Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 193
Filtrar
1.
J Bone Joint Surg Am ; 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38870269

RESUMEN

BACKGROUND: Knee instability in midflexion may contribute to patient dissatisfaction following total knee arthroplasty (TKA). Midflexion instability involves abnormal motions and tissue loading in multiple planes. Therefore, we quantified and compared the tensions carried by the medial and lateral collateral ligaments (MCL and LCL) following posterior-stabilized (PS) TKA through knee flexion, and then compared these tensions with those carried by the native knee. Finally, we examined the relationships between collateral ligament tensions and anterior tibial translation (ATT). METHODS: Eight cadaveric knees (from 5 male and 3 female donors with a mean age of 62.6 years and standard deviation of 10.9 years) underwent PS TKA. Each specimen was mounted to a robotic manipulator and flexed to 90°. ATT was quantified by applying 30 N of anterior force to the tibia. Tensions carried by the collateral ligaments were determined via serial sectioning. Robotic testing was also conducted on a cohort of 15 healthy native cadaveric knees (from 9 male and 6 female donors with a mean age of 36 years and standard deviation of 11 years). Relationships between collateral ligament tensions during passive flexion and ATT were assessed via linear and nonlinear regressions. RESULTS: MCL tensions were greater following PS TKA than in the native knee at 15° and 30° of passive flexion, by a median of ≥27 N (p = 0.002), while the LCL tensions did not differ. Median tensions following PS TKA were greater in the MCL than in the LCL at 15°, 30°, and 90° of flexion, by ≥4 N (p ≤ 0.02). Median tensions in the MCL of the native knee were small (≤11 N) and did not exceed those in the LCL (p ≥ 0.25). A logarithmic relationship was identified between MCL tension and ATT following TKA. CONCLUSIONS: MCL tensions were greater following PS TKA with this typical nonconforming PS implant than in the native knee. Anterior laxity at 30° of flexion was highly sensitive to MCL tension during passive flexion following PS TKA but not in the native knee. CLINICAL RELEVANCE: Surgeons face competing objectives when performing PS TKA: they can either impart supraphysiological MCL tension to reduce anterior-posterior laxity or maintain native MCL tensions that lead to heightened anterior-posterior laxity, as shown in this study.

2.
Hip Int ; : 11207000241254353, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38916080

RESUMEN

BACKGROUND: The growing adoption of robotic-assistance during total hip arthroplasty (THA) has provided novel means through which a patient's anatomy and dynamic spinopelvic relationship can be incorporated into surgical planning. However, the impact of enhanced technologies on intraoperative decision-making and changes to component positioning has not yet been described. METHODS: A multicentre, prospective study included 105 patients (52% women) patients who underwent robotic-assisted THA with the integration of software that incorporates a patient's pelvic tilt (PT) and virtual range-of-motion (VROM) for impingement modeling. The primary outcome of the study was the percentage of patients who underwent changes to the preoperative plan for cup position after incorporating the data from the software. RESULTS: Utilising the intraoperative VROM information, the preoperative plan for cup position was changed from the default (40° inclination and 20° anteversion) in 82/105 (78%) cases. When stratifying by spinopelvic mobility, 64% were considered normal (change ⩾ 10° and ⩽30°), 27% were stiff (change < 10°), and 9% were hypermobile (change > 30°). For all cohorts, the majority of cases (78%) deviated from the 40° inclination and 20° version target. When evaluating the proportion of cases within the Lewinnek and Callanan safe zones based on spinopelvic mobility, 19% of cases within the normal group were planned outside of both zones compared to 39% of stiff cases and 10% of hypermobile cases. CONCLUSIONS: Utilising the latest version of robotic-assisted THA software, the preoperative plan for cup position was changed in the vast majority (78%) of patients, causing substantial deviations from traditional, generic cup targets.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38738862

RESUMEN

PURPOSE: The purpose of this study was to examine the effects of intraoperative technology use on the rate of using polyethylene liners 15 mm or greater during primary total knee arthroplasty (TKA). METHODS: There were 103,295 implants from 16,386 primary unilateral TKAs performed on 14,253 patients at a single institution between 1 January 2018, and 30 June 2022, included in the current study. Robotic assistance and navigation guidance were used in 1274 (8%) and 8345 (51%) procedures, respectively. The remaining 6767 TKAs (41%) were performed manually. Polyethylene liners were manually identified and further subcategorised by implant thickness. Patients who underwent robotic-assisted TKA were younger (p < 0.001) and more likely to be male (p < 0.001) compared to patients who underwent navigation-guided or manual TKAs. RESULTS: Average polyethylene liner thickness was similar between groups (10.5 ± 1.5 mm for robotic-assisted TKAs, 10.9 ± 1.8 mm for navigation-guided TKAs and 10.8 ± 1.8 mm for manual TKAs). The proportions of polyethylene liners 15 mm or greater used were 4.9%, 3.8% and 1.9% for navigation-guided, manual and robotic-assisted procedures, respectively (p < 0.001). Multivariate regression analyses demonstrated that navigation-guided (odds ratio [OR]: 2.6, 95% confidence Interval [CI]: [1.75-4.07], p < 0.001) and manual (OR: 2.0, 95% CI: [1.34-3.20], p = 0.001) procedures were associated with an increased use of polyethylene liners 15 mm or greater. CONCLUSION: Robotic-assisted TKA was associated with a lower proportion of polyethylene liners 15 mm or greater used compared to navigation-guided and manual TKA. These findings suggest that robotic assistance can reduce human error via a more precise cutting system, limit over-resection of the tibia and flexion-extension gap mismatch and ultimately allow for more appropriately sized implants. LEVEL OF EVIDENCE: Level III, retrospective cohort study.

4.
J Arthroplasty ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38735554

RESUMEN

BACKGROUND: Interprosthetic femur fractures (IPFFs) are a rare, but devastating complication following total joint arthroplasty. There is limited evidence to help guide their management. The purpose of this study was to describe the features, treatment, and outcomes of surgically managed IPFFs. METHODS: We retrospectively identified 75 patients who had 76 IPFFs. The mean age at the time of IPFF was 75 years (range, 29 to 94), and 78% were women. The mean body mass index was 30 (range, 19 to 51), and the mean follow-up was 3 years (range, 0 to 14). There were 16 Vancouver B1 fractures, 28 Vancouver B2 fractures, 2 Vancouver B3 fractures, and 30 Vancouver C fractures. All B1 fractures underwent open reduction internal fixation (ORIF). All Vancouver B2 and B3 fractures underwent revision arthroplasty, including 1 proximal femur replacement and 1 total femur replacement. Vancouver C fractures were treated with ORIF (n = 20), distal femoral replacement (n = 9), and in 1 case, total femur replacement (n = 1). Kaplan-Meier survivorship was used to calculate 2-year survival free from all-cause reoperation and periprosthetic joint infection (PJI). RESULTS: The 2-year survivorship-free rate from reoperation was 71%. There were 18 reoperations following initial surgical management of the IPFF, including 9 for infection, 3 for refracture, 3 for nonunion, 2 for hardware failure, and 1 for instability. An initial IPFF involving a stemmed femoral total knee arthroplasty component was associated with increased risk for reoperation (P = .007) and PJI (P = .044). There was no difference in survivorship free of reoperation between IPFFs managed with ORIF or revision arthroplasty (P = .72). CONCLUSIONS: An IPFF is a devastating complication following total joint arthroplasty with high reoperation rates, most commonly secondary to PJI. Those IPFFs that occurred between 2 stemmed components were at the highest risk for reoperation.

5.
J Arthroplasty ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38599529

RESUMEN

BACKGROUND: Partial or total release of the posterior cruciate ligament (PCL) is often performed intraoperatively in cruciate-retaining total knee arthroplasty (CR-TKA) to alleviate excessive femoral rollback. However, the effect of the release of selected fibers of the PCL on femoral rollback in CR-TKA is not well understood. Therefore, we used a computational model to quantify the effect of selective PCL fiber releases on femoral rollback in CR-TKA. METHODS: Computational models of 9 cadaveric knees (age: 63 years, range 47 to 79) were virtually implanted with a CR-TKA. Passive flexion was simulated with the PCL retained and after serially releasing each individual fiber of the PCL, starting with the one located most anteriorly and laterally on the femoral notch and finishing with the one located most posteriorly on the medial femoral condyle. The experiment was repeated after releasing only the central PCL fiber. The femoral rollback of each condyle was defined as the anterior-posterior distance between tibiofemoral contact points at 0° and 90° of flexion. RESULTS: Release of the central PCL fiber in combination with the anterolateral (AL) fibers, reduced femoral rollback a median of 1.5 [0.8, 2.1] mm (P = .01) medially and by 2.0 [1.2, 2.5] mm (P = .04) laterally. Releasing the central fiber alone reduced the rollback by 0.7 [0.4, 1.1] mm (P < .01) medially and by 1.0 [0.5, 1.1] mm (P < .01) laterally, accounting for 47 and 50% of the reduction when released in combination with the AL fibers. CONCLUSIONS: Releasing the central fibers of the PCL had the largest impact on reducing femoral rollback, either alone or in combination with the release of the entire AL bundle. Thus, our findings provide clinical guidance regarding the regions of the PCL that surgeons should target to reduce femoral rollback in CR-TKA.

6.
J Arthroplasty ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38642850

RESUMEN

BACKGROUND: Identification of femoral component debonding in the work-up of painful total knee arthroplasty (TKA) often poses a diagnostic challenge. The purpose of this study was to compare the sensitivity and specificity of radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) for identifying femoral component loosening with debonding at the time of revision of a primary TKA with a recalled polyethylene insert. METHODS: Using an institutional database, we identified all cases of revision TKA performed for this specific implant recall following a primary TKA between 2014 and 2022. Patients who had a preoperative radiograph, CT, and MRI were included (n = 77). Sensitivity, specificity, and positive and negative likelihood ratio (LR) for predicting loosening were compared among the imaging modalities, using the intraoperative evidence of implant loosening as the gold standard. RESULTS: At the time of revision surgery, the femoral component was noted to have aseptic loosening with debonding in 46 of the 77 (60%) of the TKAs. There were no significant differences in demographics in the cohort with femoral debonding compared to those with well-fixed implants. The CT demonstrated a sensitivity of 28% and a specificity of 97%, while the MRI demonstrated a sensitivity of 37% and a specificity of 94% for detecting femoral loosening due to debonding. Both CT and MRI demonstrated poor negative LRs for femoral loosening (LR 0.7). CONCLUSIONS: In this series of revision TKAs for a specific recalled component, neither CT nor MRI accurately diagnosed femoral component debonding. For patients who have this implant, it is imperative to interrogate the implant-cement interface intraoperatively and prepare for full revision surgery as well as marked bone loss secondary to osteolysis.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38662001

RESUMEN

INTRODUCTION: Options for soft tissue coverage in revision total knee arthroplasty (rTKA) range from primary wound closure to complex muscle flap reconstructions. The purpose of this study was to investigate the institutional experience of wound coverage options for complex soft tissue defects in rTKA. MATERIALS AND METHODS: 77 patients undergoing rTKA with complex wound closure by a single plastic surgeon were retrospectively reviewed. The average follow-up was 30.1 months. In 18 (23.4%) patients, an intraoperative decision for primary closure was made. Fifty-nine patients (76.6%) received either a local fasciocutaneous (N = 18), a medial gastrocnemius (N = 37), a free latissimus dorsi (N = 3) or a lateral gastrocnemius flap (N = 1). Revision-free survival and complication rates were assessed and risk factors were analyzed with Cox-regression analysis. RESULTS: Medial gastrocnemius flaps had significant lower cumulative revision-free survival rates than local fasciocutaneous flaps (P = 0.021) and primary closures (P < 0.001) (42.5% vs. 71.5% vs. 100%,respectively). Comparing the most common complex closure procedures medial gastrocnemius flaps had the highest rate of prolonged wound healing (29.7%) and infection/reinfection (40.5%). Infection-associated flap procedures had significant lower cumulative revision-free survival rates (30.5%) than non-infection associated flap procedures (62.8%,P = 0.047). A history of more than two prior surgeries (HR = 6.11,P < 0.001) and an age ≥ 65 years (HR = 0.30,P = 0.018) significantly increased the risk of revision. CONCLUSIONS: The results of this study indicate that primary closure -if possible- should be preferred to early proactive muscle flap coverage. Even in the hands of an experienced plastic surgeon muscle flaps have high revision and complication rates. The study highlights the need to clarify flap indications and to investigate alternative approaches.

8.
Arthroplast Today ; 26: 101318, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38440289

RESUMEN

Background: Femoral neck anteversion has traditionally been measured by the angle between the distal femur posterior condylar axis (PCA) and a line drawn through the center of the femoral head and neck. While less common, the transepicondylar axis (TEA) has also been used to reference femoral neck anteversion. The purpose of this study was to compare femoral neck version of the PCA vs the TEA using computerized tomography (CT). Methods: A total of 1507 femoral CTs were included. Precise bony landmarks were established: lateral epicondyle, medial epicondyle, posteromedial condyle, posterolateral condyle, center of the femoral neck, and center of the femoral head. Femoral version was calculated between the head and neck axis and either the PCA or TEA. Differences between sex and ethnicity were evaluated. Results: The mean femoral anteversion was 12.7° ± 9.1° based on the PCA and 11.5° ± 7.9° based on the TEA (mean difference 1.2° ± 1.9°, P < .001). Males were less anteverted than females (9.8° ± 7.6° vs 13.5° ± 7.8°, P < .001). African Americans had less anteversion than other groups (8.1° ± 9.2° vs 11.5° ± 7.8°, P = .04), while Asians were more anteverted than other groups (12.1° ± 9.0° vs 11.2° ± 7.3°, P = .04). These values were referenced on the TEA. Conclusions: In this series of over 1500 femoral CT scans, the mean difference between anteversion measurements referencing the PCA and TEA was 1.2°. Native femoral version varied widely between gender and ethnic groups. Extreme femoral version, defined as <0° or >30°, was present in 11.8% of patients referencing the PCA.

9.
Anesth Analg ; 138(6): 1163-1172, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38190339

RESUMEN

BACKGROUND: Optimal analgesic protocols for total knee arthroplasty (TKA) patients remain controversial. Multimodal analgesia is advocated, often including peripheral nerve blocks and/or periarticular injections (PAIs). If 2 blocks (adductor canal block [ACB] plus infiltration between the popliteal artery and capsule of the knee [IPACK]) are used, also performing PAI may not be necessary. This noninferiority trial hypothesized that TKA patients with ACB + IPACK + saline PAI (sham infiltration) would have pain scores that were no worse than those of patients with ACB + IPACK + active PAI with local anesthetic. METHODS: A multimodal analgesic protocol of spinal anesthesia, ACB and IPACK blocks, intraoperative ketamine and ketorolac, postoperative ketorolac followed by meloxicam, acetaminophen, duloxetine, and oral opioids was used. Patients undergoing primary unilateral TKA were randomized to receive either active PAI or control PAI. The active PAI included a deep injection, performed before cementation, of bupivacaine 0.25% with epinephrine, 30 mL; morphine; methylprednisolone; cefazolin; with normal saline to bring total volume to 64 mL. A superficial injection of 20 mL bupivacaine, 0.25%, was administered before closure. Control injections were normal saline injected with the same injection technique and volumes. The primary outcome was numeric rating scale pain with ambulation on postoperative day 1. A noninferiority margin of 1.0 was used. RESULTS: Ninety-four patients were randomized. NRS pain with ambulation at POD1 in the ACB + IPACK + saline PAI group was not found to be noninferior to that of the ACB + IPACK + active PAI group (difference = 0.3, 95% confidence interval [CI], [-0.9 to 1.5], P = .120). Pain scores at rest did not differ significantly among groups. No significant difference was observed in opioid consumption between groups. Cumulative oral morphine equivalents through postoperative day 2 were 89 ± 40 mg (mean ± standard deviation), saline PAI, vs 73 ± 52, active PAI, P = .1. No significant differences were observed for worst pain, fraction of time in severe pain, pain interference, side-effects (nausea, drowsiness, itching, dizziness), quality of recovery, satisfaction, length of stay, chronic pain, and orthopedic outcomes. CONCLUSIONS: For TKA patients given a comprehensive analgesic protocol, use of saline PAI did not demonstrate noninferiority compared to active PAI. Neither the primary nor any secondary outcomes demonstrated superiority for active PAI, however. As we cannot claim either technique to be better or worse, there remains flexibility for use of either technique.


Asunto(s)
Anestésicos Locales , Artroplastia de Reemplazo de Rodilla , Bloqueo Nervioso , Dolor Postoperatorio , Arteria Poplítea , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Masculino , Femenino , Anciano , Dolor Postoperatorio/tratamiento farmacológico , Dolor Postoperatorio/prevención & control , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología , Persona de Mediana Edad , Bloqueo Nervioso/métodos , Arteria Poplítea/cirugía , Inyecciones Intraarticulares , Anestésicos Locales/administración & dosificación , Dimensión del Dolor , Resultado del Tratamiento , Método Doble Ciego , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Analgesia/métodos
10.
Hip Int ; 34(1): 15-20, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36891584

RESUMEN

INTRODUCTION: The relationship between implant type, dual mobility (DM) or fixed bearing (FB), and postoperative groin pain remains unexplored. We examined the incidence of groin pain in DM implants and compare this to a cohort of FB THA patients. METHODS: From 2006 to 2018, a single surgeon performed 875 DM THA and 856 FB THA procedures with 2.8-year and 3.1-year follow-up, respectively. Each patient received a questionnaire postoperatively and was asked if they had any groin pain (yes/no). Secondary measurements were implant characteristics such as head size, head offset, cup size, and cup-to-head ratio. Additional PROMs that were collected included: Veterans RAND 12 (VR-12), University of California Los Angeles (UCLA) activity score, Pain visual analogue scale (Pain VAS), and range of motion (ROM). RESULTS: The incidence of groin pain was 2.3% in the DM THA cohort and 6.3% in the FB THA group (p < 0.001). Also, low head offset (⩽0 mm) had a significant odds ratio (1.61) for groin pain in both cohorts. There was no significant difference in terms of revision rate between the cohorts (2.5% vs. 3.3%, p = 0.39) at the latest follow up. CONCLUSIONS: This study demonstrated a lower incidence of groin pain (2.3%) in patients with a DM bearing compared to a FB (6.3%) and a greater risk of groin pain with low head offset (<0 mm). As such, surgeons should try to recreate offset of the hip compared to the contralateral side to avoid groin pain.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Ingle/cirugía , Reoperación/efectos adversos , Diseño de Prótesis , Dolor Postoperatorio/epidemiología , Dolor Postoperatorio/etiología , Falla de Prótesis , Luxación de la Cadera/cirugía , Estudios Retrospectivos
11.
Arch Orthop Trauma Surg ; 143(11): 6927-6933, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37395854

RESUMEN

INTRODUCTION: Due to the increasing number of total hip arthroplasties (THA), the number and complexity of revision procedures are also on the rise. For complex cases such as periprosthetic joint infections with soft tissue compromise or for abductor muscle deficiencies, one of the treatment options is a gluteus maximus flap (GMF) that covers dead space and can help restore the failed abductor mechanism. The purpose of this study is to investigate the outcomes of a single-plastic surgeon's series of GMF procedures. MATERIALS AND METHODS: This retrospective review reports on 57 patients (mean follow-up 39.2 months) undergoing GMF transfers for abductor insufficiency on native hip (N = 16), for abductor insufficiency in aseptic revision THA (rTHA) (N = 16), for soft tissue defects in aseptic rTHA (N = 8) and for soft tissue defects in septic rTHA (N = 17) by a single plastic surgeon over a 10-year period. Revision-free survival and complication rates were assessed and risk factors were analyzed with Cox-regression analysis. RESULTS: The reoperation-free survival rate of GMF for abductor insufficiency in native hips was 100%. GMF procedures for soft tissue defects in septic rTHA had the lowest cumulative revision-free survival (34.3%) and highest reinfection rates (53.9%). More than three prior surgeries (HR = 2.9, p = 0.020), presence of infection (HR = 3.2, p = 0.010) and resistant organisms (HR = 3.1, p = 0.022) significantly increased the risk of revision. CONCLUSIONS: GMF is a viable option for addressing abductor insufficiency in native hip joints. However, high revision and complication rates are reported for GMF in septic rTHA. This study highlights the need to clarify the circumstances for which the flap reconstruction will be indicated.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Cirujanos , Humanos , Factor de Maduración de la Glia , Colgajos Quirúrgicos/cirugía , Articulación de la Cadera/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos
12.
Bone Jt Open ; 4(6): 432-441, 2023 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-37272302

RESUMEN

Aims: Mid-level constraint designs for total knee arthroplasty (TKA) are intended to reduce coronal plane laxity. Our aims were to compare kinematics and ligament forces of the Zimmer Biomet Persona posterior-stabilized (PS) and mid-level designs in the coronal, sagittal, and axial planes under loads simulating clinical exams of the knee in a cadaver model. Methods: We performed TKA on eight cadaveric knees and loaded them using a robotic manipulator. We tested both PS and mid-level designs under loads simulating clinical exams via applied varus and valgus moments, internal-external (IE) rotation moments, and anteroposterior forces at 0°, 30°, and 90° of flexion. We measured the resulting tibiofemoral angulations and translations. We also quantified the forces carried by the medial and lateral collateral ligaments (MCL/LCL) via serial sectioning of these structures and use of the principle of superposition. Results: Mid-level inserts reduced varus angulations compared to PS inserts by a median of 0.4°, 0.9°, and 1.5° at 0°, 30°, and 90° of flexion, respectively, and reduced valgus angulations by a median of 0.3°, 1.0°, and 1.2° (p ≤ 0.027 for all comparisons). Mid-level inserts reduced net IE rotations by a median of 5.6°, 14.7°, and 17.5° at 0°, 30°, and 90°, respectively (p = 0.012). Mid-level inserts reduced anterior tibial translation only at 90° of flexion by a median of 3.0 millimetres (p = 0.036). With an applied varus moment, the mid-level insert decreased LCL force compared to the PS insert at all three flexion angles that were tested (p ≤ 0.036). In contrast, with a valgus moment the mid-level insert did not reduce MCL force. With an applied internal rotation moment, the mid-level insert decreased LCL force at 30° and 90° by a median of 25.7 N and 31.7 N, respectively (p = 0.017 and p = 0.012). With an external rotation moment, the mid-level insert decreased MCL force at 30° and 90° by a median of 45.7 N and 20.0 N, respectively (p ≤ 0.017 for all comparisons). With an applied anterior load, MCL and LCL forces showed no differences between the two inserts at 30° and 90° of flexion. Conclusion: The mid-level insert used in this study decreased coronal and axial plane laxities compared to the PS insert, but its stabilizing benefit in the sagittal plane was limited. Both mid-level and PS inserts depended on the MCL to resist anterior loads during a simulated clinical exam of anterior laxity.

13.
J Arthroplasty ; 38(10): 2131-2136, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37142071

RESUMEN

BACKGROUND: Despite renewed interest in cementless fixation of total knee implants, many surgeons have anecdotal concerns about slower recovery and higher early pain scores. We sought to analyze 90-day opioid utilizations, inhospital pain scores, and patient-reported outcome measures (PROMs) in patients undergoing primary cemented versus cementless total knee arthroplasty (TKA). METHODS: We retrospectively identified a cohort of opioid naïve patients undergoing primary TKA for osteoarthritis. There were 186 patients who had cementless TKAs matched 1:6 with 1,116 who received a cemented TKAs based on age (±6 years), body mass index (BMI) (±5), and sex. We compared inhospital pain scores, 90-day opioid utilizations in morphine milligram equivalents (MMEs), and early postoperative PROMs. RESULTS: The cemented and cementless cohorts had similar lowest (0.09 versus 0.08), highest (7.36 versus 7.34), and average (3.26 versus 3.27) pain scores using numeric rating scale (P > .05). They received similar inhospital (90 versus 102, P = .176), discharge (315 versus 315, P = .483), and total (687 versus 720, P = .547) MMEs. They had similar average inpatient hourly opioid consumption (2.5 versus 2.5 MMEs/hour, P = .965). Average refills 90 days postoperatively were similar in both cohorts (1.5 versus 1.4 refills, P = .893). Also, preoperative, 6-week, 3-month, delta 6-week, and delta 3-month PROMs scores were similar between cemented and cementless cohorts (P > .05) CONCLUSION: This matched study demonstrated similar in-hospital pain scores and opioid utilization, total MMEs prescribed within 90 days, and PROMs at 6 weeks and 3 months postoperatively between cemented and cementless TKAs. LEVEL OF EVIDENCE: III, retrospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Analgésicos Opioides/uso terapéutico , Estudios Retrospectivos , Pacientes Internos , Dolor
14.
Int Orthop ; 47(5): 1243-1247, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36864185

RESUMEN

PURPOSE: Pelvic tilt (PT) is important to consider when planning total hip arthroplasty (THA) due to its dynamic impact on acetabular orientation. The degree of sagittal pelvic rotation varies during functional activities and can be difficult to measure without proper imaging. The purpose of this study was to evaluate PT variation in the supine, standing, and seated positions. METHODS: A multi-centre cross-sectional study was performed that included 358 THA patients who had preo-perative PT measured from supine CT scan and standing and upright seated lateral radiographs. Supine, standing, and seated PT and associated changes between functional positions were evaluated. Anterior PT was assigned a positive value. RESULTS: In the supine position, mean PT was 4° (range, -35° to 20°), where 23% had posterior PT and 69% anterior PT. In the standing position, mean PT was 1° (range, -23° to 29°), where 40% had posterior PT and 54% anterior PT. In the seated position, mean PT was -18° (range, -43° to 47°), where 95% had posterior PT and 4% anterior PT. From standing to seated, the pelvis rotated posteriorly in 97% of cases (maximum 60°) with 16% of cases considered stiff (change ≤ 10°) and 18% of cases considered hypermobile (change ≥ 30°). CONCLUSION: Patients undergoing THA have marked PT variation in the supine, standing, and seated positions. There was wide variability in PT change from standing to seated, with 16% of patients considered stiff and 18% considered hypermobile. Functional imaging should be performed on patients prior to THA to allow for more accurate planning.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Estudios Transversales , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Postura , Pelvis/cirugía
15.
J Arthroplasty ; 38(6S): S290-S296.e1, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36907386

RESUMEN

BACKGROUND: A specific total knee arthroplasty (TKA) implant system was recently recalled for high incidence of early polymeric wear and osteolysis. We analyzed the early outcomes of aseptic revision with these implants. METHODS: We identified 202 aseptic revision TKAs of this implant system performed at a single institution between 2010 and 2020. Revision indications included aseptic loosening (n = 120), instability (n = 55), and polymeric wear/osteolysis (n = 27). Components were revised in 145 cases (72%) and isolated polyethylene insert exchange occurred in 57 cases (28%). Kaplan-Meier and Cox proportional hazards analyses were used to determine survivorship free from all-cause rerevision and rerevision risk factors. RESULTS: At 2 and 5 years, survivorship free from all-cause rerevision was 89 and 76% in the polyethylene exchange cohort versus 92 and 84% in the component revision cohort (P = .5). At 2 and 5 years, survivorship in revision with components from the same manufacturer was 89 and 80% compared to 95 and 86% in revision with components from a different manufacturer (P = .2). Among re-revisions (n = 30), cones (37%), sleeves (7%), hinge/distal femoral replacement implants were frequently used (13%). Men had increased risk for rerevision (hazard ratio = 2.3, P = .04). CONCLUSION: In this series of aseptic revision TKAs performed on a now-recalled implant system, survivorship free from rerevision was lower than expected when components from the same manufacturer were utilized, but comparable to contemporary reports when both the components were revised with an alternative implant system. Metaphyseal fixation with cones and sleeves as well as highly constrained implants was frequently utilized at time of rerevision TKA. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteólisis , Masculino , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Osteólisis/epidemiología , Osteólisis/etiología , Osteólisis/cirugía , Falla de Prótesis , Diseño de Prótesis , Prótesis de la Rodilla/efectos adversos , Reoperación , Polietileno , Estudios Retrospectivos , Resultado del Tratamiento , Articulación de la Rodilla/cirugía
16.
J Arthroplasty ; 38(6): 1172-1176, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36878437

RESUMEN

BACKGROUND: Dual mobility (DM) liners were introduced to reduce instability in total hip arthroplasty. They were found to allow for motion predominantly at the femoral head and the inner bearing of the acetabular liner; however, little is known if this motion is sufficient to alter polyethylene material characteristics. We assessed cross-link (XL) density and oxidation index (OI) measurements of the inner and outer bearing articulations. METHODS: Thirty-seven DM liners were collected with a duration of implantation greater than 2 years. Clinical and demographic data were collected from a chart review. A cylinder was cored from the apex of each liner and cut into 4.5 mm long inner and outer diameter segments for XL density swell ratio testing. The OI was measured from sagittal 100 µm microtome slices using Fourier transform infrared spectroscopy. Student's t-tests were used to determine differences in OI and XL density between the bearings. Spearman's correlation assessed relationships between patient demographics, OI, and XL density. Duration of implantation for the cohort was a mean of 35 (range, 24-96) months. RESULTS: The inner and outer bearing had similar median XL densities (0.17 mol/dm3 versus 0.17 mol/dm3, P = .6). The inner bearing had an increased OI when compared to the outer bearing (0.16 versus 0.13, P = .008). The OI was inversely correlated with XL density (r = -0.50, P = .002). CONCLUSION: Small differences were found in oxidation between the inner and outer bearing of the DM construct. Failures at an average of 3 years indicate low levels of oxidation, unlikely to impact the mechanical properties of the material.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Polietileno , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Polietileno/química , Diseño de Prótesis , Falla de Prótesis
17.
Bone Joint J ; 105-B(3): 277-283, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36854324

RESUMEN

The purpose of this study was to assess mid-term survivorship following primary total knee arthroplasty (TKA) with Optetrak Logic components and identify the most common revision indications at a single institution. We identified a retrospective cohort of 7,941 Optetrak primary TKAs performed from January 2010 to December 2018. We reviewed the intraoperative findings of 369 TKAs that required revision TKA from January 2010 to December 2021 and the details of the revision implants used. Kaplan-Meier analysis was used to determine survivorship. Cox regression analysis was used to examine the impact of patient variables and year of implantation on survival time. The estimated survivorship free of all-cause revision was 98% (95% confidence interval (CI) 97% to 98%), 95% (95% CI 95% to 96%), and 86% (95% CI 83% to 88%) at two, five, and ten years, respectively. In 209/369 revisions there was a consistent constellation of findings with varying severity that included polyethylene wear and associated synovitis, osteolysis, and component loosening. This failure mode, which we refer to as aseptic mechanical failure, was the most common revision indication. The mean time from primary TKA to revision for aseptic mechanical failure was five years (5 months to 11 years). In this series of nearly 8,000 primary TKAs performed with a specific implant, we identified a lower-than-expected mid-term survivorship and a high number of revisions with a unique presentation. This study, along with the recent recall of the implant, confirms the need for frequent monitoring of patients with Optetrak TKAs given the incidence of polyethylene failure, osteolysis, and component loosening.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteólisis , Humanos , Estudios Retrospectivos , Supervivencia , Polietileno
18.
J Arthroplasty ; 38(6S): S190-S195, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36813213

RESUMEN

BACKGROUND: Knee instability is a leading cause of dissatisfaction following total knee arthroplasty (TKA). Instability can involve abnormal laxity in multiple directions including varus-valgus (VV) angulation, anterior-posterior (AP) translation, and internal-external rotation (IER). No existing arthrometer objectively quantifies knee laxity in all three of these directions. The study objectives were to verify the safety and assess reliability of a novel multiplanar arthrometer. METHODS: The arthrometer utilized a five degree-of-freedom instrumented linkage. Two examiners each conducted two tests on the leg that had received a TKA of 20 patients (mean age 65 years (range, 53-75); 9 men, 11 women), with nine and eleven distinct patients tested at 3-month and 1-year postoperative time points, respectively. AP forces from -10 to 30 Newtons, VV moments of ±3 Newton-meters, and IER moments of ±2.5 Newton-meters were applied to each subject's replaced knee. Severity and location of knee pain during testing were assessed using a visual analog scale. Intraexaminer and interexaminer reliabilities were characterized using intraclass correlation coefficients. RESULTS: All subjects successfully completed testing. Pain during testing averaged 0.7 (out of possible 10; range, 0-2.5). Intraexaminer reliability was >0.77 for all loading directions and examiners. Interexaminer reliability and 95% confidence intervals were 0.85 (0.66-0.94), 0.67 (0.35-0.85), and 0.54 (0.16-0.79) in the VV, IER, and AP directions, respectively. CONCLUSION: The novel arthrometer was safe for evaluating AP, VV, and IER laxities in subjects who had received TKA. This device could be used to examine relationships between laxity and patient perceptions of knee instability.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Inestabilidad de la Articulación , Masculino , Humanos , Femenino , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Reproducibilidad de los Resultados , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Rodilla/cirugía , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Rango del Movimiento Articular
19.
J Arthroplasty ; 38(6S): S363-S367, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36813214

RESUMEN

BACKGROUND: Fractures of the polyethylene post are a rare but known complication after posterior-stabilized (PS) total knee arthroplasty (TKA). We evaluated the polyethylene and patient characteristics for 33 primary PS polyethylene components that were revised with fractured posts. METHODS: We identified 33 PS inserts revised between 2015 and 2022. Patient characteristics collected included age at index TKA, sex, body mass index, length of implantation (LOI), and patient-reported details on events surrounding the post fracture. Implant characteristics recorded were manufacturer, cross-linking properties (highly cross-linked polyethylene [XLPE] versus ultra-high molecular weight polyethylene [UHMWPE]), wear characteristics based on subjective scoring of the articular surfaces and scanning electron microscopy (SEM) of fracture surfaces. Mean age at index surgery was 55 years (range, 35 to 69), mean body mass index was 29.5 (range, 18.5 to 37.2), and mean LOI was 10.0 (range, 4 to 26). RESULTS: Total surface damage scores were significantly higher in the UHMWPE group versus the XLPE group (57.3 versus 44.2, P = .003). SEM demonstrated fracture initiation at the posterior edge of the post in 10 of 13 cases. UHMWPE fracture surfaces posts had more tufted, irregularly clamshell features, while XLPE posts had more precise clamshell marking and a diamond pattern in the region of acute, final fracture. CONCLUSION: Characteristics of PS post fracture differed between XLPE and UHMWPE implants, with fractures occurring in the XLPE with less generalized surface damage, after a shorter LOI, and with SEM evaluation indicative of a more brittle fracture pattern.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fracturas Óseas , Prótesis de la Rodilla , Polietileno , Adulto , Anciano , Humanos , Persona de Mediana Edad , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fracturas Óseas/cirugía , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Falla de Prótesis
20.
Arch Orthop Trauma Surg ; 143(1): 311-315, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34302523

RESUMEN

INTRODUCTION: A history of COVID-19 (Coronavirus Disease 2019), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) may have an impact on hemoglobin and ferritin levels predisposing patients to increased blood transfusion requirements following total joint arthroplasty (TJA). The current study compares ferritin levels, hemoglobin levels, and transfusion rates between SARS-CoV-2 IgG positive and SARS-CoV-2 IgG negative TJA patients. MATERIALS AND METHODS: Preoperative ferritin levels, pre- and postoperative hemoglobin levels, postoperative change in hemoglobin, and transfusion rates of 385 consecutive SARS-CoV-2 IgG positive patients undergoing TJA were compared to those of 5156 consecutive SARS-CoV-2 IgG negative patients undergoing TJA. RESULTS: Preoperative hemoglobin levels were significantly lower in SARS-CoV-2 IgG positive patients [13.3 g/dL (range 8.9-17.7 g/dL)] compared to 13.5 g/dl (7.3-18.3 g/dL; p value 0.03). Ferritin levels were significantly lower in SARS-CoV-2 IgG positive patients (mean of 106.1 ng/ml (2.1-871.3.3 ng/ml) vs. 123.7 ng/ml (1.4-1985 ng/ml) (p value 0.02)). Hemoglobin on postoperative day (POD) one, after four-six weeks, and transfusion rates did not differ between the two groups. CONCLUSION: Although preoperative hemoglobin and ferritin levels are lower in SARS-CoV2 IgG positive patients, there was no difference in hemoglobin on POD one, recovery of hemoglobin levels at four-six weeks postoperatively, and transfusion rates after surgery. Routine ferritin testing prior to TJA is not recommended in SARS-CoV-2 IgG positive patients.


Asunto(s)
COVID-19 , Ferritinas , Hemoglobinas , Humanos , Transfusión Sanguínea , Ferritinas/sangre , Hemoglobinas/análisis , Hemorragia , Inmunoglobulina G , SARS-CoV-2 , Periodo Preoperatorio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA