Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
BMC Ophthalmol ; 24(1): 384, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39215237

RESUMEN

PURPOSE: To assess the efficacy of a gelatin stent (XEN 45 Gel Stent; Allergan) implant in advanced glaucoma eyes that have failed prior aqueous shunt implantation. METHODS: We retrospectively reviewed 6 patients with refractory glaucoma, defined as persistently high IOP (> 21 mmHg) despite taking at least 3 IOP-lowering medications subsequent to undergoing a glaucoma drainage device (GDD) with or without a second GDD or cilioablative procedure. Eyes with previous failed GDD underwent subconjunctival 0.3 cc (0.4 mg/ml) mitomycin C, tenonectomy, and placement of an ab- externo XEN stent. The outcome measures included change in IOP and the number of glaucoma medications. Success was defined as patients achieving an IOP ≤ 18 mmHg with a percentage reduction of 25% or 15 mmHg and 40% mean IOP reduction from baseline while taking the same number or fewer medications. RESULTS: All six eyes with age of 77.6 ± 7.82 years who underwent XEN implantation following previous GDD surgery had primary open-angle glaucoma. The IOP decreased significantly from 32.33 ± 5.99 to 12.67 ± 3.27 mmHg (p < 0.001) with a follow-up of 13.9 ± 2 (11.7-16.7) months. Visual acuity and visual field remained stable after XEN placement. Compared to the baseline number of medications of 4.2 ± 0.8, all medication was discontinued except in one eye on two drops at the end of the follow-up. The overall surgical success rate was 100%. No complications, needling, or additional procedures were required. CONCLUSION: This study described successful implantation of the XEN stent following failed GDD. XEN Gel stent implantation associated with mitomycin C and tenonectomy can be considered a viable surgical option for patients with a history of previously failed tube shunt requiring further IOP lowering.


Asunto(s)
Implantes de Drenaje de Glaucoma , Presión Intraocular , Stents , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Femenino , Presión Intraocular/fisiología , Anciano , Agudeza Visual/fisiología , Anciano de 80 o más Años , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/fisiopatología , Glaucoma/cirugía , Glaucoma/fisiopatología , Implantación de Prótesis/métodos , Persona de Mediana Edad , Resultado del Tratamiento , Gelatina/uso terapéutico , Estudios de Seguimiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA