Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Molecules ; 27(6)2022 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-35335202

RESUMEN

Hemp and hemp seed press cake­a by-product of hemp oil production­are high-protein, gluten-free raw materials that are often used to enhance the nutritional value of breads. The addition of hemp materials, however, often negatively impacts the technological parameters of breads. Consequently, this study investigated whether and how much the addition of various by-products of hemp seed press cakes to wheat bread mixtures adversely affects the texture and colour profile. The texture profile and colour were determined using a texture analyser and tristimulus measurements. The particle size of raw materials was also measured. Principal component analysis was then used to visualise the correlation between all measured values as well as nutritional parameters. The results showed that the addition of only 1% of some hemp raw materials caused significant technological changes (p > 0.05). Hemp raw materials increased bread hardness and decreased elasticity. The colour of breads containing 1% hemp was also visibly darker than the reference bread. The addition of more hemp led to further darkening and the deterioration of the technological parameters of the products. Consequently, while various hemp materials have high nutritional value, a balance with sensory properties, e.g., textural and colour, has to be reached.


Asunto(s)
Pan , Cannabis , Pan/análisis , Extractos Vegetales , Semillas , Triticum
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 249: 119342, 2021 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-33360568

RESUMEN

The global demand for natural products grows rapidly, intensifying the request for the development of high-throughput, fast, non-invasive tools for quality control applicable on-site. Moisture content is one of the most important quality parameters of natural products. It determines their market suitability, stability and shelf life and should preferably be constantly monitored. Miniaturized near-infrared (NIR) spectroscopy is a powerful method for on-site analysis, potentially fulfilling this requirement. Here, a feasibility study for applicability and analytical performance of three miniaturized NIR spectrometers and two benchtop instruments was evaluated in that scenario. The case study involved 192 dried plant extracts composed of five different plants harvested in different countries at various times within two years. The reference analysis by Karl Fischer titration determined the water content in this sample set between 1.36% and 6.47%. For the spectroscopic analysis half of the samples were laced with a drying agent to comply with the industry standard. The performance of various calibration models for NIR analysis was evaluated on the basis of root-mean square error of prediction (RMSEP) determined for an independent test set. Partial least squares regression (PLSR), Gaussian process regression (GPR) and artificial neural network (ANN) models were constructed for the spectral sets from each instrument. GPR and ANN models performed superior for all samples measured by handheld spectrometers and for native ones analyzed by benchtop instruments. Moreover, the accuracy penalty when analyzing native samples was lower for GPR and ANN prediction as well. With GPR or ANN calibration, miniaturized spectrometers offered the prediction performance at the level of the benchtop instruments. Therefore, in this analytical application miniaturized spectrometers can be used on-site with no penalty to the performance vs. laboratory-based NIR analysis.


Asunto(s)
Redes Neurales de la Computación , Espectroscopía Infrarroja Corta , Calibración , Análisis de los Mínimos Cuadrados , Distribución Normal
3.
Metabolomics ; 16(12): 128, 2020 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-33319318

RESUMEN

INTRODUCTION: Metabolomics studies are not routine when quantifying amino acids (AA) in congenital heart disease (CHD). OBJECTIVES: Comparative analysis of 24 AA in serum by traditional high-performance liquid chromatography (HPLC) based on ion exchange and ninhydrin derivatisation followed by photometry (PM) with ultra-high-performance liquid chromatography and phenylisothiocyanate derivatisation followed by tandem mass spectrometry (TMS); interpretation of findings in CHD patients and controls. METHODS: PM: Sample analysis as above (total run time, ~ 119 min). TMS: Sample analysis by AbsoluteIDQ® p180 kit assay (BIOCRATES Life Sciences AG, Innsbruck, Austria), which employs PITC derivatisation; separation of analytes on a Waters Acquity UHPLC BEH18 C18 reversed-phase column, using water and acetonitrile with 0.1% formic acid as the mobile phases; and quantification on a Triple-Stage Quadrupole tandem mass spectrometer (Thermo Fisher Scientific, Waltham, MA) with electrospray ionisation in the presence of internal standards (total run time, ~ 8 min). Calculation of coefficients of variation (CV) (for precision), intra- and interday accuracies, limits of detection (LOD), limits of quantification (LOQ), and mean concentrations. RESULTS: Both methods yielded acceptable results with regard to precision (CV < 10% PM, < 20% TMS), accuracies (< 10% PM, < 34% TMS), LOD, and LOQ. For both Fontan patients and controls AA concentrations differed significantly between methods, but patterns yielded overall were parallel. CONCLUSION: Serum AA concentrations differ with analytical methods but both methods are suitable for AA pattern recognition. TMS is a time-saving alternative to traditional PM under physiological conditions as well as in patients with CHD. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier NCT03886935, date of registration March 27th, 2019 (retrospectively registered).


Asunto(s)
Aminoácidos/sangre , Cromatografía Líquida de Alta Presión , Cardiopatías Congénitas/sangre , Cardiopatías Congénitas/diagnóstico , Ninhidrina , Espectrometría de Masas en Tándem , Biomarcadores , Estudios de Casos y Controles , Cromatografía Líquida de Alta Presión/métodos , Humanos , Metabolómica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem/métodos
4.
Talanta ; 205: 120115, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31450462

RESUMEN

A set of 42 millet (panicum miliaceum L.) samples was investigated for its protein content using standard Kjeldahl analysis and near-infrared spectroscopy. The performance of three handheld spectrometers was compared to a benchtop instrument. The used spectrometers operate in different regions of the NIR, which gives interesting insights into the applicability of each region. Additionally, semi-automated, consumer-oriented multivariate data analysis was compared to sophisticated data evaluation. The performance of the near-infrared instruments was compared using important statistical parameters of the established cross- and test set validated partial least squares regression (PLS-R) models. Milled and intact samples were analysed, in order to further evaluate the importance of homogeneity. The results showed that the benchtop spectrometer is capable of accurately analysing protein content of millet grains, with root mean square error (RMSEP) values for milled and intact grains of approximately 0.5%. Two PLS-R models of handheld instruments also yielded good results for milled grains with RMSEP values of about 0.6%. The semi-automated multivariate data analysis showed some drawbacks compared to standard data processing software. For intact grains, however, similar results could be achieved.


Asunto(s)
Panicum/química , Proteínas de Plantas/análisis , Análisis de Datos , Grano Comestible/química , Análisis de los Mínimos Cuadrados , Análisis Multivariante , Panicum/clasificación , Espectrofotometría Infrarroja/instrumentación , Espectrofotometría Infrarroja/métodos
5.
Molecules ; 24(3)2019 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-30682872

RESUMEN

The performance of a newly developed pocket-sized near-infrared (NIR) spectrometer was investigated by analysing 46 cheese samples for their water and fat content, and comparing results with a benchtop NIR device. Additionally, the automated data analysis of the pocket-sized spectrometer and its cloud-based data analysis software, designed for laypeople, was put to the test by comparing performances to a highly sophisticated multivariate data analysis software. All developed partial least squares regression (PLS-R) models yield a coefficient of determination (R²) of over 0.9, indicating high correlation between spectra and reference data for both spectrometers and all data analysis routes taken. In general, the analysis of grated cheese yields better results than whole pieces of cheese. Additionally, the ratios of performance to deviation (RPDs) and standard errors of prediction (SEPs) suggest that the performance of the pocket-sized spectrometer is comparable to the benchtop device. Small improvements are observable, when using sophisticated data analysis software, instead of automated tools.


Asunto(s)
Queso/análisis , Análisis de los Alimentos/instrumentación , Espectroscopía Infrarroja Corta/instrumentación , Grasas/química , Análisis de los Mínimos Cuadrados , Análisis Multivariante , Análisis de Componente Principal , Agua/química
6.
Talanta ; 189: 233-240, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30086911

RESUMEN

The performance of three portable NIR spectrometers was compared by analysing the total antioxidant capacity (TAC) of different species of gluten-free grains. TAC is often used to evaluate the quality of foods and was determined using Folin-Ciocalteu measurements and used as reference data for establishing PLS-R models with NIR data. NIRS enables fast and non-invasive measurements. The microPhazir RX and the MicroNIR 2200 are broadly used in chemical and pharmaceutical industries, whereas SCiO is a pocket-sized, consumer-oriented spectrometer. The devices work in different regions of the NIR spectrum and their performances was compared using statistical parameters. 77 samples were measured and analysed using the software The Unscrambler X, as well as SCiO-Lab. All models established were cross- and test set validated. The multivariate data processing using The Unscrambler X yielded similar results as SCiO-Lab. The best model was established for non-milled samples measured with the MicroNIR 2200 and analysed using The Unscrambler X.


Asunto(s)
Antioxidantes/análisis , Grano Comestible/química , Espectroscopía Infrarroja Corta/instrumentación , Antioxidantes/química , Glútenes/análisis , Análisis Multivariante , Estándares de Referencia , Espectroscopía Infrarroja Corta/normas
7.
Clin Oral Investig ; 21(5): 1697-1705, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27704295

RESUMEN

OBJECTIVES: Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. MATERIALS AND METHODS: CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. RESULTS: Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. CONCLUSIONS: All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CLINICAL RELEVANCE: CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.


Asunto(s)
Diseño Asistido por Computadora , Materiales Dentales/química , Diseño de Dentadura , Metilmetacrilato/química , Cromatografía Líquida de Alta Presión , Ensayo de Materiales
8.
Appl Spectrosc ; 71(7): 1600-1612, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27956591

RESUMEN

Water absorbed to poly(methyl methacrylate) (PMMA)-based CAD/CAM (computer-assisted design/computer-assisted manufacturing) prosthodontics can alter their properties including hardness and stability. In the present contribution, water absorption and desorption kinetics under defined experimental conditions were monitored employing several supplementary and advanced Fourier transform infrared (FT-IR) spectroscopic techniques in combination with multivariate analysis (MVA). In this synergistic vibrational spectroscopic multimethod approach, first a novel near-infrared (NIR) diffuse fiber optic probe reflection spectroscopic method was established for time-resolved analysis of water uptake within seven days under controlled conditions. Near-infrared water absorbance spectra in a wavenumber range between 5288-5100 cm-1 (combination band) and 5424-5352 cm-1 (second overtone) were used establishing corresponding calibration and validation models to quantify the amount of water in the milligram range. Therefore, 14 well-defined samples exposed to prior optimized experimental conditions were taken into consideration. The average daily water uptake conducting reference analysis was calculated as 22 mg/day for one week. Additionally, in this study for the first time NIR two-dimensional correlation spectroscopy (2D-COS) was conducted to monitor and interpret the spectral dynamics of water absorption on the prosthodontics in a wavenumber range of 5100-5300 cm-1. For sensitive time-resolved recording of water desorption, a recently developed high-temperature, high-pressure FT-IR reaction cell with water-free ultra-dry in situ and operando operation was applied. The reaction cell, as well as the sample holder, was fully made of quartz glass, with no hot metal or ceramic parts in the vicinity of the high temperature zone. Applying a temperature gradient in the range of 25-150 ℃, mid-infrared (MIR) 2D-COS was successfully conducted to get insights into the dynamic behavior of O-H (1400-1800 cm-1) absorption bands with increasing temperature over time and the release of CO2 (2450 cm-1) from the polymers. In addition, an ATR FT-IR imaging setup was optimized in order to investigate the surface homogeneity of the PMMA-based resins with a spatial resolution to 2 µm. From this vibrational spectroscopic multimethod approach and the collection of several analytical data, conclusions were drawn as to which degree the surface structure and/or its porosity have an impact onto the amount of water absorption.

SELECCIÓN DE REFERENCIAS