Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Diabetes Care ; 2024 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-39452893

RESUMEN

Continuous glucose monitoring (CGM) systems provide frequent glucose measurements in interstitial fluid and have been used widely in ambulatory settings for diabetes management. During the coronavirus disease 2019 (COVID-19) pandemic, regulators in the U.S. and Canada temporarily allowed for CGM systems to be used in hospitals with the aim of reducing health care professional COVID-19 exposure and limiting use of personal protective equipment. As such, studies on hospital CGM system use have been possible. With improved sensor accuracy, there is increased interest in CGM usage for diabetes management in hospitals. Laboratorians and health care professionals must determine how to integrate CGM usage into practice. The aim of this consensus guidance document is to provide an update on the application of CGM systems in hospital, with insights and opinions from laboratory medicine, endocrinology, and nursing.

2.
Clin Biochem ; : 110835, 2024 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-39442856

RESUMEN

OBJECTIVES: This study aimed to employ big data analysis to harmonize reference intervals (RI) for thyroid function tests, with refinement to the TSH upper reference limit, and to optimize the TSH reflex algorithm to improve clinical management and test utilization. DESIGN & METHODS: TSH, free T4, and free T3 results tested in Alberta, Canada, on Roche Cobas and Siemens Atellica were extracted from the laboratory information system (N = 1,144,155 for TSH, N = 183,354 for free T4 and N = 92,632 for free T3). Results from specialists, inpatients, or repeat testing, as well as from positive thyroid disease, autoimmune disease, and pregnancy biomarkers were excluded. RIs were derived using statistical models (Bhattacharya, refineR, and simple non-parametric) followed by endocrinology and laboratory review. RESULTS: The TSH RIs for 0 to 7 days, 8 days to 1 year, and ≥1 year were 1.23 to 25.0 mIU/L, 1.00 to 6.80 mIU/L and 0.20 to 6.50 mIU/L, respectively. The free T4 RIs for 0 to 14 days, 15 to 29 days, and ≥30 days were 13.5 to 50.0 pmol/L, 8.7 to 32.5 pmol/L, and 10.0 to 25.0 pmol/L, respectively. An updated TSH reflex algorithm was developed based on the optimized TSH and free T4 RIs, with free T4 reflexed only at a TSH of <0.1 mIU/L. CONCLUSIONS: The collaboration of a multidisciplinary team and the utilization of big data analysis led to the enhancement of thyroid function RIs, specifically resulting in the widening of the upper TSH reference limit to 6.50. Application of these optimized RIs with the TSH reflex algorithm will serve as a guide for improvement in interpretation of thyroid function tests.

3.
Can J Cardiol ; 40(7): 1183-1197, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38336003

RESUMEN

Detecting dyslipidemia early is important because atherosclerosis originates in childhood and early treatment can improve outcomes. In 2022, the Canadian Cardiovascular Society (CCS) and Canadian Pediatric Cardiology Association (CPCA) published a clinical practice update to detect, evaluate, and manage pediatric dyslipidemia. However, guidance on its translation into clinical laboratories is lacking. The Canadian Society of Clinical Chemists Working Group on Reference Interval Harmonization Lipid Team aims to assist guideline implementation and promote harmonized pediatric lipid reporting across Canada. The 2022 CCS/CPCA clinical practice update, 2011 National Heart, Lung, and Blood Institute integrated guidelines, and new data analysis (Canadian pediatric reference values from the Canadian Laboratory Initiative on Pediatric Reference Intervals [CALIPER] and retrospective patient data from large community laboratories) were incorporated to develop 5 key recommendations. These include recommendations to: (1) offer nonfasting and fasting lipid testing; (2) offer a lipid panel including total cholesterol, low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), non-HDL-C, and triglycerides, with apolipoprotein B and lipoprotein(a) available as individually orderable tests; (3) flag total cholesterol, LDL-C, and non-HDL-C results ≥ 95th percentile, and HDL-C results < 10th percentile, as recommended by CCS/CPCA/National Heart, Lung, and Blood Institute and validated by CALIPER, and flag apolipoprotein B and nonfasting triglyceride results ≥ 95th percentile on the basis of CALIPER, and do not flag Lp(a) results but mention the adult cutoff in the interpretive comments; (4) implement interpretive comments listed in the current report; and (5) implement the National Institutes of Health LDL-C equation. The Canadian Society of Clinical Chemists Working Group on Reference Interval Harmonization Lipid Team will support clinical laboratories to implement these recommendations using knowledge translation strategies. Harmonizing pediatric lipid reporting across Canadian clinical laboratories will optimize clinical decision-making and improve cardiovascular risk management in youth.


Asunto(s)
Dislipidemias , Lípidos , Humanos , Canadá , Niño , Lípidos/sangre , Dislipidemias/diagnóstico , Dislipidemias/sangre , Sociedades Médicas , Valores de Referencia
4.
Clin Chem ; 69(9): 991-1008, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37478022

RESUMEN

BACKGROUND: Harmonization in laboratory medicine is essential for consistent and accurate clinical decision-making. There is significant and unwarranted variation in reference intervals (RIs) used by laboratories for assays with established analytical traceability. The Canadian Society of Clinical Chemists (CSCC) Working Group on Reference Interval Harmonization (hRI-WG) aims to establish harmonized RIs (hRIs) for laboratory tests and support implementation. METHODS: Harnessing the power of big data, laboratory results were collected across populations and testing platforms to derive common adult RIs for 16 biochemical markers. A novel comprehensive approach was established, including: (a) analysis of big data from community laboratories across Canada; (b) statistical evaluation of age, sex, and analytical differences; (c) derivation of hRIs using the refineR method; and (d) verification of proposed hRIs across 9 laboratories with different instrumentation using serum and plasma samples collected from healthy Canadian adults. RESULTS: Harmonized RIs were calculated for all assays using the refineR method, except free thyroxine. Derived hRIs met proposed verification criterion across 9 laboratories and 5 manufacturers for alkaline phosphatase, albumin (bromocresol green), chloride, lactate dehydrogenase, magnesium, phosphate, potassium (serum), and total protein (serum). Further investigation is needed for some analytes due to failure to meet verification criteria in one or more laboratories (albumin [bromocresol purple], calcium, total carbon dioxide, total bilirubin, and sodium) or concern regarding excessively wide hRIs (alanine aminotransferase, creatinine, and thyroid stimulating hormone). CONCLUSIONS: We report a novel data-driven approach for RI harmonization. Findings support feasibility of RI harmonization for several analytes; however, some presented challenges, highlighting limitations that need to be considered in harmonization and big data analytics.


Asunto(s)
Ciencia de los Datos , Laboratorios , Adulto , Humanos , Valores de Referencia , Canadá , Albúminas
5.
Clin Chem Lab Med ; 61(7): 1280-1287, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-37043622

RESUMEN

OBJECTIVES: Monitoring quality indicators (QIs) is an important part of laboratory quality assurance (QA). Here, the Canadian Society of Clinical Chemists (CSCC) Point of Care Testing (POCT) and QI Special Interest Groups describe a process for establishing and monitoring QIs for POCT glucose testing. METHODS: Key, error prone steps in the POCT glucose testing process were collaboratively mapped out, followed by risk assessment for each step. Steps with the highest risk and ability to detect a non-conformance were chosen for follow-up. These were positive patient identification (PPID) and repeat of critically high glucose measurements. Participating sites were asked to submit aggregate data for these indicators from their site(s) for a one-month period. The PPID QI was also included as part of a national QI monitoring program for which fifty-seven sites submitted data. RESULTS: The percentage of POCT glucose tests performed without valid PPID ranged from 0-87%. Sites without Admission-Discharge-Transfer (ADT) connectivity to POCT meters were among those with the highest percentage of POCT glucose tests performed without valid PPID. The percentage repeated critically high glucose measurements ranged from 0-50%, indicating low compliance with this recommendation. A high rate of discordance was also noted when critically high POCT glucose measurements were repeated, demonstrating the importance of repeat testing prior to insulin administration. CONCLUSIONS: Here, a process for establishing these QIs is described, with preliminary data for two QIs chosen from this process. The findings demonstrate the importance of QIs for identification and comparative performance monitoring of non-conformances to improve POCT quality.


Asunto(s)
Glucosa , Sistemas de Atención de Punto , Indicadores de Calidad de la Atención de Salud , Canadá , Opinión Pública , Glucosa/química , Pruebas en el Punto de Atención , Humanos
6.
J Med Microbiol ; 72(2)2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36848403

RESUMEN

Introduction. Starting in December, 2020, the ID NOW was implemented throughout the province of Alberta, Canada (population 4.4 million) in various settings.Gap statement. ID NOW's test performance with SARS-CoV-2 Omicron variant BA.1 is unknown.Aim. To assess the ID NOW performance among symptomatic individuals during the BA.1 Omicron wave and compare it to previous SARS-CoV-2 variant waves.Methodology. The ID NOW was assessed in two locations among symptomatic individuals: rural hospitals and community assessment centres (AC) during the period 5-18 January 2022. Starting 5 January, Omicron represented >95 % of variants detected in our population. For every individual tested, two swabs were collected: one for ID NOW testing and the other for either reverse-transcriptase polymerase chain reaction (RT-PCR) confirmation of negative ID NOW results or for variant testing of positive ID NOW results.Results. A total of 3041 paired samples were analysed (1139 RT-PCR positive). From this, 1873 samples were from 42 COVID-19 AC and 1168 from 69 rural hospitals. ID NOW sensitivity for symptomatic individuals presenting to community AC and rural hospitals was 96.0 % [95 % confidence interval (CI) 94.5-97.3 %, n=830 RT-PCR positive], and 91.6 % (95 % CI 87.9-94.4 %, n=309 RT-PCR positive), respectively. SARS-CoV-2 positivity rate was very high for both populations (44.3 % at AC, 26.5 % in hospital).Conclusions. Sensitivity of ID NOW SARS-CoV-2, compared to RT-PCR, is very high during the BA.1 Omicron wave, and is significantly higher when compared to previous SARS-CoV-2 variant waves.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiología , SARS-CoV-2/genética , Canadá , Hospitales
7.
Clin Biochem ; 111: 60-65, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36279904

RESUMEN

BACKGROUND: Blood gas analyzers employing glucose-oxidase biosensors under-recover glucose when pO2 is low. The manufacturer of the GEM®Premier™ series of analyzers introduced an algorithm to detect specimens at risk of low pO2 interference. We investigated the reliability of this algorithm. METHODS: Whole blood specimens were tested by GEM®Premier™ 4000 (GEM 4000) and 5000 (GEM 5000). Specimens with an incalculable ("incalc") error code for glucose result or that had a glucose ≥ 20 mmol/L were retested on a second analyzer of the same type within 5 min over the course of 30 months in 5 hospitals in Calgary, Alberta. Discordant retests were defined as either: 1) paired numeric results with a difference >10 %, or 2) an "incalc" code that yielded a numeric result upon retesting. Glucose recovery in relation to pO2 level was assessed by comparing specimens experimentally depleted of pO2 between GEM 5000 and a laboratory analyzer (Siemens Vista®). RESULTS: Of 1,776 glucose tests repeated on the GEM 5000 or 1,544 on GEM 4000, 10% were discordant. GEM 5000 produced twice as many discordant numeric retests versus the GEM 4000 [5.9% (98/1,651) vs 2.7% (38/1,391)]. The majority of "incalc" error codes repeated with a numeric glucose result on both GEM analyzers [(79.7% (122/153) vs 75.2% (94/125)]. Among specimens experimentally depleted of pO2, the GEM 5000 under-recovered glucose by up to 30% compared to the Siemens Vista and were not flagged by an "incalc" code. CONCLUSIONS: The algorithm in the GEM®PremierTM series of analyzers that flags specimens at risk for glucose under-recovery due to low pO2 does not reliably detect specimens at risk for glucose under-recovery.


Asunto(s)
Glucosa , Oxígeno , Humanos , Presión Parcial , Reproducibilidad de los Resultados , Sistemas de Atención de Punto , Análisis de los Gases de la Sangre/métodos , Glucemia
8.
Clin Microbiol Infect ; 29(2): 247-252, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36096431

RESUMEN

OBJECTIVE: Diagnostic evaluation of the ID NOW coronavirus disease 2019 (COVID-19) assay in various real-world settings among symptomatic and asymptomatic individuals. METHODS: Depending on the setting, the ID NOW testing was performed using oropharyngeal swabs (OPSs) taken from patients with symptoms suggestive of COVID-19, asymptomatic close contacts, or asymptomatic individuals as part of outbreak point prevalence screening. From January to April 2021, a select number of sites switched from using OPS to combined oropharyngeal and nasal swab (O + NS) for ID NOW testing. For every individual tested, two swabs were collected by a health care worker: one swab (OPS or O + NS) for ID NOW testing and a separate swab (OPS or nasopharyngeal swab) for RT-PCR. RESULTS: A total of 129 112 paired samples were analysed (16 061 RT-PCR positive). Of these, 81 697 samples were from 42 COVID-19 community collection sites, 16 924 samples were from 69 rural hospitals, 1927 samples were from nine emergency shelters and addiction treatment facilities, 23 802 samples were from six mobile units that responded to 356 community outbreaks, and 4762 O + NS swabs were collected from three community collection sites and one emergency shelter. The ID NOW assay sensitivity was the highest among symptomatic individuals presenting to community collection sites (92.5%; 95% CI, 92.0-93.0%) and the lowest for asymptomatic individuals associated with community outbreaks (73.9%; 95% CI, 69.8-77.7%). Specificity was >99% in all populations tested. DISCUSSION: The sensitivity of ID NOW severe acute respiratory syndrome coronavirus 2 testing is the highest when used in symptomatic community populations not seeking medical care. Sensitivity and positive predictive value drop by approximately 10% when tested on asymptomatic populations. Using combined oropharyngeal and nasal swabs did not improve the performance of ID NOW assay.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiología , Prueba de COVID-19 , Técnicas de Laboratorio Clínico , Estudios Prospectivos , Manejo de Especímenes , Sensibilidad y Especificidad , Nasofaringe
9.
Expert Rev Mol Diagn ; 22(8): 797-809, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-36093682

RESUMEN

INTRODUCTION: Detection of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) has been critical to support and management of the COVID-19 pandemic. Point of care testing (POCT) for SARS-CoV-2 has been a widely used tool for detection of SARS-CoV-2. AREAS COVERED: POCT nucleic acid amplification tests (NAATs) and rapid antigen tests (RATs) have been the most readily used POCT for SARS-CoV-2. Here, current knowledge on the utility of POCT NAATs and RATs for SARS-CoV-2 are reviewed and discussed alongside aspects of quality assurance factors that must be considered for successful and safe implementation of POCT. EXPERT OPINION: Use cases for implementation of POCT must be evidence based, regardless of the test used. A quality assurance framework must be in place to ensure accuracy and safety of POCT.


Asunto(s)
COVID-19 , COVID-19/diagnóstico , Prueba de COVID-19 , Humanos , Pandemias , Sistemas de Atención de Punto , Pruebas en el Punto de Atención , SARS-CoV-2 , Sensibilidad y Especificidad
10.
Can J Cardiol ; 38(8): 1180-1188, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35378262

RESUMEN

There is limited guidance on laboratory reporting and interpretation of lipids and lipoproteins used in cardiovascular risk stratification. This contributes to inconsistencies in lipid reporting across clinical laboratories. Recently, the Canadian Cardiovascular Society (CCS) published the 2021 CCS guidelines for the management of dyslipidemia for the prevention of cardiovascular disease in the adult. A subcommittee of the Working Group on Reference Interval Harmonization of the Canadian Society of Clinical Chemists has developed harmonized lipid reporting recommendations that are aligned with the 2021 CCS guidelines, to improve the standardization of lipid assessment and clinical decision-making. The proposed harmonized lipid reporting recommendations were critically reviewed by a broad range of laboratory and clinical experts across Canada. Feedback from approximately 30 expert reviewers was reviewed by the Working Group on Reference Interval Harmonization lipid subcommittee, and consensus decisions were incorporated into the 2021 harmonized lipid reporting recommendations. In this position statement, we provide 6 recommendations for laboratory reporting of lipid parameters. These recommendations include implementing the new National Institutes of Health equation to replace the Friedewald equation for calculating low-density lipoprotein cholesterol, offering lipoprotein (a), either as an in-house or send-out test, and using assays that report lipoprotein (a) in molar units (nmol/L). We also developed a harmonized lipid reporting format with interpretive comments that includes flagging results based on screening patients using treatment decision thresholds in a primary prevention setting. Overall, harmonized lipid reporting will help bridge the gap between clinical guideline recommendations and clinical laboratory reporting and interpretation, and will improve cardiovascular risk assessment across Canada.


Asunto(s)
Dislipidemias , Laboratorios Clínicos , Lípidos , Adulto , Canadá/epidemiología , Enfermedades Cardiovasculares/prevención & control , Dislipidemias/diagnóstico , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Laboratorios Clínicos/normas , Lípidos/análisis , Lipoproteína(a)
12.
J Virus Erad ; 7(3): 100052, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34557308

RESUMEN

BACKGROUND: Cytomegalovirus (CMV) end-organ disease (EOD) continues to pose a significant risk to patients with advanced HIV disease despite decreased incidence with combination anti-retroviral therapy (ART) and lower mortality with effective anti-CMV therapy. Subclinical CMV shedding may also contribute to ongoing inflammation and non-infectious comorbidities. METHODS: We examined the occurrence of CMV EOD and CMV shedding in a cohort of patients participating in a prospective observational study of severely immunosuppressed (CD4 ≤100 cells/µl), ART-naïve, HIV-1 infected adult participants. RESULTS: We studied 206 participants, of whom 193 (93.7%) were CMV IgG positive. Twenty-five participants (12.1%) developed confirmed CMV EOD. At baseline, 47 (22.8%) had CMV viremia detectable by PCR in the absence of clinical disease (CMV viremia). The remaining 134 (65%) had neither CMV EOD nor CMV viremia detected at baseline. Five participants with CMV EOD (2.4% of total cohort, 20% of CMV EOD) met AIDS Clinical Trials Group criteria for CMV immune reconstitution inflammatory syndrome (IRIS). Only one-third of CMV EOD patients had retinitis, while two-thirds presented with histologically confirmed gastrointestinal illness. CMV viremia was associated with higher percentages of activated CD8+ T cells even after HIV suppression. CONCLUSION: The manifestations of CMV EOD in advanced HIV disease before and after initiation of ART may be more diverse than previously described, with high incidence of gastrointestinal illness. Recognition and treatment of unusual clinical presentations of CMV infection remains important in reducing morbidity and mortality from HIV co-infections.

13.
J Clin Microbiol ; 59(11): e0141121, 2021 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-34288728

RESUMEN

Frequent screening of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) among asymptomatic populations using antigen-based point-of-care tests (APOCTs) is occurring globally with limited clinical performance data. The positive predictive value (PPV) of two APOCTs used in the asymptomatic screening of SARS-CoV-2 among health care workers (HCWs) at continuing care (CC) sites across AB, Canada, was evaluated. Between 22 February and 2 May 2021, CC sites implemented SARS-CoV-2 voluntary screening of their asymptomatic HCWs. On-site testing with Abbott Panbio or BD Veritor occurred on a weekly or twice-weekly basis. Positive APOCTs were confirmed with a real-time reverse transcriptase PCR (rRT-PCR) reference method. A total of 71,847 APOCTs (17,689 Veritor and 54,158 Panbio) were performed among 369 CC sites. Eighty-seven (0.12%) APOCTs were positive, of which 39 (0.05%) were confirmed as true positives using rRT-PCR. Use of the Veritor and Panbio resulted in 76.6% and 30.0% false-positive detection, respectively (P < 0.001). This corresponded to PPVs of 23.4 and 70.0% for the Veritor and Panbio, respectively. Frequent screening of SARS-CoV-2 among asymptomatic HCWs in CC, using APOCTs, resulted in a very low detection rate and a high rate of detection of false positives. Careful assessment of the risks versus benefits of APOCT programs and the prevalence of infection in this population needs to be thoroughly considered before implementation.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Pruebas en el Punto de Atención , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
14.
Pract Lab Med ; 25: e00216, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33869709

RESUMEN

OBJECTIVES: Point of Care Testing (POCT) is a rapidly expanding area of clinical laboratory testing and quality assurance is an important area of focus. Quality indicators (QIs) are a quality management system tool that monitors aspects of the testing process to help meet the challenges associated with maintaining high quality patient safety given the growth in POCT. Alberta aims to formalize the development and use of QIs for POCT. DESIGN: and Methods: Potential QIs were identified by reviewing both the current standards and guidelines for QIs in POCT, and the research regarding quality and sources of error in POCT. Quality practices and potential sources of error in POCT were identified by: 1) a Canadian national survey on POCT, and 2) direct observation in two local POCT programs. RESULTS: A proposed selection of QIs in POCT were identified by incorporating the results from these investigations, while considering the unique characteristics of POCT. These QIs monitor the preanalytical, analytical, and post-analytical phases of testing, and support processes. CONCLUSIONS: As POCT volumes and test menu expands, QIs will be a vital tool in monitoring error and maintaining high quality of results. Adoption of formal QIs will support continuous quality improvement and improved patient care.

16.
Eur J Clin Microbiol Infect Dis ; 40(8): 1721-1726, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33742322

RESUMEN

SARS-CoV-2 antigen tests used at the point-of-care, such as the Abbott Panbio, have great potential to help combat the COVID-19 pandemic. The Panbio is Health Canada approved for the detection of SARS-CoV-2 in symptomatic individuals within the first 7 days of COVID-19 symptom onset(s). Symptomatic adults recently diagnosed with COVID-19 in the community were recruited into the study. Paired nasopharyngeal (NP), throat, and saliva swabs were collected, with one paired swab tested immediately with the Panbio, and the other transported in universal transport media and tested using real-time reverse-transcriptase polymerase chain reaction (RT-PCR). We also prospectively evaluated results from assessment centers within the community. For those individuals, an NP swab was collected for Panbio testing and paired with RT-PCR results from parallel NP or throat swabs. One hundred and forty-five individuals were included in the study. Collection of throat and saliva was stopped early due to poorer performance (throat sensitivity 57.7%, n=61, and saliva sensitivity 2.6%, n=41). NP swab sensitivity was 87.7% [n=145, 95% confidence interval (CI) 81.0-92.7%]. There were 1641 symptomatic individuals tested by Panbio in assessment centers with 268/1641 (16.3%) positive for SARS-CoV-2. There were 37 false negatives and 2 false positives, corresponding to a sensitivity and specificity of 86.1% [95% CI 81.3-90.0%] and 99.9% [95% CI 99.5-100.0%], respectively. The Panbio test reliably detects most cases of SARS-CoV-2 from adults in the community setting presenting within 7 days of symptom onset using nasopharyngeal swabs. Throat and saliva swabs are not reliable specimens for the Panbio.


Asunto(s)
Prueba de COVID-19 , COVID-19/diagnóstico , Nasofaringe/virología , Faringe/virología , Saliva/virología , Adulto , Anciano , Anciano de 80 o más Años , Canadá , Reacciones Falso Negativas , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Manejo de Especímenes
17.
Can J Cardiol ; 37(6): 933-937, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33775880

RESUMEN

To effectively implement the Canadian Cardiovascular Society (CCS) guidelines for dyslipidemia management into clinical laboratories, clear recommendations for lipid reporting are essential. In this study, the Canadian Society of Clinical Chemists Working Group on Reference Interval Harmonisation surveyed Canadian laboratories on adult lipid reporting practices to set a foundation for the development and implementation of harmonised lipid reporting across Canada. Key aspects of the survey asked laboratories: what reporting parameters were in place to assess lipid results; what interpretative comments were provided; whether nonfasting lipids were permitted and, if so, what strategy was used to document fasting status; and whether there was interest in implementing a harmonised lipid report. A total of 101 laboratories were represented by 24 respondents, as many responses were submitted by laboratory networks that included more than 1 laboratory. There was at least 1 response from 9 Canadian provinces and representation across 5 testing platforms. Upper and lower limits for lipid parameters and referenced source of limits varied substantially across laboratories, with only 56% of laboratories (9 respondents) referencing the 2016 CCS guidelines. Eighty-six percent of laboratories (19 respondents) report nonfasting lipids, although the method of documenting nonfasting status varied. Overall, 36% of laboratories (8 respondents) reported interest in implementing a harmonised lipid report. Assessment of current lipid-reporting practices supports the need for harmonised lipid reporting across Canada. Development of a harmonised lipid report for the adult population, consistent with up-to-date Canadian guidelines, will improve continuity of lipid test interpretation across Canada and improve clinical decision making.


Asunto(s)
Servicios de Laboratorio Clínico , Dislipidemias , Lípidos , Manejo de Atención al Paciente , Canadá/epidemiología , Servicios de Laboratorio Clínico/organización & administración , Servicios de Laboratorio Clínico/normas , Dislipidemias/sangre , Dislipidemias/epidemiología , Dislipidemias/terapia , Necesidades y Demandas de Servicios de Salud , Humanos , Lípidos/análisis , Lípidos/sangre , Manejo de Atención al Paciente/métodos , Manejo de Atención al Paciente/normas , Mejoramiento de la Calidad , Estándares de Referencia , Valores de Referencia , Proyectos de Investigación
18.
Pract Lab Med ; 24: e00206, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33598521

RESUMEN

OBJECTIVES: Quality assurance (QA) plays an integral role in Point of Care Testing (POCT) programs. Quality control (QC) is an important QA program component to ensure high quality results and enhanced patient care. The measurement of transcutaneous bilirubin (TcB) in the POCT setting is an essential part of newborn care in Alberta, Canada. However, there is currently no available commercial QC material for TcB meters. An in-house developed QC material has been in use within a single TcB POCT program within Alberta. The objective of this study was to determine the performance of this QC material by other POCT staff and clinical end-users to assess whether its use could be expanded. DESIGN AND METHODS: Two levels of QC material were measured by POCT staff and clinical end-users across 12 different sites using the Dräger Jaundice Meter JM-103® and JM-105® meters. RESULTS: The performance of the QC material was acceptable when tested by POCT staff, was stable and reliable over time, and had an acceptable CV (≤8%). However, the data does not support use of the QC material by clinical end-users. CONCLUSIONS: The use of the QC material could be expanded into other TcB settings for use by POCT staff. Additional training and experience with the QC material by end-users is needed to facilitate QC use in the clinical setting.

19.
Clin Biochem ; 88: 11-17, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33264650

RESUMEN

Point of Care Testing (POCT) refers to clinical laboratory testing performed outside the central laboratory, nearer to the patient and sometimes at the patient bedside. The testing is usually performed by clinical staff, such as physicians or nurses, who are not laboratory trained. This document was developed by the POCT Interest group of the Canadian Society of Clinical Chemists (CSCC) as practical guidance for quality assurance practices related to POCT performed in hospital and outside hospital environments. The aspects of quality assurance addressed in this document include: (1) device selection, (2) initial device verification, (3) ongoing device verification, (4) ongoing quality assurance including reagent and quality control (QC) lot changes, and (5) quality management including operator and document management.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Pruebas en el Punto de Atención/normas , Garantía de la Calidad de Atención de Salud/métodos , Canadá , Humanos , Guías de Práctica Clínica como Asunto/normas , Control de Calidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA