- 5 to 9 mm Hg +/- 2. Histopathologic analysis of the explanted endoprostheses revealed no inflammatory response or neointima formation. The venographic follow-up data available for 10 patients demonstrated 100% in-graft patency (mean follow-up, 289 days +/- 26). Revisions with implantation of a new ePTFE-covered nitinol stent-graft or another commercially available stent in 10 patients were necessary because of hepatic vein stenosis above the grafted portion and/or relative diameter mismatch causing TIPS dysfunction. CONCLUSION: The ePTFE-covered nitinol stent-graft was used successfully to create TIPS and has the potential to prolong TIPS patency upon complete coverage to the hepatocaval junction.


Asunto(s)
Aleaciones , Hipertensión Portal/cirugía , Politetrafluoroetileno , Derivación Portosistémica Intrahepática Transyugular , Stents , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Derivación Portosistémica Intrahepática Transyugular/efectos adversos , Prótesis e Implantes , Diseño de Prótesis
5.
Eur Radiol ; 11(11): 2252-7, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11702168

RESUMEN

The aim of this study was to determine the role of the inferior mesenteric artery (IMA) as an outflow vessel in endoleaks after abdominal aortic stent-graft implantation. Forty consecutive patients in whom abdominal aortic aneurysms (AAA) had been treated with stent-graft implantation were evaluated retrospectively. Spiral-CT examinations and angiographies up to 36 months after implantation were analyzed. In 29 (73%) of the 40 patients the IMA was perfused prior to implantation. In 5 (17%) of these 29 cases, the artery remained perfused after stent-graft insertion. In all 5 cases, endoleaks were detected; however, in none of these cases was the IMA the sole cause. In 3 of these 5 cases, angiography showed antegrade flow in the IMA. Implantation of extension stent grafts caused thrombosis of the aneurysmal sac and the IMA. There were no secondary endoleaks caused by the IMA at the 36-month follow-up examinations. The majority of IMAs which are patent prior to intervention occlude after successful stent-graft insertion. In cases with leaks and angiographically proven antegrade flow in the IMA, implantation of extension stent grafts is a therapeutic alternative to embolization. In this study, the IMA was not responsible for secondary endoleaks.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Arteria Mesentérica Inferior/diagnóstico por imagen , Arteria Mesentérica Inferior/fisiopatología , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/fisiopatología , Falla de Prótesis , Stents , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Flujo Sanguíneo Regional , Factores de Tiempo , Tomografía Computarizada por Rayos X/métodos
6.
AJR Am J Roentgenol ; 177(6): 1365-9, 2001 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11717084

RESUMEN

OBJECTIVE: The purpose of our study was to investigate the clinical experience and efficiency of translumenl endovascular stent-graft insertion using commercially available vascular endoprotheses. We studied seven patients with descending aortic dissection (type B) and four patients with penetrating aortic ulcer over a median follow-up period of 254 days during the years 1997-2000, using cross-sectional CT to evaluate the extent of the dissection, the distance between the entry tear and the left subclavian artery, and the diameter of the true lumen and the false lumen. CONCLUSION: Endovascular treatment of acute and chronic aortic type B dissections and penetrating ulcer is a minimally invasive method with a low complication rate that could be considered a feasible alternative to surgical repair. Depending on the length of the dissection, we recommend the placement of two overlapping stent-grafts in the thoracic aorta to stabilize the affected thoracic aorta over a longer distance. This might provide a reliable sealing of the entry tear and should prevent further communication between the true lumen and the false lumen.


Asunto(s)
Angioscopía , Aneurisma de la Aorta Torácica/cirugía , Enfermedades de la Aorta/cirugía , Disección Aórtica/cirugía , Prótesis Vascular , Stents , Úlcera/cirugía , Anciano , Disección Aórtica/clasificación , Aorta Torácica , Aneurisma de la Aorta Torácica/clasificación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
7.
Rofo ; 173(10): 924-30, 2001 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-11588681

RESUMEN

UNLABELLED: Simon nitinol vena cava filters: effectiveness and complications. PURPOSE: The aim of this retrospective analysis was to evaluate the clinical safety and effectiveness of the Simon Nitinol inferior vena cava filter (SNF) for prevention of pulmonary embolism. PATIENTS AND METHODS: 117 patients (63 male, 54 female; aged 58.38 +/- 14.59 years) underwent percutaneous implantation of an SNF from 1993 through 1999. Patient reports were retrospectively analysed for complications during and after implantation and deep venous thrombosis (DVT) and pulmonary embolism before and after implantation. Helical-CT with contrast media and plain abdominal radiography were performed on 35 patients, helical-CT alone on two patients. We checked the position and configuration of the SNF and looked for a perforation of the filter legs through the wall of the inferior vena cava (IVC). The IVC and deep pelvic veins were analysed for patency. RESULTS: During implantation 10 of 117 (9 %) patients had minor complications, major complications were reported in 0.9 % (1/117). There was no significant increase in thrombosis of the deep pelvic veins and the IVC after implantation. Pulmonary re-embolism (PE) was documented in 9 out of 117 patients (7.7 %). One out of the 35 examined patients (2.9 %) showed a single strut fracture of the SNF. Tilting more than 15 degrees was seen in 7 out of 37 patients (19 %). Dislocation of the SNF more than 10 mm occurred in one out of 35 patients (2.9 %), perforation through the wall of the IVC in all 37 patients. We found no occlusion of the IVC. CONCLUSION: The SNF is easy and safe to implant and successfully prevents pulmonary embolism. In our study the rate of well documented pulmonary re-embolism (7.7 %) is satisfactory. Except for the high perforation rate through the wall of the IVC (100 %, but without clinical relevance), complication rates during and after implantation of the SNF are low compared with other filter types.


Asunto(s)
Aleaciones , Embolia Pulmonar/prevención & control , Filtros de Vena Cava , Adulto , Anciano , Falla de Equipo , Seguridad de Equipos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X
8.
AJR Am J Roentgenol ; 177(3): 599-605, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11517053

RESUMEN

OBJECTIVE: The aim of our study was to assess the frequency, efficacy, and incidence of adverse effects of internal iliac artery embolization. MATERIALS AND METHODS: Of 343 patients examined for stent-graft repair, 147 were suitable for endovascular treatment. Fifty-five patients underwent preprocedural embolization of the internal iliac artery either unilaterally (46 patients) or bilaterally (nine patients). Successful embolization was assessed angiographically and with helical CT follow-up examinations. Colonic ischemia was ruled out clinically or colonoscopically. Buttock claudication, and sexual dysfunction in men, were evaluated through a questionnaire. RESULTS: Embolization of the internal iliac artery increased by 16% the percentage of patients for whom endovascular repair was suitable. After successful embolization in all patients, routine CT follow-up examinations after a mean time of 16.7 months showed no evidence of endoleaks related to retrograde perfusion via embolized internal iliac arteries. Nevertheless, in all patients who had undergone embolization, a primary endoleak was detected in 43.4% at the first postoperative CT examination. None of our patients had evidence of colonic ischemia. Clinical follow-up data of 46 patients were available. Of these patients, mild to severe new onset buttock claudication was found in 13 (36.1%) of 36 patients with unilateral, and in eight (80%) of 10 patients with bilateral, internal iliac artery embolization (p = 0.03). Five (25%) of 20 men had an erectile dysfunction after the procedure. CONCLUSION: Embolization of the internal iliac artery is a safe and efficient procedure that increases the applicability for endovascular repair of aortoiliac aneurysms. However, buttock claudication and erectile dysfunction are a drawback in a substantial number of patients.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Embolización Terapéutica , Arteria Ilíaca , Cuidados Preoperatorios , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía , Nalgas/irrigación sanguínea , Embolización Terapéutica/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Arteria Ilíaca/diagnóstico por imagen , Claudicación Intermitente/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
9.
Eur Radiol ; 11(6): 922-5, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11419163

RESUMEN

A case of peripancreatic fat necrosis, after an episode of acute pancreatitis, which mimicked pancreatic cancer with lymph node metastases, is presented. We describe the imaging findings with helical CT scanning and with unenhanced and mangafodipir-enhanced MR imaging, with special emphasis on the differential diagnoses.


Asunto(s)
Necrosis Grasa/diagnóstico , Imagen por Resonancia Magnética , Enfermedades Pancreáticas/diagnóstico , Neoplasias Pancreáticas/diagnóstico , Tomografía Computarizada por Rayos X , Adulto , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Páncreas/patología , Pancreatitis Aguda Necrotizante/diagnóstico
10.
Radiology ; 219(1): 137-46, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11274548

RESUMEN

PURPOSE: To evaluate the safety and effectiveness of gadodiamide-enhanced magnetic resonance (MR) angiography with single and triple doses in the assessment of abdominal arterial stenoses. MATERIALS AND METHODS: One hundred five patients were included in the randomized, double-blind, phase III multicenter trial. Results of MR angiography with 0.1 mmol/kg and 0.3 mmol/kg doses of gadodiamide were compared with those of digital subtraction angiography (DSA) and according to dose. RESULTS: No serious adverse events were observed. The mean contrast index at the region proximal to the primary stenosis was significantly higher in the triple-dose group (P =.03). Mean 95% CI values for the difference in depicted degree of stenosis between DSA and postcontrast MR angiography improved from -3.4% +/- 4.7 (SD) in the single-dose group to -1.2% +/- 4.7 in the triple-dose group. Mean values for overall image quality on the visual analogue scale improved with the triple dose (P =.02). Confidence in diagnosis was high at postcontrast MR angiography in 88% and 96% of cases in the single- and triple-dose groups, respectively. CONCLUSION: Gadodiamide-enhanced MR angiography performed with single and triple doses is safe and effective for assessing major abdominal arterial stenoses. Although high agreement between MR angiography and DSA was achieved with both doses, triple-dose MR angiography was superior in the evaluations of image quality, degree of arterial stenoses, and confidence in diagnosis.


Asunto(s)
Abdomen/irrigación sanguínea , Arteriopatías Oclusivas/diagnóstico , Medios de Contraste/administración & dosificación , Gadolinio DTPA , Aumento de la Imagen , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Medios de Contraste/efectos adversos , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Femenino , Gadolinio DTPA/administración & dosificación , Gadolinio DTPA/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
11.
J Vasc Surg ; 33(2 Suppl): S46-54, 2001 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11174812

RESUMEN

PURPOSE: Endograft technology for abdominal aortic aneurysm (AAA) repair is being applied more liberally. There is little information about the midterm performance of these grafts. This study is focused on follow-up interventions after endograft repair for AAA. METHODS: Prospective follow-up analysis of a consecutive patient series (n = 173 patients) at a single center who underwent endovascular AAA repair up to 50 months after operation. Seventeen percent of the patients were regarded unfit for open surgery. Four types of commercially available grafts were used. The Society for Vascular Surgery/International Society for Cardiovascular Surgery guidelines were applied for endograft implantation and data preparation. RESULTS: In two patients, the procedure was converted to open surgery. In one procedure, emergency repair for iliac artery rupture was performed. The 30-day mortality rate was 2.8% (n = 5 patients). An early second procedure to correct type I endoleaks was necessary in 8 cases (4.6%; 3-10 days). The following midterm results were obtained: median follow-up of the 166 remaining patients was 18 months (range, 1-50 months); 50 additional procedures were necessary in 37 patients (22.3%) for the treatment of leaks (n = 45 interventions) or to maintain graft patency (n = 5 grafts; four patients with concomitant graft segment disconnection); and 46% of the reinterventions were performed within the first year of follow-up and 74% of the reinterventions were performed within the second year of follow-up. One patient died after emergency surgery for rupture as the result of a secondary endoleak at 1 year. Although seven interventions (14%) were performed for type II endoleak, no serious complications were related to patent sidebranches. There was no statistically significant difference between the need for maintenance in different graft configurations (tubular, bifurcated, aorto-uniiliac), or number of graft segments (1, 2, 3-4, > or = 5 segments). New generation grafts (after 1996) performed better than early generation grafts (P = 0.04, chi-squared test) with regard to endoleak development. CONCLUSION: Endograft repair for AAA is safe but, with current technology, not as durable as open repair. Our data suggest that the use of endograft repair for AAA is becoming safer as endograft design improves. Nevertheless in 26.6% of the patients, there is need for reintervention within midterm follow-up. Close follow-up is crucial because late leaks may develop after more than 2 years after the initial procedure. Endoluminal repair should therefore be applied with caution, strict indication, and only if a tight follow-up is warranted. These findings may also affect health care reimbursement policies.


Asunto(s)
Angioplastia/métodos , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/métodos , Anciano , Anciano de 80 o más Años , Angioplastia/efectos adversos , Angioplastia/instrumentación , Angioplastia/mortalidad , Aneurisma de la Aorta Abdominal/clasificación , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Rotura de la Aorta/etiología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Falla de Prótesis , Radiografía , Reoperación , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Grado de Desobstrucción Vascular
12.
J Vasc Interv Radiol ; 12(1): 23-31, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11200349

RESUMEN

PURPOSE: To evaluate if stent placement is superior to percutaneous transluminal angioplasty (PTA) in the treatment of chronic symptoms in short femoropopliteal arterial lesions. MATERIALS AND METHODS: One hundred fifty-four limbs in 141 patients who ranged in age from 39 to 87 years (mean age, 67 years) were randomized to PTA (n = 77) versus PTA followed by implantation of Palmaz stents (n = 77). Inclusion criteria were patients with intermittent claudication (n = 108, Society of Vascular Surgery/International Society of Cardiovascular Surgery [SVS-ISCVS] categories 1-3) or chronic critical limb ischemia (n = 46 with either ischemic rest pain [category 4] or minor tissue loss [category 5]), short stenosis or occlusion (lesion length < or = 5 cm), and at least one patent run-off vessel at angiography. Follow-up included clinical assessment, measurement of ankle/ brachial index (ABI), color duplex ultrasound, and/or angiography at 6 or 12 months. Angiographic follow-up between 12 and 36 months was available in 46 limbs (29.9%). RESULTS: In the PTA group, initial technical success was achieved in 65 of 77 limbs (84%) versus 76 of 77 (99%) limbs in the stent group (chi2 value = 0.009). Overall, major complications occurred in 3.9% (n = 6); n = 4 in the PTA group compared to n = 2 in the stent group. There was no difference between groups of treatment: hemodynamic/clinical success at 1 and 2 years in the PTA group was 72% and 65% versus 77% and 65% in the stent group (Gehan P value = .26). The cumulative 1- and 2-year angiographic primary patency rates were 63% and 53%, respectively, for both groups. The secondary 1- and 2-year angiographic patency rates were 86% and 74% in the PTA group versus 79% and 73% in the stent group (P = .5). CONCLUSION: After stent placement, the primary success rate was significantly higher than after PTA. However, 1-year angiographic and clinical/hemodynamic success was not improved.


Asunto(s)
Angioplastia de Balón , Claudicación Intermitente/terapia , Isquemia/terapia , Pierna/irrigación sanguínea , Stents , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Arteria Femoral , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Arteria Poplítea , Complicaciones Posoperatorias , Estudios Prospectivos , Resultado del Tratamiento
13.
Artículo en Alemán | MEDLINE | ID: mdl-11824295

RESUMEN

All patients (n = 826) treated electively at the Department of Vascular Surgery University of Vienna, Austria, for their AAA during the years 1965-2000 were analysed with particular emphasis on endoluminal repair. Data collection was carried out in retrospect. The operative mortality or within 30 days was considered the primary endpoint of the study. Since 1995 the TEAM approach was available. From that point in time 45.5% of the AAA were treated electively in the endoluminal way. An exploratory analysis of the clinical series revealed a statistically significant difference in the incidence of various risk factors between groups in favor of open repair. Consequently a conditional regression analysis demonstrated the operative method, median patient's age (above versus below 72 years of age), reduced renal and/or pulmonary function to be of significant influence.


Asunto(s)
Angioplastia de Balón , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Factores de Riesgo , Tasa de Supervivencia
14.
Radiologe ; 40(9): 798-804, 2000 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-11056971

RESUMEN

Percutaneous transluminal angioplasty and stenting of carotid artery stenosis represents an innovative experimental modality which has been increasingly employed in high-risk patients. Currently, results from prospective randomized trials are not available; thus, guidelines with regard to indications and technique are preliminary. Numerous technical innovations to avoid associated complications have evolved in neurointerventional procedures. Dedicated guiding catheters and stents using a transfemoral approach have been introduced for treatment of carotid artery disease. Low-profile stent delivery systems may decrease risk of releasing embolic load when crossing high-grade stenosis or kinking of the vessel. The introduction of a cerebral protection with the use of temporary occlusion balloons or filter systems has resulted in a reduction of procedure-related neurological complications, and is strongly recommended by leading experts in the field.


Asunto(s)
Angioplastia de Balón/métodos , Estenosis Carotídea/terapia , Stents , Arterias Carótidas/diagnóstico por imagen , Arterias Carótidas/patología , Estenosis Carotídea/diagnóstico , Cateterismo Periférico/métodos , Humanos , Angiografía por Resonancia Magnética , Selección de Paciente , Punciones/métodos , Radiografía Intervencional
15.
Semin Interv Cardiol ; 5(1): 53-7, 2000 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10875224

RESUMEN

The standard technique for the treatment of descending thoracic aortic aneurysms is elective open surgical repair with graft interposition. This standard approach, although steadily improving, is associated with high morbidity and substantial mortality rates and implies a major surgical procedure with lateral thoracotomy, use of cardiopulmonary bypass, long operation times and a variety of peri- and postoperative complications. This and the success of the first endoluminal treatment of abdominal aortic aneurysms by Parodi et al. prompted the attention to be thrown on the treatment of descending thoracic aortic aneurysms with endoluminal stent-grafts in many large centres. The aim of this new minimally invasive technique is to exclude the aneurysm from blood flow and in consequence to avoid pressure stress on the aneurysmatic aortic wall, by avoiding a large open operation with significant perioperative morbidity. The potentially beneficial effect of this new treatment approach was evaluated in the course of this study.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular , Procedimientos Quirúrgicos Mínimamente Invasivos , Adulto , Anciano , Anciano de 80 o más Años , Aleaciones , Angiografía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Implantación de Prótesis Vascular/instrumentación , Cateterismo , Materiales Biocompatibles Revestidos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Politetrafluoroetileno , Diseño de Prótesis , Estudios Retrospectivos , Stents , Tomografía Computarizada por Rayos X
16.
Eur Radiol ; 10(5): 725-32, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10823623

RESUMEN

The aim of this study was to determine the potential of contrast-enhanced magnetic resonance (MR) angiography in the evaluation of peripheral bypass grafts. Digital subtraction angiography (DSA) served as a standard of reference. Thirty-five patients with previous bypass graft surgery underwent DSA and contrast-enhanced MR angiography within 2 weeks. MR angiography was performed using a three-dimensional fast gradient-echo sequence after administration of gadopentetate dimeglumine. Every leg was divided into 11 segments and scored in five categories of stenosis. MR angiography findings were compared with those of DSA. A total of 38 bypass grafts and 454 segments in 27 patients were included in the evaluation. In 33 (87%) bypass grafts stenosis grading with both methods corresponded, and in 5 (13%) cases stenosis was overestimated on MR angiography. Agreement in detection of hemodynamically significant stenosis (stenosis =50%) was 94.7% with a sensitivity of 100% and a specificity of 91.3%. In 340 (83.0%) vascular segments there was conformity in graduation, in 69 (16.88%), there was a difference of one or more grades on MR angiograms. Forty-four segments (9.6%) were not assessable due to technical limitations. Contrast-enhanced MR angiography is an useful noninvasive tool in the detection of failing peripheral vascular bypass grafts.


Asunto(s)
Prótesis Vascular , Medios de Contraste , Pierna/irrigación sanguínea , Angiografía por Resonancia Magnética , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Constricción Patológica/diagnóstico , Femenino , Arteria Femoral/patología , Gadolinio DTPA , Oclusión de Injerto Vascular/diagnóstico , Hemodinámica/fisiología , Humanos , Arteria Ilíaca/patología , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Enfermedades Vasculares Periféricas/cirugía , Arteria Poplítea/patología , Estudios Retrospectivos , Sensibilidad y Especificidad , Grado de Desobstrucción Vascular
17.
AJNR Am J Neuroradiol ; 21(4): 670-8, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10782776

RESUMEN

BACKGROUND AND PURPOSE: Recent studies have reported the clinical improvement in patients with AIDS treated with a combination of antiretroviral regimens. The purpose of our study was to describe the effects of highly active antiretroviral therapy on MR images in patients with HIV encephalopathy and to compare the clinical course with follow-up neuroimaging studies. METHODS: Initial and follow-up MR imaging findings are described in four patients with AIDS dementia complex at baseline and after antiretroviral therapy, and correlated with clinical and immunologic findings. RESULTS: Initial MR imaging revealed white matter signal abnormalities on long-TR images without mass effect and without enhancement on postcontrast images, consistent with HIV encephalopathy. Lesions were located in the basal ganglia and posterior fossa in two patients. All four patients showed progression of white matter disease on the first follow-up MR scan (mean, 6 months). On subsequent scans, regression was seen in three patients and stabilization of white matter disease was observed in one patient. Increases in CD4+ count and decreases in viral load below the limit of quantification were present in all patients. CONCLUSION: Although our patient population was small, the results suggest that disease regression in patients with AIDS dementia complex after treatment with highly active antiretroviral therapy can be characterized and monitored by MR imaging.


Asunto(s)
Complejo SIDA Demencia/tratamiento farmacológico , Complejo SIDA Demencia/patología , Fármacos Anti-VIH/uso terapéutico , Imagen por Resonancia Magnética , Complejo SIDA Demencia/inmunología , Complejo SIDA Demencia/fisiopatología , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
18.
Ann Thorac Surg ; 69(2): 441-5, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10735678

RESUMEN

BACKGROUND: This study was performed to evaluate the safety and feasibility of endovascular stent graft placement in the treatment of descending thoracic aortic aneurysms. METHODS: Between November 1996 and February 1999, endovascular stent graft repair was used in 21 patients. There were 5 women and 16 men with a mean age of 67 years (range, 41 to 87 years). An atherosclerotic aneurysm with a diameter of more than 6 cm was the indication for intervention in 19 patients (90.5%). In 2 patients (9.5%), a localized aortic dissection with a diameter of more than 6 cm was treated. In 71.4% (15 of 21) of patients, multiple stents were necessary for aneurysm exclusion. To allow safe deployment of the stent graft, preliminary subclavian-carotid artery transposition was performed in 9 patients (42.9%). Vascular access was achieved through a small incision in the abdominal aorta (n = 6), an iliac artery (n = 8), or a femoral artery (n = 7). Talent and Prograft stent grafts were used. RESULTS: Successful deployment of the endovascular stent grafts was achieved in all patients. Two patients died postoperatively (mortality rate, 9.5%), 1 of aneurysmal rupture and the other of impaired perfusion of the celiac axis. Repeat stenting was done in 3 patients because of intraoperative leakage. CONCLUSIONS: Endovascular stent graft repair is a promising and less invasive alternative to exclude the aneurysm from blood flow. This technique allows treatment of patients who are unsuitable for conventional surgical procedures. An exact definition of inclusion criteria and technical development of stent grafts should contribute to further improvements in clinical results.


Asunto(s)
Aneurisma de la Aorta Torácica/terapia , Rotura de la Aorta/terapia , Stents , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Resultado del Tratamiento
19.
Cardiovasc Intervent Radiol ; 22(6): 468-74, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10556405

RESUMEN

PURPOSE: To assess, in a multicenter setting, safety, technical results, and restenosis rate of the Palmaz stent for treatment of atherosclerotic ostial renal artery stenosis. METHODS: Ten centers enrolled 106 patients (120 treated renal artery stenoses) in the study. Patient selection was based on unsuccessful percutaneous transluminal renal angioplasty (residual stenosis >/= 20%) performed for treatment of ostial stenosis >/= 50%, in patients with hypertension and/or impaired renal function. Safety was assessed by means of the complication rate, and technical results by the number of successful stent placements and occurrence of restenosis (>50%) at intraarterial angiographic follow-up. RESULTS: Stent placement was successful (n = 112) or partially successful (n = 5) in 117 (98%) arteries. Complications occurred in 19 procedures; seven were of serious clinical significance. Angiographic follow-up was performed in 89 of 117 (76%) cases, at a mean of 8 months (range 2. 5-18 months). Fifteen stents (16.9%) showed restenosis (at a mean of 8.5 months), of which 10 were successfully redilated. CONCLUSION: Renal artery stenting has a high technical success rate, a complication rate comparable to percutaneous transluminal renal angioplasty, and a low rate of restenosis at 8 months angiographic follow-up.


Asunto(s)
Arteriosclerosis/terapia , Obstrucción de la Arteria Renal/terapia , Stents , Anciano , Angioplastia de Balón , Femenino , Humanos , Masculino , Estudios Prospectivos , Radiografía , Recurrencia , Arteria Renal/diagnóstico por imagen , Seguridad , Stents/efectos adversos
20.
Cardiovasc Intervent Radiol ; 22(4): 305-10, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10415220

RESUMEN

PURPOSE: To investigate whether placement of a polyester-covered stent-graft increases the primary patency of transjugular intrahepatic portosystemic stent shunts (TIPSS). METHODS: Between 1995 and 1997 Cragg Endopro or Passager MIBS stent-grafts were used for the creation of TIPSS in eight male patients, 35-59 years of age (mean 48 years). All patients suffered from recurrent variceal bleeding and/or refractory ascites due to liver cirrhosis. Seven stent-grafts were dilated to a diameter of 10 mm, one to 12 mm. Follow-up was performed with duplex ultrasound, clinical assessment, and angiography. RESULTS: The technical success rate for creation of a TIPSS was 100%. The mean portosystemic pressure gradient decreased from 25 mmHg to 12 mmHg. In seven of eight patients TIPSS dysfunction occurred between 2 days and 3 years after stent-graft placement. In one patient the TIPSS is still primarily patent (224 days after creation). The secondary patency rates are 31 days to 3 years. CONCLUSION: The primary use of polyester-covered stent-grafts for TIPSS did not increase primary patency rates in our small series.


Asunto(s)
Materiales Biocompatibles Revestidos , Hemorragia Gastrointestinal/cirugía , Poliésteres , Derivación Portosistémica Intrahepática Transyugular/métodos , Stents , Adulto , Biopsia , Velocidad del Flujo Sanguíneo , Várices Esofágicas y Gástricas/complicaciones , Várices Esofágicas y Gástricas/diagnóstico , Várices Esofágicas y Gástricas/fisiopatología , Estudios de Seguimiento , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Humanos , Cirrosis Hepática/complicaciones , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/fisiopatología , Masculino , Persona de Mediana Edad , Flebografía , Proyectos Piloto , Vena Porta/diagnóstico por imagen , Vena Porta/fisiopatología , Complicaciones Posoperatorias , Estudios Retrospectivos , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA