Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 654
Filtrar
1.
JACC Cardiovasc Interv ; 17(18): 2141-2153, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39243262

RESUMEN

BACKGROUND: Patients with mitral regurgitation (MR) and morphologic presence of relevant mitral annular calcification (MAC) represent a challenging phenotypic subset with limited treatment options. OBJECTIVES: The aim of this study was to assess the feasibility of transcatheter mitral valve replacement (TMVR) using dedicated devices for the treatment of MAC patients. METHODS: Consecutive patients with symptomatic MR receiving TMVR and with available computed tomography data from the CHOICE-MI (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) multicenter registry were stratified by the presence of none or mild mitral annular calcification (MACnone/mild) vs moderate or severe mitral annular calcification (MACmod/sev). RESULTS: Among 279 eligible patients (median age = 76.0 years [Q1-Q3: 71.0-81.0 years], EuroSCORE II = 6.2% [Q1-Q3: 3.9%-12.1%]), 222 (79.6%) presented with MACnone/mild and 57 (20.4%) with MACmod/sev. Patients with MACmod/sev had a higher prevalence of extracardiac arteriopathy (P = 0.011) and primary MR (P < 0.001). Although the technical success rate and the extent of MR elimination did not differ, TMVR treatment in MACmod/sev patients was associated with higher rates of postprocedural bleeding complications (P = 0.02) and renal failure (P < 0.001). Functional improvement at the 1- and 2-year follow-up did not differ between groups. At the 2-year follow-up, there were no differences between patients with MACmod/sev and MACnone/mild regarding all-cause mortality (38.5% vs 37.7%; P = 0.76), cardiovascular mortality (21.3% vs 24.9%; P = 0.97), and all-cause mortality or heart failure hospitalization (52.4% vs 46.7%; P = 0.28) CONCLUSIONS: TMVR in patients with MACmod/sev is associated with higher rates of postprocedural complications but similar rates of survival, MR resolution, and functional improvement compared to MACnone/mild. Further studies are necessary to define the role of dedicated TMVR devices in this population. (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency Registry [CHOICE-MI]; NCT04688190).


Asunto(s)
Calcinosis , Cateterismo Cardíaco , Estudios de Factibilidad , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Humanos , Anciano , Masculino , Femenino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Anciano de 80 o más Años , Factores de Tiempo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Calcinosis/mortalidad , Calcinosis/fisiopatología , Calcinosis/terapia , Factores de Riesgo , Índice de Severidad de la Enfermedad , Europa (Continente)
2.
N Engl J Med ; 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39216093

RESUMEN

BACKGROUND: Current treatment recommendations for patients with heart failure and secondary mitral regurgitation include transcatheter edge-to-edge repair and mitral-valve surgery. Data from randomized trials comparing these therapies are lacking in this patient population. METHODS: In this noninferiority trial conducted in Germany, patients with heart failure and secondary mitral regurgitation who continued to have symptoms despite guideline-directed medical therapy were randomly assigned, in a 1:1 ratio, to undergo either transcatheter edge-to-edge repair (intervention group) or surgical mitral-valve repair or replacement (surgery group). The primary efficacy end point was a composite of death, hospitalization for heart failure, mitral-valve reintervention, implantation of an assist device, or stroke within 1 year after the procedure. The primary safety end point was a composite of major adverse events within 30 days after the procedure. RESULTS: A total of 210 patients underwent randomization. The mean (±SD) age of the patients was 70.5±7.9 years, 39.9% were women, and the mean left ventricular ejection fraction was 43.0±11.7%. Within 1 year, at least one of the components of the primary efficacy end point occurred in 16 of the 96 patients with available data (16.7%) in the intervention group and in 20 of the 89 with available data (22.5%) in the surgery group (estimated mean difference, -6 percentage points; 95% confidence interval [CI], -17 to 6; P<0.001 for noninferiority). A primary safety end-point event occurred in 15 of the 101 patients with available data (14.9%) in the intervention group and in 51 of the 93 patients with available data (54.8%) in the surgery group (estimated mean difference, -40 percentage points; 95% CI, -51 to -27; P<0.001). CONCLUSIONS: Among patients with heart failure and secondary mitral regurgitation, transcatheter edge-to-edge repair was noninferior to mitral-valve surgery with respect to a composite of death, rehospitalization for heart failure, stroke, reintervention, or implantation of an assist device in the left ventricle at 1 year. (Funded by Abbott Vascular; MATTERHORN ClinicalTrials.gov number, NCT02371512.).

3.
J Clin Med ; 13(15)2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39124586

RESUMEN

Background: Infectious endocarditis (IE) remains a critical condition despite all the medical advances in recent decades. Reliable pathogen identification is indispensable for precise therapy. The aim of this study was to evaluate the diagnostic and therapeutic benefit of additional polymerase chain reaction (PCR) in comparison with microbiological culture alone based on intraoperative tissue sampling for patients operated on due to IE. Methods: A total of 224 patients diagnosed with acute or subacute IE were analyzed. Intraoperatively resected infectious tissue was analyzed using both PCR and microbiological culture. Subsequently, the results of the detection of bacteria obtained based on intraoperative measurements from tissue via culture and PCR were compared with preoperative blood culture results. Furthermore, we evaluated the therapeutic impact of the culture and/or PCR results obtained from cardiac tissue. Results: The 224 patients were 63 ± 17 years old, and 64 (29%) were female. In total, 149 (67%) suffered from aortic valve endocarditis, 45 (45%) had mitral valve endocarditis, and 39 (18%) were afflicted with double-valve endocarditis. Prosthetic valve endocarditis was present in 70 (31%) patients. Pathogens were detected in 70% of the cases analyzed via PCR using cardiac valve tissue and in 25% of those analyzed via a culture of cardiac valve tissue; this figure was only 64% for preoperative blood culture. Overall, a pathogen was identified in 197 patients (88%), leading to antibiotic therapy. Targeted antibiotic therapy, based on the PCR results, was carried out in 37 cases and was conducted based on a culture from cardiac valve tissue in three cases. Finally, in 12% of patients, the causative pathogen remained unclear. Conclusions: For patients suffering endocarditis, PCR analysis is indispensable and superior to preoperative blood culture and intraoperative culture in detecting bacteria. Based on PCR testing, antibiotic therapy can be individually adjusted. The high precision of pathogen identification may lead to a significant reduction in IE-associated morbidity and mortality.

5.
J Cardiothorac Surg ; 19(1): 369, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38918755

RESUMEN

BACKGROUND: Anomalous left coronary artery originating from the pulmonary artery (ALCAPA), is a unique congenital anomaly, comprising only 0.24-0.46% of all congenital cardiac anomalies. Late presentations, ranging from asymptomatic cases to sudden cardiac arrest, are exceptionally rare. This unique case highlights the complexity of managing ALCAPA in adulthood and underscores the necessity of a comprehensive surgical approach addressing both coronary and valvular issues. PRESENTATION: A 34-year-old female patient, who had been diagnosed with ALPACA in her early childhood, suffered sudden cardiac arrest at work, followed by out-of-hospital resuscitation. The patient had been followed-up regularly until adolescence, however, she had refused surgery. In the diagnostic work-up following successful resuscitation severe mitral valve regurgitation was additionally revealed. Subsequently, the patient underwent surgery, involving coronary artery bypass grafting (CABG), using bilateral internal mammary arteries, and mitral valve repair, with an excellent postsurgical result. At 16-month follow-up, the patient was asymptomatic and quality of life had significantly improved. CONCLUSION: This rare case initially presented as silent myocardial ischemia, resulting in reduced left ventricular function and secondary mitral incompetence. Surgical treatment of ALCAPA in adults poses greater challenges and a higher risk than in children. CABG procedure offers an excellent prognostic therapeutic strategy, since this procedure is a routine in adult cardiac surgery.


Asunto(s)
Síndrome de Bland White Garland , Reanimación Cardiopulmonar , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Adulto , Femenino , Síndrome de Bland White Garland/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Reanimación Cardiopulmonar/métodos , Válvula Mitral/cirugía , Puente de Arteria Coronaria/métodos , Revascularización Miocárdica/métodos
6.
Gigascience ; 132024 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-38573186

RESUMEN

BACKGROUND: Cardiovascular research heavily relies on mouse (Mus musculus) models to study disease mechanisms and to test novel biomarkers and medications. Yet, applying these results to patients remains a major challenge and often results in noneffective drugs. Therefore, it is an open challenge of translational science to develop models with high similarities and predictive value. This requires a comparison of disease models in mice with diseased tissue derived from humans. RESULTS: To compare the transcriptional signatures at single-cell resolution, we implemented an integration pipeline called OrthoIntegrate, which uniquely assigns orthologs and therewith merges single-cell RNA sequencing (scRNA-seq) RNA of different species. The pipeline has been designed to be as easy to use and is fully integrable in the standard Seurat workflow.We applied OrthoIntegrate on scRNA-seq from cardiac tissue of heart failure patients with reduced ejection fraction (HFrEF) and scRNA-seq from the mice after chronic infarction, which is a commonly used mouse model to mimic HFrEF. We discovered shared and distinct regulatory pathways between human HFrEF patients and the corresponding mouse model. Overall, 54% of genes were commonly regulated, including major changes in cardiomyocyte energy metabolism. However, several regulatory pathways (e.g., angiogenesis) were specifically regulated in humans. CONCLUSIONS: The demonstration of unique pathways occurring in humans indicates limitations on the comparability between mice models and human HFrEF and shows that results from the mice model should be validated carefully. OrthoIntegrate is publicly accessible (https://github.com/MarianoRuzJurado/OrthoIntegrate) and can be used to integrate other large datasets to provide a general comparison of models with patient data.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Animales , Ratones , Insuficiencia Cardíaca/genética , Transcriptoma , Volumen Sistólico , Metabolismo Energético , ARN
7.
Antioxidants (Basel) ; 13(4)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38671948

RESUMEN

Endothelin-1 is a key regulator of vascular tone and blood pressure in health and disease. We have recently found that ET-1 production in human microvascular endothelial cells (HMECs) can be promoted by angiotensin II (Ang II) through a novel mechanism involving octamer-binding transcription factor-1 (Oct-1), NADPH oxidase-2 (NOX2), and superoxide anions. As the formation of bioactive ET-1 also depends on endothelin-converting enzyme-1 (ECE-1), we investigated the transcriptional regulation of the ECE1 gene. We found that exposure of HMECs to Ang II resulted in a concentration- and time-dependent increase in ECE1 mRNA expression. Pharmacological inhibition of ECE-1 reduced Ang II-stimulated ET-1 release to baseline values. The effect of Ang II on ECE1 mRNA expression was associated with Oct-1 binding to the ECE1 promoter, resulting in its increased activity. Consequently, the Ang II-stimulated increase in ECE1 mRNA expression could be prevented by siRNA-mediated Oct-1 inhibition. It could also be abolished by silencing the NOX2 gene and neutralizing superoxide anions with superoxide dismutase. In mice fed a high-fat diet, cardiac expression of Ece1 mRNA increased in wild-type mice but not in Nox2-deficient animals. It can be concluded that Ang II engages Oct-1, NOX2, and superoxide anions to stimulate ECE1 expression in the endothelium.

8.
J Cardiovasc Dev Dis ; 11(4)2024 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-38667730

RESUMEN

BACKGROUND: Minimally invasive aortic valve replacement (AVR) via upper ministernotomy (MiniAVR) is a standard alternative to full sternotomy access. Minimally invasive cardiac surgery has been proven to provide a number of benefits to patients. The aim of this study was to compare the short- and long-term outcomes after MiniAVR versus conventional AVR via full sternotomy (FS) using a biological prosthesis in an elderly higher-risk population. METHODS: Between January 2006 and July 2009, 918 consecutive patients received AVR ± additional procedures with different prostheses at our center. Amongst them, 441 received isolated AVR using a biological prosthesis (median age of 74.5; range: 52-93 years; 50% females) and formed the study population (EuroSCORE II: 3.62 ± 5.5, range: 0.7-42). In total, 137 (31.1%) of the operations were carried out through FS, and 304 (68.9%) were carried out via MiniAVR. Follow-up was complete in 96% of the cases (median of 7.6 years, 6610 patient-years). Propensity score matching (PSM) resulted in two groups of 68 patients with very similar baseline profiles. The primary endpoints were long-term survival, freedom from reoperation, and endocarditis, and the secondary endpoints were early major adverse cardiac and cerebrovascular events (MACCEs). RESULTS: FS led to shorter cardio-pulmonary bypass and aortic cross-clamp durations: 90 (47-194) vs. 100 (46-246) min (p = 0.039) and 57 (33-156) vs. 69 (32-118) min (p = 0.006), respectively. Perioperative stroke occurred in three patients (4.4%; FS) vs. one patient (1.5%; MiniAVR) (p = 0.506). The 30-day mortality was similar in both groups (2.9%, p = 1.000). Survival at 1, 5, and 10 years was 94.1 ± 3% (FS and MiniAVR), 80.3 ± 5% vs. 75.7 ± 5%, and 45.3 ± 6% vs. 43.8 ± 6%, respectively (p = 0.767). There were two (2.9%) reoperations in each group and two thrombo-embolic events (2.9%) vs. one (1.5%) thrombo-embolic event in the MiniAVR and FS groups, respectively (p = 0.596). CONCLUSIONS: In comparison to FS, MiniAVR provided similar short- and long-term outcomes in a higher-risk elderly population receiving biological prostheses. In particular, long-term survival, freedom from reoperation, and the incidence of endocarditis were comparable. These results clearly advocate for the routine use of MiniAVR as a standard procedure for AVR, even in a high-risk population.

9.
N Engl J Med ; 390(17): 1572-1583, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38588025

RESUMEN

BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Estimación de Kaplan-Meier , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Factores de Riesgo , Alemania
10.
Clin Res Cardiol ; 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38436739

RESUMEN

BACKGROUND: In patients not suitable for transfemoral transcatheter aortic valve implantation (TAVI), several access strategies can be chosen. AIM: To evaluate the use and patient outcomes of transaxillary (TAx), transapical (TA), and transaortic (TAo) as alternative access for TAVI in Germany; to further evaluate surgical cutdown vs. percutaneous TAx access. METHODS: All patients entered the German Aortic Valve Registry (GARY) between 2011 and 2019 who underwent non-transfemoral TAVI were included in this analysis. Patients with TA, TAo, or TAx TAVI were compared using a weighted propensity score model. Furthermore, a subgroup analysis was performed for TAx regarding the percutaneous or surgical cutdown approach. RESULTS: Overall, 9686 patients received a non-transfemoral access. A total of 8918 patients (92.1%) underwent TA, 398 (4.1%) TAo, and 370 (3.8%) TAx approaches. Within the TAx subgroup, 141 patients (38.1%) received subclavian cutdown, while 200 (54.1%) underwent a percutaneous approach. The TA patients had a significantly lower 30-day survival than TAx patients (TA 90.92% vs. TAx 95.59%, p = 0.006; TAo 92.22% vs. TAx 95.59%, p = 0.102). Comparing percutaneous and cutdown TAx approaches, no significant differences were seen. However, more vascular complications occurred (TA 1.8%, TAo 2.4%, TAx 12.2%; p < .001), and the hospital length of stay was shorter (TA 12.9 days, TAo 14.1 days, TAx 12 days; p < .001) after TAx access. CONCLUSION: It may be reasonable to consider TAx access first in patients not suitable for TF-TAVI, because the 30-day survival was higher compared with TA access and the 1-year survival was higher compared with TAo access. It remains important for the heart teams to offer alternative access modalities for patients not amenable to the standard TF-TAVI approaches.

11.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506737

RESUMEN

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Catéteres , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvulas Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
12.
Open Heart ; 11(1)2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38388188

RESUMEN

INTRODUCTION: Risk stratification based on Euroscore II (ESII) is used in some centres to assist decisions to perform transcatheter aortic valve implant (TAVI) procedures. ESII is a generic, non-TAVI-specific metric, and its performance fades for mortality at follow-up longer than 30 days. We investigated if a TAVI-specific predictive model could achieve improved predictive preinterventional accuracy of 1-year mortality compared with ESII. PATIENTS AND METHODS: In this prospective pilot study, 284 participants with severe symptomatic aortic valve stenosis who underwent TAVI were enrolled. Standard clinical metrics (American Society of Anesthesiology (ASA), New York Heart Association and ESII) and patient-reported outcome measures (EuroQol-5 Dimension-Visual Analogue Scale, Kansas City Cardiomyopathy Questionnaire and Clinical Frailty Scale (CFS)) were assessed 1 day before TAVI. Using these data, we tested predictive models (logistic regression and decision tree algorithm (DTA)) with 1-year mortality as the dependent variable. RESULTS: Logistic regression yielded the best prediction, with ASA and CFS as the strongest predictors of 1-year mortality. Our logistic regression model score showed significantly better prediction accuracy than ESII (area under the curve=0.659 vs 0.800; p=0.002). By translating our results to a DTA, cut-off score values regarding 1-year mortality risk emerged for low, intermediate and high risk. Treatment costs and length of stay (LoS) significantly increased in high-risk patients. CONCLUSIONS AND SIGNIFICANCE: A novel TAVI-specific model predicts 1-year mortality, LoS and costs after TAVI using simple, established, transparent and inexpensive metrics before implantation. Based on this preliminary evidence, TAVI team members and patients can make informed decisions based on a few key metrics. Validation of this score in larger patient cohorts is needed.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Tiempo de Internación , Proyectos Piloto , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Aprendizaje Automático
14.
J Microsc ; 293(3): 160-168, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38234217

RESUMEN

We calculate a universal shift in work function of 59.4 meV per decade of dopant concentration change that applies to all doped semiconductors and from this use Monte Carlo simulations to simulate the resulting change in secondary electron yield for doped GaAs. We then compare experimental images of doped GaAs layers from scanning electron microscopy and conductive atomic force microscopy. Kelvin probe force microscopy allows to directly measure and map local work function changes, but values measured are often smaller, typically only around half, of what theory predicts for perfectly clean surfaces.

15.
J Microsc ; 293(3): 135-137, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38282251
16.
Clin Res Cardiol ; 113(1): 75-85, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37462856

RESUMEN

BACKGROUND: Various second-generation transcatheter heart valve (THV) prostheses with high clinical efficacy and safety are available, but there is limited large-scale data available comparing their hemodynamic performance and clinical implications. OBJECTIVE: To compare the hemodynamic performance and short-term clinical outcome of four second-generation THV prostheses. METHODS: 24,124 patients out of the German Aortic Valve Registry who underwent transfemoral transcatheter aortic valve implantation (TAVI) (Evolut™ R n = 7028, Acurate neo™ n = 2922, Portico n = 878 and Sapien 3 n = 13,296) were included in this analysis. Propensity-score weighted analysis was performed to control for differences in age, left ventricular function, STS score and sex. Primary endpoint was survival at one-year, secondary endpoints were 30 days survival, pre-discharge transvalvular gradients, paravalvular leakage and peri-procedural complications. RESULTS: Thirty-day and one-year survival were not significantly different between the four patient groups. Transvalvular gradients in Evolut™ R and Acurate neo™ were significantly lower as compared to Portico and Sapien 3 at hospital discharge. This difference exists across all annulus sizes. Paravalvular leakage ≥ II occurred significantly less often in the Sapien 3 group (1.2%, p < 0.0001). Rate of severe procedural complications was low and comparable in all groups. Permanent pacemaker implantation rate at one year was lowest in the ACUARATE neo group (13.0%) and highest in the Evolut™ R group (21.9%). CONCLUSION: Albeit comparable short-term clinical outcomes there are certain differences regarding hemodynamic performance and permanent pacemaker implantation rate between currently available THV prostheses which should be considered for individual prosthesis selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros
17.
Ann Thorac Surg ; 117(3): 517-525, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37625612

RESUMEN

BACKGROUND: Aortic valve (AV) repair is an evolving surgical strategy in the treatment of nonelderly adults with aortic regurgitation. We aimed to determine the 1-year outcome after AV repair vs surgical AV replacement (sAVR) using real-world data from the German Aortic Valve Registry. METHODS: A total of 8076 aortic regurgitation patients (mean age, 59.1 ± 15.0 years; 76% men; mean The Society of Thoracic Surgeons score, 1.3 ± 1.1), who underwent AV surgical procedures between 2011 and 2015, were identified from German Aortic Valve Registry. The AV was repaired in 2327 patients (29%), and the remaining 5749 patients (71%) underwent sAVR. A weighted propensity score model, including the variables of age, sex, and The Society of Thoracic Surgeons score, was used to correct for baseline differences between AV repair and sAVR cohorts. The primary end point was 1-year survival after AV repair vs sAVR. Secondary end points were freedom from cardiac events and AV reinterventions. RESULTS: Survival at 1 year was 97.7% (95% CI, 97.0%-98.5%) in the AV repair cohort vs 96.4% (95% CI, 95.9%-96.9%) in the propensity score-weighted sAVR cohort (log-rank P < .001). Cox regression revealed a significant advantage of AV repair vs sAVR (hazard ratio, 0.68; 95% CI, 0.51-0.90; P < .0001) on 1-year survival, which was independent of age. Cardiac event-free survival at 1 year was 85.7% (95% CI, 483.8%-87.7%) in the AV repair group vs 81.7% (95% CI, 80.7%-82.9%) in the sAVR group (log-rank P < .001). AV reintervention was required in 38 AV repair patients (1.6%) compared with 1.6% in the sAVR cohort (P = .59). CONCLUSIONS: AV repair surgery, whenever intraoperatively feasible, is associated with a significantly better 1-year survival and 1-year cardiac event-free survival compared with sAVR.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Femenino , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Sistema de Registros
18.
Artículo en Inglés | MEDLINE | ID: mdl-38092063

RESUMEN

OBJECTIVE: Spinal cord injury (SCI) with subsequent paraplegia and/or stroke after arch repair with frozen elephant trunk (FET) remain the most devastating complications. In this study, we aim to examine the impact of different cerebral perfusion strategies on the neurological outcome comparing bilateral antegrade cerebral perfusion (bACP) and trilateral antegrade cerebral perfusion (tACP). METHODS: Between 2009 and 2021, 88 patients underwent total arch replacement using a hybrid prosthesis in FET technique for acute (40.4%) and chronic (59.6%) aortic pathologies. After excluding 14 patients who underwent FET with unilateral ACP the remaining 74 patients were divided into two groups. Propensity score matching was performed based on pre- and perioperative patient characteristics resulting in 22 patients in each group. The primary endpoint was a combination of major cerebral event and SCI. Secondary end point was all-cause mortality. RESULTS: Major cerebral events occurred in 9% of the patients in bACP versus 13.6% in tACP group (p = 0.63). No postoperative SCI was observed in patients with bACP and only one patient suffered SCI with tACP (p = 0.31). There was no significant difference in 30-day mortality between the two groups (22.7% in bACP vs. 13.6% in tACP; p = 0.43). CONCLUSION: In patients undergoing total aortic arch repair using FET technique, both perfusion strategies (bilateral and trilateral ACP) are safe and effective. The rates of neurological complications as well as mortalities are acceptably low in both groups. Further studies with larger patient cohorts are warranted.

19.
J Microsc ; 293(3): 169-176, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38112123

RESUMEN

Gallium ion (Ga+ ) beam damage induced indium (In) precipitation in indium gallium arsenide (InGaAs)/indium aluminium arsenide (InAlAs) multiple quantum wells and its corresponding evolution under electron beam irradiation was investigated by valence electron energy loss spectroscopy (VEELS) and high-angle annular dark-field imaging (HAADF) in scanning transmission electron microscopy (STEM). Compared with argon ion milling for sample preparation, the heavier projectiles of Ga+ ions pose a risk to trigger In formation in the form of tiny metallic In clusters. These are shown to be sensitive to electron irradiation and can increase in number and size under the electron beam, deteriorating the structure. Our finding reveals the potential risk of formation of In clusters during focused ion beam (FIB) preparation of InGaAs/InAlAs quantum well samples and their subsequent growth under STEM-HAADF imaging, where initially invisible In clusters of a few atoms can move and swell during electron beam exposure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA