Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.374
Filtrar
1.
J Soc Cardiovasc Angiogr Interv ; 3(3Part B): 101293, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-39131219

RESUMEN

Background: Coronary artery disease (CAD) in patients with severe aortic stenosis (AS) is common and may be associated with worse outcomes. Computed tomography coronary angiography (CTCA) and fractional flow reserve derived from computed tomography (FFRCT) are tools for comprehensive coronary assessment. The utility and safety of CTCA and FFRCT in the work-up for transcatheter aortic valve replacement (TAVR) is not established, especially in an evolving landscape that involves younger TAVR patients. The FUTURE-AS Registry will assess the utility and safety of cardiac-optimized CTCA and FFRCT to evaluate CAD and guide referral for downstream invasive coronary angiography (ICA) in patients with severe AS being considered for TAVR. Methods: FUTURE-AS is an international, prospective, multicenter registry of patients with severe AS referred for TAVR being assessed for CAD with CTCA and FFRCT. The primary end point is the per-patient sensitivity and negative predictive value of CTCA and FFRCT for identifying anatomical and physiologically significant CAD compared to ICA and invasive FFR. The safety end point is the incidence of symptomatic hypotension or bradycardia requiring intervention following the administration of nitroglycerin or ß-blocker medications. Feasibility end points include the incidence of noninterpretable CTCA scans and CTCA scans not adequate for FFR analysis. Other utility end points include specificity, positive predictive value, and accuracy of CTCA and FFRCT. Lastly, the potential of a CTCA and FFRCT guided strategy to defer pre-TAVR ICA will be assessed. Conclusions: FUTURE-AS will characterize the utility, safety, and feasibility of CTCA and FFRCT for coronary assessment pre-TAVR.

2.
J Med Toxicol ; 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39107657

RESUMEN

INTRODUCTION: Vortioxetine is an antidepressant with a multimodal mechanism of action. It is used as a treatment option for patients with major depressive episodes. There have only been two previously reported non-fatal overdoses of vortioxetine; neither of these were analytically confirmed There has also been one case of serotonin syndrome potentially related to vortioxetine and two deaths where vortioxetine was detected. We report here a non-fatal analytically confirmed case of vortioxetine overdose. CASE REPORT: A 32-year-old male presented to the emergency department (ED) 12-13 h after oral ingestion of 1,260 mg of vortioxetine and 350 mg of diazepam. A family member reported that he had been drowsy after the overdose, but his level of consciousness and observations (heart rate, blood pressure and temperature) were normal on review by the pre-hospital emergency services and on arrival to the ED. During a period of observation, he did not develop any features of serotonin syndrome or any other significant toxicity. Toxicological analysis of a blood sample taken in the ED detected vortioxetine (plasma concentration 457 ng/mL 10 h after ingestion) and sub-therapeutic concentrations of diazepam and pregabalin. DISCUSSION: Despite having a plasma vortioxetine concentration nearly 15-times therapeutic vortioxetine concentrations, this patient did not develop any significant toxicity. In particular he did not develop any clinical or biochemical features of serotonin toxicity that would be expected with this class of antidepressant. Additional reporting of analytically confirmed vortioxetine overdoses will allow clinicians and licensing authorities to further understand the safety of this medication in overdose.

3.
Am J Sports Med ; 52(10): 2532-2540, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39101611

RESUMEN

BACKGROUND: Matrix-induced autologous chondrocyte implantation (MACI) has demonstrated encouraging outcomes in the treatment of knee cartilage defects, although limited research is available on its longer term (≥10 years) sustainability in the patellofemoral joint. PURPOSE: To report the clinical and radiological outcomes at ≥10 years in a prospectively recruited cohort of patients undergoing MACI in the patellofemoral joint and compare outcomes in patients undergoing MACI on the patella versus the trochlea. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: The current study prospectively enrolled 95 patients who underwent patellofemoral MACI, of whom 29 (13 patella, 16 trochlea) underwent concomitant tibial tubercle osteotomy. Patients were assessed preoperatively and at 2, 5, and ≥10 years using a range of patient-reported outcome measures (PROMs) including the Knee injury and Osteoarthritis Outcome Score, the 36-item Short Form Health Survey, and the frequency and severity of knee pain as well as patient satisfaction, full active knee flexion and extension, and peak isokinetic knee extensor and flexor torques. High-resolution magnetic resonance imaging (MRI) was performed to assess pertinent graft parameters, as well as determine an overall MRI composite score, per the Magnetic Resonance Observation of Cartilage Repair Tissue scoring system. Results were analyzed according to the graft location (patella or trochlea). RESULTS: Of the 95 patients recruited, 82 patients (41 patella, 41 trochlea) were available for a clinical review at ≥10 years after surgery (mean follow-up, 11.9 years [range, 10-15 years]). For the whole patellofemoral MACI cohort, all PROMs significantly improved over time (P < .05), with no significant changes (P > .05) observed in any MRI-based score from 2 to ≥10 years after surgery. At ≥10 years, 90.2% (n = 74) were satisfied with MACI in relieving their knee pain, and 85.4% (n = 70) were satisfied with the improvement in their ability to participate in sports. No differences (P > .05) were observed in PROMs between those undergoing patellar MACI and those undergoing trochlear MACI, although a significant group effect was observed for limb symmetry indices of knee extensor (P = .009) and flexor (P = .041) strength, which were greater in those undergoing patellar (vs trochlear) MACI. No statistically significant differences (P > .05) were observed between patellar and trochlear grafts on any MRI-based measure. In the cohort assessed at ≥10 years after surgery, 4 patients (2 patella, 2 trochlea) demonstrated graft failure on MRI scans, although a further 3 patients (all trochlea) were omitted from the ≥10-year review for having already progressed to total knee arthroplasty. CONCLUSION: Good clinical scores, high levels of patient satisfaction, and adequate graft survivorship were observed at ≥10 years after MACI on the patella and trochlea.


Asunto(s)
Condrocitos , Articulación Patelofemoral , Trasplante Autólogo , Humanos , Articulación Patelofemoral/cirugía , Articulación Patelofemoral/diagnóstico por imagen , Condrocitos/trasplante , Adulto , Femenino , Masculino , Estudios de Seguimiento , Estudios Prospectivos , Adulto Joven , Medición de Resultados Informados por el Paciente , Persona de Mediana Edad , Imagen por Resonancia Magnética , Adolescente , Rótula/cirugía , Rótula/diagnóstico por imagen , Satisfacción del Paciente , Resultado del Tratamiento , Cartílago Articular/cirugía , Cartílago Articular/lesiones , Cartílago Articular/diagnóstico por imagen
4.
Protein Expr Purif ; 224: 106578, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39153561

RESUMEN

Current biological research requires simple protein bioseparation methods capable of purifying target proteins in a single step with high yields and purities. Conventional affinity tag-based approaches require specific affinity resins and expensive proteolytic enzymes for tag removal. Purification strategies based on self-cleaving aggregating tags have been previously developed to address these problems. However, these methods often utilize C-terminal cleaving contiguous inteins which suffer from premature cleavage, resulting in significant product loss during protein expression. In this work, we evaluate two novel mutants of the Mtu RecA ΔI-CM mini-intein obtained through yeast surface display for improved protein purification. When used with the elastin-like-polypeptide (ELP) precipitation tag, the novel mutants - ΔI-12 and ΔI-29 resulted in significantly higher precursor content, product purity and process yield compared to the original Mtu RecA ΔI-CM mini-intein. Product purities ranging from 68 % to 94 % were obtained in a single step for three model proteins - green fluorescent protein (GFP), maltose binding protein (MBP) and beta-galactosidase (beta-gal). Further, high cleaving efficiency was achieved after 5 h under most conditions. Overall, we have developed improved self-cleaving precipitation tags which can be used for purifying a wide range of proteins cheaply at laboratory scale.

6.
J Interpers Violence ; : 8862605241270008, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39135455

RESUMEN

Suicide negatively impacts societies worldwide. A particular area of concern is the prevalence of suicide among Latinx youth, as research indicates that suicide behaviors among Latinx in the United States and youth in Latin America have increased drastically over the last decade. Reducing suicide stigma is a key factor in promoting youth help-seeking behaviors regarding suicidality. Previous research suggests that a relationship with a trusted adult may influence the likelihood of an adolescent contacting a suicide crisis line. Our study seeks to further the research of how parents can influence youth perceptions of suicide by studying the relationship between parent and child suicide stigma. Data were collected from parent-child dyads throughout Mexico. The Stigma of Suicide Scale Short Form was used to measure suicide stigma among adult and youth participants independently. Results suggest that parent suicide stigma was a significant predictor of youth suicide stigma, that male youth in our sample had higher suicide stigma than female youth, and that access to healthcare services was associated with lower suicide stigma. Results are discussed considering unique cultural factors in Mexico such as familismo. If future research reinforces the findings of this study, suicide stigma programs might be more effective if targeted at the entire family unit rather than just adolescents.

7.
Clin Toxicol (Phila) ; 62(7): 441-445, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38958109

RESUMEN

INTRODUCTION: Intravenous lipid emulsion is used in the rescue treatment of certain poisonings. A complication is interference with laboratory analyses. The aim of this study was to determine the impact of intravenous lipid emulsion on routine laboratory analysis of coagulation parameters ex vivo and determine if any of the analytical techniques remain reliable. METHODS: Samples were obtained from 19 healthy volunteers and divided in triplicate. One sample served as a control, and the other two were diluted to simulate the treatment of an average adult with Intralipid® 20 per cent Fresenius Kabi 100 mL (dilution-1) or 500 mL (dilution-2). Coagulation tests performed were prothrombin time, activated prothrombin time, D-dimer concentration and fibrinogen. Coagulation testing was performed by three techniques. Test-1 was performed on a Sysmex CN6000 analyzer. Test-2 was performed with a manual mechanical endpoint method using the semi-automated Stago KC4 Delta. Test-3 involved high-speed centrifugation before repeat testing on the Sysmex CN6000 analyzer. RESULTS: For test-1, only nine (47 per cent) samples in dilution-1 could be analyzed for coagulation tests, and no coagulation tests could be analyzed for dilution-2 because of lipaemia. For test-2 and test-3, all samples could be analyzed, and all results of both testing methods fell within the limits of the laboratory reference range. DISCUSSION: Difficulties in laboratory analysis of patients having received intravenous lipid emulsion are due to multiple factors. Most automated coagulation analyzers use optical measurements, which can be unreliable in the presence of a high intravenous lipid concentration. By altering the lipaemia in the testing solution using high-speed centrifugation or by using manual mechanical endpoint detection, we were able to obtain reliable results. These findings are limited by the use of an ex vivo method and healthy volunteers. CONCLUSIONS: This ex vivo model confirms that Intralipid® interferes with routine coagulation studies. It is important that clinicians are aware and inform their laboratories of its administration.


Asunto(s)
Coagulación Sanguínea , Emulsiones Grasas Intravenosas , Humanos , Pruebas de Coagulación Sanguínea/métodos , Adulto , Masculino , Femenino , Coagulación Sanguínea/efectos de los fármacos , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Persona de Mediana Edad , Tiempo de Protrombina , Adulto Joven , Aceite de Soja , Fosfolípidos , Reproducibilidad de los Resultados , Emulsiones
8.
J Med Toxicol ; 20(3): 271-277, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38839732

RESUMEN

INTRODUCTION: Synthetic cannabinoid receptor agonists (SCRAs) are associated with significant toxicity and are increasingly used in electronic vaping devices. We assessed the availability of SCRA vaping products to UK purchasers on the surface web. METHODS: An internet snapshot survey was performed between October 2022 and January 2023 on 'google.com' using the search terms "buy c-liquid vape", "buy herbal incense vape liquid", "buy cannabis vape liquid", "buy hashish vape liquid", "buy K2 vape liquid". RESULTS: 62 websites selling 128 SCRA vaping brands were identified. Most were purportedly based in the USA (41 websites, 66%) and most sold other controlled substances. Purchase incentives offered included discreet packaging (38, 61%), discounts for bulk purchase (34, 55%) and tracked delivery (30, 48%). Many websites stated SCRA products were: not for human consumption (41, 66%), for research purposes only (15, 24%), or legal (28, 45%). Websites sold a median (IQR) of 16 (7-25) SCRA vaping brands. Almost all were bottles of vaping liquid (1220/1225, 99.6%). The most common bottle size was 5mL (60%), the median (IQR) total volume of SCRA liquid per sale was 50mL (10-200mL). Median (IQR) price was £3.39/mL (£2.01/mL- £5.29/mL). Price decreased with increasing volume purchased (£6.58/mL for ≤ 5mL, £1.60/mL for > 200mL). CONCLUSION: SCRA vaping products are easily obtainable online, in both small and bulk quantities. Information provided to purchasers on safety and legality is lacking or misleading. Further studies are needed to confirm the chemistry of these products. Policymakers should consider steps to limit the potential harm caused by the purchase and use of these products.


Asunto(s)
Agonistas de Receptores de Cannabinoides , Sistemas Electrónicos de Liberación de Nicotina , Internet , Vapeo , Humanos , Comercio , Encuestas y Cuestionarios , Reino Unido
9.
JACC Cardiovasc Interv ; 17(11): 1340-1351, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866457

RESUMEN

BACKGROUND: The etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms. OBJECTIVES: The authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology. METHODS: TAV explants were obtained from the EXPLANT THV registry and clinical institutions. Hydrodynamic assessment was performed using a heart valve pulse duplicator system under physiological conditions. Micro-computed tomography, high-resolution photography, high speed video, and hematoxylin and eosin staining were used to evaluate the morphological appearance, leaflet kinematics, and calcium burden of TAVs. RESULTS: A total of 14 explants were evaluated: 10 self-expanding CoreValve/Evolut TAVs (Medtronic), 3 balloon-expandable SAPIEN 3 TAVs (Edwards Lifesciences), and 1 mechanically expandable Lotus TAV (Boston Scientific). The median patient age at explantation was 73.0 years (Q1-Q3: 64.5-80.0 years), with a time to explantation of 4 years 1 month (1 year 5 months to 4 years 11 months). Six TAV explants were found to have leaflet calcification (162.4 mm3; 58.8-603.0 mm3), and 8 had no calcification detectable by micro-computed tomography and histology. All samples had impaired leaflet kinematics. There was no significant difference in the hydrodynamic mean gradient between calcified (47.2 mm Hg; 26.6-74.1 mm Hg) and noncalcified (27.6 mm Hg; 15.2-36.7 mm Hg; P = 0.28) TAVs. Leaflet calcification had a weak but nonsignificant association with the hydrodynamic mean gradient (r = 0.42; P = 0.14). CONCLUSIONS: TAV function can be severely impacted by noncalcific and calcific mechanisms of tissue degeneration. Importantly, functional stenosis can occur in TAVs in the absence of obvious and significant calcification.


Asunto(s)
Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Hidrodinámica , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Microtomografía por Rayos X , Humanos , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Calcinosis/cirugía , Femenino , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Persona de Mediana Edad , Factores de Tiempo , Remoción de Dispositivos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Fenómenos Biomecánicos , Ensayo de Materiales , Grabación en Video
10.
bioRxiv ; 2024 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-38712200

RESUMEN

The role of extracellular vesicles (EVs) in human health and disease has garnered considerable attention over the past two decades. However, while several types of EVs are known to interact dynamically with the extracellular matrix and there is great potential value in producing high-fidelity EV micropatterns, there are currently no label-free, high-resolution, and tunable platform technologies with this capability. We introduce Light-induced Extracellular Vesicle Adsorption (LEVA) as a powerful solution to rapidly advance the study of matrix- and surface-bound EVs and other particles. The versatility of LEVA is demonstrated using commercial GFP-EV standards, EVs from glioblastoma bioreactors, and E. coli outer membrane vesicles (OMVs), with the resulting patterns used for single EV characterization, single cell migration on migrasome-mimetic trails, and OMV-mediated neutrophil swarming. LEVA will enable rapid advancements in the study of matrix- and surface-bound EVs and other particles, and should encourage researchers from many disciplines to create novel diagnostic, biomimetic, immunoengineering, and therapeutic screening assays.

11.
Emerg Med J ; 41(7): 440-445, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38763520

RESUMEN

The Royal College of Emergency Medicine Toxicology Special Interest Group in collaboration with the UK National Poisons Information Service and the Clinical Toxicology Department at Guy's and St Thomas' NHS Foundation Trust has produced guidance to support clinicians working in the ED with the assessment and management of adults with acute opioid toxicity.Considerations regarding identification of acute opioid toxicity are discussed and recommendations regarding treatment options and secondary prevention are made. There is a focus on making recommendations on the best available evidence.


Asunto(s)
Analgésicos Opioides , Servicio de Urgencia en Hospital , Humanos , Analgésicos Opioides/efectos adversos , Analgésicos Opioides/uso terapéutico , Adulto , Reino Unido , Guías de Práctica Clínica como Asunto , Sobredosis de Opiáceos/terapia
12.
Catheter Cardiovasc Interv ; 104(1): 105-114, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38819623

RESUMEN

BACKGROUND: The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry. AIM: We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves. METHODS: A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post-TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area-derived annular diameter, and performance of pre-dilation and post-dilation. RESULTS: The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post-dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post-dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post-TAVR mean gradient (r = -0.324, p < 0.001). CONCLUSION: Relative stent expansion ≥90% was associated with the performance of post-dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Femenino , Masculino , Estudios Retrospectivos , Anciano de 80 o más Años , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Anciano , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Valvuloplastia con Balón/efectos adversos , Factores de Riesgo , Estados Unidos , Stents
13.
Plants (Basel) ; 13(8)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38674573

RESUMEN

During the past 30 years, there has been a growing belief in and promotion of agroecosystem diversity for pest management and future food production as an agroecological or nature-based approach. Monoculture agriculture, which produces most of our food, is considered to be highly vulnerable to pests in contrast to plant species-diverse agroecosystems which may possess a greater abundance of natural enemies, keeping pest populations under control. In this paper, we question the role of crop diversity for pest management and explore the relationship between crop and associated diversity and pests through the following processes: environmental stresses that favor monodominance; evolutionary adaptations that resist insect herbivores (genetic resistance response); mechanisms of spatial escape from insect herbivores (escape response); and the role of crop-associated biodiversity. We present strong evidence that not only questions the high vulnerability of monocultures to pest damage but also supports why monocultures continue to produce most of the world's food. Reference is made to the importance of targeted plant breeding and the role of trans-continental crop introduction supported by efficient quarantine for pest management. We conclude that-with the exception of irrigated rice-much more research is needed to better understand the role of crop diversity in agroecosystems for pest management and food production.

14.
Clin Res Cardiol ; 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38619575

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) serves a growing range of patients with severe aortic stenosis (AS). TAVI has evolved to a streamlined procedure minimizing length of hospital stay. AIMS: To evaluate the safety and efficacy of an early discharge (ED) strategy after TAVI. METHODS: We performed an international, multi-center, prospective observational single-arm study in AS patients undergoing TAVI with the ACURATE valve platform. Eligibility for ED was assessed prior to TAVI and based on prespecified selection criteria. Discharge ≤ 48 h was defined as ED. Primary Valve Academic Research Consortium (VARC)-3-defined 30-day safety and efficacy composite endpoints were landmarked at 48 h and compared between ED and non-ED groups. RESULTS: A total of 252 patients were included. The median age was 82 [25th-75th percentile, 78-85] years and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.2% [25th-75th percentile, 1.6-3.3]. ED and non-ED were achieved in 173 (69%) and 79 (31%) patients respectively. Monitoring for conduction disturbances was the principal reason for non-ED (33%). Overall, at 30 days, all-cause mortality was 1%, new permanent pacemaker rate was 4%, and valve- or procedure-related rehospitalization was 4%. There was no difference in the primary safety and efficacy endpoint between the ED and non-ED cohorts (OR 0.84 [25th-75th percentile, 0.31-2.26], p = 0.73, and OR 0.97 [25th-75th percentile, 0.46-2.06], p = 0.94). The need for rehospitalization was similarly low for ED and non-ED groups. CONCLUSION: Early discharge after TAVI with the ACURATE valve is safe and feasible in selected patients. Rhythm monitoring and extended clinical observation protracted hospital stay.

15.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38587261

RESUMEN

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Bioprótesis/efectos adversos , Insuficiencia Cardíaca , Estimación de Kaplan-Meier , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Falla de Prótesis , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
16.
J Environ Manage ; 356: 120561, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38479290

RESUMEN

Recorded particulate matter (PM2.5) hourly trends are compared for fifteen urban recording sites distributed across central England for the period 2018 to 2022. They include 10 urban-background and five urban-traffic (roadside) sites with some located within the same urban area. The sites all show consistent background and peak distributions with mean annual values and standard deviations higher for 2018 and 2019 than for 2020 to 2022. The objective of this study is to demonstrate that trend attributes extracted from hourly recorded univariate PM2.5 trends at these sites can be used to provide reliable short-term hourly predictions and provide valuable insight into the regional variations in the recorded trends. Fifteen trend attributes extracted from the prior 12 h (t-1 to t-12) of recorded PM2.5 data were compiled and used as input to four supervised machine learning models (SML) to forecast PM2.5 concentrations up to 13 h ahead (t0 to t+12). All recording sites delivered forecasts with similar ranges of error levels for specific hours ahead which are consistent with their PM2.5 recorded ranges. Forecasting results for four representative sites are presented in detail using models trained and cross-validated with 2020 and 2021 hourly data to forecast 2021 and 2022 hourly data, respectively. A novel optimized feature selection procedure using a suite of five optimizers is used to improve the efficiency of the forecasting models. The LASSO and support vector regression models generate the best and most generalizable hourly PM2.5 forecasts from trained and validated SML models with mean average error (MAE) of between ∼1 and ∼3 µg/m3 for t0 to t+3 h ahead. A novel overfitting indicator, exploiting the cross-validation mean values, demonstrates that these two models are not affected by overfitting. Forecasts for t+6 to t+12 h forward generate higher MAE values between ∼3 and ∼4 µg/m3 due to their tendency to underestimate some of the extreme PM2.5 peaks. These findings indicate that further model refinements are required to generate more reliable short-term predictions for the t+6 to t+24 h ahead.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Contaminantes Atmosféricos/análisis , Ciudades , Monitoreo del Ambiente/métodos , Material Particulado/análisis , Inglaterra , Predicción , Aprendizaje Automático , Contaminación del Aire/análisis
17.
EuroIntervention ; 20(6): e376-e388, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506739

RESUMEN

BACKGROUND: There are limited data regarding treatment for failed balloon-expandable transcatheter heart valves (THVs) in redo-transcatheter aortic valve implantation (TAVI). AIMS: We aimed to assess THV performance, neoskirt height and expansion when performing redo-TAVI with the ACURATE platform inside a SAPIEN 3 (S3) compared to redo-TAVI with an S3 in an S3. METHODS: Redo-TAVI was performed on the bench using each available size of the S3, the ACURATE neo2 (ACn2) and the next-generation ACURATE Prime XL (AC XL) implanted at 2 different depths within 20 mm/23 mm/26 mm/29 mm S3s serving as the "failed" index THV. Hydrodynamic testing was performed to assess THV function. Multimodality assessment was performed using photography, X-ray, microcomputed tomography (micro-CT), and high-speed videos. RESULTS: The ACURATE in S3 combinations had favourable hydrodynamic performance compared to the S3 in S3 for all size combinations. In the 20 mm S3, redo-TAVI with the ACn2 had lower gradients compared to the S3 (mean gradient 16.3 mmHg for the ACn2 vs 24.7 mmHg for the 20 mm S3 in 20 mm S3). Pinwheeling was less marked for the ACURATE THVs than for the S3s. On micro-CT, the S3s used for redo-TAVI were underexpanded across all sizes. This was also observed for the ACURATE platform, but to a lesser extent. CONCLUSIONS: Redo-TAVI with an ACn2/AC XL within an S3 has favourable hydrodynamic performance and less pinwheeling compared to an S3 in S3. This comes at the price of a taller neoskirt.


Asunto(s)
Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Microtomografía por Rayos X , Catéteres , Válvulas Cardíacas
18.
Lab Chip ; 24(7): 1867-1874, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38487919

RESUMEN

Microfluidic lab-on-a-chip technologies enable the analysis and manipulation of small fluid volumes and particles at small scales and the control of fluid flow and transport processes at the microscale, leading to the development of new methods to address a broad range of scientific and medical challenges. Microfluidic and lab-on-a-chip technologies have made a noteworthy impact in basic, preclinical, and clinical research, especially in hematology and vascular biology due to the inherent ability of microfluidics to mimic physiologic flow conditions in blood vessels and capillaries. With the potential to significantly impact translational research and clinical diagnostics, technical issues and incentive mismatches have stymied microfluidics from fulfilling this promise. We describe how accessibility, usability, and manufacturability of microfluidic technologies should be improved and how a shift in mindset and incentives within the field is also needed to address these issues. In this report, we discuss the state of the microfluidic field regarding current limitations and propose future directions and new approaches for the field to advance microfluidic technologies closer to translation and clinical use. While our report focuses on using blood as the prototypical biofluid sample, the proposed ideas and research directions can be extrapolated to other areas of hematology, oncology, biology, and medicine.


Asunto(s)
Técnicas Analíticas Microfluídicas , Microfluídica , Microfluídica/métodos , Técnicas Analíticas Microfluídicas/métodos , Dispositivos Laboratorio en un Chip , Investigación Biomédica Traslacional
19.
Adv Aerodyn ; 6(1): 7, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38464493

RESUMEN

This paper investigates a specific case of one of the most popular fluid dynamic simulations, the incompressible flow around an airfoil (NACA 0012 here) at a high Reynolds number (6×106). OpenFOAM software was used to study the effect of domain size and four common choices of boundary conditions on airfoil lift, drag, surface friction, and pressure. We also examine the relation between boundary conditions and the velocity, pressure, and vorticity distributions throughout the domain. In addition to the common boundary conditions, we implement the "point vortex" boundary condition that was introduced many years ago but is now rarely used. We also applied the point vortex condition for the outlet pressure instead of using the traditional Neumann condition. With the airfoil generating significant lift at incidence angles of 5∘,10∘, and 14∘, we confirm a previous finding that the boundary conditions combine with domain size to produce an induced (pressure) drag. The change in the pressure drag with domain size is significant for the commonly-used boundary conditions but is much smaller for the point vortex alternative. The point vortex boundary condition increases the execution time, but this is more than offset by the reduction in domain size needed to achieve a specified accuracy in the lift and drag. This study also estimates the error in total drag and lift due to domain size and shows it can be almost eliminated using the point vortex boundary condition. We also used the impulse form of the momentum equations to study the relation between drag and lift and spurious vorticity, which is generated as a result of using non-exact boundary conditions. These equations reveal that the spurious vorticity throughout the domain is associated with cancelling circulation around the domain boundaries.

20.
Hum Brain Mapp ; 45(4): e26625, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38433665

RESUMEN

Estimated age from brain MRI data has emerged as a promising biomarker of neurological health. However, the absence of large, diverse, and clinically representative training datasets, along with the complexity of managing heterogeneous MRI data, presents significant barriers to the development of accurate and generalisable models appropriate for clinical use. Here, we present a deep learning framework trained on routine clinical data (N up to 18,890, age range 18-96 years). We trained five separate models for accurate brain age prediction (all with mean absolute error ≤4.0 years, R2 ≥ .86) across five different MRI sequences (T2 -weighted, T2 -FLAIR, T1 -weighted, diffusion-weighted, and gradient-recalled echo T2 *-weighted). Our trained models offer dual functionality. First, they have the potential to be directly employed on clinical data. Second, they can be used as foundation models for further refinement to accommodate a range of other MRI sequences (and therefore a range of clinical scenarios which employ such sequences). This adaptation process, enabled by transfer learning, proved effective in our study across a range of MRI sequences and scan orientations, including those which differed considerably from the original training datasets. Crucially, our findings suggest that this approach remains viable even with limited data availability (as low as N = 25 for fine-tuning), thus broadening the application of brain age estimation to more diverse clinical contexts and patient populations. By making these models publicly available, we aim to provide the scientific community with a versatile toolkit, promoting further research in brain age prediction and related areas.


Asunto(s)
Encéfalo , Recuerdo Mental , Humanos , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Preescolar , Encéfalo/diagnóstico por imagen , Difusión , Neuroimagen , Aprendizaje Automático
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA