Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Cogn Neurodyn ; 18(3): 1153-1166, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38826647

RESUMEN

The investigation into the distinctive difference of gait is of significance for the clinical diagnosis of neurodegenerative diseases. However, human gait is affected by many factors like behavior, occupation and so on, and they may confuse the gait differences among Parkinson's disease, amyotrophic lateral sclerosis, and Huntington's disease. For the purpose of examining distinctive gait differences of neurodegenerative diseases, this study extracts various features from both vertical ground reaction force and time intervals. Moreover, refined Lempel-Ziv complexity is proposed considering the detailed distribution of signals based on the median and quartiles. Basic features (mean, coefficient of variance, and the asymmetry index), nonlinear dynamic features (Hurst exponent, correlation dimension, largest Lyapunov exponent), and refined Lempel-Ziv complexity of different neurodegenerative diseases are compared statistically by violin plot and Kruskal-Wallis test to reveal distinction and regularities. The comparative analysis results illustrate the gait differences across these neurodegenerative diseases by basic features and nonlinear dynamic features. Classification results by random forest indicate that the refined Lempel-Ziv complexity can robustly enhance the diagnosis accuracy when combined with basic features.

2.
Comput Biol Med ; 164: 107270, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37478714

RESUMEN

As the motor symptoms of Parkinson's disease (PD) are complex and influenced by many factors, it is challenging to quantify gait abnormalities adequately using a single type of signal. Therefore, a wearable multisource gait monitoring system is developed to perform a quantitative analysis of gait abnormalities for improving the effectiveness of the clinical diagnosis. To detect multisource gait data for an accurate evaluation of gait abnormalities, force sensitive sensors, piezoelectric sensors, and inertial measurement units are integrated into the devised device. The modulation circuits and wireless framework are designed to simultaneously collect plantar pressure, dynamic deformation, and postural angle of the foot and then wirelessly transmit these collected data. With the designed system, multisource gait data from PD patients and healthy controls are collected. Multisource features for quantifying gait abnormalities are extracted and evaluated by a significance test of difference and correlation analysis. The results show that the features extracted from every single type of data are able to quantify the health status of the subjects (p < 0.001, ρ > 0.50). More importantly, the validity of multisource gait data is verified. The results demonstrate that the gait feature fusing multisource data achieves a maximum correlation coefficient of 0.831, a maximum Area Under Curve of 0.9206, and a maximum feature-based classification accuracy of 88.3%. The system proposed in this study can be applied to the gait analysis and objective evaluation of PD.


Asunto(s)
Enfermedad de Parkinson , Dispositivos Electrónicos Vestibles , Humanos , Análisis de la Marcha , Enfermedad de Parkinson/diagnóstico , Marcha , Monitoreo Fisiológico
3.
Digit Health ; 9: 20552076231173569, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37214662

RESUMEN

Objective: Neurodegenerative diseases affect millions of families around the world, while various wearable sensors and corresponding data analysis can be of great support for clinical diagnosis and health assessment. This systematic review aims to provide a comprehensive overview of the existing research that uses wearable sensors and features for the diagnosis of neurodegenerative diseases. Methods: A systematic review was conducted of studies published between 2015 and 2022 in major scientific databases such as Web of Science, Google Scholar, PubMed, and Scopes. The obtained studies were analyzed and organized into the process of diagnosis: wearable sensors, feature extraction, and feature selection. Results: The search led to 171 eligible studies included in this overview. Wearable sensors such as force sensors, inertial sensors, electromyography, electroencephalography, acoustic sensors, optical fiber sensors, and global positioning systems were employed to monitor and diagnose neurodegenerative diseases. Various features including physical features, statistical features, nonlinear features, and features from the network can be extracted from these wearable sensors, and the alteration of features toward neurodegenerative diseases was illustrated. Moreover, different kinds of feature selection methods such as filter, wrapper, and embedded methods help to find the distinctive indicator of the diseases and benefit to a better diagnosis performance. Conclusions: This systematic review enables a comprehensive understanding of wearable sensors and features for the diagnosis of neurodegenerative diseases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA