Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 800
Filtrar
1.
JACC Cardiovasc Interv ; 17(18): 2141-2153, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39243262

RESUMEN

BACKGROUND: Patients with mitral regurgitation (MR) and morphologic presence of relevant mitral annular calcification (MAC) represent a challenging phenotypic subset with limited treatment options. OBJECTIVES: The aim of this study was to assess the feasibility of transcatheter mitral valve replacement (TMVR) using dedicated devices for the treatment of MAC patients. METHODS: Consecutive patients with symptomatic MR receiving TMVR and with available computed tomography data from the CHOICE-MI (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) multicenter registry were stratified by the presence of none or mild mitral annular calcification (MACnone/mild) vs moderate or severe mitral annular calcification (MACmod/sev). RESULTS: Among 279 eligible patients (median age = 76.0 years [Q1-Q3: 71.0-81.0 years], EuroSCORE II = 6.2% [Q1-Q3: 3.9%-12.1%]), 222 (79.6%) presented with MACnone/mild and 57 (20.4%) with MACmod/sev. Patients with MACmod/sev had a higher prevalence of extracardiac arteriopathy (P = 0.011) and primary MR (P < 0.001). Although the technical success rate and the extent of MR elimination did not differ, TMVR treatment in MACmod/sev patients was associated with higher rates of postprocedural bleeding complications (P = 0.02) and renal failure (P < 0.001). Functional improvement at the 1- and 2-year follow-up did not differ between groups. At the 2-year follow-up, there were no differences between patients with MACmod/sev and MACnone/mild regarding all-cause mortality (38.5% vs 37.7%; P = 0.76), cardiovascular mortality (21.3% vs 24.9%; P = 0.97), and all-cause mortality or heart failure hospitalization (52.4% vs 46.7%; P = 0.28) CONCLUSIONS: TMVR in patients with MACmod/sev is associated with higher rates of postprocedural complications but similar rates of survival, MR resolution, and functional improvement compared to MACnone/mild. Further studies are necessary to define the role of dedicated TMVR devices in this population. (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency Registry [CHOICE-MI]; NCT04688190).


Asunto(s)
Calcinosis , Cateterismo Cardíaco , Estudios de Factibilidad , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Humanos , Anciano , Masculino , Femenino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Anciano de 80 o más Años , Factores de Tiempo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Calcinosis/mortalidad , Calcinosis/fisiopatología , Calcinosis/terapia , Factores de Riesgo , Índice de Severidad de la Enfermedad , Europa (Continente)
2.
JACC Cardiovasc Interv ; 17(18): 2093-2112, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39322362
4.
JACC Cardiovasc Interv ; 17(18): 2170-2179, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39322365

RESUMEN

BACKGROUND: Transcatheter tricuspid valve intervention (TTVI) has been increasingly adopted in recent years for the treatment of patients with tricuspid regurgitation (TR). However, no dedicated risk stratification has been established for patients undergoing TTVI. OBJECTIVES: The aim of the present study was to propose a dedicated risk score for patients affected by severe TR undergoing TTVI. METHODS: The score was derived from the TRIVALVE (International Multisite Transcatheter Tricuspid Valve Therapies Registry; NCT03416166) registry, according to data availability. A stepwise model approach was used on predictor variables to develop a scoring system for predicting 12-month mortality or rehospitalization using multivariable logistic regression. Internal discrimination, calibration, and validation were assessed using receiver-operating characteristic curve analysis and bootstrapping with 1,000 resamples. RESULTS: A total of 483 patients were included in the study, with an overall 12-month mortality or rehospitalization rate of 19% (n = 94). The final risk score, ranging from 0 to 4.5, included the following 5 parameters (adjusted for age and gender): 1) atrial fibrillation at baseline; 2) glomerular filtration rate <30 mL/min; 3) elevated gamma-glutamyl transferase/bilirubin levels; 4) signs of right heart failure; and 5) left ventricular ejection fraction <50%. The bias-corrected area under the receiver-operating characteristic curve was 68% (95% CI: 62%-75%). A cutoff value of 2.5 demonstrated sensitivity of 65.4% and specificity of 60.5% for the outcome. CONCLUSIONS: The present study proposes a dedicated risk score for patients undergoing TTVI, providing an additional and simple tool for heart teams to select the best therapy for patients affected by severe TR.


Asunto(s)
Cateterismo Cardíaco , Técnicas de Apoyo para la Decisión , Implantación de Prótesis de Válvulas Cardíacas , Readmisión del Paciente , Valor Predictivo de las Pruebas , Sistema de Registros , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Medición de Riesgo , Masculino , Femenino , Factores de Riesgo , Anciano , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Reproducibilidad de los Resultados , Toma de Decisiones Clínicas , Persona de Mediana Edad
7.
Artículo en Inglés | MEDLINE | ID: mdl-39189600

RESUMEN

AIMS: Transcatheter tricuspid valve interventions (TTVI) are increasingly used to treat patients with significant tricuspid regurgitation (TR). The evolution of concurrent mitral regurgitation (MR) severity after TTVI is currently unknown and may be pivotal for clinical decision-making. The aim of this study was to assess the evolution of MR after TTVI and to identify predictors of MR worsening and improvement. METHODS AND RESULTS: This analysis is a substudy of the Trivalve Registry, an international registry designed to collect data on TTVI. This substudy included all patients with echocardiographic data on MR evolution and excluded those with a concomitant tricuspid and mitral transcatheter valve intervention or with a history of mitral valve intervention. The co-primary outcomes were MR improvement and worsening at two timepoints: pre-discharge and 2-month follow-up. This analysis included 359 patients with severe TR, mostly(80%) treated with tricuspid transcatheter edge-to-edge repair(T-TEER). MR improvement was found in 106(29.5%) and 99(34%) patients, while MR worsening in 34(9.5%) and 33(11%) patients at pre-discharge and 2-month follow-up, respectively. Annuloplasty and heterotopic replacement were associated with MR worsening. Independent predictors of MR improvement were: atrial fibrillation, T-TEER, acute procedural success, TR reduction, LVEDD>60 mm and beta-blocker therapy. Patients with moderate-to-severe/severe MR following TTVI showed significantly higher death rates. CONCLUSION: MR degree variation is common after TTVI, with most cases showing improvement. Clinical and procedural characteristics may predict the MR evolution, in particular procedural success and T-TEER play key roles in MR outcomes. TTVI may be beneficial even in the presence of functional MR.

8.
J Soc Cardiovasc Angiogr Interv ; 3(3Part B): 101293, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-39131219

RESUMEN

Background: Coronary artery disease (CAD) in patients with severe aortic stenosis (AS) is common and may be associated with worse outcomes. Computed tomography coronary angiography (CTCA) and fractional flow reserve derived from computed tomography (FFRCT) are tools for comprehensive coronary assessment. The utility and safety of CTCA and FFRCT in the work-up for transcatheter aortic valve replacement (TAVR) is not established, especially in an evolving landscape that involves younger TAVR patients. The FUTURE-AS Registry will assess the utility and safety of cardiac-optimized CTCA and FFRCT to evaluate CAD and guide referral for downstream invasive coronary angiography (ICA) in patients with severe AS being considered for TAVR. Methods: FUTURE-AS is an international, prospective, multicenter registry of patients with severe AS referred for TAVR being assessed for CAD with CTCA and FFRCT. The primary end point is the per-patient sensitivity and negative predictive value of CTCA and FFRCT for identifying anatomical and physiologically significant CAD compared to ICA and invasive FFR. The safety end point is the incidence of symptomatic hypotension or bradycardia requiring intervention following the administration of nitroglycerin or ß-blocker medications. Feasibility end points include the incidence of noninterpretable CTCA scans and CTCA scans not adequate for FFR analysis. Other utility end points include specificity, positive predictive value, and accuracy of CTCA and FFRCT. Lastly, the potential of a CTCA and FFRCT guided strategy to defer pre-TAVR ICA will be assessed. Conclusions: FUTURE-AS will characterize the utility, safety, and feasibility of CTCA and FFRCT for coronary assessment pre-TAVR.

10.
JACC Cardiovasc Interv ; 17(11): 1340-1351, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866457

RESUMEN

BACKGROUND: The etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms. OBJECTIVES: The authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology. METHODS: TAV explants were obtained from the EXPLANT THV registry and clinical institutions. Hydrodynamic assessment was performed using a heart valve pulse duplicator system under physiological conditions. Micro-computed tomography, high-resolution photography, high speed video, and hematoxylin and eosin staining were used to evaluate the morphological appearance, leaflet kinematics, and calcium burden of TAVs. RESULTS: A total of 14 explants were evaluated: 10 self-expanding CoreValve/Evolut TAVs (Medtronic), 3 balloon-expandable SAPIEN 3 TAVs (Edwards Lifesciences), and 1 mechanically expandable Lotus TAV (Boston Scientific). The median patient age at explantation was 73.0 years (Q1-Q3: 64.5-80.0 years), with a time to explantation of 4 years 1 month (1 year 5 months to 4 years 11 months). Six TAV explants were found to have leaflet calcification (162.4 mm3; 58.8-603.0 mm3), and 8 had no calcification detectable by micro-computed tomography and histology. All samples had impaired leaflet kinematics. There was no significant difference in the hydrodynamic mean gradient between calcified (47.2 mm Hg; 26.6-74.1 mm Hg) and noncalcified (27.6 mm Hg; 15.2-36.7 mm Hg; P = 0.28) TAVs. Leaflet calcification had a weak but nonsignificant association with the hydrodynamic mean gradient (r = 0.42; P = 0.14). CONCLUSIONS: TAV function can be severely impacted by noncalcific and calcific mechanisms of tissue degeneration. Importantly, functional stenosis can occur in TAVs in the absence of obvious and significant calcification.


Asunto(s)
Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Hidrodinámica , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Microtomografía por Rayos X , Humanos , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Calcinosis/cirugía , Femenino , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Persona de Mediana Edad , Factores de Tiempo , Remoción de Dispositivos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Fenómenos Biomecánicos , Ensayo de Materiales , Grabación en Video
11.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866455

RESUMEN

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estimulación Cardíaca Artificial , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Factores de Riesgo , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/mortalidad , Estados Unidos/epidemiología
12.
Arch. cardiol. Méx ; 94(2): 219-239, Apr.-Jun. 2024. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1556919

RESUMEN

resumen está disponible en el texto completo


Abstract This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.

13.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726720

RESUMEN

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Asunto(s)
Consenso , Hemorragia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Hemorragia/etiología , Medición de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía
14.
JACC Cardiovasc Interv ; 17(12): 1485-1495, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38752971

RESUMEN

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/mortalidad , Masculino , Femenino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Anciano , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Factores de Tiempo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad , Medición de Riesgo , Sistema de Registros
15.
JAMA Cardiol ; 9(7): 611-618, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38748410

RESUMEN

Importance: Osteosarcopenia is an emerging geriatric syndrome characterized by age-related deterioration in muscle and bone. Despite the established relevance of frailty and sarcopenia among older adults undergoing transcatheter aortic valve replacement (TAVR), osteosarcopenia has yet to be investigated in this setting. Objective: To determine the association between osteosarcopenia and adverse outcomes following TAVR. Design, Setting, and Participants: This is a post hoc analysis of the Frailty in Aortic Valve Replacement (FRAILTY-AVR) prospective multicenter cohort study and McGill extension that enrolled patients aged 70 years or older undergoing TAVR from 2012 through 2022. FRAILTY-AVR was conducted at 14 centers in Canada, the United States, and France between 2012 and 2016, and patients at the McGill University-affiliated center in Montreal, Québec, Canada, were enrolled on an ongoing basis up to 2022. Exposure: Osteosarcopenia as measured on computed tomography (CT) scans prior to TAVR. Main Outcomes and Measures: Clinically indicated CT scans acquired prior to TAVR were analyzed to quantify psoas muscle area (PMA) and vertebral bone density (VBD). Osteosarcopenia was defined as a combination of low PMA and low VBD according to published cutoffs. The primary outcome was 1-year all-cause mortality. Secondary outcomes were 30-day mortality, hospital length of stay, disposition, and worsening disability. Multivariable logistic regression was used to adjust for potential confounders. Results: Of the 605 patients (271 [45%] female) in this study, 437 (72%) were octogenarian; the mean (SD) age was 82.6 (6.2) years. Mean (SD) PMA was 22.1 (4.5) cm2 in men and 15.4 (3.5) cm2 in women. Mean (SD) VBD was 104.8 (35.5) Hounsfield units (HU) in men and 98.8 (34.1) HU in women. Ninety-one patients (15%) met the criteria for osteosarcopenia and had higher rates of frailty, fractures, and malnutrition at baseline. One-year mortality was highest in patients with osteosarcopenia (29 patients [32%]) followed by those with low PMA alone (18 patients [14%]), low VBD alone (16 patients [11%]), and normal bone and muscle status (21 patients [9%]) (P < .001). Osteosarcopenia, but not low VBD or PMA alone, was independently associated with 1-year mortality (odds ratio [OR], 3.18; 95% CI, 1.54-6.57) and 1-year worsening disability (OR, 2.11; 95% CI, 1.19-3.74). The association persisted in sensitivity analyses adjusting for the Essential Frailty Toolset, Clinical Frailty Scale, and geriatric conditions such as malnutrition and disability. Conclusions and Relevance: The findings suggest that osteosarcopenia detected using clinical CT scans could be used to identify frail patients with a 3-fold increase in 1-year mortality following TAVR. This opportunistic method for osteosarcopenia assessment could be used to improve risk prediction, support decision-making, and trigger rehabilitation interventions in older adults.


Asunto(s)
Estenosis de la Válvula Aórtica , Sarcopenia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Sarcopenia/epidemiología , Sarcopenia/complicaciones , Anciano de 80 o más Años , Anciano , Estudios Prospectivos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Fragilidad/complicaciones , Tomografía Computarizada por Rayos X , Densidad Ósea , Músculos Psoas/diagnóstico por imagen , Canadá/epidemiología , Francia/epidemiología , Anciano Frágil , Factores de Riesgo
16.
Eur Heart J Cardiovasc Imaging ; 25(9): 1276-1286, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-38693866

RESUMEN

AIMS: Evaluation of left and right ventricular (RV) longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and RV longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30 days and 1 year after AVR. METHODS AND RESULTS: Left ventricular (LV) longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER 2A surgical AVR (SAVR) arm (n = 985) and from the PARTNER 2 SAPIEN 3 registry (n = 719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline was associated with increased risk of the composite of death, hospitalization, and stroke at 5 years [adjusted hazard ratios (HRs) for LV LS < 15%: 1.24, 95% confidence interval (CI) 1.05-1.45, P = 0.001; TAPSE < 14 mm: 1.44, 95% CI 1.21-1.73, P < 0.001; RV-PA coupling < 0.55 mm/mmHg: 1.32, 95% CI 1.07-1.63, P = 0.011]. Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5 years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95% CI 1.08-1.68, P = 0.009) but not with TAVR (HR: 1.12, 95% CI 0.88-1.42). Lower RV-PA coupling at 30 days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30 days were associated with inferior clinical outcomes at 5 years. In patients with LVEF < 50%, TAVR was associated with superior 5-year outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Sistema de Registros , Humanos , Masculino , Femenino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Medición de Riesgo , Sístole , Anciano de 80 o más Años , Resultado del Tratamiento , Volumen Sistólico/fisiología , Ecocardiografía , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología
17.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599688

RESUMEN

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Estudios Multicéntricos como Asunto , Sistema de Registros
18.
Mol Ther Oncol ; 32(1): 200775, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38596311

RESUMEN

Chimeric antigen receptor (CAR) T cell therapies targeting B cell-restricted antigens CD19, CD20, or CD22 can produce potent clinical responses for some B cell malignancies, but relapse remains common. Camelid single-domain antibodies (sdAbs or nanobodies) are smaller, simpler, and easier to recombine than single-chain variable fragments (scFvs) used in most CARs, but fewer sdAb-CARs have been reported. Thus, we sought to identify a therapeutically active sdAb-CAR targeting human CD22. Immunization of an adult Llama glama with CD22 protein, sdAb-cDNA library construction, and phage panning yielded >20 sdAbs with diverse epitope and binding properties. Expressing CD22-sdAb-CAR in Jurkat cells drove varying CD22-specific reactivity not correlated with antibody affinity. Changing CD28- to CD8-transmembrane design increased CAR persistence and expression in vitro. CD22-sdAb-CAR candidates showed similar CD22-dependent CAR-T expansion in vitro, although only membrane-proximal epitope targeting CD22-sdAb-CARs activated direct cytolytic killing and extended survival in a lymphoma xenograft model. Based on enhanced survival in blinded xenograft studies, a lead CD22sdCAR-T was selected, achieving comparable complete responses to a benchmark short linker m971-scFv CAR-T in high-dose experiments. Finally, immunohistochemistry and flow cytometry confirm tissue and cellular-level specificity of the lead CD22-sdAb. This presents a complete report on preclinical development of a novel CD22sdCAR therapeutic.

19.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479968

RESUMEN

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología
20.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479966

RESUMEN

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Accidente Cerebrovascular Isquémico/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA