RESUMEN
The present study examined the necessity of cement-augmented pedicle screw fixation in osteoporotic patients with single-segment isthmic spondylolisthesis.Fifty-nine cases were reviewed retrospectively. Thirty-three cases were in the polymethylmethacrylate-augmented pedicle screw (PMMA-PS) group, and the other 26 cases were in the conventional pedicle screw (CPS) group. Evaluation data included operation time, intraoperative blood loss, hospitalization cost, hospitalization days, rates of fusion, screw loosening, bone cement leakage, visual analogue scale (VAS) scores, Oswestry disability index (ODI), lumbar lordosis (LL), pelvic tilt (PT) and sacral slope (SS).The operation time and blood loss in the CPS group decreased significantly compared to those in the PMMA-PS group. The average hospitalization cost of the PMMA-PS group was significantly higher than that of the CPS group. There was no significant difference in the average hospital stay between the 2 groups. The initial and last follow-up postoperative VAS and ODI scores improved significantly in the two groups. There were no significant differences in VAS and ODI between the 2 groups at each time point. The last postoperative spine-pelvic parameters were significantly improved compared with those preoperatively. In the PMMA-PS group, the fusion rate was 100%. The fusion rate was 96.15% in the CPS group. No significant difference was found between the two groups for the fusion rate. Nine patients in the PMMA-PS group had bone cement leakage. There was no screw loosening in the PMMA-PS group. There were 2 cases of screw loosening in the CPS group. There were no significant differences in screw loosening, postoperative adjacent segment fractures, postoperative infection or postoperative revision between the 2 groups. The use of PMMA-PS on a regular basis is not recommended in posterior lumbar interbody fusion for the treatment of single-segment isthmic spondylolisthesis with osteoporosis.
Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Espondilolistesis , Humanos , Cementos para Huesos/uso terapéutico , Espondilolistesis/cirugía , Polimetil Metacrilato , Estudios Retrospectivos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Resultado del TratamientoRESUMEN
Background: Facet tropism is defined as the asymmetry between the left and right facet joints relative to the sagittal plane. Published clinical studies have found that facet tropism is associated with cervical disc herniation. However, the relationship between the facet orientation and the side of cervical disc herniation remains controversial. Therefore, this study used the finite-element technique to investigate the biomechanical effects of the sagittal angle of the cervical facet joints on the cervical intervertebral disc. Objective: The biomechanical effects of the sagittal angle of the cervical facet joint on the cervical disc and facet joint were investigated using the finite-element technique. Methods: The finite-element model was constructed using computed tomography scans of a 26-year-old female volunteer. First, a cervical model was constructed from C3 to C7. The model was verified using data from previously published studies. Second, the facet orientation at the C5-C6 level was altered to simulate different sagittal angles of cervical facet joints. Five models, F70, F80, F90, F100, and F110, were simulated with different facet joint orientations (70°, 80°, 90°, 100°, and 110° facet joint angles at the left side, respectively, and 90° facet joint angles at the right side) at the C5-C6 facet joints. In each model, annular fibres stress and facet cartilage pressure were studied under six pure moments and two combined moments. Results: Comparing the stress of the annulus fibres in flexion combined with right axial rotation and in flexion combined with left axial rotation in the same model, no difference in the maximum stress of the annulus fibres was noted between these two different moments in the F90 model, whereas differences of 12.80%, 8.84%, 14.95% and 33.32% were noted in the F70, F80, F100 and F110 models, respectively. The same trend was observed when comparing the maximum stress of the annulus fibres in each model during left and right axial rotation. No differences in annular fibres stress and facet cartilage pressure were noted among the five models in flexion, extension, lateral bending, left axial rotation, and flexion combined with left axial rotation in this study. However, compared with the F70 model in flexion combined with right axial rotation, the annulus fibres stress of the F80, F90, F100, and F110 models increased by 5.53%, 13.03%, 35.04%, and 72.94%, respectively, and the pressure of the left facet joint of these models decreased by 5.65%, 12.10%, 18.41%, and 25.74%, respectively. The same trend was observed in the right axial moment. Conclusion: Facet tropism leads to unbalanced stress distribution on the annulus fibres at the cervical intervertebral disc. The greater the sagittal angle of the facet joint, the greater the annular fibres stress on this side. We hypothesised that the side with the larger sagittal angle of the facet joint exhibits a greater risk of disc herniation.