Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Nanoscale ; 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39254475

RESUMEN

Hormones are chemical messengers that regulate a wide range of physiological processes including metabolism, development, growth, reproduction and mood. The concentration of hormones that orchestrate the numerous bodily functions is very low (1 nM or less). Efforts have been made to develop highly sensitive tools to detect them. This review represents a critical comparison between different types of nanoparticle-based electrochemical biosensors for the detection of various hormones, namely cortisol, sex hormones (estradiol, progesterone, testosterone), insulin, thyroid-stimulating hormone (TSH) and growth hormone (GH). The electrochemical biosensors investigated for each hormone are first divided on the basis of the biological fluid tested for their detection, and successively on the basis of the electrochemical transducer utilized in the device (voltammetric or impedimetric). Focus is placed on the nanoparticles employed and the successive electrode modification developed in order to improve detection sensitivity and specificity and biosensor stability. Limit of detection (LOD), linear range, reproducibility and possibility of regeneration for continuous reuse are also investigated and compared. The review also addresses the recent trends in the development of wearable biosensors and point-of-care testing for hormone detection in clinical diagnostics useful for endocrinology research, and the future perspectives regarding the integration of nanomaterials, microfluidics, near field communication (NFC) technology and portable devices.

2.
Bioelectrochemistry ; 156: 108590, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37976772

RESUMEN

This work describes the development of a novel voltammetric immunosensor for the detection of salivary MMP-8 at the point-of-care. The electrochemical platform was based on a graphene (GPH) screen-printed electrode (SPE) functionalized by gold-nanospheres (AuNSs) and antibodies against MMP-8 protein (anti-MMP-8). The functionalization with anti-MMP-8 was realized by using 11-mercaptoundecanoic acid (11-MUA), thanks to its ability to give strong sulfur bonds with its -SH end, and to cross-link the -NH2 groups of the antibody molecule with the other -COOH end, using the traditional EDC-NHS method. The voltammetric sensor showed good performances with a linear range of 2.5-300 ng mL-1, a LOD value of 1.0 ± 0.1 ng mL-1 and a sensitivity of 0.05 µA mL cm-2 ng-1. Moreover, the proposed immunosensor was tested in real saliva samples, showing comparable results to those obtained with the conventional ELISA method. The biosensor was single-use and cost-effective and required a small quantity of test medium and a short preparation time, representing a very attractive biosensor for MMP-8 detection in human saliva.


Asunto(s)
Técnicas Biosensibles , Periodontitis , Humanos , Metaloproteinasa 8 de la Matriz , Inmunoensayo , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Límite de Detección , Biomarcadores , Periodontitis/diagnóstico , Electrodos , Oro
3.
Sensors (Basel) ; 23(22)2023 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-38005597

RESUMEN

This paper describes the development of a simple voltammetric biosensor for the stereoselective discrimination of myo-inositol (myo-Ins) and D-chiro-inositol (D-chiro-Ins) by means of bovine serum albumin (BSA) adsorption onto a multi-walled carbon nanotube (MWCNT) graphite screen-printed electrode (MWCNT-GSPE), previously functionalized by the electropolymerization of methylene blue (MB). After a morphological characterization, the enantioselective biosensor platform was electrochemically characterized after each modification step by differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The results show that the binding affinity between myo-Ins and BSA was higher than that between D-chiro-Ins and BSA, confirming the different interactions exhibited by the novel BSA/MB/MWCNT/GSPE platform towards the two diastereoisomers. The biosensor showed a linear response towards both stereoisomers in the range of 2-100 µM, with LODs of 0.5 and 1 µM for myo-Ins and D-chiro-Ins, respectively. Moreover, a stereoselectivity coefficient α of 1.6 was found, with association constants of 0.90 and 0.79, for the two stereoisomers, respectively. Lastly, the proposed biosensor allowed for the determination of the stereoisomeric composition of myo-/D-chiro-Ins mixtures in commercial pharmaceutical preparations, and thus, it is expected to be successfully applied in the chiral analysis of pharmaceuticals and illicit drugs of forensic interest.


Asunto(s)
Inositol , Azul de Metileno , Estereoisomerismo
4.
ACS Biomater Sci Eng ; 9(6): 3597-3605, 2023 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-37192401

RESUMEN

Chitosan and lignin mixed nanoparticles were prepared by layer-by-layer and nanoprecipitation methodologies as responsive platforms for sustainable biosensors. The novel nanoparticles showed effective chemophysical and electrochemical properties dependent on the preparation methodology, molecular weight of chitosan, and type of lignin. HOMO-LUMO energy gap calculations suggested the presence of structure-activity relationships between the electrochemical responsiveness and the order and orientation of lignin aromatic subunits and chitosan chains in the nanodevices.


Asunto(s)
Quitosano , Nanopartículas , Lignina/química , Nanopartículas/química , Relación Estructura-Actividad
5.
Electroanalysis ; 2022 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-36247366

RESUMEN

Here, a novel biosensing platform for the detection of SARS-CoV-2 usable both at voltammetric and impedimetric mode is reported. The platform was constructed on a multi-walled carbon nanotubes (MWCNTs) screen-printed electrode (SPE) functionalized by methylene blue (MB), antibodies against SARS-CoV-2 spike protein (SP), a bioactive layer of chitosan (CS) and protein A (PrA). The voltammetric sensor showed superior performances both in phosphate buffer solution (PBS) and spiked-saliva samples, with LOD values of 5.0±0.1 and 30±2.1 ng/mL, compared to 20±1.8 and 50±2.5 ng/mL for the impedimetric sensor. Moreover, the voltammetric immunosensor was tested in real saliva, showing promising results.

6.
Biosensors (Basel) ; 12(7)2022 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-35884322

RESUMEN

The regulation of nervous and cardiovascular systems and some brain-related behaviors, such as stress, panic, anxiety, and depression, are strictly dependent on the levels of the main catecholamines of clinical interest, dopamine (DA), epinephrine (EP), and norepinephrine (NEP). Therefore, there is an urgent need for a reliable sensing device able to accurately monitor them in biological fluids for early diagnosis of the diseases related to their abnormal levels. In this paper, we present the first tyrosinase (Tyr)-based biosensor based on chitosan nanoparticles (ChitNPs) for total catecholamine (CA) detection in human urine samples. ChitNPs were synthetized according to an ionic gelation process and successively characterized by SEM and EDX techniques. The screen-printed graphene electrode was prepared by a two-step drop-casting method of: (i) ChitNPS; and (ii) Tyr enzyme. Optimization of the electrochemical platform was performed in terms of the loading method of Tyr on ChitNPs (nanoprecipitation and layer-by-layer), enzyme concentration, and enzyme immobilization with and without 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) and N-hydroxysuccinimide (NHS) as cross-linking agents. The Tyr/EDC-NHS/ChitNPs nanocomposite showed good conductivity and biocompatibility with Tyr enzyme, as evidenced by its high biocatalytic activity toward the oxidation of DA, EP, and NEP to the relative o-quinone derivatives electrochemically reduced at the modified electrode. The resulting Tyr/EDC-NHS/ChitNPs-based biosensor performs interference-free total catecholamine detection, expressed as a DA concentration, with a very low LOD of 0.17 µM, an excellent sensitivity of 0.583 µA µM-1 cm-2, good stability, and a fast response time (3 s). The performance of the biosensor was successively assessed in human urine samples, showing satisfactory results and, thus, demonstrating the feasibility of the proposed biosensor for analyzing total CA in physiological samples.


Asunto(s)
Técnicas Biosensibles , Quitosano , Nanopartículas , Técnicas Biosensibles/métodos , Catecolaminas , Quitosano/química , Técnicas Electroquímicas/métodos , Electrodos , Humanos , Monofenol Monooxigenasa , Nanopartículas/química
7.
Mikrochim Acta ; 189(5): 180, 2022 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-35391571

RESUMEN

Dopamine (DA), epinephrine (EP), and norepinephrine (NEP) are the main catecholamine of clinical interest, as they play crucial roles in the regulation of nervous and cardiovascular systems and are involved in some brain behaviors, such as stress, panic, anxiety, and depression. Therefore, there is an urgent need for a reliable sensing device able to provide their continuous monitoring in a minimally invasive manner. In this work, the first highly nanoporous gold (h-nPG) microneedle-based sensor is presented for continuous monitoring of catecholamine in interstitial fluid (ISF). The h-nPG microneedle-based gold electrode was prepared by a simple electrochemical self-templating method that involves two steps, gold electrodeposition and hydrogen bubbling at the electrode surface, realized by sweeping the potential between + 0.8 V and 0 V vs Ag/AgCl for 25 scans in a 10 mM HAuCl4 solution containing 2.5 M NH4Cl, and successively applying a fixed potential of - 2 V vs Ag/AgCl for 60 s. The resulting microneedle-based h-nPG sensor displays an interference-free total catecholamine detection expressed as NEP concentration, with a very low LOD of 100 nM, excellent sensitivity and stability, and fast response time (< 4 s). The performance of the h-nPG microneedle array sensor was successively assessed in artificial ISF and in a hydrogel skin model at typical physiological concentrations.


Asunto(s)
Oro , Nanoporos , Catecolaminas , Electrodos , Agujas
8.
Biosensors (Basel) ; 13(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36671877

RESUMEN

In this work, we report on the development of a simple electrochemical immunosensor for the detection of D-dimer protein in human plasma samples. The immunosensor is built by a simple drop-casting procedure of chitosan nanoparticles (CSNPs) as biocompatible support, Protein A (PrA), to facilitate the proper orientation of the antibody sites to epitopes as a capture biomolecule, and the D-dimer antibody onto a carboxyl functionalized multi-walled carbon nanotubes screen printed electrode (MWCNTs-SPE). The CSNPs have been morphologically characterized by Scanning Electron Microscopy (SEM) and Dynamic Light Scattering (DLS) techniques. Successively, the electrochemical properties of the screen-printed working electrode after each modification step have been characterized by differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The resulting MWCNTs-CSNPs-PrA-D-dimer Ab immunosensor displays an optimal and promising platform for antibody immobilization and specific D-dimer detection. DPV has been used to investigate the antigen/antibody interaction at different D-dimer concentrations. The proposed voltammetric immunosensor allowed a linear range from 2 to 500 µg L-1 with a LOD of 0.6 µg L-1 and a sensitivity of 1.3 µA L µg-1 cm-2. Good stability and a fast response time (5 s) have been reported. Lastly, the performance of the voltammetric immunosensor has been tested in human plasma samples, showing satisfactory results, thus attesting to the promising feasibility of the proposed platform for detecting D-dimer in physiological samples.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Quitosano , Nanopartículas del Metal , Nanotubos de Carbono , Humanos , Técnicas Biosensibles/métodos , Nanotubos de Carbono/química , Inmunoensayo , COVID-19/diagnóstico , Biomarcadores , Pronóstico , Anticuerpos , Nanopartículas del Metal/química , Electrodos , Quitosano/química , Técnicas Electroquímicas , Límite de Detección , Oro/química
9.
Nanomaterials (Basel) ; 11(3)2021 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-33809211

RESUMEN

Novel nanoarchitectures based on lignin nanoparticles (LNPs) were designed and realized for electrochemical eco-friendly biosensing development. Two types of lignin nanoparticles were utilized for the modification of a gold bare electrode, namely organosolv (OLNPs) and kraft lignin (KLNPs) nanoparticles, synthetized from a sulfur-free and a sulfur lignin, respectively. The electrochemical behavior of LNP-modified electrodes was studied using two electrochemical techniques, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Compared to the gold bare electrode, an evident decrease in the faradaic current and increase of the ΔEp were observed in cyclic voltammograms. In addition, larger semicircles were registered in Nyquist plots. These results suggest a strong inhibition effect of the electron transfer reaction by LNPs layer, especially in the case of KLNPs. The modified electrodes, properly assembled with concanavalin A (ConA) and glucose oxidase (GOx), were successively tested as biosensing platforms for glucose, showing a sensitivity of (4.53 ± 0.467) and (13.74 ± 1.84) µA mM-1 cm2 for Au/SAMCys/OLNPs/ConA/GOx and Au/KLNPs/ConA/GOx biosensors, respectively. Finally, different layers of the KNLPs/ConA/GOx-modified Au electrode were tested, and the three-layered Au(KNLPs/ConA/GOx)3 showed the best analytical performance.

10.
Nat Prod Res ; 33(7): 1015-1025, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27771968

RESUMEN

Traditional cleaning methods with organic solvents often are not suitable for removal of aged resin so researchers have to find new formulations. In this work, a case study is reported in which new microemulsions were applied on the surface of a painting covered by some aged resin layers used during a previous restoration. Based on the quality of the intervention and the analysis of a sample of the varnish carried out with both MALDI-TOF and ATR-IR spectrometers, it was conjectured that this undesired material could be an acrylic polymer. So it was chosen to use xylene, ethyl acetate and propylene carbonate (XYL and EAPC) microemulsions (O/W oil in water). The first is able to solubilise only acrylic polymers, the second may solve both acrylic and vinyl resins. The first has had the greatest effect allowing complete varnish removal and original artwork restoration.


Asunto(s)
Resinas Acrílicas/aislamiento & purificación , Emulsiones/farmacología , Pinturas , Resinas Sintéticas/aislamiento & purificación , Solventes/química , Arte , Pintura/análisis , Polímeros/química , Refractometría , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Tensoactivos
11.
Biosensors (Basel) ; 8(4)2018 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-30441783

RESUMEN

A single-use electrochemical screen-printed electrode is reported based on biomimetic properties of nanoceria particles (CeNPs). The developed tool showed an easy approach compared to the classical spectrophotometric methods reported in literature in terms of ease of use, cost, portability, and unnecessary secondary reagents. The sensor allowed the detection of the total antioxidant capacity (TAC) in wine samples. The sensor has been optimized and characterized electrochemically and then tested with antioxidant compounds occurred in wine samples. The electrochemical CeNPs modified sensor has been used for detection of TAC in white and red commercial wines and the data compared to the 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulphonic acid (ABTS)-based spectrophotometric method. Finally, the obtained results have demonstrated that the proposed sensor was suitable for the simple and quick evaluation of TAC in beverage samples.


Asunto(s)
Antioxidantes/química , Electroquímica/métodos , Nanopartículas del Metal/química , Espectrofotometría , Vino
12.
Methods Mol Biol ; 1694: 75-80, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29080157

RESUMEN

In this work a detailed description of the development of amine oxidase-based electrochemical biosensors for the selective determination of the biogenic amines is presented. The enzymes required for this operation are Polyamine Oxidase (PAO) and Spermine Oxidase (SMO) which are physically entrapped in poly(vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ), a photo-cross-linkable gel, onto screen printed electrode (SPE) surface. The developed biosensors are deeply characterized in the analysis of biogenic amines by using flow injection amperometric (FIA) technique. The enzymatic electrodes are characterized by good sensitivity, long-term stability, and reproducibility. To test the feasibility of the developed biosensors in the analysis of real matrices, they are used for the analysis of blood samples. The results obtained are in good agreement with those obtained with the GC-MS reference method.


Asunto(s)
Técnicas Biosensibles , Oxidorreductasas actuantes sobre Donantes de Grupo CH-NH/química , Espermidina/análisis , Espermina/análisis , Aminas Biogénicas/análisis , Electrodos , Poliamino Oxidasa
13.
Methods Mol Biol ; 1572: 41-53, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28299680

RESUMEN

Electrochemical biosensors provide an attractive means of analyzing the content of a biological sample due to the direct conversion of a biological event to an electronic signal. The signal transduction and the general performance of electrochemical biosensors are often determined by the surface architectures that connect the sensing element to the biological sample at the nanometer scale. The most common surface modification techniques, the various electrochemical transduction mechanisms, and the choice of the recognition receptor molecules all influence the ultimate sensitivity of the sensor. We show herein a novel electrochemical biosensing platform based on the coupling of two different nanostructured materials (gold nanoparticles and fullerenols) displaying interesting electrochemical features. The use of these nanomaterials improved the electrochemical performance of the proposed biosensor.An application of the nanostructured enzyme-based biosensor has been developed for evaluating the detection of polyphenols either in buffer solution or in real wine samples.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Enzimas , Fulerenos , Oro , Nanopartículas del Metal , Polifenoles/análisis , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Calibración , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Electrodos , Enzimas/química , Diseño de Equipo , Fulerenos/química , Ácido Gálico/análisis , Oro/química , Lacasa/análisis , Nanopartículas del Metal/química , Nanopartículas del Metal/ultraestructura , Vino/análisis
14.
Biosens Bioelectron ; 89(Pt 1): 152-166, 2017 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-27132999

RESUMEN

Graphene's success has stimulated great interest and research in the synthesis and characterization of graphene-like 2D materials, single and few-atom-thick layers of van der Waals materials, which show fascinating and technologically useful properties. This review presents an overview of recent electrochemical sensors and biosensors based on graphene and on graphene-like 2D materials for biomarkers detection. Initially, we will outline different electrochemical sensors and biosensors based on chemically derived graphene, including graphene oxide and reduced graphene oxide, properly functionalized for improved performances and we will discuss the various strategies to prepare graphene modified electrodes. Successively, we present electrochemical sensors and biosensors based on graphene-like 2D materials, such as boron nitride (BN), graphite-carbon nitride (g-C3N4), transition metal dichalcogenides (TMDs), transition metal oxides and graphane, outlining how the new modified 2D nanomaterials will improve the electrochemical performances. Finally, we will compare the results obtained with different sensors and biosensors for the detection of important biomarkers such as glucose, hydrogen peroxide and cancer biomarkers and highlight the advantages and disadvantages of the use of graphene and graphene-like 2D materials in different sensing platforms.


Asunto(s)
Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Grafito/química , Nanoestructuras/química , Animales , Biomarcadores/análisis , Técnicas Biosensibles/instrumentación , Compuestos de Boro/química , Técnicas Electroquímicas/instrumentación , Humanos , Metales/química , Nanoestructuras/ultraestructura , Elementos de Transición/química
15.
Biosens Bioelectron ; 93: 52-56, 2017 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-27743865

RESUMEN

In this work, we developed an impedimetric label-free immunosensor for the detection of 2,4-Dichlorophenoxy Acetic Acid (2,4-D) herbicide either in standard solution and spiked real samples. For this purpose, we prepared by electropolymerization a conductive polymer poly-(aniline-co-3-aminobenzoic acid) (PANABA) then we immobilized anti-2,4-D antibody onto a nanocomposite AuNPs-PANABA-MWCNTs employing the carboxylic moieties as anchor sites. The nanocomposite was synthesized by electrochemical polymerization of aniline and 3-aminobenzoic acid, in the presence of a dispersion of gold nanoparticles, onto a multi-walled carbon nanotubes-based screen printed electrode. Aniline-based copolymer, modified with the nanomaterials, allowed to enhance the electrode conductivity thus obtaining a more sensitive antigen detection. The impedimetric measurements were carried out by electrochemical impedance spectroscopy (EIS) in faradic condition by using Fe(CN)63-/4- as redox probe. The developed impedimetric immunosensor displayed a wide linearity range towards 2,4-D (1-100ppb), good repeatability (RSD 6%), stability and a LOD (0.3ppb) lower than herbicide emission limits.


Asunto(s)
Ácido 2,4-Diclorofenoxiacético/aislamiento & purificación , Técnicas Biosensibles , Técnicas Electroquímicas , Ácido 2,4-Diclorofenoxiacético/química , Compuestos de Anilina/química , Espectroscopía Dieléctrica , Electrodos , Oro/química , Límite de Detección , Nanopartículas del Metal/química , Nanotubos de Carbono/química , Polímeros/química
16.
Anal Bioanal Chem ; 408(12): 3203-11, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26874693

RESUMEN

In this work, several theoretical aspects involved in the first-generation inhibition-based electrochemical biosensor measurements have been discussed. In particular, we have developed a theoretical-methodological approach for the characterization of the kinetic interaction between alkaline phosphatase (AlP) and 2,4-dichlorophenoxy acetic acid (2,4-D) as representative inhibitor studied by means of cyclic voltammetry and amperometry. Based on these findings, a biosensor for the fast, simple, and inexpensive determination of 2,4-D has been developed. The enzyme has been immobilized on screen-printed electrodes (SPEs). To optimize the biosensor performances, several carbon-based SPEs, namely graphite (G), graphene (GP), and multiwalled carbon nanotubes (MWCNTs), have been evaluated. AlP was immobilized on the electrode surface by means of polyvinyl alcohol with styryl-pyridinium groups (PVA-SbQ) as cross-linking agent. In the presence of ascorbate 2-phosphate (A2P) as substrate, the herbicide has been determined, thanks to its inhibition activity towards the enzyme catalyzing the oxidation of A2P to ascorbic acid (AA). Under optimum experimental conditions, the best performance in terms of catalytic efficiency has been demonstrated by MWCNTs SPE-based biosensor. The inhibition biosensor shows a linearity range towards 2,4-D within 2.1-110 ppb, a LOD of 1 ppb, and acceptable repeatability and stability. This analysis method was applied to fortified lake water samples with recoveries above 90%. The low cost of this device and its good analytical performances suggest its application for the screening and monitoring of 2,4-D in real matrices.


Asunto(s)
Ácido 2,4-Diclorofenoxiacético/análisis , Técnicas Biosensibles , Técnicas Electroquímicas/métodos , Cinética
17.
J Anal Methods Chem ; 2016: 8174913, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28078163

RESUMEN

A catalase-based (NAF/MWCNTs) nanocomposite film modified glassy carbon electrode for hydrogen peroxide (H2O2) detection was developed. The developed biosensor was characterized in terms of its bioelectrochemical properties. Cyclic voltammetry (CV) technique was employed to study the redox features of the enzyme in the absence and in the presence of nanomaterials dispersed in Nafion® polymeric solution. The electron transfer coefficient, α, and the electron transfer rate constant, ks , were found to be 0.42 and 1.71 s-1, at pH 7.0, respectively. Subsequently, the same modification steps were applied to mesoporous graphite screen-printed electrodes. Also, these electrodes were characterized in terms of their main electrochemical and kinetic parameters. The biosensor performances improved considerably after modification with nanomaterials. Moreover, the association of Nafion with carbon nanotubes retained the biological activity of the redox protein. The enzyme electrode response was linear in the range 2.5-1150 µmol L-1, with LOD of 0.83 µmol L-1. From the experimental data, we can assess the possibility of using the modified biosensor as a useful tool for H2O2 determination in packaged beverages.

18.
J Nanosci Nanotechnol ; 15(5): 3423-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-26504961

RESUMEN

Nafion, an ion exchange polymer that is very resistant to chemical attack, even by strong oxidant at high temperatures, has found great increasing use as a film material; however, its use as immobilizing agent in third-generation biosensors is hindered due to the low rate of charge transfer in the pure Nafion film. In this work we showed that the use of functionalized multi-walled carbon nanotubes Nafion/MWCNTs composite film for modification of the carbon-based electrode surfaces would increase the charge transfer rate greatly; the composite has proven to efficiently immobilize two different heme proteins (catalase and cytochrome c) and to enhance the electrochemical performances of several carbon electrode materials (glassy carbon, mesoporous graphite, graphite and graphene) either used as classical electrodes or screen printed ones. The electrochemical signal of both redox proteins becomes more reversible and the electron transfer kinetic constant increases. At the same time the biological activity is maintained indicating that the immobilization procedure allows the proteins to retain a native-like structure.


Asunto(s)
Técnicas Biosensibles/instrumentación , Carbono/química , Proteínas Inmovilizadas/química , Nanocompuestos/química , Animales , Catalasa/química , Bovinos , Citocromos c/química , Electrones , Polímeros de Fluorocarbono/química , Ensayo de Materiales
19.
Biosens Bioelectron ; 67: 524-31, 2015 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-25263314

RESUMEN

In this work we have developed a new electrochemical DNA-based biosensor for the selective determination of the Hg(2+) ion by the use of different electrodes modified with polythymine, bearing methylene blue, as redox probe, in 3' position. The determination of Hg(2+) can be employed with an excellent degree of selectivity by the use of DNA biosensors through the formation of the complex Thymine-Hg-Thymine (T-Hg-T): in fact, Hg(2+) tends to bind two thymines, generating a T-Hg-T complex with a formation constant higher than that one of the coupling Adenine-Thymine, which can be employed for a selective, fast and cost-effective Hg(2+) detection. The presence of the Hg(2+) in solution leads to the formation of T-Hg-T complex thus causing the "hairpin-like" folding of oligonucleotide, leading to an improved electronic exchange of methylene blue with the electrode surface due to the reduced distance and thus to an increase of the faradic current which is detected by means of square wave voltammetry (SWV). To test the feasibility of this kind of biosensor to be applied to the analysis of Hg(2+) we have developed several biosensors configuration by modifying the electrochemical sensor transducer: (a) Au electrode; (b) Au screen-printed electrode (SPE). The proposed system, allows the determination of Hg(2+) in the range 0.2-100 nM (0.05-20 ppb), with a sensitivity 0.327 µA/nM, LOD 0.1 nM (0.02 ppb), LOQ 0.2 nM (0.05 ppb) and RSD ≤4.3% when Au electrode is used as electrochemical transducer; on the other hand, in the case of Au SPE the linear range is 0.2-50 nM (0.05-10 ppb), with a sensitivity 0.285 µA/nM, while LOD and LOQ are the same as previously and RSD is ≤3.8%. This enabled the detection of mercury in real samples (waters and fishes) with good accuracy (recoveries 92-101% on waters and 92-107% on fishes, respectively) and reproducibility (RSD ≤9.6% for measurements on waters and ≤8.8% on fishes, respectively).


Asunto(s)
Técnicas Biosensibles , ADN/química , Mercurio/aislamiento & purificación , Animales , Peces/sangre , Oro/química , Límite de Detección , Mercurio/química , Agua/análisis
20.
Anal Bioanal Chem ; 407(4): 1131-7, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25407429

RESUMEN

The present work describes the development and optimization of electrochemical biosensors for specific determination of the biogenic polyamine spermine (Spm) and spermidine (Spmd) whose assessment represents a novel important analytical tool in food analysis and human diagnostics. These biosensors have been prepared using novel engineered enzymes: polyamine oxidase (PAO) endowed with selectivity towards Spm and Spmd and spermine oxidase (SMO) characterized by strict specificity towards Spm. The current design entails biosensors in which the enzymes were entrapped in poly(vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ), a photocrosslinkable gel, onto an electrode surface. Screen-printed electrodes (SPEs) were used as electrochemical transducers for enzymatically produced hydrogen peroxide, operating at different potential vs Ag/AgCl according to the material of the working electrode (WE): +700 mV for graphite (GP) or -100 mV for Prussian blue (PB)-modified SPE, respectively. Biosensor performances were evaluated by means of flow injection amperometric (FIA) measurements. The modified electrodes showed good sensitivity, long-term stability and reproducibility. Under optimal conditions, the PAO biosensor showed a linear range 0.003-0.3 mM for Spm and 0.01-0.4 mM for Spmd, while with the SMO biosensor, a linear range of 0.004-0.5 mM for Spm has been obtained. The main kinetic parameters apparent Michaelis constant (K M), turnover number (K cat) and steady-state current (I max) were determined. The proposed device was then applied to the determination of biogenic amines in blood samples. The results obtained were in good agreement with those obtained with the GC-MS reference method.


Asunto(s)
Amina Oxidasa (conteniendo Cobre)/metabolismo , Técnicas Biosensibles/métodos , Enzimas Inmovilizadas/metabolismo , Espermina/análisis , Técnicas Biosensibles/instrumentación , Humanos , Límite de Detección , Oxidorreductasas actuantes sobre Donantes de Grupo CH-NH/metabolismo , Proteínas Recombinantes , Espermidina/análisis , Espermidina/sangre , Espermina/sangre , Especificidad por Sustrato , Zea mays/enzimología , Poliamino Oxidasa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA