Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
1.
Clin Res Cardiol ; 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39256220

RESUMEN

BACKGROUND AND OBJECTIVE: Transcatheter aortic valve replacement (TAVR) is an established treatment option for patients with symptomatic severe aortic stenosis across all stages of surgical risk. Rapid pacing during the procedure and the risk for the occurrence of conduction disturbances after TAVR requires the pre-interventional insertion of a temporary pacemaker (TP). However, this approach poses risks, including the risk of infection. For this reason, the following study aimed to investigate microbial growth on temporary pacemaker leads and its association with outcome post-TAVR and to identify associated pathogens and related risk factors. METHODS: A prospective study was conducted including 344 patients undergoing TAVR at the Heart Centre Bonn. Of these, 97 patients did not require TP leads as they already had permanent pacemakers; this group was considered as comparison group. The TP leads of the remaining 247 patients were removed, sonicated, and cultured to investigate bacterial growth over a period of 14 days. Finally, we compared patients without microbial growth (n = 184) and patients with microbial growth (n = 63). The primary endpoint of the study was 30-day all-cause mortality, secondary endpoints were periprocedural infections, the length of the postprocedural hospital stay, 30-day major vascular complications and the 30-day stroke rate. RESULTS: The majority of cases (74.5%) showed no bacterial growth. In the remaining cases (25.5%), diverse microorganisms were identified, mostly non-pathogenic bacteria. The statistical analysis revealed no significant differences between groups according to microbial growth in terms of 30-day mortality (p = 0.446), postprocedural hospital stay (p = 0.401), periprocedural infections (p = 0.434), 30-day major vascular complications (p = 1.0), and 30-day stroke rate (p = 1.0). Notably, the timing of sheath insertion was significantly associated with microbial growth; sheath placement more than 2 days prior to the procedure was associated with a significantly higher risk of microbial growth (OR: 2.1; 95% CI 1.1-4.3) (p = 0.030). CONCLUSIONS: The presence of temporary leads does not significantly impact clinical outcomes, irrespective of bacterial growth on the lead. However, the timing and duration of sheath placement plays a crucial role in contamination incidence. Thus, temporary leads/sheaths should be placed shortly before the procedure and removed promptly to reduce the risk of contamination/infection.

2.
JACC Cardiovasc Interv ; 17(18): 2113-2122, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39243264

RESUMEN

BACKGROUND: Tricuspid regurgitation (TR) is a common valve disease that has a significant impact on patients' quality of life. OBJECTIVES: This study sought to report the final 3-year outcomes of tricuspid transcatheter edge-to-edge repair (T-TEER) with the TriClip (Abbott) implant from the TRILUMINATE (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR) study for the treatment of severe symptomatic TR. METHODS: The TRILUMINATE study (N = 98 subjects) is an international, prospective, single-arm, multicenter study to investigate the safety and performance of T-TEER with the TriClip implant in patients with symptomatic moderate or greater TR. Echocardiographic assessments were performed at a core laboratory. RESULTS: At 3 years, TR was reduced to moderate or less in 79% of subjects, and a reduction of at least 1 grade was achieved in 92% of subjects. TR reduction achieved at 1 year was sustained through 3 years. Subjects also experienced an improvement in heart failure symptoms assessed by NYHA functional class and quality of life assessed by the Kansas City Cardiomyopathy Questionnaire at 3 years compared to baseline. The site-reported heart failure hospitalization rate decreased from 0.56 events/patient-year 1 year before device implantation to 0.14 events/patient-year 3 years after device implantation, representing a reduction of 75% (P < 0.0001). CONCLUSIONS: In the longest follow-up to date of any T-TEER therapy, the TRILUMINATE study demonstrated that the TriClip procedure is both safe and effective, with sustained benefits at 3 years in subjects with symptomatic moderate or greater TR. (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR [TRILUMINATE]; NCT03227757).


Asunto(s)
Cateterismo Cardíaco , Calidad de Vida , Recuperación de la Función , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Femenino , Estudios Prospectivos , Resultado del Tratamiento , Masculino , Anciano , Factores de Tiempo , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Persona de Mediana Edad , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/diagnóstico por imagen , Diseño de Prótesis , Anciano de 80 o más Años , Estados Unidos , Europa (Continente) , Estado Funcional
3.
Psychol Bull ; 150(8): 1011-1019, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39172391

RESUMEN

Our meta-analysis on gender differences in sex drive found a stronger sex drive in men compared to women (Frankenbach et al., 2022). Conley and Yang (2024) criticized how we interpreted the findings and provided suggestions regarding the origins of these gender differences, an undertaking that we had refrained from doing in our original work. We concur with several important points made by Conley and Yang (2024): (a) women's sexual experiences are generally more negative than men's, which could partly explain why men report more sex drive; (b) lack of statistical moderation by some sociocultural variables does not imply that the sex drives of men and women are generally unaffected by the social environment; and (c) gender differences in sexuality are likely smaller than they are often portrayed in research, and that the practical impact of this difference is largely unknown. Still, we reject other assertions made by Conley and Yang (2024): (a) we did not frame our findings in support of the view that gender differences in sex drive are determined by biology, (b) we did not conflate response bias with sociocultural biases more broadly, and (c) we did not fail to incorporate and consider gendered cultural messages about sexuality in our methods and discussion. We make several suggestions about future research on these matters. (PsycInfo Database Record (c) 2024 APA, all rights reserved).


Asunto(s)
Conducta Sexual , Humanos , Femenino , Masculino , Conducta Sexual/psicología , Conducta Sexual/fisiología , Factores Sexuales , Caracteres Sexuales , Libido/fisiología
4.
Rheumatol Int ; 44(10): 1975-1986, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39167172

RESUMEN

OBJECTIVES: This cross-sectional study aimed to determine the prevalence, manifestation, and risk factors of pulmonary involvement in newly diagnosed, untreated rheumatoid arthritis (RA) and psoriatic arthritis (PsA) patients, and to evaluate the efficacy of various diagnostic tools in screening for pulmonary involvement. METHODS: Untreated, newly diagnosed patients with RA and PsA underwent an extensive multimodal diagnostic approach including clinical and laboratory assessment, pulmonary function tests, and chest radiography. RESULTS: We recruited 50 arthritis patients (26 RA, 24 PsA) and 26 control subjects. Respiratory symptoms were found in 36.0 % of arthritis patients and 11.5 % of controls (p = 0.031). Pathologically reduced breathing width (< 3.0 cm) was significantly more common in arthritis patients (64.0 %) than in controls (23.1 %) (p < 0.001). Pulmonary function test results did not differ significantly between groups. Chest radiography revealed pulmonary involvement in 37.0 % of arthritis patients, higher in RA (50.0 %) than in PsA (22.7 %). Notably, only 35.3 % of arthritis patients with radiographic pulmonary involvement were symptomatic, with 64.7 % being asymptomatic. Radiographic pulmonary involvement was associated with advanced age (p = 0.002) and increased rheumatoid factor levels (p = 0.024). CONCLUSION: Our research underscores the significant prevalence of largely asymptomatic pulmonary involvement in newly diagnosed RA and PsA patients. These findings highlight the importance of an early, multidisciplinary screening approach, particularly for high-risk individuals. Further large-scale studies are needed to develop comprehensive screening protocols to improve early detection and treatment of pulmonary involvement in arthritis.


Asunto(s)
Artritis Psoriásica , Artritis Reumatoide , Pruebas de Función Respiratoria , Humanos , Artritis Psoriásica/epidemiología , Artritis Psoriásica/diagnóstico por imagen , Artritis Reumatoide/epidemiología , Artritis Reumatoide/complicaciones , Artritis Reumatoide/diagnóstico por imagen , Artritis Reumatoide/diagnóstico , Masculino , Persona de Mediana Edad , Femenino , Estudios Transversales , Adulto , Prevalencia , Factores de Riesgo , Anciano , Enfermedades Pulmonares/diagnóstico por imagen , Enfermedades Pulmonares/epidemiología , Enfermedades Pulmonares/etiología , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Estudios de Casos y Controles
5.
J Clin Med ; 13(14)2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39064227

RESUMEN

Background/Objectives: Previous trials reported comparable results with PASCAL and earlier MitraClip generations. Limited comparative data exist for more contemporary MitraClip generations, particularly the large MitraClip XT(R/W). We aimed to evaluate acute and 30-day outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) with one of the large devices, either PASCAL P10 or MitraClip XT(R/W) (3rd/4th generation). Methods: A total of 309 PASCAL-treated patients were matched by propensity score to 253 MitraClip-treated patients, resulting in 200 adequately balanced pairs. Procedural, clinical, and echocardiographic outcomes were collected for up to 30 days, including subgroup analysis for mitral regurgitation (MR) etiologies. Results: PASCAL and MitraClip patients were comparable regarding age (80 vs. 79 years), sex (female: 45.5% vs. 50.5%), and MR etiology (degenerative MR: n = 94, functional MR [FMR]: n = 96, mixed MR: n = 10 in each group). Technical success rates were comparable (96.5% vs. 96.0%; p > 0.999). At discharge, the mean gradient was higher (3.3 mmHg vs. 3.0 mmHg; p = 0.038), and the residual mitral valve orifice area was smaller in MitraClip patients (3.0 cm2 vs. 2.3 cm2; p < 0.001). At discharge, the reduction to MR ≤ 2+ was comparable (92.4% vs. 87.8%; p = 0.132). However, reduction to MR ≤ 1+ was more frequently observed in PASCAL patients (67.7% vs. 56.6%; p = 0.029), driven by the FMR subgroup (74.0% vs. 60.0%; p = 0.046). No difference was observed in 30-day mortality (p = 0.204) or reduction in NYHA-FC to ≤II (p > 0.999). Conclusions: Both M-TEER devices exhibited high and comparable rates of technical success and MR reduction to ≤2+. PASCAL may be advantageous in achieving MR reduction to ≤1+ in patients with FMR.

6.
Rheumatol Int ; 44(6): 1025-1034, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38713410

RESUMEN

OBJECTIVES: This cross-sectional study aimed to determine the prevalence and risk factors for sleep-related breathing disorders (SRBD) in newly diagnosed, untreated rheumatoid arthritis (RA) and psoriatic arthritis (PsA) patients, and to develop a screening algorithm for early detection. METHODS: We evaluated newly diagnosed RA or PsA patients using the Epworth Sleepiness Scale (ESS) questionnaire, cardiorespiratory polygraphy (RPG), and clinical and laboratory assessments. Sleep apnea syndrome (SAS) was diagnosed based on pathological RPG findings excessive daytime sleepiness, defined as ESS score above 10. RESULTS: The study included 39 patients (22 RA, 17 PsA) and 23 controls. In RPG, SRBD was identified in 38.5% of arthritis patients compared to 39.1% of controls (p = 1.00), with male gender (p = .004) and age (p < .001) identified as risk factors. Excessive daytime sleepiness was noted in 36.4% of RA patients, 17.6% of PsA patients, and 21.7% of controls. Of the 24 patients diagnosed with SRBD, 41.6% met the criteria for SAS. SAS prevalence was 31.8% among RA patients, 0% in PsA patients, and 13% in controls. A significant association was observed between excessive daytime sleepiness and SRBD (p = .036). CONCLUSION: Our findings reveal a high prevalence of SRBD in newly diagnosed, untreated RA and PsA patients in ESS and RPG, with excessive daytime sleepiness being a reliable predictor of SRBD. Patients with RA exhibited a higher predisposition to SAS. We therefore suggest incorporating ESS and RPG as screening tools in RA or PsA for early detection and management of SRBD.


Asunto(s)
Artritis Psoriásica , Artritis Reumatoide , Síndromes de la Apnea del Sueño , Humanos , Masculino , Estudios Transversales , Artritis Psoriásica/diagnóstico , Artritis Psoriásica/epidemiología , Femenino , Persona de Mediana Edad , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/epidemiología , Artritis Reumatoide/diagnóstico , Artritis Reumatoide/epidemiología , Artritis Reumatoide/complicaciones , Adulto , Prevalencia , Factores de Riesgo , Anciano , Polisomnografía , Estudios de Casos y Controles , Encuestas y Cuestionarios
7.
JACC Cardiovasc Interv ; 17(12): 1485-1495, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38752971

RESUMEN

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/mortalidad , Masculino , Femenino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Anciano , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Factores de Tiempo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad , Medición de Riesgo , Sistema de Registros
8.
Circ Cardiovasc Interv ; 17(6): e013156, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38629314

RESUMEN

BACKGROUND: We assessed the safety profile of tricuspid transcatheter edge-to-edge repair (TEER) in patients with right ventricular (RV) dysfunction. METHODS: We identified patients undergoing TEER to treat tricuspid regurgitation from June 2015 to October 2021 and assessed tricuspid annular plane systolic excursion (TAPSE) and RV fractional area change (RVFAC). RV dysfunction was defined as TAPSE <17 mm and RVFAC <35%. The primary end point was 30-day mortality after TEER. We also investigated the change in the RV function in the early phase and clinical outcomes at 2 years. RESULTS: The study participants (n=262) were at high surgical risk (EuroSCORE II, 6.2% [interquartile range, 4.0%-10.3%]). Among them, 44 patients met the criteria of RV dysfunction. Thirty-day mortality was 3.2% in patients with normal RV function and 2.3% in patients with RV dysfunction (P=0.99). Tricuspid regurgitation reduction to ≤2+ was consistently achieved irrespective of RV dysfunction (76.5% versus 70.5%; P=0.44). TAPSE and RVFAC declined after TEER in patients with normal RV function (TAPSE, 19.0±4.7 to 17.9±4.5 mm; P=0.001; RVFAC, 46.2%±8.1% to 40.3%±9.7%; P<0.001). In contrast, those parameters were unchanged or tended to increase in patients with RV dysfunction (TAPSE, 13.2±2.3 to 15.3±4.7 mm; P=0.011; RVFAC, 29.6%±4.1% to 31.6%±8.3%; P=0.14). Two years after TEER, compared with patients with normal RV function, patients with RV dysfunction had significantly higher mortality (27.0% versus 56.3%; P<0.001). CONCLUSIONS: TEER was safe and feasible to treat tricuspid regurgitation in patients with RV dysfunction. The decline in the RV function was observed in patients with normal RV function but not in patients with RV dysfunction.


Asunto(s)
Cateterismo Cardíaco , Recuperación de la Función , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Disfunción Ventricular Derecha , Función Ventricular Derecha , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Masculino , Femenino , Disfunción Ventricular Derecha/fisiopatología , Disfunción Ventricular Derecha/mortalidad , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Resultado del Tratamiento , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Factores de Tiempo , Factores de Riesgo , Persona de Mediana Edad , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Anciano de 80 o más Años , Medición de Riesgo
9.
J Clin Med ; 13(5)2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38592259

RESUMEN

Background: Minimally invasive mitral valve surgery (MIC-MVS) has been established as preferred treatment of mitral regurgitation (MR), but mitral transcatheter edge-to-edge valve repair (M-TEER) is routinely performed in patients at high surgical risk and is increasingly performed in intermediate risk patients. Methods: From 2010 to 2021, we performed 723 M-TEER and 123 isolated MIC-MVS procedures. We applied a sensitivity analysis by matching age, left ventricular ejection fraction (LVEF), EuroSCORE II and etiology of MR. Results: Baseline characteristics showed significant differences in the overall cohort (p < 0.01): age 78.3 years vs. 61.5 years, EuroSCORE II 5.5% vs. 1.3% and LVEF 48.4% vs. 60.4% in M-TEER vs. MIC-MVS patients. Grade of MR at discharge was moderate/severe in 24.5% (171/697) in M-TEER vs. 6.5% (8/123) in MIC-MVS (p < 0.01). One-year survival was 91.5% (552/723) in M-TEER vs. 97.6% (95/123) in MIC-MVS (p = 0.04). A matching with 49 pairs (n = 98) showed comparable survival during follow-up, but a numerically higher mean mitral valve gradient of 4.1 mmHg (95% CI: 3.6-4.6) vs. 3.4 mmHg (95% CI: 3.0-3.8) in M-TEER (p = 0.04). Conclusions: Patients undergoing M-TEER had lower one-year survival than MIC-MVS, but differences disappeared after matching. Reduction in MR was less effective in M-TEER patients and postprocedural mitral valve gradients were higher.

11.
Viruses ; 16(3)2024 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-38543705

RESUMEN

As the COVID-19 pandemic revealed, rapid development of vaccines and therapeutic antibodies are crucial to guarantee a quick return to the status quo of society. In early 2020, we deployed our droplet microfluidic single-cell-based platform DROPZYLLA® for the generation of cognate antibody repertoires of convalescent COVID-19 donors. Discovery of SARS-CoV-2-specific antibodies was performed upon display of antibodies on the surface of HEK293T cells by antigen-specific sorting using binding to the SARS-CoV-2 spike and absence of binding to huACE2 as the sort criteria. This efficiently yielded antibodies within 3-6 weeks, of which up to 100% were neutralizing. One of these, MTX-COVAB, displaying low picomolar neutralization IC50 of SARS-CoV-2 and with a neutralization potency on par with the Regeneron antibodies, was selected for GMP manufacturing and clinical development in June 2020. MTX-COVAB showed strong efficacy in vivo and neutralized all identified clinically relevant variants of SARS-CoV-2 at the time of its selection. MTX-COVAB completed GMP manufacturing by the end of 2020, but clinical development was stopped when the Omicron variant emerged, a variant that proved to be detrimental to all monoclonal antibodies already approved. The present study describes the capabilities of the DROPZYLLA® platform to identify antibodies of high virus-neutralizing capacity rapidly and directly.


Asunto(s)
COVID-19 , Pandemias , Humanos , Células HEK293 , SARS-CoV-2/genética , Anticuerpos Antivirales , Anticuerpos Neutralizantes , Glicoproteína de la Espiga del Coronavirus
12.
Eur J Heart Fail ; 26(4): 1015-1024, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38454641

RESUMEN

AIMS: Prognostic impact of post-procedural changes in right ventricular (RV) function after tricuspid transcatheter edge-to-edge repair (T-TEER) is still unclear. We investigated association of RV function and its post-procedural changes with clinical outcomes in patients undergoing T-TEER. METHODS AND RESULTS: We retrospectively analysed 204 patients who underwent T-TEER and echocardiographic follow-up at 3 months after T-TEER. RV function was assessed by RV fractional area change (RVFAC), and RV dysfunction was defined as RVFAC <35%. Patients with an increase in RVFAC from baseline to the follow-up were considered as RV responders. Patients were divided into four groups according to baseline RVFAC and the RV responder. The primary outcome was a composite of mortality and hospitalization due to heart failure within 1 year. Forty-five of 204 patients (22.1%) had RVFAC <35% at baseline, and 71 (34.8%) were RV responders. The association between the RV responder and the composite outcome had a significant interaction with RVFAC at baseline. Among patients with baseline RVFAC <35%, RV responders had a lower risk of the composite outcome than RV non-responders, while this association was not significant in those with baseline RVFAC ≥35%. Among patients with baseline RVFAC <35%, a smaller RV diameter and a greater reduction of tricuspid regurgitation were predictors for the RV responder. CONCLUSION: Post-procedural increase in RVFAC after T-TEER is associated with improved outcomes in patients with RV dysfunction. The factors related to the increase in RVFAC may support patient selection for T-TEER in patients with RV dysfunction.


Asunto(s)
Cateterismo Cardíaco , Ecocardiografía , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Función Ventricular Derecha , Humanos , Masculino , Femenino , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Estudios Retrospectivos , Función Ventricular Derecha/fisiología , Anciano , Cateterismo Cardíaco/métodos , Ecocardiografía/métodos , Disfunción Ventricular Derecha/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Resultado del Tratamiento , Estudios de Seguimiento , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Pronóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Persona de Mediana Edad
13.
J Thorac Imaging ; 39(4): 224-231, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38389116

RESUMEN

PURPOSE: Inflammatory changes in epicardial (EAT) and pericardial adipose tissue (PAT) are associated with increased overall cardiovascular risk. Using routine, preinterventional cardiac CT data, we examined the predictive value of quantity and quality of EAT and PAT for outcome after transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS: Cardiac CT data of 1197 patients who underwent TAVR at the in-house heart center between 2011 and 2020 were retrospectively analyzed. The amount and density of EAT and PAT were quantified from single-slice CT images at the level of the aortic valve. Using established risk scores and known independent risk factors, a clinical benchmark model (BMI, Chronic kidney disease stage, EuroSCORE 2, STS Prom, year of intervention) for outcome prediction (2-year mortality) after TAVR was established. Subsequently, we tested whether the additional inclusion of area and density values of EAT and PAT in the clinical benchmark model improved prediction. For this purpose, the cohort was divided into a training (n=798) and a test cohort (n=399). RESULTS: Within the 2-year follow-up, 264 patients died. In the training cohort, particularly the addition of EAT density to the clinical benchmark model showed a significant association with outcome (hazard ratio 1.04, 95% CI: 1.01-1.07; P =0.013). In the test cohort, the outcome prediction of the clinical benchmark model was also significantly improved with the inclusion of EAT density (c-statistic: 0.589 vs. 0.628; P =0.026). CONCLUSIONS: EAT density as a surrogate marker of EAT inflammation was associated with 2-year mortality after TAVR and may improve outcome prediction independent of established risk parameters.


Asunto(s)
Tejido Adiposo , Estenosis de la Válvula Aórtica , Inflamación , Pericardio , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Masculino , Tejido Adiposo/diagnóstico por imagen , Pericardio/diagnóstico por imagen , Estudios Retrospectivos , Anciano de 80 o más Años , Tomografía Computarizada por Rayos X/métodos , Inflamación/diagnóstico por imagen , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Valor Predictivo de las Pruebas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo , Tejido Adiposo Epicárdico
14.
PLoS One ; 19(2): e0286423, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38319942

RESUMEN

BACKGROUND: Interstitial lung disease (ILD) comprises a wide variety of pulmonary parenchymal disorders within which progressive fibrosing ILD (PF-ILD) constitutes a phenotypic subset. By use of speckle tracking-based strain analysis we aimed to evaluate the degree of left ventricular (LV) dysfunction in progressive vs. non-progressive fibrosing ILD (non-PF-ILD). METHODS: A total of 99 ILD patients (mean age 63.7 ± 13.5 years, 37.4% female), composed of 50 PF-ILD and 49 non-PF-ILD patients, and 33 controls were prospectively enrolled and underwent conventional and speckle tracking echocardiography. Additional laboratory and pulmonary function testing, as well as six-minute walk test were performed. RESULTS: As compared to the non-PF-ILD cohort, PF-ILD patients exhibited a significantly impaired forced vital capacity (2.4 ± 1.0l vs. 3.1 ± 0.9l, p = 0.002), diffusion capacity for carbon monoxide (DLCO, 25.6 ± 16.3% predicted vs. 43.6 ± 16.67% predicted, p <0.001) and exercise capacity response as measured by the six-minute walk test distance (268.1 ± 178.2m vs. 432.6 ± 94.2m, p <0.001). Contrary to conventional echocardiographic LV parameters, both regional and global longitudinal LV strain measurements were significantly altered in ILD patients as compared to controls. No differences in LV strain were found between both patient groups. Significant correlations were observed between global longitudinal strain, on the one hand, and systemic inflammation markers, total lung capacity (TLC) and DLCO, on the other hand (high-sensitivity C-reactive protein: Pearson´s r = -0.30, p< 0.001; interleukin-6: Pearson´s r = -0.26, p = 0.007; TLC % predicted: Pearson´s r = 0.22, p = 0.02; DLCO % predicted: Pearson´s r = 0.21, p = 0.02). CONCLUSIONS: ILD is accompanied by LV dysfunction. LV functionality inversely correlates with the severity of the restrictive ventilatory defect and inflammation marker levels. These observations support the assumption of persistent low-grade systemic inflammation that may link systemic cardiovascular function to ILD status.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Disfunción Ventricular Izquierda , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Enfermedades Pulmonares Intersticiales/complicaciones , Capacidad Vital , Función Ventricular Izquierda , Pruebas de Función Respiratoria , Inflamación/complicaciones , Pulmón , Estudios Retrospectivos
15.
EuroIntervention ; 20(4): e250-e260, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38389471

RESUMEN

BACKGROUND: The prognostic benefits of transcatheter edge-to-edge repair (TEER) remain unclear in patients with atrial functional mitral regurgitation (AFMR). AIMS: We aimed to investigate the clinical outcomes of TEER for patients with AFMR. METHODS: We retrospectively classified functional mitral regurgitation (FMR) patients undergoing TEER into those with AFMR or ventricular FMR (VFMR). A residual MR ≤1+ at discharge was considered optimal mitral regurgitation (MR) reduction, and an elevated mean mitral valve pressure gradient (MPG) was defined as an MPG ≥5 mmHg at discharge. The primary outcome was a composite of all-cause mortality and hospitalisation due to heart failure within one year. RESULTS: Of 441 FMR patients, 125 patients were considered as having AFMR. Residual MR ≤1+ was associated with a lower risk of the composite outcome in both AFMR and VFMR patients, while an MPG ≥5 mmHg was associated with a higher risk of the composite outcome in patients with AFMR but not with VFMR. AFMR patients with residual MR ≤1+ and an MPG ≥5 mmHg, as well as those with residual MR >1+, had a higher incidence of the composite outcome than those with residual MR ≤1+ and an MPG <5 mmHg (50.7%, 41.8%, and 14.3%, respectively; p<0.001). This association was consistent after adjustment for clinical and echocardiographic characteristics. CONCLUSIONS: An MR reduction to ≤1+ following TEER was associated with a lower risk of clinical outcomes in patients with AFMR, while an MPG ≥5 mmHg was related to a higher risk of clinical outcomes. Optimal MR reduction by TEER may have potential benefits on the prognosis of patients with AFMR, although the prognostic benefit may be attenuated by an elevated MPG.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Atrios Cardíacos , Ventrículos Cardíacos
17.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-37624856

RESUMEN

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco
18.
Clin Res Cardiol ; 113(1): 156-167, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37792020

RESUMEN

BACKGROUND: Obesity and underweight represent classical risk factors for outcome in patients treated for cardiovascular disease. This study describes the impact of different body mass index (BMI) categories on 1-year clinical outcome in patients with tricuspid regurgitation (TR) undergoing transcatheter-edge-to-edge repair (TEER). METHODS: We analyzed 211 consecutive patients (age 78.3 ± 7.2 years, 55.5% female, median EuroSCORE II 9.6 ± 6.7) with tricuspid regurgitation undergoing TEER from June 2015 until May 2021. Patients were prospectively enrolled in our single center registry and were retrospectively analyzed. Patients were stratified according to body mass index (BMI) into 4 groups: BMI < 20 kg/m2 (underweight), BMI 20.0 to < 25.0 kg/m2 (normal weight), BMI 25.0 to > 30.0 kg/m2 (overweight) and BMI ≥ 30 kg/m2 (obese). RESULTS: Kaplan-Meier survival curves demonstrated inferior survival for underweight and obese patients, but comparable outcomes for normal and overweight patients (global log rank test, p < 0.01). Cardiovascular death was significantly higher in underweight patients compared to the other groups (24.1% vs. 7.0% vs. 6.3% vs. 6.4%; p < 0.01). Over all, there were comparable rates of bleeding, stroke and myocardial infarction. Multivariable Cox regression analysis (adjusted for age, gender, coronary artery disease, chronic obstructive pulmonary disease, tricuspid annular plane systolic excursion, left-ventricular ejection fraction) confirmed underweight (HR 3.88; 95% CI 1.64-7.66; p < 0.01) and obesity (HR 3.24; 95% CI 1.37-9.16; p < 0.01) as independent risk factors for 1-year all-cause mortality. CONCLUSIONS: Compared to normal weight and overweight patients, obesity and underweight patients undergoing TEER display significant higher 1-year all-cause mortality.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Índice de Masa Corporal , Sobrepeso , Volumen Sistólico , Estudios Retrospectivos , Delgadez , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Función Ventricular Izquierda , Obesidad
19.
Clin Res Cardiol ; 113(1): 177-186, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38010521

RESUMEN

BACKGROUND: Assessing right ventricular (RV) function is paramount for risk stratification, which remains challenging in patients with tricuspid regurgitation (TR). We assessed RV-pulmonary artery (PA) coupling and its predictability of outcomes after transcatheter tricuspid valve repair (TTVR). METHODS: Study participants comprised patients undergoing transcatheter tricuspid valve repair to treat symptomatic TR from June 2015 to July 2021. We calculated an RV-PA coupling ratio using a formula, which is dividing tricuspid annular plane systolic excursion (TAPSE) by echocardiographically estimated (ePASP) or invasively measured PASP (iPASP) at baseline. The primary outcome was all-cause mortality or heart failure rehospitalization within one year. RESULTS: The study participants (n = 206) were at high surgical risk (EuroSCORE II: 7.4 ± 4.8%). The primary outcome occurred in 57 patients within one year. The c-statistics for the outcome were 0.565 (95% CI 0.488-0.643) for TAPSE/ePASP and 0.695 (95% CI 0.631-0.759) for TAPSE/iPASP. The correlation between the ePASP and iPASP was attenuated in patients with massive/torrential TR compared to those with severe TR (interaction p = 0.01). In the multivariable Cox proportional model, TAPSE/iPASP was inversely associated with the risk of the primary outcome (per 0.1-point increase: adjusted-HR 0.67, 95% CI 0.56-0.82, p < 0.001), independent of baseline demographics. According to the TAPSE/iPASP quartiles (i.e., ≤ 0.316; 0.317-0.407; 0.408-0.526; ≥ 0.527), the event-free survival was 43.4%, 48.3%, 77.9%, and 85.4% at one year after TTVR. CONCLUSION: RV-PA coupling predicts one-year mortality and heart failure rehospitalization after TTVR in patients with TR. The predictability is improved if invasively-measured PA pressure is included.


Asunto(s)
Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Humanos , Válvula Tricúspide , Arteria Pulmonar , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Función Ventricular Derecha
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA