Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
J Arthroplasty ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38626864

RESUMEN

BACKGROUND: Despite the growing popularity of cementless total knee arthroplasty (TKA) in younger patients, the outcomes are unclear in the elderly population. We aimed to compare the clinical outcomes and survivorship of cementless TKA between different age groups. METHODS: Utilizing our prospectively collected institutional database, we retrospectively reviewed all patients undergoing primary cementless TKAs at a tertiary care institute. We identified 347 TKA, which were divided into 3 groups based on age at the time of surgery. Group A was ≤ 60 years, Group B was 60 to ≤ 70 years, and Group C was > 70 years. We compared clinical outcomes (Knee Society Clinical Rating System [KSCRS], Western Ontario and McMaster University Osteoarthritis Index [WOMAC], and Veterans Rand 12 Item Health Survey [VR-12]) and survivorship between the groups. RESULTS: At final follow-up, range of motion, KSCRS, WOMAC, and VR-12 physical score were comparable (P > .05). The VR-12 Mental score was higher in Group B and Group C than in Group A (P = .003). Compared to preoperative scores, the change in KSCRS, WOMAC, and VR-12 physical and mental scores was comparable at the final follow-up (P > .05). No patient underwent revision for aseptic loosening. CONCLUSIONS: There were no cases of revision surgery for aseptic loosening in our cohort of 347 cementless TKAs. Patients > 70 years of age undergoing cementless TKA can achieve clinical scores equivalent to those of younger patients at short term (2-year) follow-up. Longer-term survivorship is still required, but based on early data, cementless TKA can be a safe option for older patients.

2.
J Arthroplasty ; 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38522799

RESUMEN

BACKGROUND: Bicruciate-stabilized (BCS) total knee arthroplasty (TKA) designs attempt to approximate natural knee mechanics. Multiple surgical techniques, including gap balancing (GB) and measured resection (MR), have been developed to provide optimal implant positioning and soft-tissue balance. The goal of this study was to determine the effect of surgical technique on BCS TKA contact kinematics. Secondary goals included investigating the change of kinematics over time and comparing BCS TKA kinematics to a posterior-stabilized (PS) design. METHODS: The study included the BCS-GB, BCS-MR, and PS-MR groups. The BCS-GB and BCS-MR groups underwent weight-bearing radiostereometric analysis for multiple knee flexion angles at 3 months and 1 year postoperatively, whereas the PS-MR group was imaged at 1 year postoperatively. The medial and lateral contact kinematics were determined from implant poses. RESULTS: There were no differences in BCS TKA kinematics between the GB and MR techniques. There were differences in the mid-flexion ranges when comparing the 3-month and 1-year kinematics of the BCS design; however, they were less than 1.5 mm. Differences existed between the kinematics of the BCS and PS designs at all flexion angles for the medial condyle (P < .0006) and at 0° of flexion on the lateral condyle (P < .0001). CONCLUSIONS: Contact kinematics for a BCS design were similar for both surgical techniques, suggesting both are appropriate for this design. Small, likely clinically insignificant differences were found between 3-month and 1-year kinematics. The BCS TKA kinematics differed from the PS design; however, it is unclear whether these differences improve clinical outcomes.

3.
J Arthroplasty ; 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38521249

RESUMEN

BACKGROUND: Modular titanium fluted tapered (TFT) stems have demonstrated excellent clinical success for femoral revision total hip arthroplasty (THA) surgery. This study reports the short-term outcomes of a novel modern monoblock TFT stem used for revision and complex primary THA with a minimum of 2 years of follow-up. METHODS: We identified 126 patients who received a single monoblock TFT stem: 26 patients for complex THA (failed fracture fixation) and 100 patients for revision THA. The reasons for revision THA included 40 for previous periprosthetic joint infection, 42 for aseptic loosening, 9 for trunnionosis, and 9 for periprosthetic fractures. The Paprosky grading for femoral bone loss at the time of surgery and the measured subsidence of femoral stems at 3-month follow-up were determined. We evaluated the number and indications for reoperations. RESULTS: The mean time from surgery was 3.9 years (range, 2.0 to 6.9). A paired t-test analysis showed significant improvement from preoperative versus postoperative clinical outcome scores (P < .001) for Harris Hip Score (38.76 ± 15.24 versus 83.42 ± 15.38), Western Ontario and McMaster Universities Arthritis Index (45.6 ± 19.0 versus 69.9 ± 21.3), Veterans RAND 12 Item Health Survey Physical component (31.7 ± 8.1 versus 37.8 ± 11.3), and Veterans RAND 12 Item Health Survey Mental component (48.2 ± 12.2 versus 51.6 ± 12.5). The Paprosky grading for femoral bone loss was Grade 1 (3.9%), Grade 2 (35.7%), Grade 3A (47.6%), Grade 3B (11.1%), and Grade 4 (1.6%) cases. There were 18 reoperations (14.7%), with 13 for periprosthetic joint infection (7 treated with implant retention and 6 treated with a 2-stage revision), 4 for instability, and 1 for acetabular aseptic loosening. There were no aseptic failures of the stem. CONCLUSIONS: This novel modern monoblock TFT stem provided reliable femoral fixation and has increasingly supplanted the use of modular TFT stems for complex primary and revision surgery in our institution.

4.
Can J Surg ; 67(2): E85-E90, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38453351

RESUMEN

BACKGROUND: Interest in cementless total knee arthroplasty (TKA) has increased with advancement of biomaterials and implant design and associated improved longevity. We sought to evaluate the gap patterns and radiolucent zones radiographically for 2 newer-generation cementless TKA designs. METHODS: We retrospectively reviewed our single-institution database between January 2017 and December 2019. We identified patients with a porous keeled tibia base-plate with 4-bullet cruciform spikes and peri-apatite coated femoral component (study group 1) and patients who received a cementless porous coated femoral component and rotating platform tibia baseplate with 4 peripheral porous coated pegs around a central cone (study group 2). We identified gap patterns at 6 weeks and at 1 year or more postoperatively on radiographs, noting indications for reoperation. RESULTS: We identified 228 patients in study group 1 and 41 patients in study group 2. At 1-year follow-up, we found evidence of resolved femoral gaps in 52 (72.2%) of 72 patients in study group 1 and 10 (58.8%) of 17 patients in study group 2 (p = 0.124). We identified 27 (84.3%) of 32 patients in study group 1 and 7 (70.0%) of 10 patients in study group 2 with resolved tibia gaps (p = 0.313). After 1 year, there were significantly more Zone 3a femoral zonal radiolucent gaps (p = 0.001) and Zone 8 tibia zonal radiolucent gaps (p = 0.002) in study group 2 than in study group 1. There were 4 reoperations for study group 1 and 0 reoperations for study group 2. CONCLUSION: The modern cementless TKA systems have varied gap patterns in postoperative radiographs, which may be attributed to the implant design. Most radiolucent gaps resolve radiographically on follow-up.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Estudios de Seguimiento , Estudios Retrospectivos , Fémur/diagnóstico por imagen , Fémur/cirugía , Reoperación , Diseño de Prótesis , Resultado del Tratamiento , Falla de Prótesis
5.
Hip Int ; 34(1): 42-48, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37016808

RESUMEN

BACKGROUND: Early cup migration after total hip arthroplasty (THA) is correlated to late revision due to aseptic loosening. However, the use of screws for increased cup stability remains unclear and debated. The purpose of this study is to assess acetabular migration between cups fixated with and without the use of screws. METHODS: Patients underwent primary THA using either a direct anterior (DA) or a direct lateral (DL) approach. The DA surgeon routinely supplemented cup fixation with 1 or 2 screws while the DL surgeon used no screws. At 7 follow-up visits up to 2 years post operation, patients underwent radiostereometric analysis (RSA) imaging for implant migration tracking. The primary outcome was defined as proximal cup migration measured with model-based RSA. RESULTS: 68 patients were assessed up to 2 years post operation, n = 43 received screws and n = 25 did not. The use of screws had a significant effect on cup migration (p = 0.018). From 2 weeks to 2 years post operation, the total mean migration was 0.403 ± 0.681 mm and 0.129 ± 0.272 mm (p = 0.319) for cups with and without screws, respectively. The number of screws used also had a significant impact, with cups fixated with 1 screw migrating more than cups fixated with 2 (p = 0.013, mean difference 0.712 mm). CONCLUSIONS: Acetabular cups fixated with only 1 screw resulted in greater migration than cups with no screws or 2 screws, though the mean magnitude was well under the 1.0 mm threshold for unacceptable migration. However, 3 of the 24 patients who received only 1 screw exceeded the 1.0 mm threshold for unacceptable migration. Ultimately, the results of this study show that the use of 2 screws to supplement cup fixation can provide good implant stability that is equivalent to a secure press-fit component with no screws.Clinical trial registration: ClinicalTrials.gov (NCT03558217).


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Tornillos Óseos , Estudios de Seguimiento , Diseño de Prótesis , Falla de Prótesis , Análisis Radioestereométrico
6.
J Arthroplasty ; 39(3): 689-694.e3, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37739141

RESUMEN

BACKGROUND: The objective of this study was to identify the rate and risk factors for revision total knee arthroplasty (TKA) within the first 5 years postoperative. Our secondary objective was to identify the rate of additional surgical procedures and death. METHODS: We conducted a retrospective cohort study among patients in Ontario, Canada who underwent an elective, primary TKA between April 1, 2007, and March 31, 2014, for osteoarthritis. We excluded patients under 40 years and who had undergone a TKA within the previous 15 years. Our final study cohort included 94,193 patients. We reported the proportion of the study cohort who experienced revision surgery within 2 and 5 years of the primary TKA; secondary surgery within 5 years. We conducted Cochran-Armitage tests for trends to assess changes in the proportion of patients who experienced each of the study outcomes, and multivariable logistic regressions to evaluate predictors of a revision TKA. RESULTS: There were 3,112 (3.3%) patients who had a revision within 5 years, and 1,866 (2.0%) within 2 years of their primary TKA. 3,316 (3.5%) had a secondary surgery (0.6% patellar resurfacing; 1.6% manipulation; 1.3% synovectomy; 0.5% washout; 0.9% debridement). Lower age, men, lower income, higher comorbidity score, depression, previous arthroscopy, lower surgeon volume, and general anesthesia were all significant positive predictors of revision. CONCLUSIONS: In our study cohort, 2.0% of patients had a revision TKA within 2 years, and 3.3% within 5 years of their primary TKA. Preoperative identification of risk factors may reduce the future prevalence of revision TKAs.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Masculino , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/etiología , Ontario/epidemiología , Reoperación/métodos , Articulación de la Rodilla/cirugía
7.
J Arthroplasty ; 38(6S): S297-S301, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37003457

RESUMEN

BACKGROUND: Hybrid fixation, utilizing diaphyseal press-fit stems and cement fixation in the tibial and femoral metaphyseal areas, has long been a strategy for revision total knee arthroplasty (rTKA). The purpose of this study was to evaluate the clinical outcomes and survivorships of hybrid fixation using a single rTKA revision system with a minimum of 5 years follow-up. METHODS: We reviewed our prospectively collected database to identify 281 patients who underwent rTKA using a single revision system with hybrid fixation and press-fit stems between July 2006 and August 2016. We reviewed the clinical outcome scores, including the Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis index, and Veterans RAND 12 Item Health Survey. We also evaluated the 5 and 10-year survivorships and the indications for reoperations. The cohort had a mean age of 70 years (range, 45.2 to 92.0) and a mean body mass index of 33.4 (range, 17.3 to 55.8). The mean time from rTKA surgery was 11.1 years (range, 5.3 to 15.5). RESULTS: Paired t-test analyses showed significant improvements from preoperative versus postoperative clinical outcome scores (P < .001) for Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis, and Veterans RAND 12 Item Health Survey Physical component. Prosthetic joint infections after index rTKA were the most common failure mode with 29 patients requiring reoperations. Rerevision due to aseptic loosening was uncommon (6 patients) with a cumulative survival rate of 95.2% at 5 years and 94.2% at 10 years. CONCLUSION: The use of this single rTKA system utilizing press fit stems combined with hybrid fixation provided significant improvements in the clinical outcomes and excellent survivorships at 5 and 10 years.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis , Humanos , Anciano , Articulación de la Rodilla/cirugía , Supervivencia , Diseño de Prótesis , Reoperación , Osteoartritis/cirugía , Estudios Retrospectivos , Falla de Prótesis , Resultado del Tratamiento
8.
J Arthroplasty ; 38(7S): S223-S228, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36963526

RESUMEN

BACKGROUND: Subsidence remains a concern when utilizing tapered fluted titanium (TFT) femoral stems and may lead to leg length discrepancy, impingement, instability, and failure to obtain osseointegration. This study aims to compare stem subsidence across 3 modern TFT stems. Our secondary aim was to investigate the influence of bicortical contact or "scratch fit" on subsidence, as well as the role of intraoperative imaging in maximizing bicortical contact and preventing stem subsidence. METHODS: A retrospective review of 271 hip arthroplasties utilizing modern TFT stems at a single institution was performed. Three stem designs were included in the analysis: 1 monoblock TFT stem (n = 91) and 2 modular TFT stems (n = 90; n = 90). Patient demographics, Paprosky femoral bone loss classification, bicortical contact, utilization of intraoperative imaging, and stem subsidence (comparison of initial postoperative radiograph to the latest follow-up radiograph-minimum 3 months) were recorded. RESULTS: There was no statistically significant difference in overall subsidence (P = .191) or the incidence of subsidence >5 millimeters between stems (P = .126). Subgroup analysis based on femoral bone loss grading showed no difference in subsidence between stems. Increased bicortical contact was associated with reduced subsidence (P = .004). Intraoperative imaging was used in 46.5% (126 of 271) of cases; this was not correlated with bicortical contact (P = .673) or subsidence (P = .521). CONCLUSION: All 3 modern TFT stems were highly successful and associated with low rates of subsidence, regardless of modular or monoblock design. Surgeons should select the stem that they feel is most clinically appropriate.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Titanio , Diseño de Prótesis , Reoperación , Fémur/diagnóstico por imagen , Fémur/cirugía , Estudios Retrospectivos
9.
J Arthroplasty ; 38(6S): S355-S362, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36758840

RESUMEN

BACKGROUND: Contact kinematics in total knee arthroplasty (TKA) has been shown to affect tibial component migration. However, previous studies correlating kinematic variables to implant migration were completed with older TKA designs. The goal of this study was to determine if there are associations between contact kinematics and tibial component migration for a cemented, bicruciate stabilized (BCS) TKA system. METHODS: A total of 54 knees implanted with a BCS TKA system were analyzed using radiostereometric analysis (RSA). Patients underwent RSA exams at 2 weeks, 6 weeks, 3 months, 6 months, 1 year, and 2 years post operation to measure tibial component migration. At 1 year, contact kinematics was evaluated during a quasi-static deep knee bend. Linear regression analyses were performed between kinematic variables and migration values. RESULTS: Significant correlations were found between contact kinematics and tibial component migration. Excursion on the lateral condyle was the most consistent variable correlating with implant migration. Six patients had > 0.2 mm migrations from 1 to 2 years post operation indicating continuously migrating tibial components, and most had atypical contact kinematics. CONCLUSION: Kinematics was shown to influence tibial component migration. Reduced lateral excursion, suggesting a more constrained lateral condyle, resulted in greater implant migration. The 6 patients who had continuously migrating tibial components had demographic factors that may limit the ability to endure unintended force transmissions caused by abnormal kinematics. These results highlight the importance of restoring knee kinematics with this BCS TKA design to minimize improper force transmissions and resultant increased implant migrations.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Rango del Movimiento Articular
10.
Arthroplasty ; 4(1): 53, 2022 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-36522686

RESUMEN

BACKGROUND: Posterior-stabilized (PS)-total knee arthroplasty (TKA) arose as an alternative to cruciate-retaining (CR)-TKA in the 1970s. Since then, it has become a popularly utilized TKA design with outcomes comparable to CR-TKA. The post-cam mechanism is unique to PS-TKA as it substitutes the function of the posterior cruciate ligament (PCL). The study aimed to understand the kinematic and laxity changes in PS-TKA with under- and overstuffing of the tibiofemoral joint space with the polyethylene (PE) insert. METHODS: This study employed a hybrid computational-experimental joint motion simulation on a VIVO 6 degrees of freedom (6-DoF) joint motion simulator (AMTI, Watertown, MA, USA). Physical prototypes of a virtually-performed TKA in mechanical alignment (MA) and kinematic alignment (KA) based on cadaveric CT scans and a virtual ligament model were utilized. The reference, understuffed (down 2 mm) and overstuffed (up 2 mm) joint spaces were simulated, neutral flexion and laxity testing loads and motions were performed for each configuration. RESULTS: The PE insert thickness influenced post-cam engagement, which occurred after 60º in the overstuffed configurations, after 60º-75º in the reference configurations and after 75º in the understuffed configurations. The understuffed configurations, compared to the reference configurations, resulted in a mean 2.0º (28%) and 2.0º (31%) increase in the coronal laxity in MA and KA respectively. The overstuffed configurations, compared to the reference configuration, resulted in an increase in the mean joint compressive forces (JCFs) by 73 N (61%) and 77 N (62%) in MA and KA models, respectively. CONCLUSIONS: The under- and overstuffing in PS-TKA alter the kinematics with variable effects. Understuffing decreases the stability, JCFs and inverse with overstuffing. Subtle changes in the PE insert thickness alter the post-cam mechanics.

11.
Can J Surg ; 65(4): E487-E495, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35926882

RESUMEN

BACKGROUND: The direct lateral (DL) approach to total hip arthroplasty is more commonly used than the newer direct anterior (DA) approach. Both approaches use collared or collarless femoral stems. We sought to assess implant stability of stem designs implanted with the DL approach and compare outcomes from this cohort with those of a previously reported cohort of patients who underwent arthroplasty with a DA approach. We also sought to determine if early recovery influences differences in migration. METHODS: Patients underwent total hip arthroplasty using the DL or the DA approach and were randomized to receive either a collared or collarless, cementless femoral stem. On the day of surgery and at 6 follow-up visits through to 1 year, patients underwent supine radiostereometric imaging to track implant migration. At follow-up visits, patients performed an instrumented walking test to assess their functional ability and logged an average daily step count to assess their activity levels. We assessed whether patient function and activity were correlated with migration. RESULTS: Stem design did not have a significant effect on migration for the DL group (p = 0.894). Compared with the DA group, the DL group migrated significantly less for both collared (p = 0.031) and collarless (p = 0.002) stems. Migration was not correlated with function or activity at any time point (p > 0.05). CONCLUSION: Most implant migration occurred from the day of surgery to 2 weeks after the operation and stabilized thereafter, suggesting adequate fixation and a low risk for aseptic loosening in both patient groups.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis
12.
Arch Physiother ; 12(1): 16, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35836298

RESUMEN

BACKGROUND: Research has demonstrated an increased risk of falls after total hip arthroplasty (THA). Yet, people's knowledge on falls risk factors and how falls prevention strategies are being used after THA have not been examined. If a person's knowledge of falls and self-efficacy about falls prevention strategies is low this would indicate a pressing need for interventions to lessen risk. The study objectives were: 1) to determine the falls knowledge and what fall prevention strategies people used after (THA) and 2) to determine the outcomes of a falls risk assessment at 12-months after unilateral THA. METHODS: Overall, 108 people completed the Falls Risk for Older People - Community Setting (FROP-Com) scale, a falls questionnaire (covered occurrence of falls, knowledge on falls risk factors, falls prevention strategies implemented after THA surgery), 6-m Walk Test (6mWT), 30-Second Chair Stand Test (30CST), Timed-up and Go (TUG) Test, and Activities-specific Balance Confidence Scale (ABC). RESULTS: Twenty-five (23.2%) people fell at least once in the 12 months after THA. Scores on the FROP-Com ranged from 2-20 with an average of 8.2 ± 3.6 indicating a mild falls risk. The importance of falling compared to other health concerns was rated as moderate to high (6.8 ± 2.9) and the majority of participants (n = 98, 90.7%) believed falls can be prevented after THA. Total scores on the ABC scale ranged from 30.6% to 100.0% with an average score of 84.4 ± 15.5%, indicating high function. Only 47 people (43.5%) reported receiving falls prevention education. A total of 101 falls prevention strategies were completed by 67 people (62%), the most common strategy was environmental modifications (e.g., installation of grab bars) at 37.4%, while exercise was mentioned by only 2%. The majority of people had functional deficits in 30CST (62%) and TUG (76.9%) at 12-months after unilateral THA. CONCLUSIONS: Almost a quarter of the sample had experienced a fall in the 12-months after THA and functional deficits were common. The majority of the sample had proactively implemented falls prevention strategies after the surgery. Yet importantly, people after THA had limited exposure to falls prevention education and implemented a limited range of prevention strategies.

13.
J Arthroplasty ; 37(11): 2208-2213, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35580767

RESUMEN

BACKGROUND: The aim of this study was to compare the stem alignment and the quality of cement mantle of collarless polished tapered cemented stems inserted through the direct anterior approach (DAA) and the direct lateral approach (DLA). METHODS: A comparative retrospective study of 232 hybrid total hip arthroplasties using a cemented collarless polished tapered stem through either the DAA (n = 147) or DLA (n = 85) was performed. Radiographic evaluation included stem alignment, cement mantle quality, and cement mantle thickness. RESULTS: On anteroposterior radiographs, stems implanted through the DLA were more likely to be in neutral alignment, than those implanted through the DAA (83.5%[n = 71] versus 71.4% [n = 105]; P = <.001). No difference between approaches was noted for stem alignment on lateral radiographs or cement mantle quality. Multivariate analysis revealed factors associated with suboptimal cement mantle and included Dorr type B or C femur as well as male gender. A mean cement mantle thickness ≥2mm was achieved in all Gruen zones for both approaches. CONCLUSION: In our series, the DAA was associated with a higher incidence of coronal plane stem malalignment compared to the DLA when using cemented tapered polished femoral components for total hip arthroplasty. No difference in lateral stem alignment or cement mantle quality was found.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Cementos para Huesos , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos
14.
J Arthroplasty ; 37(11): 2262-2271, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35598759

RESUMEN

BACKGROUND: The prevalence and outcomes of unexpected positive intraoperative cultures (UPC) in presumed aseptic revision total knee arthroplasty (TKA) are unclear. The purpose of this study was to determine the prevalence of UPC and infection-free implant survival in this patient population. Secondly, we aimed to compare the infection-free implant survival between cohorts based on number of UPCs and antibiotic treatment. METHODS: We reviewed our institutional database from 2006 to 2019 for all TKA revisions (n = 1795) to identify all presumed aseptic TKA revisions with intraoperative culture(s). After exclusions, 775 revisions were eligible and those with UPC were included in the Kaplan-Meier analysis to determine infection-free implant survival for the cohorts. RESULTS: The prevalence of UPC was 9.8%. The 2- and 5-year infection-free survival was 97.4% and 95.3%, respectively. The 5-year infection-free survival from the same microorganism as the UPC was 98.7%. Infection-free survival was similar for the 1 versus ≥2 UPC cohorts (P = .416), however was poorer for the cohort treated with antibiotics (P = .021). Only one of 3 subsequent PJI-related implant failures was caused by the same microorganism (polymicrobial) as the UPC. There were no subsequent infections in patients with a single UPC not treated with antibiotics. CONCLUSIONS: The prevalence of UPC was 9.8% and the infection-free implant survival is excellent. Infection-free survivorship from PJI caused by the same UPC microorganism is outstanding. Comparisons between cohorts must be interpreted with caution due to study limitations. A single UPC in patents without other signs of infection does not require antibiotic treatment. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Infecciones Relacionadas con Prótesis , Antibacterianos/uso terapéutico , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Prótesis de la Rodilla/efectos adversos , Prevalencia , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Reoperación/efectos adversos , Estudios Retrospectivos
15.
J Arthroplasty ; 37(6S): S98-S104, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35569919

RESUMEN

BACKGROUND: Implant migration and altered kinematics have been thought to impact patient-reported outcome measures (PROMs) and postoperative patient satisfaction. In this study comparing satisfied and dissatisfied total knee arthroplasty (TKA) patients, we hypothesized that dissatisfied patients will have greater continuous implant migration and that there will be differences in joint kinematics, objective functional measurements, and PROMs between satisfied and dissatisfied patients. METHODS: The Knee Society Score Satisfaction Subsection questions regarding satisfaction with function were used at least 6 months postoperation to split 50 patients into satisfied and dissatisfied groups. Patients underwent radiostereometric analysis to evaluate migration and kinematics. A wearable sensor system obtained objective measurements of patient function during timed up and go tests. PROMs were recorded preoperation and postoperation. RESULTS: No statistically significant differences were found in migration between satisfied and dissatisfied groups. Statistical kinematic differences existed in lateral anteroposterior contact location at 20° and 40° of flexion at 1 year, where the dissatisfied group had more anteriorly located lateral contact. No statistically significant differences were present in objective functional measurements. Satisfied and dissatisfied groups had differing PROMs at 4 timepoints or greater for each questionnaire. CONCLUSIONS: No differences were found in tibial component migration or objectively measured function between satisfied and dissatisfied patients. Functionally dissatisfied patients had more anteriorly positioned contact on the lateral condyle in early flexion and reported more pain and unmet expectations. These findings suggest that improving the functional satisfaction of TKA requires restoration of kinematics in early flexion and management of patient's pain and expectations.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Dolor/cirugía , Satisfacción del Paciente , Satisfacción Personal , Rango del Movimiento Articular
16.
J Arthroplasty ; 37(6S): S263-S269, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35257822

RESUMEN

BACKGROUND: Bone loss remains an anticipated challenge in revision total knee arthroplasty (rTKA). Recent efforts to enhance rTKA fixation and stability have focused on metaphyseal implants, namely cones and sleeves. We sought to compare cone and sleeve implant survivorship in rTKA. METHODS: One hundred eighty patients who underwent rTKA with metaphyseal implants from 2005 to 2018 were retrospectively reviewed. A total of 83 cones (22 femoral, 62 tibial) and 121 sleeves (58 femoral, 63 tibial) were identified. The mean age at the time of surgery was 72 years (range 43-97). Intraoperative Anderson Orthopaedic Research Institute bone loss classifications included the following: type 2A (25), type 2B (98), and type 3 (81). Mean follow-up was 41 months. RESULTS: Revision-free survival for cones was 91.3% vs 92.2% for sleeves (P = .29). Twelve knees (4 cones, 8 sleeves) underwent irrigation, debridement, and polyethylene exchange with metaphyseal implant retention for acute postoperative periprosthetic joint infection (PJI). Development of chronic PJI warranted removal of 7 cones (8.4%), 6 of which were initially placed as part of a 2-stage revision TKA. Eight sleeves (6.6%) were removed for PJI, with all initially placed during a second stage reimplantation. In the absence of infection, survival was 100% and 99.1% for cones and sleeves, respectively. One sleeve was revised for periprosthetic fracture. CONCLUSION: Metaphyseal cones and sleeves offer equally durable survivorship in revision TKA. PJI was the most common mode of implant failure in this series. Importantly, no cases of cone or sleeve aseptic loosening were observed.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Adulto , Anciano , Anciano de 80 o más Años , Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Persona de Mediana Edad , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Supervivencia
17.
J Arthroplasty ; 37(2): 252-258, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34710566

RESUMEN

BACKGROUND: The goal of this study is to investigate the migration and inducible displacement of a bicruciate-stabilized (BCS) total knee arthroplasty implanted using gap balancing (GB) or measured resection (MR) surgical techniques. We hypothesized equal migration and displacement between the techniques. METHODS: The study is a single-blinded, prospective, randomized controlled trial, with allocation of 71 patients to either GB or MR groups. Fifteen patients were withdrawn, resulting in 31 patients in the GB group and 25 in the MR group. Patients received the JOURNEY II™ BCS implant. Migration and inducible displacement were evaluated using radiostereometric analysis and patient examinations were performed at a 2-week baseline, and at 6 weeks, 3 months, 6 months, 1 year, and 2 years postoperation. RESULTS: No differences (P > .05) existed between GB and MR groups for any measurement of tibial or femoral migration. Both groups had tibial migrations below 0.5 mm from baseline to 6 months, and below 0.2 mm from both 6 months to 1 year and 1-2 years postoperation. No differences (P > .05) were found between GB and MR groups for inducible displacement. CONCLUSION: No differences were found in implant migration or inducible displacement between GB and MR groups. The BCS implant can be expected to have migration risks on par with industry standards and both surgical techniques are safe and effective options for implantation of this implant design.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Análisis Radioestereométrico , Tibia/diagnóstico por imagen , Tibia/cirugía
18.
PLoS One ; 16(9): e0257471, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34520499

RESUMEN

16S rRNA gene sequencing of DNA extracted from clinically uninfected hip and knee implant samples has revealed polymicrobial populations. However, previous studies assessed 16S rRNA gene sequencing as a technique for the diagnosis of periprosthetic joint infections, leaving the microbiota of presumed aseptic hip and knee implants largely unstudied. These communities of microorganisms might play important roles in aspects of host health, such as aseptic loosening. Therefore, this study sought to characterize the bacterial composition of presumed aseptic joint implant microbiota using next generation 16S rRNA gene sequencing, and it evaluated this method for future investigations. 248 samples were collected from implants of 41 patients undergoing total hip or knee arthroplasty revision for presumed aseptic failure. DNA was extracted using two methodologies-one optimized for high throughput and the other for human samples-and amplicons of the V4 region of the 16S rRNA gene were sequenced. Sequencing data were analyzed and compared with ancillary specific PCR and microbiological culture. Computational tools (SourceTracker and decontam) were used to detect and compensate for environmental and processing contaminants. Microbial diversity of patient samples was higher than that of open-air controls and differentially abundant taxa were detected between these conditions, possibly reflecting a true microbiota that is present in clinically uninfected joint implants. However, positive control-associated artifacts and DNA extraction methodology significantly affected sequencing results. As well, sequencing failed to identify Cutibacterium acnes in most culture- and PCR-positive samples. These challenges limited characterization of bacteria in presumed aseptic implants, but genera were identified for further investigation. In all, we provide further support for the hypothesis that there is likely a microbiota present in clinically uninfected joint implants, and we show that methods other than 16S rRNA gene sequencing may be ideal for its characterization. This work has illuminated the importance of further study of microbiota of clinically uninfected joint implants with novel molecular and computational tools to further eliminate contaminants and artifacts that arise in low bacterial abundance samples.


Asunto(s)
Bacterias/aislamiento & purificación , Microbiota , Infecciones Relacionadas con Prótesis/microbiología , Adulto , Anciano , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Artefactos , Bacterias/genética , Femenino , Articulación de la Cadera/microbiología , Humanos , Articulación de la Rodilla/microbiología , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa , Infecciones Relacionadas con Prótesis/patología , ARN Ribosómico 16S/química , ARN Ribosómico 16S/genética , ARN Ribosómico 16S/metabolismo , Análisis de Secuencia de ADN
19.
J Bone Joint Surg Am ; 103(15): 1392-1401, 2021 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-33974575

RESUMEN

BACKGROUND: The prevalence and outcomes of unexpected positive cultures (UPCs) of specimens taken during presumed aseptic revision total hip arthroplasty (THA) are unclear. The purpose of this study was to determine the prevalence of UPC and infection-free implant survival in this patient population. Secondary aims included identifying factors associated with subsequent infection-related failure in patients with UPC. METHODS: We reviewed all THA revisions (n = 2,288) performed at our institution from 2006 to 2019. Presumed aseptic revision THAs with intraoperative culture(s) were eligible (n = 1,196), and those with UPC were included in a Kaplan-Meier analysis to determine the infection-free implant survival and in Cox regression analysis to identify factors associated with infection-related failure. RESULTS: UPC(s) were documented for 9.2% (110) of 1,196 aseptic THA revisions. The 2- and 5-year infection-free implant survival in the entire UPC cohort was 93.1% (95% confidence interval [CI] = 90.5% to 95.7%) and 86.8% (95% CI = 82.9% to 90.7%), respectively. The 2- and 5-year infection-free survival with failure due to infection with the same microorganism as identified in the UPC as the end point was 95.8% (95% CI = 93.7% to 97.9%) and 94.3% (95% CI = 91.7% to 96.9%), respectively. Subsequent infection-related failures caused by the same microorganism as identified in the UPC were more likely to occur after revisions with ≥2 UPCs than after those with 1 UPC (p = 0.024). Revision due to adverse metal reaction was a risk factor for subsequent infection-related failure (hazard ratio [HR] = 14.49, 95% CI = 2.69 to 78.04). Patients with a single UPC who were not treated with antibiotics had no subsequent periprosthetic joint infections (PJIs) caused by the same microorganism as identified in the UPC. CONCLUSIONS: The prevalence of UPC was 9.2%, and the infection-free implant survival in patients with UPC is encouraging. Implant survival free of PJI caused by the same microorganism as identified in the UPC was excellent. Aseptic revision for adverse metal reaction was a risk factor for subsequent PJI in patients with UPC. No patient with a single UPC who was not treated with antibiotics developed PJI caused by the UPC-identified microorganism, suggesting that in the absence of other signs of infection a single UPC does not warrant antibiotic treatment. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artritis Infecciosa/epidemiología , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Falla de Prótesis , Infecciones Relacionadas con Prótesis/epidemiología , Reoperación/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Artritis Infecciosa/diagnóstico , Artritis Infecciosa/microbiología , Femenino , Prótesis de Cadera/efectos adversos , Prótesis de Cadera/microbiología , Humanos , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Prevalencia , Propionibacteriaceae/aislamiento & purificación , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Estudios Retrospectivos
20.
J Arthroplasty ; 36(9): 3078-3088, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34053752

RESUMEN

BACKGROUND: Patient-specific instrumentation (PSI) has been introduced in total knee arthroplasty (TKA) with the goal of increased accuracy of component positioning by custom fitting cutting guides to the patient's bony anatomy. A criticism of this technology is the associated cost. The purpose of this randomized controlled trial was to determine the cost-utility of PSI compared with standard of care (SOC) instrumentation for TKA in an obese population. METHODS: Patients with body mass index greater than 30 with osteoarthritis and undergoing primary TKA were randomized to SOC or PSI. Patients completed a health care resource use diary and the EuroQol-5D at three, six, nine, and 12 months and the Western Ontario and McMaster Universities Osteoarthritis Index at three and 12 months postsurgery. We performed cost-utility and cost-effectiveness analyses from public health care payer and societal perspectives. RESULTS: One hundred seventy-three patients were included in the analysis with 86 patients randomized to PSI and 87 to SOC. PSI was dominated (more costly and less effective) by SOC from a health care payer perspective. From a societal perspective, an incremental cost-utility ratio was calculated at $11,230.00 per quality-adjusted life year gained, which is cost-effective at a willingness to pay threshold of $50,000. Net benefit analyses found PSI was not significantly cost-effective at any willingness to pay value from either perspective. CONCLUSION: Our results suggest that widespread adoption of PSI may not be economically attractive or clinically indicated. Future considerations are to compare long-term clinical outcomes and radiographic alignment between the groups.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Osteoartritis , Análisis Costo-Beneficio , Humanos , Articulación de la Rodilla/cirugía , Obesidad/complicaciones , Obesidad/cirugía , Osteoartritis de la Rodilla/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA