Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
BMC Pulm Med ; 24(1): 203, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38658883

RESUMEN

BACKGROUND: Bronchial arterial embolization (BAE) has been accepted as an effective treatment for bronchiectasis-related hemoptysis. However, rare clinical trials compare different sizes of specific embolic agents. This study aims to evaluate whether different Embosphere microsphere sizes change the outcome of BAE. METHODS: A retrospective review was conducted on consecutive patients with bronchiectatic hemoptysis who were scheduled to undergo BAE treatment during a period from January 2018 to December 2022. The patients received BAE using microspheres of different sizes: group A patients were treated with 500-750 µm microspheres, and group B patients were treated with 700-900 µm microspheres. The cost of embolic microspheres (Chinese Yuan, CNY), duration of hospitalization, complications, and hemoptysis-free survival were compared between patients in group A and those in group B. A Cox proportional hazards regression model was used to identify predictors of recurrent hemoptysis. RESULTS: Median follow-up was 30.2 months (range, 20.3-56.5 months). The final analysis included a total of 112 patients (49-77 years of age; 45 men). The patients were divided into two groups: group A (N = 68), which received 500-750 µm Embosphere microspheres, and group B (N = 44), which received 700-900 µm Embosphere microspheres. Except for the cost of embolic microspheres(group A,5314.8 + 1301.5 CNY; group B, 3644.5 + 1192.3 CNY; p = 0.042), there were no statistically significant differences in duration of hospitalization (group A,7.2 + 1.4 days; group B, 8 + 2.4days; p = 0.550), hemoptysis-free survival (group A, 1-year, 2-year, 3-year, 85.9%, 75.8%, 62.9%; group B, 1-year, 2-year, 3-year, 88.4%, 81.2%,59.4%;P = 0.060), and complications(group A,26.5%; group B, 38.6%; p = 0.175) between the two groups. No major complications were observed. The multivariate analysis results revealed that the presence of cystic bronchiectasis (OR 1.61, 95% CI 1.12-2.83; P = 0.001) and systemic arterial-pulmonary shunts (SPSs) (OR 1.52, 95% CI 1.10-2.72; P = 0.028) were independent risk factors for recurrent bleeding. CONCLUSIONS: For the treatment of BAE in patients with bronchiectasis-related hemoptysis, 500-750 µm diameter Embosphere microspheres have a similar efficacy and safety profile compared to 700-900 µm diameter Embosphere microspheres, especially for those without SPSs or cystic bronchiectasis. Furthermore, the utilization of large-sized (700-900 µm) Embosphere microspheres is associated with the reduced cost of an embolic agent.


Asunto(s)
Resinas Acrílicas , Arterias Bronquiales , Bronquiectasia , Embolización Terapéutica , Hemoptisis , Microesferas , Humanos , Hemoptisis/terapia , Hemoptisis/etiología , Estudios Retrospectivos , Masculino , Femenino , Embolización Terapéutica/métodos , Persona de Mediana Edad , Anciano , Bronquiectasia/complicaciones , Bronquiectasia/terapia , Gelatina/administración & dosificación , Gelatina/uso terapéutico , Resultado del Tratamiento , Tamaño de la Partícula
2.
BMC Gastroenterol ; 20(1): 174, 2020 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-32503426

RESUMEN

BACKGROUND: Currently, side-by-side (SBS) and stent-in-stent (SIS) are the two main techniques for stent deployment to treat hilar biliary obstructions. Previous studies comparing these two techniques are very limited, and thus, no consensus has been reached on which technique is better. The purpose of this study is to compare the clinical efficacy and safety of SBS and SIS deployment via a percutaneous approach for malignant hilar biliary obstruction. METHODS: From July 2012 to April 2019, 65 patients with malignant hilar biliary obstruction who underwent bilateral stenting using either the SBS or SIS techniques were included in this study. Among them, 27 patients underwent SIS stent insertion (SIS group), and the remaining 38 patients underwent SBS stent insertion (SBS group). Technical success, improvement of jaundice, complications, duration of stent patency, and overall survival were evaluated. RESULTS: Technical success was achieved in all patients in the two groups. The serum bilirubin level decreased more rapidly 1 week after the procedures in the SBS group than in the SIS group (P = 0.02). Although the total complication rate did not differ between the two groups, cholangitis was found to be more frequent in the SIS group (P = 0.04). The median stent patency was significantly longer in the SBS group (149 days) than in the SIS group (75 days; P = 0.02). The median overall survival did not significantly differ between the two groups (SBS vs. SIS, 155 days vs. 143 days; P > 0.05). CONCLUSIONS: Percutaneous transhepatic bilateral stenting using either the SBS or SIS technique is safe and effective in the management of malignant hilar biliary obstruction. However, SBS offers a quicker improvement of jaundice, a lower incidence of cholangitis after the procedure, and a longer stent patency period than SIS.


Asunto(s)
Neoplasias de los Conductos Biliares/cirugía , Procedimientos Quirúrgicos del Sistema Biliar/métodos , Colestasis/cirugía , Tumor de Klatskin/cirugía , Stents , Anciano , Neoplasias de los Conductos Biliares/sangre , Neoplasias de los Conductos Biliares/complicaciones , Procedimientos Quirúrgicos del Sistema Biliar/instrumentación , Bilirrubina/sangre , Colangitis/epidemiología , Colangitis/etiología , Colestasis/sangre , Colestasis/etiología , Femenino , Humanos , Incidencia , Ictericia/sangre , Ictericia/etiología , Ictericia/cirugía , Tumor de Klatskin/sangre , Tumor de Klatskin/complicaciones , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA