Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Indian J Surg Oncol ; 15(Suppl 1): 11-18, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38545577

RESUMEN

The number of elderly patients diagnosed with cancer is increasing. However, knowledge regarding cancer in elderly patients is very scarce. The aim of this study is to analyze the differences in management and outcomes of high-grade extremity sarcomas between elderly and middle-aged patients. Two cohorts were made (> 70 and 30/50 years old) among patients treated in a multidisciplinary unit of a national reference center between 2011 and 2017 with a minimum of 2 years of follow-up. The management and outcomes between these two cohorts were compared. Seventy patients were included, 34 young patients and 36 elderly patients. The only difference between the treatment schemes was the chemotherapy used, 67.6% of the young patients received chemotherapy versus 16.7% of the elderly patients (p = 0.000015). There were no differences either in the overall survival or the progression-free survival between groups at 1 and 2-year follow-up. Deceases for other causes were nearly exclusive of elderly patients at a median of 45.57 months. Surgery is the treatment of choice for sarcomas in both elderly and young patients having similar results in terms of progression-free survival, overall survival, and surgery outcomes. The use of chemotherapy is the only difference in the treatment schemes between both groups. In the elderly patient with minimal or no comorbidity and good functional reserve, surgical curative treatment should be chosen. As for frail elderly patients, the therapeutic objectives must be focused mainly on quality of life and palliation of symptoms.

2.
Clin Biomech (Bristol, Avon) ; 111: 106149, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37976691

RESUMEN

BACKGROUND: The real degree of constraint of rotating hinge knee and condylar constrained prostheses is a matter of discussion in revision knee arthroplasty. The objective of this study is to compare the tibial rotation between implants in the clinical settings. METHODS: An investigator blinded experimental study was designed including 20 patients: in 10 of them a rotating hinge knee prosthesis (Endomodel®, LINK) was implanted and in the remaining 10 a constrained condylar knee prosthesis (LCCK®, Zimmer) was used. A medial parapatellar approach was performed and implantation was performed according to conventional surgical technique. Tibial rotation was measured with two accelerometers in full extension and at 30°, 60° and 90° of flexion. Pre and postoperative Knee Injury and Osteoarthritis Outcome Score was recorded. FINDINGS: Both groups were homogenous in age (73.4 years in rotating hinge knee prosthesis vs 74 years in constrained condylar knee group), sex, laterality and preoperative Knee Injury and Osteoarthritis Outcome Score (p > 0.05). The postoperative Knee Injury and Osteoarthritis Outcome Score was significantly higher in the rotating hinge knee prosthesis group (80.98 vs 76.28). The degrees of tibial rotation measured by inertial sensors in the rotating hinge knee prosthesis group were also significantly higher than those measured in the constrained condylar knee group (5.66° vs 2.1°) with p = 0.001. INTERPRETATION: Rotating hinge knee prosthesis appears to represent a lower rotational constraint degree than constrained condylar knee systems in clinical practice and it may increase the clinical satisfaction. The clinical significance: Rotating hinge knee prosthesis appears to represent a lower constraint degree than constrained condylar knee systems in clinical practice.


Asunto(s)
Traumatismos de la Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Anciano , Diseño de Prótesis , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Reoperación , Traumatismos de la Rodilla/cirugía , Resultado del Tratamiento , Falla de Prótesis , Estudios Retrospectivos
3.
J Ultrasound Med ; 42(6): 1267-1275, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36478278

RESUMEN

OBJECTIVES: We compared an ultra-minimally invasive ultrasound-guided percutaneous A1 pulley release and a classic open surgery for trigger digit. METHODS: We designed a single-center randomized control trial. All cases had clinical signs of primary grade III trigger digit. Concealed allocation (1:1) was used for assigning patients to each group and data collectors were blinded. The Quick-Disabilities of the Arm, Shoulder, and Hand (Quick-DASH) questionnaire was our primary variable. Quick-DASH, two-point discrimination, grip strength, time until stopping analgesics, having full digital range of motion and restarting everyday activities were registered on the 1st, 3rd, and 6th weeks, 3rd and 6th months, and 1st year after the procedure. RESULTS: We randomized 84 patients to ultrasound-guided release and classic open surgery. Quick-DASH scores significantly favored the percutaneous technique until the 3rd month: 7.6 ± 1.2 versus 15.3 ± 2.4 (mean ± standard error of the mean). The percutaneous group obtained significantly better results in all the variables studied: time until stopping analgesics, achieving full range of motion and restarting everyday activities. Grip strength was significantly better in the percutaneous group for the 1st week only. Five cases of moderate local pain were observed in the open technique. There was one case of transient nerve numbness per group. CONCLUSIONS: The ultra-minimally invasive ultrasound-guided A1 pulley release was clinically superior to the classic open surgery in functional recovery with a lower complication rate.


Asunto(s)
Trastorno del Dedo en Gatillo , Humanos , Trastorno del Dedo en Gatillo/diagnóstico por imagen , Trastorno del Dedo en Gatillo/cirugía , Ultrasonografía , Recuperación de la Función , Dolor , Ultrasonografía Intervencional/métodos , Analgésicos
4.
Int Orthop ; 46(4): 677-685, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34988621

RESUMEN

PURPOSE: Microencapsulation techniques have allowed the addition of rifampicin to bone cement, but its in vivo efficacy has not been proven. The aim of our study is to determine the superiority of cement containing gentamicin and rifampicin microcapsules in the treatment of PJI versus cement exclusively containing gentamicin. METHODS: An S. aureus PJI was induced in 15 NZW rabbits. A week after inoculation, the first stage of replacement was carried out, and the animals were divided into two groups: group R received a spacer containing gentamicin and rifampicin microcapsules, and group C received a spacer containing gentamicin. Intra-articular release curve of rifampicin and infection and toxicity markers were monitored for four weeks post-operatively, when microbiological analysis was performed. RESULTS: The microbiological cultures showed a significantly lower growth of S. aureus in soft tissue (2.3·104 vs 0; p = 0.01) and bone (5.7·102 vs 0; p = 0.03) in the group with rifampicin microcapsules. No differences were found in systemic toxicity markers. Rifampicin release from the cement spacer showed higher concentrations than the staphylococcal MIC throughout the analysis. CONCLUSION: The in vivo analyses demonstrated the superiority of cement containing gentamicin and rifampicin microcapsules versus the isolated use of gentamicin in the treatment of PJI in the rabbit model without serious side effects due to the systemic absorption of rifampicin. Given the increasing incidence of staphylococci-related PJI, the development of new strategies for intra-articular administration of rifampicin for its treatment has a high clinical impact.


Asunto(s)
Infecciones Relacionadas con Prótesis , Rifampin , Animales , Antibacterianos/uso terapéutico , Cementos para Huesos/uso terapéutico , Humanos , Infecciones Relacionadas con Prótesis/microbiología , Conejos , Rifampin/uso terapéutico , Staphylococcus aureus
5.
BMC Musculoskelet Disord ; 22(1): 360, 2021 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-33863319

RESUMEN

BACKGROUND: 3D printing technology in hospitals facilitates production models such as point-of-care manufacturing. Orthopedic Surgery and Traumatology is the specialty that can most benefit from the advantages of these tools. The purpose of this study is to present the results of the integration of 3D printing technology in a Department of Orthopedic Surgery and Traumatology and to identify the productive model of the point-of-care manufacturing as a paradigm of personalized medicine. METHODS: Observational, descriptive, retrospective and monocentric study of a total of 623 additive manufacturing processes carried out in a Department of Orthopedic Surgery and Traumatology from November 2015 to March 2020. Variables such as product type, utility, time or materials for manufacture were analyzed. RESULTS: The areas of expertise that have performed more processes are Traumatology, Reconstructive and Orthopedic Oncology. Pre-operative planning is their primary use. Working and 3D printing hours, as well as the amount of 3D printing material used, vary according to the type of product or material delivered to perform the process. The most commonly used 3D printing material for manufacturing is polylactic acid, although biocompatible resin has been used to produce surgical guides. In addition, the hospital has worked on the co-design of customized implants with manufacturing companies. CONCLUSIONS: The integration of 3D printing in a Department of Orthopedic Surgery and Traumatology allows identifying the conceptual evolution from "Do-It-Yourself" to "POC manufacturing".


Asunto(s)
Procedimientos Ortopédicos , Traumatología , Humanos , Modelos Anatómicos , Sistemas de Atención de Punto , Impresión Tridimensional , Estudios Retrospectivos
6.
3D Print Med ; 7(1): 11, 2021 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-33890198

RESUMEN

BACKGROUND: The integration of 3D printing technology in hospitals is evolving toward production models such as point-of-care manufacturing. This study aims to present the results of the integration of 3D printing technology in a manufacturing university hospital. METHODS: Observational, descriptive, retrospective, and monocentric study of 907 instances of 3D printing from November 2015 to March 2020. Variables such as product type, utility, time, or manufacturing materials were analyzed. RESULTS: Orthopedic Surgery and Traumatology, Oral and Maxillofacial Surgery, and Gynecology and Obstetrics are the medical specialties that have manufactured the largest number of processes. Working and printing time, as well as the amount of printing material, is different for different types of products and input data. The most common printing material was polylactic acid, although biocompatible resin was introduced to produce surgical guides. In addition, the hospital has worked on the co-design of custom-made implants with manufacturing companies and has also participated in tissue bio-printing projects. CONCLUSIONS: The integration of 3D printing in a university hospital allows identifying the conceptual evolution to "point-of-care manufacturing."

7.
3D Print Med ; 7(1): 7, 2021 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-33683485

RESUMEN

BACKGROUND: 3D printing and distributed manufacturing represent a paradigm shift in the health system that is becoming critical during the COVID-19 pandemic. University hospitals are also taking on the role of manufacturers of custom-made solutions thanks to 3D printing technology. CASE PRESENTATION: We present a monocentric observational case study regarding the distributed manufacturing of three groups of products during the period of the COVID-19 pandemic from 14 March to 10 May 2020: personal protective equipment, ventilatory support, and diagnostic and consumable products. Networking during this period has enabled the delivery of a total of 17,276 units of products manufactured using 3D printing technology. The most manufactured product was the face shields and ear savers, while the one that achieved the greatest clinical impact was the mechanical ventilation adapters and swabs. The products were manufactured by individuals in 57.3% of the cases, and our hospital acted as the main delivery node in a hub with 10 other hospitals. The main advantage of this production model is the fast response to stock needs, being able to adapt almost in real time. CONCLUSIONS: The role of 3D printing in the hospital environment allows the reconciliation of in-house and distributed manufacturing with traditional production, providing custom-made adaptation of the specifications, as well as maximum efficiency in the working and availability of resources, which is of special importance at critical times for health systems such as the current COVID-19 pandemic.

8.
Hip Int ; 31(2): 242-249, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31746228

RESUMEN

INTRODUCTION: The management of massive femoral bone defects following prosthetic infection remains a surgical challenge, particularly when the entire femur is affected. METHODS: We present the first results of a new biarticular cement spacer with antibiotic technique using a cephalomedullary nail for the treatment of infected hip arthroplasty involving complete femoral bone loss. RESULTS: 5 patients with a minimum follow-up of 1 year were included. In all cases 2-stage replacement due to hip periprosthetic infection was carried out, with the need for a biarticular complete femoral spacer in view of the magnitude of the bone defect. The infection was resolved in all patients, with no complications (spacer fracture or dislocation) associated to spacer use, and the patients were all able to maintain the sitting position with active knee movements between the 2 surgical stages. Improvement with respect to preoperative functional status was observed in all cases, as evidenced by the Harris Hip Score (HHS) (from 24.2 to 73; p < 0.001) and 12-Item Short-Form Health Survey (SF-12) (from 16.8 to 33.2; p = 0.001), with a lessened need for walking aids. DISCUSSION: The described technique offers a possible solution to a number of complications observed with the use of spacers in massive defects, affording greater patient comfort and autonomy while waiting to receive total femoral replacement.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , Antibacterianos , Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Cementos para Huesos , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/cirugía , Reoperación
9.
Injury ; 51 Suppl 1: S25-S29, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32409187

RESUMEN

BACKGROUND: The increase in life expectancy has led to the appearance of a subgroup of hip fracture (HF) patients with special characteristics known as centenarians. The aim of the present study is to analyse the demographic characteristics, complications and mortality rate of this subgroup in order to identify the specific risk factors for mortality in these patients. METHODS: Retrospective analysis of 69 patients (58 women and 11 men) aged 100 years or older admitted to a tertiary hospital for HF between 1999 and 2018. RESULTS: The average age was 101.3 years (100-108, median 101). More than half (62.3%) of all patients presented with extracapsular fractures. The most common complications observed were delirium (52.3%) and urinary retention (27.7%). Haematoma (9.2%) was the most common surgical complication. Only 3 patients (7.3%) changed their place of residence after admission. In-hospital, 30-day and 1-year mortality rates were 13.8%, 21.5% and 54.2%, respectively. A high Charlson Comorbidity Index and baseline Functional Ambulation Classification (FAC) <3 were associated with a higher in-hospital mortality rate (OR = 1.95 95% CI [1.03-3.69] and OR = 5.7 95% CI [1.2-26.8]), respectively. The presence of more than 3 comorbidities and baseline FAC <3 were associated with a higher risk of 30-day mortality (OR = 6, 95% CI [1.4-24.7] and OR = 4, 95% CI [1.13-14.2]), respectively. Dementia has been associated with a higher risk of 30-day and 1-year mortality (OR = 4.6, 95% CI [1.2-16.7]) and OR = 5.11, 95% CI [1.6-21]) respectively. CONCLUSION: FAC score, number of comorbidities, dementia and the Charlson Comorbidity Index have been shown to be risk factors of mortality in centenarians with HF.


Asunto(s)
Fracturas de Cadera/mortalidad , Fracturas de Cadera/cirugía , Complicaciones Posoperatorias/epidemiología , Factores de Edad , Anciano de 80 o más Años , Comorbilidad , Delirio/epidemiología , Femenino , Hematoma/epidemiología , Mortalidad Hospitalaria , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Estudios Retrospectivos , Factores de Riesgo , España , Resultado del Tratamiento , Retención Urinaria/epidemiología
10.
Knee ; 27(3): 1106-1112, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31982249

RESUMEN

BACKGROUND: Infection after arthroplasty (prosthetic joint infection; PJI) is a devastating complication that can lead to functional loss of the affected limb. The purpose of the present study is to develop an animal model of PJI using a three-dimensional printed species-specific implant, which is a step forward for future research to develop new therapeutic strategies. METHODS: Fifteen New Zealand White rabbits were employed to reproduce PJI by intra-articular inoculation of 105 cfu/ml of Staphylococcus aureus ATCC® 29213. Three-dimensional printing technology was used to design a species-specific four-millimeter-thick implant maintaining the anatomical irregularities of the tibial-articular surface. Response to bacterial inoculation was monitored by clinical (weight and temperature), hematological (leukocyte, lymphocyte and platelet counts) and biochemical (erythrocyte sedimentation rate) analyses at the time of inoculation and seven days thereafter, when microbiological samples for culture were also taken. RESULTS: All animals recovered from surgery and all displayed full weight-bearing four days postoperatively. Fourteen of the 15 tested animals (93.3%) presented positive microbiological cultures. A statistically significant increase was found in the number of platelets and leukocytes, as well as a significant decrease in the percentage of lymphocytes, with P = 0.0001 in all cases. CONCLUSIONS: An experimental model faithfully reproducing the periprosthetic infection environment and achieving a high rate of infection has been designed. The use of three-dimensional printed species-specific implants allows rapid postoperative recovery of animals and the development of a stable biofilm. These characteristics make it an interesting model to study its pathogenesis and possible therapeutic strategies.


Asunto(s)
Artritis Infecciosa/etiología , Artroplastia de Reemplazo/instrumentación , Modelos Animales de Enfermedad , Prótesis Articulares/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Estafilocócicas/etiología , Animales , Artroplastia de Reemplazo/efectos adversos , Impresión Tridimensional , Conejos , Tibia/cirugía
11.
Injury ; 50 Suppl 1: S24-S29, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31036366

RESUMEN

BACKGROUND: Between the different options in pelvic external fixation, the supra-acetabular pin placement is considered the best option by many authors. The aim of this study is to describe the surgical technique of the ultrasound-guided supra-acetabular pelvic external fixator (US-SA FIX). SURGICAL TECHNIQUE: Description of the steps to perform the US-SA FIX technique. DISCUSSION: The supra-acetabular pin placement is considered the best option and it is the most wildly used because it combines three crucial qualities: safety, simplicity, and effectiveness. Notwithstanding, when a severely multiple injured patient arrives at the emergency room we need to perform an emergency external fixation, however trained x-ray technicians or pelvic surgeons are not always present, making it difficult to perform the surgery with the proper intra-operative imaging, increasing the surgical time with potentially serious repercussions, a case scenario where the ultrasound can be a very helpful tool. Ultrasound-guided supra-acetabular pelvic external fixator pin placement is feasible without compromising the reliability of its placement, and the application of this new technique in clinical practice in our centre brings encouraging results.


Asunto(s)
Acetábulo/diagnóstico por imagen , Fijadores Externos , Fijación de Fractura , Fracturas Óseas/diagnóstico por imagen , Ultrasonografía Intervencional , Acetábulo/lesiones , Acetábulo/cirugía , Fenómenos Biomecánicos , Clavos Ortopédicos , Fijación de Fractura/métodos , Fracturas Óseas/patología , Fracturas Óseas/cirugía , Humanos , Estudios Retrospectivos
12.
Eur J Orthop Surg Traumatol ; 29(5): 967-973, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30864016

RESUMEN

INTRODUCTION: Periprosthetic infection is considered an increasing incidence pathology whose therapeutic strategies can be defined as unsatisfactory. Currently, animal models are employed to study its physiopathology and strategic therapies, but non-species-specific materials are implanted as foreign bodies. The use of these implants implies intrinsic instability, which hinders the development of a biofilm on their surfaces and complicates the post-operative recovery of the animal. The objective of the present study is the design of a species-specific implant for the New Zealand white (NZW) rabbit by means of 3D printing. MATERIALS AND METHODS: A CT scan of the knee of a NZW rabbit was performed, and the tibial surface was reconstructed in order to fabricate a species-specific tibial plateau using Horos® and Autodesk® Meshmixer™ software. This implant was inserted in fifteen NZW rabbits, and the assessment of its stability was based on the position of the limb at rest and the animal weight-bearing capacity. Biofilm formation on the surface was demonstrated by crystal violet staining. RESULTS: A 1.81 cm × 1 cm × 1.24 cm stainless steel implant was designed. It consisted of a 4-mm-thick tibial plate with a rough surface and an eccentric metaphyseal anchoring. All of the animals exhibited hyperflexion of the operated limb immediately post-operative, and 100% could apply full weight bearing from day 5 after surgery. CONCLUSIONS: The species-specific design of implants in experimental surgery encourages rapid recovery of the animal and the development of a biofilm on their surfaces, making them ideal for the study of the physiopathology and for establishing possible therapeutic targets for prosthetic infection.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Placas Óseas , Diseño Asistido por Computadora , Articulación de la Rodilla , Prótesis de la Rodilla , Modelos Animales , Diseño de Prótesis/métodos , Animales , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Modelos Anatómicos , Impresión Tridimensional , Conejos , Procedimientos de Cirugía Plástica/efectos adversos , Procedimientos de Cirugía Plástica/métodos , Tibia/cirugía
13.
J Knee Surg ; 32(2): 180-185, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29514371

RESUMEN

The true value of use of patient-specific instrumentation (PSI) systems by inexperienced surgeons during their learning curve to improve the clinical and radiographic outcome of unicompartmental knee arthroplasty (UKA) has not been previously studied. Fifty patients with a mean age of 64.3 years undergoing surgery for Oxford UKA were prospectively divided into two groups. Twenty-five patients were operated on by a surgeon with no prior experience in UKA using a PSI system and the other 25 patients by an experienced surgeon using a conventional procedure. Patients were scored using joint range of motion (ROM), the Knee Society Score (KSS), the Knee Injury and Osteoarthritis Outcome Score (KOOS), and the 12-item Short-Form (SF-12) before and 3 months and 2 years after surgery. Impact of use of PSI was measured by comparing clinical and radiographic outcome, complications, and implant survival. No evidence of poorer clinical outcome was seen in any subscale of KSS, KOOS, and SF-12 for inexperienced surgeons using PSI (p = 0.45, p = 0.32, and p = 0.61, respectively). No difference was found between the two procedures in precision of radiographic alignment of components (p = 0.53). No complication occurred in any group. PSI may improve precision of component alignment during the learning curve of surgeons, thus achieving functional results similar to those of more experienced surgeons using a conventional procedure.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Articulación de la Rodilla/diagnóstico por imagen , Curva de Aprendizaje , Evaluación del Resultado de la Atención al Paciente , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Humanos , Articulación de la Rodilla/cirugía , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Cirugía Asistida por Computador
14.
Injury ; 49 Suppl 2: S36-S43, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30219146

RESUMEN

We describe the methodical and possibilities of 3D surgical printing in preoperative planning for a total hip arthroplasty in acetabular deformity after acetabular fractures, showing a case of a 43-year-old with posttraumatic arthritis after both column fracture of the left acetabulum that was treated non operatively, supporting the do it yourself mode.


Asunto(s)
Acetábulo/diagnóstico por imagen , Artroplastia de Reemplazo de Cadera , Tratamiento Conservador/efectos adversos , Fracturas Óseas/cirugía , Luxación de la Cadera/cirugía , Osteoartritis de la Cadera/diagnóstico por imagen , Impresión Tridimensional , Acetábulo/anatomía & histología , Acetábulo/lesiones , Adulto , Hueso Esponjoso/patología , Fracturas Óseas/diagnóstico por imagen , Luxación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Osteoartritis de la Cadera/etiología , Osteoartritis de la Cadera/cirugía , Resultado del Tratamiento
15.
Arthroplast Today ; 4(1): 58-64, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29560397

RESUMEN

Bone cement spacers loaded with antibiotic are the gold standard in septic revision. However, the management of massive bone defects constitutes a surgical challenge, requiring the use of different nails, expensive long stems, or cement-coated tumor prostheses for preparing the spacer. In most cases, the knee joint must be sacrificed. We describe a novel technique for preparing a biarticular total femur spacer with the help of a trochanteric nail coated with antibiotic loaded cement, allowing mobility of the hip and knee joints and assisted partial loading until second step surgery. This technique is helpful to maintain the length of the leg, prevent soft tissue contracture, and help eradicate the infection preserving the patient comfort and autonomy while waiting to receive total femoral replacement.

16.
Stem Cells Int ; 2018: 6025918, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29535772

RESUMEN

ORTHOUNION is a multicentre, open, comparative, three-arm, randomized clinical trial (EudraCT number 2015-000431-32) to compare the efficacy, at one and two years, of autologous human bone marrow-derived expanded mesenchymal stromal cell (hBM-MSC) treatments versus iliac crest autograft (ICA) to enhance bone healing in patients with diaphyseal and/or metaphysodiaphyseal fracture (femur, tibia, and humerus) status of atrophic or oligotrophic nonunion (more than 9 months after the acute fracture, including recalcitrant cases after failed treatments). The primary objective is to determine if the treatment with hBM-MSCs combined with biomaterial is superior to ICA in obtaining bone healing. If confirmed, a secondary objective is set to determine if the dose of 100 × 106 hBM-MSCs is noninferior to that of 200 × 106 hBM-MSCs. The participants (n = 108) will be randomly assigned to either the experimental low dose (n = 36), the experimental high dose (n = 36), or the comparator arm (n = 36) using a central randomization service. The trial will be conducted in 20 clinical centres in Spain, France, Germany, and Italy under the same clinical protocol. The confirmation of superiority for the proposed ATMP in nonunions may foster the future of bone regenerative medicine in this indication. On the contrary, absence of superiority may underline its limitations in clinical use.

17.
J Orthop Res ; 36(1): 459-466, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28543702

RESUMEN

Two-stage exchange with antibiotic-loaded bone cement spacers remains the gold standard for chronic periprosthetic joint infection (PJI). Rifampicin is highly efficient on stationary-phase staphylococci in biofilm; however, its addition to PMMA to manufacture spacers prevents polymerization and reduces mechanical properties. Isolation of rifampicin during polymerization by microencapsulation could allow manufacturing rifampicin-loaded bone cement maintaining elution and mechanical properties. Microcapsules of rifampicin with alginate, polyhydroxybutyratehydroxyvalerate (PHBV), ethylcellulose and stearic acid (SA) were synthesized. Alginate and PHBV microcapsules were added to bone cement and elution, compression, bending, hardness, setting time and microbiological tests were performed. Repeated measures ANOVA and Bonferroni post-hoc test were performed, considering a p < 0.05 as statistical significance. Bone cement specimens containing alginate microcapsules eluted more rifampicin than PHBV microcapsules or non-encapsulated rifampicin over time (p < 0.012). Microencapsulation of rifampicin allowed PMMA to preserve mechanical properties in compression and bending tests. Cement with alginate microcapsules showed similar behavior in hardness tests to control cement over the study period (73 ± 1.68HD ). PMMA with alginate microcapsules exhibited the largest zones of inhibition in microbiological tests. Statistically significant differences in mean diameters of zones of inhibition between PMMA loaded with alginate-rifampicin (p = 0.0001) and alginate-PHBV microcapsules (p = 0.0001) were detected. Rifampicin microencapsulation with alginate is the best choice to introduce rifampicin in PMMA preserving mechanical properties, setting time, elution, and antimicrobial properties. The main applicability of this study is the opportunity for obtaining rifampicin-loaded PMMA by microencapsulation of rifampicin in alginate microparticles, achieving high doses of rifampicin in infected tissues, increasing the successful of PJI treatment. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:459-466, 2018.


Asunto(s)
Antibacterianos/administración & dosificación , Cementos para Huesos , Composición de Medicamentos/métodos , Rifampin/administración & dosificación , Alginatos/química , Fenómenos Biomecánicos , Humanos , Poliésteres/química , Polimetil Metacrilato/química , Infecciones Relacionadas con Prótesis/prevención & control , Rifampin/química
18.
Injury ; 48 Suppl 6: S66-S74, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29162245

RESUMEN

INTRODUCTION: Pelvic fracture in trauma patients can lead to hemodynamic instability. External fixation is a treatment capable of stabilizing these injuries in the context of damage control surgery. Supra-acetabular pin offers the greater biomechanical stability but requires the use of intraoperative fluoroscopy. The aim of this study was to analyze our results for an ultrasound-guided supra-acetabular pinning. MATERIAL AND METHODS: Cross-sectional study with cadaveric specimens. Ultrasound-guided pin placement assessed by fluoroscopy and dissection. RESULTS: Fourteen ultrasound-guided supra-acetabular pins were placed in seven cadaveric specimens. Excellent placement in all cases, evaluated with radiological control. Good qualitative bone fixation after dissection. One femoral cutaneous nerve was not found during anatomic dissection and was assumed injured. CONCLUSION: Ultrasound-guided supra-acetabular pin placement is a feasible and effective technique. Our study indicates that pin placement without intraoperative fluoroscopy is feasible without compromising the reliability of its placement.


Asunto(s)
Fijación de Fractura , Fracturas Óseas/cirugía , Huesos Pélvicos/cirugía , Ultrasonografía Intervencional , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Clavos Ortopédicos , Cadáver , Estudios Transversales , Fijadores Externos , Femenino , Fijación de Fractura/métodos , Fracturas Óseas/diagnóstico por imagen , Humanos , Masculino , Modelos Biológicos , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/lesiones , Reproducibilidad de los Resultados
19.
Knee ; 24(6): 1359-1368, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28978460

RESUMEN

INTRODUCTION: In valgus knees of young patients, opening-wedge distal femoral osteotomy is a valid treatment option for axial corrections. It allows the surgeon to achieve accurate correction, which is directly related to the functional outcome and survivorship of the osteotomy. This study presents a new technique based on three-dimensional (3D)-printed cutting guides for opening-wedge distal femoral osteotomies, in which pre-operative planning and intraoperative executional accuracy play a major role. MATERIAL AND METHODS: Pursuing axial correction accuracy, 3D-printed patient-specific positioning guides and wedge spacers were both created and used by the surgeon to implement the femoral osteotomy. The proposed technique was performed in 12 consecutive patients (cases). The results were compared with 20 patients (controls) in which opening-wedge distal femoral osteotomies were performed following the traditional technique. Accuracy of the axial correction, surgical time, fluoroscopic time and costs were measured. RESULTS: More accurate axial correction with reduced surgical time (32min less), intraoperative fluoroscopic images (59 images less) and costs (estimated €412 less) were achieved with the use of the customized guides when compared with the traditional technique. DISCUSSION: Accurate correction of the axial alignment of the limb is a critical step in survivorship of the osteotomy. Improving the technique to enhance accuracy focused on this issue. CONCLUSIONS: The use of patient-customized cutting guides minimised human error; therefore, surgical time was reduced and accurate axial correction was achieved. The surgeon mastered all steps in a do-it-yourself philosophy style.


Asunto(s)
Fémur/cirugía , Osteotomía/instrumentación , Impresión Tridimensional , Adulto , Estudios de Casos y Controles , Ahorro de Costo , Femenino , Fluoroscopía/estadística & datos numéricos , Humanos , Masculino , Tempo Operativo , Osteoartritis de la Rodilla/cirugía , Cuidados Preoperatorios
20.
Hip Int ; 27(6): e15-e18, 2017 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-28983889

RESUMEN

INTRODUCTION: Since the recent failure of certain coating models, hybrid implants (coated acetabular inserts with conventional stems) and stems with modular necks, there has been growing interest in the consequences of the generation and release of metal particles at the prosthetic interfaces. The use of ceramic heads has recently been described as an option for reducing the production of metal ions and their consequences. CASE REPORT: The present case report describes the first complete metallisation of a ceramic head secondary to an excessive release of metal ions at the head-neck junction. CONCLUSIONS: We believe this to have occurred due to the use of 12/14 cones of different manufacturers.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Cerámica , Prótesis de Cadera , Metales , Osteoartritis de la Cadera/cirugía , Acetábulo/diagnóstico por imagen , Anciano , Humanos , Masculino , Ensayo de Materiales , Diseño de Prótesis , Falla de Prótesis , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA