Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Sci Rep ; 14(1): 21511, 2024 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-39277612

RESUMEN

Oral cancer is the most common malignancy in many developing countries, such as India, due to increased consumption of smokeless tobacco. The trace elemental components in commercially packaged forms of tobacco can play a significant role in the pathogenesis of oral cancer. To qualitatively assess the trace elements in various types of commercially packaged forms of tobacco using laser-induced breakdown spectroscopy (LIBS). Two popular varieties of 'Paan masala' that contained a mixture of slaked lime with areca nut, catechu, and other flavouring agents (tobacco was absent) and four types of packaged tobacco were obtained from 'Paan' shops. The contents in the packets were made into pellets using a hydraulic press and subjected to elemental analysis using LIBS. A ten-trial experiment was carried out on all six pellets. The National Institute of Standards and Technology (NIST) database was used to assess the emission lines. The elements obtained from commercially packaged tobacco and Paan masala were similar: calcium (Ca), iron (Fe), aluminium (Al), nickel (Ni), and chromium (Cr). Substances that cause DNA damage and carcinogenesis are inorganic elements such as nickel. Our study revealed that carcinogens such as nickel are present in the commercially packaged forms of tobacco and 'Paan masala' samples.


Asunto(s)
Nicotiana , Oligoelementos , Oligoelementos/análisis , Nicotiana/química , Análisis Espectral/métodos , Níquel/análisis , Rayos Láser , Productos de Tabaco/análisis , Embalaje de Productos , Tabaco sin Humo/análisis , Cromo/análisis , Calcio/análisis , Humanos , Hierro/análisis
2.
Sci Rep ; 14(1): 19327, 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39164370

RESUMEN

Microplastics are one of the concerning environmental pollutants because of their ubiquity. Their capability to adsorb other environmental pollutants increases the risk even further. Existing identification approaches for microplastic characterization for polymer class and their surface-adsorbed heavy metal detection require the utilization of multiple resources and expertise. The article discusses the applicability of a custom-made hyphenated Laser Induced Breakdown Spectroscopy (LIBS)-Raman spectroscopic system in characterizing microplastics by comparing the analytical performance with conventional methods such as Attenuated Total Reflectance- Fourier Transform Infrared (ATR-FTIR) spectroscopy, confocal Raman spectroscopy, and Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy (SEM-EDS). Raman analysis identified polyethylene (PE), polypropylene (PP), and polyethylene terephthalate (PET) plastics, which is confirmed by confocal Raman and FTIR study of the same. LIBS study of microplastics detected heavy metals such as Al, Ni, Co, and Zn, along with Ca and Mg trace elements. The cross-examination with EDS validates these trace elements' presence on the microplastics' surface. The results of the reported LIBS-Raman analysis and its validity evaluated using conventional gold-standard methods show the applicability of the proposed methodology in characterizing microplastics from environmental resources with less or no sample preparation in short time.

3.
Talanta ; 277: 126393, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38865957

RESUMEN

BACKGROUND: Plastic Solid Waste (PSW) sorting is a procedure of paramount importance in the mechanical recycling process of plastics waste. The major limitation of the techniques relying on physical properties of plastics is the time taken for analysis and poor accuracy. Spectroscopy has been shown to be a suitable method in plastic sorting due to its atomic and molecular characterization capabilities, and ability to give results in very short time scales. However, for practical applications it is essential to translate this technique into an automatic technology, by combining it with advanced chemometric tools which can give observer independent judgement. RESULTS: The indigenously developed bi-model Laser Induced Breakdown Spectroscopy (LIBS)-Raman system with single source and single detector can record the LIBS-Raman spectral signals in single-shot mode in a total time frame of 20 ms. Out of the combinations of Principal Component Analysis (PCA) and Partial Least Squares (PLS) with Logistic Regression (LR), Linear Discriminant Analysis (LDA), Support Vector Machine (SVM), and Partial Least Squares-Discriminant Analysis (PLS-DA) based classifiers, the PLS-DA based model showed the maximum classification accuracy with 95 % based on LIBS data and 100 % based on Raman data. The reliability of the model was assessed using 4-fold cross-validation which showed a sensitivity of 90.28 % and specificity of 98.29 % for predictions based on LIBS data, and 99 % sensitivity and 99.82 % specificity for predictions relying on Raman data. SIGNIFICANCE: The results show how the combination of multimodal spectroscopy with chemometric analysis enhances the applicability of spectroscopic techniques for plastic sorting. The classification model successfully classified seven types of post-consumer plastic samples based on combined LIBS and Raman data. With the home-built software for automated prediction, the system takes less than a second to predict the plastic type illustrating the potential of the method for translation to regular routine industrial applications.

4.
Environ Res ; 231(Pt 2): 116198, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37209978

RESUMEN

The increased use of plastic products and global industrial conditions have contaminated natural resources, especially water, with pollutants such as microplastics and trace elements, including heavy metals. Hence, continuous monitoring of water samples is an urgent requirement. However, the existing microplastic-heavy metal monitoring methodologies require discrete and sophisticated sampling approaches. The article proposes a multi-modal LIBS-Raman spectroscopy system for detecting microplastics and heavy metals from water resources with unified sampling and pre-processing approaches. The accomplishment of the detection process is using a single instrument by exploiting the trace element affinity of microplastics, which operates in an integrated methodology to monitor water samples for microplastic-heavy metal contamination. The polypropylene (PP), polyethylene (PE), and polyethylene terephthalate (PET) plastic types dominate the identified microplastics from different sampling spots: in an estuary formed by the Swarna River near Kalmadi (Malpe) in Udupi district, and from River Netravathi in Mangalore, Dakshina Kannada District, Karnataka, India. The detected trace elements from microplastic surfaces include heavy metals such as Al, Zn, Cu, Ni, Mn, and Cr and other elements counting Na, Mg, Ca, and Li. The system could record concentrations of trace elements down to 10 ppm, and comparing results with the conventional technique of Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) confirms the ability of the system to detect trace elements from microplastic surfaces. In addition, comparing results with direct LIBS analysis of water from the sampling site shows better results in microplastic-based trace element detection.


Asunto(s)
Metales Pesados , Oligoelementos , Contaminantes Químicos del Agua , Microplásticos , Plásticos , Oligoelementos/análisis , Espectrometría Raman , Recursos Hídricos , Monitoreo del Ambiente/métodos , Contaminantes Químicos del Agua/análisis , India , Metales Pesados/análisis , Agua
5.
J Conserv Dent ; 26(2): 165-169, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37205890

RESUMEN

Context: In today's era, erosion is the most prevalent type of tooth wear. The prevention of demineralization with biomineralization is the most desired treatment. Aim: The aim of this study is to evaluate and compare the surface remineralization potential of two remineralizing agents - self-assembling peptide P11-4 (SAP P11-4) and calcium silicate plus sodium phosphate (CSSP) salts on intact and demineralized enamel using laser-induced breakdown spectroscopy (LIBS). Subjects and Methods: Sixteen maxillary premolars were decoronated and split into buccal and palatal halves embedded in acrylic resin with a total sample size of 32 designated into Group 1 (intact teeth) and Group 2 (demineralized teeth). Further subdivision into Groups 1a and 2a (SAP P11-4 group [n = 8]); Groups 1b and 2b (CSSP group [n = 8]), Group 2 was first exposed to Coca-Cola. Then, all groups were subjected to experimental LIBS. Groups 1a and 2a were treated with SAP P11-4 based product, i.e., CURODONT™ PROTECT gel. Groups 1b and 2b were treated with CSSP-based products regimen, i.e., REGENERATE Enamel Science™ Advanced Toothpaste and Advanced Enamel Serum. The LIBS assessment was redone for all groups to attain a change in Ca and P values. Statistical Analysis Used: Inferential statistics were done using Wilcoxon signed-rank test (Before-After product application) and Mann-Whitney U-test (between the groups). Results: According to the statistical evaluation there was a statistically significant difference (P < 0.05), in Ca and P values in demineralized teeth when both SAP P11-4 and CSSP groups were evaluated. Although Ca values exhibited a significant difference in intact teeth, P did not exhibit a significant difference on the application of both remineralizing agents. The remineralizing potential between the two agents, SAP P11-4 and CSSP groups. There was no statistically significant difference ( P <0.05) observed between the two agent's remineralization potential for intact and demineralized teeth. Conclusion: SAP P11-4 and CSSP have the potential to remineralize both intact and demineralized enamel. There was increased remineralization in demineralized samples subjected to erosion.

6.
Waste Manag ; 150: 339-351, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-35907331

RESUMEN

Ever-accumulating amounts of plastic waste raises alarming concern over environmental and public health. A practical solution for addressing this threat is recycling, and the success of an industry-oriented plastic recycling system relies greatly on the accuracy of the waste sorting technique adapted. We propose a multi-modal spectroscopic sensor which combines laser-induced breakdown spectroscopy (LIBS) and Raman spectroscopy in a single optical platform for characterizing plastics based on elemental and molecular information to assist the plastic identification-sorting process in recycling industries. The unique geometry of the system makes it compact and cost-effective for dual spectroscopy. The performance of the system in classifying industrially important plastic classes counting PP, PC, PLA, Nylon-1 1, and PMMA is evaluated, followed by the application of the same in real-world plastics comprising PET, HDPE, and PP in different chemical-physical conditions where the system consumes less than 30 ms for acquiring LIBS-Raman signals. The evaluation of the system in characterizing commuting samples shows promising results to be applied in industrial conditions in future. The study on effect of physical-chemical conditions of plastic wastes in characterizing them using the system shows the necessity for combining multiple techniques together. The proposal is not to determine the paramount methodology to characterize and sort plastics, but to demonstrate the advantages of dual-spectroscopy sensors in such applications. The outcomes of the study suggest that the system developed herein has the potential of emerging as an industrial-level plastic waste sorting sensor.


Asunto(s)
Plásticos , Administración de Residuos , Residuos Industriales , Industrias , Reciclaje , Espectrometría Raman
7.
Results Chem ; : 100210, 2021 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-34642620

RESUMEN

Research activities are in full swing globally to translate the use of saliva as a non-invasive and highly potential specimen for clinical diagnostics, particularly for COVID-19 detection. Being comprised of a pool of biomarkers also enriched with ACE-2 receptors, saliva can provide vital information regarding the state of the human body. Advancements in biophotonics tools for saliva investigation may offer promise for developing rapid, highly objective, optical modalities for COVID- 19 detection. This article presents concept/design study, which propose the use of Raman/laser induced fluorescence spectroscopic device that have the potential for viral detection via saliva from a safer distance. Noticeable changes of biomarkers present in saliva in response to viral infection can reflect the pathological state, thus can altogether affect the Raman spectral pattern. Monitoring these spectral patterns of saliva, which are further enhanced by using cost effective and reproducible Surface Enhanced Raman Spectroscopy substrates can be a viable option for sensitive and non-invasive viral detection. The spectral information acquired from the optical device can be processed using various multivariate statistical analytical tools, which ultimately facilitate effective viral detection in few minutes. This method doesn't demand the necessity of qualified professionals and sample processing with reagents unlike in RT-PCR test. The proposed optical device can be further modified into a portable form, which can be easily transported for field applications. The stand-off observation, contactless and highly non-invasive technique can be of paramount importance in the current context, where the safer screening of a large population for viral infection by maintaining social distances is a necessity. The proposed stand-off spectroscopic technique can also address the major concern of nosocomial viral transmission amongst healthcare workers during sample collection in a pandemic scenario.

8.
Biophys Rev ; 13(3): 359-385, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34093888

RESUMEN

Human saliva can be treated as a pool of biological markers able to reflect on the state of personal health. Recent years have witnessed an increase in the use of optical devices for the analysis of body fluids. Several groups have carried out studies investigating the potential of saliva as a non-invasive and reliable clinical specimen for use in medical diagnostics. This brief review aims to highlight the optical technologies, mainly surface plasmon resonance (SPR), Raman, and Fourier transform infrared (FTIR) spectroscopy, which are being used for the probing of saliva for diverse biomedical applications. Advances in bio photonics offer the promise of unambiguous, objective and fast detection of abnormal health conditions and viral infections (such as COVID-19) from the analysis of saliva.

9.
J Phys Chem A ; 124(8): 1508-1514, 2020 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-32040313

RESUMEN

Electrons and •OH-radicals have been generated by using low-energy laser pulses of 6 ns duration (1064 nm wavelength) to create plasma in a suspension of plasmid DNA (pUC19) in water. Upon thermalization, these particles induce single and double strand breakages in DNA along with possible base oxidation/base degradation. The time-evolution of the ensuing structural modifications has been measured; damage to DNA is seen to occur within 30 s of laser irradiation. The time-evolution is also measured upon addition of physiologically relevant concentrations of salts containing monovalent, divalent, or trivalent alkali ions. It is shown that some alkali ions can significantly inhibit strand breakages while some do not. The inhibition is due to electrostatic shielding of DNA, but significantly, the extent of such shielding is seen to depend on how each alkali ion binds to DNA. Results of experiments on strand breakages induced by thermalized particles produced upon plasma-induced photolysis of water, and their inhibition, suggest implications beyond studies of DNA; they open new vistas for utilizing simple nanosecond lasers to explore the effect of ultralow energy radiation on living matter under physiologically relevant conditions.


Asunto(s)
Roturas del ADN de Doble Cadena , ADN/química , Electrones , Radical Hidroxilo/química , Plásmidos , Termodinámica , Agua/química
10.
Talanta ; 208: 120482, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-31816773

RESUMEN

There are a number of analytical techniques used to study material related problems. Most of them imply experimental determination of parameters and functions by means of which elemental, optical and other properties of materials can be described. Laser Induced Breakdown Spectroscopy (LIBS) and Raman spectroscopy are highly complementary spectroscopic techniques used for lab, in-situ, and remote analyses of materials. The LIBS-Raman system provides further information compared to other conventional techniques since it can detect the presence of low atomic number-elements, isotopic composition, hydration and structure of trace materials which may be present as surface layers etc., which are very difficult, if not impossible, by portable X-ray based systems. A setup for LIBS and Raman spectroscopy measurements in a single unit has been developed and reported recently by us using an echelle spectrograph system. The system utilizes a single nanosecond pulsed Nd:YAG laser (532 nm) and an ICCD coupled echelle spectrograph for both measurements. The unit has been successfully used for multipurpose applications such as identification of minerals, pigments etc and also for checking quality assurance. The combined atomic and molecular information from the same location on a sample, at several locations, can provide more comprehensive information regarding its properties than using either of these quantities taken singly. In many cases, it has been observed that the high resolution of the echelle spectrograph provides better quality Raman signals by virtue of the small degeneracy/crystal field splitting of many fundamental Raman bands. This can provide valuable information on inclusions in bulk samples, changes due to symmetry alteration or complex formation with surroundings, hydrogen bonding etc. The advantage of echelle system to identify natural and artificial pigments by identifying the minor and trace components by the spectra of the elements therein, is also helpful in many situations. In the present paper, the orthogonal use of LIBS and Raman spectroscopy is assessed and highlighted. The results clearly demonstrate the potential of echelle-based LIBS-Raman system in applications where more detailed information on complex samples like minerals, archaeological artifacts etc, is required with minimum sample damage or consumption.

11.
J Phys Chem A ; 123(15): 3241-3247, 2019 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-30920832

RESUMEN

Low-power laser pulses of 6 ns duration (1064 nm wavelength) have been used to create plasma in an aqueous solution of plasmid DNA (pUC19). Thermal energy electrons and •OH radicals in the plasma induce strand breakages in DNA, including double strand breaks and possible base oxidation/base degradation. The time evolution of these modifications shows that it takes barely 30 s for damage to DNA to occur. Addition of physiologically relevant concentrations of a salt (NaCl) significantly inhibits such damage. We rationalize such inhibition using simple electrostatic considerations. The observation that DNA damage is induced by plasma-induced photolysis of water suggests implications beyond studies of DNA and opens new vistas for using simple nanosecond lasers to probe how ultralow energy radiation may affect living matter under physiological conditions.


Asunto(s)
Roturas del ADN de Doble Cadena/efectos de los fármacos , ADN/química , Nanoestructuras/química , Sodio/química , ADN/efectos de la radiación , Roturas del ADN de Doble Cadena/efectos de la radiación , Electrones , Radical Hidroxilo , Rayos Láser , Luz , Oxidación-Reducción , Fotólisis , Cloruro de Sodio/química , Electricidad Estática , Agua/química
12.
Rev Sci Instrum ; 89(7): 073108, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30068097

RESUMEN

We have developed and standardized a novel hybrid laser-induced breakdown spectroscopy (LIBS)-Raman system using a single pulsed laser and a high-resolution intensified charge coupled device coupled echelle spectrograph. LIBS and Raman spectroscopy are highly complementary techniques which yield elemental and molecular information. Both techniques share an apparently similar instrumental configuration but need entirely different requirements like spectral range covered, resolution, and light-gathering efficiencies. There are thus many challenges to be faced in developing a combined system. In the present work, we show that an echelle spectrograph combined with a compact Q-switched Nd:YAG laser operating at 532 nm as an excitation source in a portable configuration can be efficiently used for such multi-purpose spectroscopy. Atomic and molecular emissions from the sample surface have been recorded in a gated mode using this setup. Compared to conventional spectrographs, echelle provides simultaneous broad bandpass (250-900 nm) and better spectral resolution at an extremely small fixed slit width of 10 × 50 µm without moving the dispersive elements. The echelle-based hyphenated system provides fast and reliable analysis of materials with combined atomic and molecular spectra of the same spot with better reliability. In this paper, we discuss the optimization of various instrumental parameters and optical components of this hyphenated system using a medium Raman cross section sample, CaCO3. The feasibility of single shot LIBS-Raman measurement capabilities of echelle has also been demonstrated using the developed system.

13.
J Biophotonics ; 11(6): e201700271, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29411942

RESUMEN

Presence of renal-calculi (kidney stones) in human urethra is being increasingly diagnosed over the last decade and is considered as one of the most painful urological disorders. Accurate analysis of such stones plays a vital role in the evaluation of urolithiasis patients and in turn helps the clinicians toward exact etiologies. Two highly complementary laser-based analytical techniques; laser-induced breakdown spectroscopy (LIBS) and micro-Raman spectroscopy have been used to identify the chemical composition of different types of renal-calculi. LIBS explores elemental characteristics while Raman spectroscopy provides molecular details of the sample. This complete information on the sample composition might help clinicians to identify the key aspects of the formation of kidney stones, hence assist in therapeutic management and to prevent recurrence. The complementarity of both techniques has been emphasized and discussed. LIBS spectra of different types of stones suggest the probable composition of it by virtue of the major, minor and trace elements detected from the sample. However, it failed to differentiate the crystalline form of different hydrates of calcium oxalate stone. This lacuna was overcome by the use of Raman spectroscopy and these results are compared with conventional chemical analysis.


Asunto(s)
Cálculos Renales/diagnóstico , Rayos Láser , Espectrometría Raman , Humanos , Cálculos Renales/metabolismo , Ácido Úrico/metabolismo
14.
Anal Bioanal Chem ; 409(13): 3299-3308, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28321503

RESUMEN

Classification of plastics is of great importance in the recycling industry as the littering of plastic wastes increases day by day as a result of its extensive use. In this paper, we demonstrate the efficacy of a combined laser-induced breakdown spectroscopy (LIBS)-Raman system for the rapid identification and classification of post-consumer plastics. The atomic information and molecular information of polyethylene terephthalate, polyethylene, polypropylene, and polystyrene were studied using plasma emission spectra and scattered signal obtained in the LIBS and Raman technique, respectively. The collected spectral features of the samples were analyzed using statistical tools (principal component analysis, Mahalanobis distance) to categorize the plastics. The analyses of the data clearly show that elemental information and molecular information obtained from these techniques are efficient for classification of plastics. In addition, the molecular information collected via Raman spectroscopy exhibits clearly distinct features for the transparent plastics (100% discrimination), whereas the LIBS technique shows better spectral feature differences for the colored samples. The study shows that the information obtained from these complementary techniques allows the complete classification of the plastic samples, irrespective of the color or additives. This work further throws some light on the fact that the potential limitations of any of these techniques for sample identification can be overcome by the complementarity of these two techniques. Graphical Abstract ᅟ.

15.
Spectrochim Acta A Mol Biomol Spectrosc ; 154: 200-206, 2016 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-26529636

RESUMEN

Study of copper complex of creatinine and urea is very important in life science and medicine. In this paper, spectroscopic and structural study of a newly synthesized heteroligand complex of copper with creatinine and urea has been discussed. Structural studies have been carried out using DFT calculations and spectroscopic analyses were carried out by FT-IR, Raman, UV-vis absorption and fluorescence techniques. The copper complex of creatinine and the heteroligand complex were found to have much increased water solubility as compared to pure creatinine. The analysis of FT-IR and Raman spectra helps to understand the coordination properties of the two ligands and to determine the probable structure of the heteroligand complex. The LIBS spectra of the heteroligand complex reveal that the complex is free from other metal impurities. UV-visible absorption spectra and the fluorescence emission spectra of the aqueous solution of Cu-Crn-urea heteroligand complex at different solute concentrations have been analyzed and the complex is found to be rigid and stable in its monomeric form at very low concentrations.


Asunto(s)
Complejos de Coordinación/química , Cobre/química , Creatinina/análogos & derivados , Urea/análogos & derivados , Complejos de Coordinación/síntesis química , Creatinina/síntesis química , Ligandos , Modelos Moleculares , Teoría Cuántica , Espectrometría de Fluorescencia , Espectrofotometría Ultravioleta , Espectroscopía Infrarroja por Transformada de Fourier , Espectrometría Raman , Urea/síntesis química
16.
J Biomed Opt ; 15(6): 067007, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21198211

RESUMEN

The present work deals with the evaluation of a high-performance liquid chromatography laser-induced fluorescence (HPLC-LIF) technique developed in our laboratory for early detection of oral cancer from protein profiles of body fluids. The results show that protein profiles of serum samples from a given class of samples, say, normal, premalignant, or malignant, are statistically very close to each other, while profiles of members of any class are significantly different from other classes. The performance of the technique is evaluated by the use of sensitivity and specificity pairs, receiver operating characteristic (ROC) analysis, and Youden's Index. The technique uses protein profile differences in serum samples, registered by the HPLC-LIF technique. The study is carried out using serum samples from volunteers diagnosed as normal or premalignant clinically, and as malignant by histopathology. The specificities and sensitivities of the HPLC-LIF method at an ideal threshold (M-distance = 2) for normal, malignant, and premalignant classes are 100, 69.5, and 61.5%, and 86.5, 87.5, and 87.5% respectively.


Asunto(s)
Biomarcadores de Tumor/análisis , Análisis Químico de la Sangre/instrumentación , Cromatografía Líquida de Alta Presión/instrumentación , Rayos Láser , Neoplasias de la Boca/diagnóstico , Neoplasias de la Boca/metabolismo , Espectrometría de Fluorescencia/instrumentación , Adulto , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA