Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Microbiol Infect ; 28(12): 1547-1557, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35718347

RESUMEN

BACKGROUND: Rapid and accurate diagnosis of herpes simplex virus (HSV)-1 and -2 (HSV1/2) in cerebrospinal fluid (CSF) is important for patient management. OBJECTIVES: Summarize the diagnostic accuracy of commercial rapid sample-to-answer PCR assays (results in <90 minutes, without a separate nucleic acid extraction step) for HSV1/2 detection in CSF. DATA SOURCES: Four databases (MEDLINE, EMBASE, Scopus, and CENTRAL) and five conference abstract datasets from January 2012 to March 2022. STUDY ELIGIBILITY CRITERIA: Eligible diagnostic accuracy studies provided sufficient data for the construction of a standard diagnostic accuracy two-by-two table. PARTICIPANTS: Patients with suspected meningitis and/or encephalitis. TESTS: FilmArray Meningitis-Encephalitis Panel and Simplexa HSV 1&2 Direct Kit PCR. REFERENCE STANDARD: Real-time PCR assay. ASSESSMENT OF RISK OF BIAS: Two investigators independently extracted data, rated risk of bias, and assessed quality using QUADAS-2. METHODS OF DATA SYNTHESIS: Accuracy estimates were pooled using Bayesian random effects models. RESULTS: Thirty-one studies were included (27 FilmArray; 4 Simplexa), comprising 9924 samples, with 95 HSV-1 and 247 HSV-2 infections. Pooled FilmArray sensitivities were 84.3% (95% credible interval, 72.3-93.0) and 92.9% (95% credible interval (CrI), 82.0-98.5) for HSV-1 and HSV-2, respectively; specificities were 99.8% (95% CrI, 99.6-99.9) and 99.9% (95% CrI, 99.9-100). Pooled Simplexa sensitivities were 97.1% (95% CrI, 88.1-99.6) and 97.9% (95% CrI, 89.6-99.9), respectively; specificities were 98.9% (95% CrI, 96.8-99.7) and 98.9% (95% CrI, 97.1-99.7). Pooled FilmArray sensitivities favoured industry-sponsored studies by 10.0 and 13.0 percentage points for HSV-1 and HSV-2, respectively. Incomplete reporting frequently led to unclear risk of bias. Several FilmArray studies did not fully report true negative data leading to their exclusion. CONCLUSIONS: Our results suggest Simplexa is accurate for HSV1/2 detection in CSF. Moderate FilmArray sensitivity for HSV-1 suggests additional testing and/or repeat CSF sampling is required for suspected HSV encephalitis when the HSV-1 result is negative. Low prevalence of HSV-1 infections limited summary estimates' precision. Underreporting of covariates limited exploration of heterogeneity.


Asunto(s)
Encefalitis por Herpes Simple , Herpesvirus Humano 1 , Meningitis , Humanos , Herpesvirus Humano 1/genética , Teorema de Bayes , Sensibilidad y Especificidad , Encefalitis por Herpes Simple/diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Meningitis/diagnóstico , Líquido Cefalorraquídeo
2.
Cochrane Database Syst Rev ; 3: CD013694, 2021 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-33755189

RESUMEN

BACKGROUND: Tuberculosis is a leading cause of infectious disease-related death and is one of the top 10 causes of death worldwide. The World Health Organization (WHO) recommends the use of specific rapid molecular tests, including Xpert MTB/RIF or Xpert Ultra, as initial diagnostic tests for the detection of tuberculosis and rifampicin resistance in people with signs and symptoms of tuberculosis. However, the WHO estimates that nearly one-third of all active tuberculosis cases go undiagnosed and unreported. We were interested in whether a single test, Xpert MTB/RIF or Xpert Ultra, could be useful as a screening test to close this diagnostic gap and improve tuberculosis case detection. OBJECTIVES: To estimate the accuracy of Xpert MTB/RIF and Xpert Ultra for screening for pulmonary tuberculosis in adults, irrespective of signs or symptoms of pulmonary tuberculosis in high-risk groups and in the general population. Screening "irrespective of signs or symptoms" refers to screening of people who have not been assessed for the presence of tuberculosis symptoms (e.g. cough). To estimate the accuracy of Xpert MTB/RIF and Xpert Ultra for detecting rifampicin resistance in adults screened for tuberculosis, irrespective of signs and symptoms of pulmonary tuberculosis in high-risk groups and in the general population. SEARCH METHODS: We searched 12 databases including the Cochrane Infectious Diseases Group Specialized Register, MEDLINE and Embase, on 19 March 2020 without language restrictions. We also reviewed reference lists of included articles and related Cochrane Reviews, and contacted researchers in the field to identify additional studies. SELECTION CRITERIA: Cross-sectional and cohort studies in which adults (15 years and older) in high-risk groups (e.g. people living with HIV, household contacts of people with tuberculosis) or in the general population were screened for pulmonary tuberculosis using Xpert MTB/RIF or Xpert Ultra. For tuberculosis detection, the reference standard was culture. For rifampicin resistance detection, the reference standards were culture-based drug susceptibility testing and line probe assays. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data using a standardized form and assessed risk of bias and applicability using QUADAS-2. We used a bivariate random-effects model to estimate pooled sensitivity and specificity with 95% credible intervals (CrIs) separately for tuberculosis detection and rifampicin resistance detection. We estimated all models using a Bayesian approach. For tuberculosis detection, we first estimated screening accuracy in distinct high-risk groups, including people living with HIV, household contacts, people residing in prisons, and miners, and then in several high-risk groups combined. MAIN RESULTS: We included a total of 21 studies: 18 studies (13,114 participants) evaluated Xpert MTB/RIF as a screening test for pulmonary tuberculosis and one study (571 participants) evaluated both Xpert MTB/RIF and Xpert Ultra. Three studies (159 participants) evaluated Xpert MTB/RIF for rifampicin resistance. Fifteen studies (75%) were conducted in high tuberculosis burden and 16 (80%) in high TB/HIV-burden countries. We judged most studies to have low risk of bias in all four QUADAS-2 domains and low concern for applicability. Xpert MTB/RIF and Xpert Ultra as screening tests for pulmonary tuberculosis In people living with HIV (12 studies), Xpert MTB/RIF pooled sensitivity and specificity (95% CrI) were 61.8% (53.6 to 69.9) (602 participants; moderate-certainty evidence) and 98.8% (98.0 to 99.4) (4173 participants; high-certainty evidence). Of 1000 people where 50 have tuberculosis on culture, 40 would be Xpert MTB/RIF-positive; of these, 9 (22%) would not have tuberculosis (false-positives); and 960 would be Xpert MTB/RIF-negative; of these, 19 (2%) would have tuberculosis (false-negatives). In people living with HIV (1 study), Xpert Ultra sensitivity and specificity (95% CI) were 69% (57 to 80) (68 participants; very low-certainty evidence) and 98% (97 to 99) (503 participants; moderate-certainty evidence). Of 1000 people where 50 have tuberculosis on culture, 53 would be Xpert Ultra-positive; of these, 19 (36%) would not have tuberculosis (false-positives); and 947 would be Xpert Ultra-negative; of these, 16 (2%) would have tuberculosis (false-negatives). In non-hospitalized people in high-risk groups (5 studies), Xpert MTB/RIF pooled sensitivity and specificity were 69.4% (47.7 to 86.2) (337 participants, low-certainty evidence) and 98.8% (97.2 to 99.5) (8619 participants, moderate-certainty evidence). Of 1000 people where 10 have tuberculosis on culture, 19 would be Xpert MTB/RIF-positive; of these, 12 (63%) would not have tuberculosis (false-positives); and 981 would be Xpert MTB/RIF-negative; of these, 3 (0%) would have tuberculosis (false-negatives). We did not identify any studies using Xpert MTB/RIF or Xpert Ultra for screening in the general population. Xpert MTB/RIF as a screening test for rifampicin resistance Xpert MTB/RIF sensitivity was 81% and 100% (2 studies, 20 participants; very low-certainty evidence), and specificity was 94% to 100%, (3 studies, 139 participants; moderate-certainty evidence). AUTHORS' CONCLUSIONS: Of the high-risks groups evaluated, Xpert MTB/RIF applied as a screening test was accurate for tuberculosis in high tuberculosis burden settings. Sensitivity and specificity were similar in people living with HIV and non-hospitalized people in high-risk groups. In people living with HIV, Xpert Ultra sensitivity was slightly higher than that of Xpert MTB/RIF and specificity similar. As there was only one study of Xpert Ultra in this analysis, results should be interpreted with caution. There were no studies that evaluated the tests in people with diabetes mellitus and other groups considered at high-risk for tuberculosis, or in the general population.


Asunto(s)
Antibióticos Antituberculosos/farmacología , Farmacorresistencia Bacteriana , Mycobacterium tuberculosis/efectos de los fármacos , Reacción en Cadena de la Polimerasa/métodos , Rifampin/farmacología , Tuberculosis Pulmonar/diagnóstico , Adulto , Técnicas Bacteriológicas/métodos , Teorema de Bayes , Sesgo , Estudios de Cohortes , Estudios Transversales , Reacciones Falso Negativas , Reacciones Falso Positivas , Infecciones por VIH/complicaciones , Humanos , Mycobacterium tuberculosis/aislamiento & purificación , Sensibilidad y Especificidad , Esputo/microbiología , Tuberculosis Pulmonar/complicaciones , Tuberculosis Pulmonar/tratamiento farmacológico
3.
Cochrane Database Syst Rev ; 1: CD012768, 2021 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-33448348

RESUMEN

BACKGROUND: Xpert MTB/RIF Ultra (Xpert Ultra) and Xpert MTB/RIF are World Health Organization (WHO)-recommended rapid nucleic acid amplification tests (NAATs) widely used for simultaneous detection of Mycobacterium tuberculosis complex and rifampicin resistance in sputum. To extend our previous review on extrapulmonary tuberculosis (Kohli 2018), we performed this update to inform updated WHO policy (WHO Consolidated Guidelines (Module 3) 2020). OBJECTIVES: To estimate diagnostic accuracy of Xpert Ultra and Xpert MTB/RIF for extrapulmonary tuberculosis and rifampicin resistance in adults with presumptive extrapulmonary tuberculosis. SEARCH METHODS: Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, Web of Science, Latin American Caribbean Health Sciences Literature, Scopus, ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform, the International Standard Randomized Controlled Trial Number Registry, and ProQuest, 2 August 2019 and 28 January 2020 (Xpert Ultra studies), without language restriction. SELECTION CRITERIA: Cross-sectional and cohort studies using non-respiratory specimens. Forms of extrapulmonary tuberculosis: tuberculous meningitis and pleural, lymph node, bone or joint, genitourinary, peritoneal, pericardial, disseminated tuberculosis. Reference standards were culture and a study-defined composite reference standard (tuberculosis detection); phenotypic drug susceptibility testing and line probe assays (rifampicin resistance detection). DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data and assessed risk of bias and applicability using QUADAS-2. For tuberculosis detection, we performed separate analyses by specimen type and reference standard using the bivariate model to estimate pooled sensitivity and specificity with 95% credible intervals (CrIs). We applied a latent class meta-analysis model to three forms of extrapulmonary tuberculosis. We assessed certainty of evidence using GRADE. MAIN RESULTS: 69 studies: 67 evaluated Xpert MTB/RIF and 11 evaluated Xpert Ultra, of which nine evaluated both tests. Most studies were conducted in China, India, South Africa, and Uganda. Overall, risk of bias was low for patient selection, index test, and flow and timing domains, and low (49%) or unclear (43%) for the reference standard domain. Applicability for the patient selection domain was unclear for most studies because we were unsure of the clinical settings. Cerebrospinal fluid Xpert Ultra (6 studies) Xpert Ultra pooled sensitivity and specificity (95% CrI) against culture were 89.4% (79.1 to 95.6) (89 participants; low-certainty evidence) and 91.2% (83.2 to 95.7) (386 participants; moderate-certainty evidence). Of 1000 people where 100 have tuberculous meningitis, 168 would be Xpert Ultra-positive: of these, 79 (47%) would not have tuberculosis (false-positives) and 832 would be Xpert Ultra-negative: of these, 11 (1%) would have tuberculosis (false-negatives). Xpert MTB/RIF (30 studies) Xpert MTB/RIF pooled sensitivity and specificity against culture were 71.1% (62.8 to 79.1) (571 participants; moderate-certainty evidence) and 96.9% (95.4 to 98.0) (2824 participants; high-certainty evidence). Of 1000 people where 100 have tuberculous meningitis, 99 would be Xpert MTB/RIF-positive: of these, 28 (28%) would not have tuberculosis; and 901 would be Xpert MTB/RIF-negative: of these, 29 (3%) would have tuberculosis. Pleural fluid Xpert Ultra (4 studies) Xpert Ultra pooled sensitivity and specificity against culture were 75.0% (58.0 to 86.4) (158 participants; very low-certainty evidence) and 87.0% (63.1 to 97.9) (240 participants; very low-certainty evidence). Of 1000 people where 100 have pleural tuberculosis, 192 would be Xpert Ultra-positive: of these, 117 (61%) would not have tuberculosis; and 808 would be Xpert Ultra-negative: of these, 25 (3%) would have tuberculosis. Xpert MTB/RIF (25 studies) Xpert MTB/RIF pooled sensitivity and specificity against culture were 49.5% (39.8 to 59.9) (644 participants; low-certainty evidence) and 98.9% (97.6 to 99.7) (2421 participants; high-certainty evidence). Of 1000 people where 100 have pleural tuberculosis, 60 would be Xpert MTB/RIF-positive: of these, 10 (17%) would not have tuberculosis; and 940 would be Xpert MTB/RIF-negative: of these, 50 (5%) would have tuberculosis. Lymph node aspirate Xpert Ultra (1 study) Xpert Ultra sensitivity and specificity (95% confidence interval) against composite reference standard were 70% (51 to 85) (30 participants; very low-certainty evidence) and 100% (92 to 100) (43 participants; low-certainty evidence). Of 1000 people where 100 have lymph node tuberculosis, 70 would be Xpert Ultra-positive and 0 (0%) would not have tuberculosis; 930 would be Xpert Ultra-negative and 30 (3%) would have tuberculosis. Xpert MTB/RIF (4 studies) Xpert MTB/RIF pooled sensitivity and specificity against composite reference standard were 81.6% (61.9 to 93.3) (377 participants; low-certainty evidence) and 96.4% (91.3 to 98.6) (302 participants; low-certainty evidence). Of 1000 people where 100 have lymph node tuberculosis, 118 would be Xpert MTB/RIF-positive and 37 (31%) would not have tuberculosis; 882 would be Xpert MTB/RIF-negative and 19 (2%) would have tuberculosis. In lymph node aspirate, Xpert MTB/RIF pooled specificity against culture was 86.2% (78.0 to 92.3), lower than that against a composite reference standard. Using the latent class model, Xpert MTB/RIF pooled specificity was 99.5% (99.1 to 99.7), similar to that observed with a composite reference standard. Rifampicin resistance Xpert Ultra (4 studies) Xpert Ultra pooled sensitivity and specificity were 100.0% (95.1 to 100.0), (24 participants; low-certainty evidence) and 100.0% (99.0 to 100.0) (105 participants; moderate-certainty evidence). Of 1000 people where 100 have rifampicin resistance, 100 would be Xpert Ultra-positive (resistant): of these, zero (0%) would not have rifampicin resistance; and 900 would be Xpert Ultra-negative (susceptible): of these, zero (0%) would have rifampicin resistance. Xpert MTB/RIF (19 studies) Xpert MTB/RIF pooled sensitivity and specificity were 96.5% (91.9 to 98.8) (148 participants; high-certainty evidence) and 99.1% (98.0 to 99.7) (822 participants; high-certainty evidence). Of 1000 people where 100 have rifampicin resistance, 105 would be Xpert MTB/RIF-positive (resistant): of these, 8 (8%) would not have rifampicin resistance; and 895 would be Xpert MTB/RIF-negative (susceptible): of these, 3 (0.3%) would have rifampicin resistance. AUTHORS' CONCLUSIONS: Xpert Ultra and Xpert MTB/RIF may be helpful in diagnosing extrapulmonary tuberculosis. Sensitivity varies across different extrapulmonary specimens: while for most specimens specificity is high, the tests rarely yield a positive result for people without tuberculosis. For tuberculous meningitis, Xpert Ultra had higher sensitivity and lower specificity than Xpert MTB/RIF against culture. Xpert Ultra and Xpert MTB/RIF had similar sensitivity and specificity for rifampicin resistance. Future research should acknowledge the concern associated with culture as a reference standard in paucibacillary specimens and consider ways to address this limitation.


Asunto(s)
Antibióticos Antituberculosos/uso terapéutico , Farmacorresistencia Bacteriana , Mycobacterium tuberculosis/efectos de los fármacos , Técnicas de Amplificación de Ácido Nucleico , Rifampin/uso terapéutico , Tuberculosis/diagnóstico , Adulto , Sesgo , Reacciones Falso Negativas , Reacciones Falso Positivas , Humanos , Mycobacterium tuberculosis/aislamiento & purificación , Técnicas de Amplificación de Ácido Nucleico/métodos , Técnicas de Amplificación de Ácido Nucleico/estadística & datos numéricos , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad , Tuberculosis/líquido cefalorraquídeo , Tuberculosis/tratamiento farmacológico , Tuberculosis Ganglionar/líquido cefalorraquídeo , Tuberculosis Ganglionar/diagnóstico , Tuberculosis Ganglionar/tratamiento farmacológico , Tuberculosis Meníngea/líquido cefalorraquídeo , Tuberculosis Meníngea/diagnóstico , Tuberculosis Meníngea/tratamiento farmacológico , Tuberculosis Resistente a Múltiples Medicamentos/líquido cefalorraquídeo , Tuberculosis Resistente a Múltiples Medicamentos/diagnóstico , Tuberculosis Resistente a Múltiples Medicamentos/tratamiento farmacológico , Tuberculosis Pleural/líquido cefalorraquídeo , Tuberculosis Pleural/diagnóstico , Tuberculosis Pleural/tratamiento farmacológico
4.
JAMA Intern Med ; 181(3): 353-360, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33449069

RESUMEN

Importance: Nasopharyngeal swab nucleic acid amplification testing (NAAT) is the noninvasive criterion standard for diagnosis of coronavirus disease 2019 (COVID-19). However, it requires trained personnel, limiting its availability. Saliva NAAT represents an attractive alternative, but its diagnostic performance is unclear. Objective: To assess the diagnostic accuracy of saliva NAAT for COVID-19. Data Sources: In this systematic review, a search of the MEDLINE and medRxiv databases was conducted on August 29, 2020, to find studies of diagnostic test accuracy. The final meta-analysis was performed on November 17, 2020. Study Selection: Studies needed to provide enough data to measure salivary NAAT sensitivity and specificity compared with imperfect nasopharyngeal swab NAAT as a reference test. An imperfect reference test does not perfectly reflect the truth (ie, it can give false results). Studies were excluded if the sample contained fewer than 20 participants or was neither random nor consecutive. The Quality Assessment of Diagnostic Accuracy Studies 2 tool was used to assess the risk of bias. Data Extraction and Synthesis: Preferred Reporting Items for Systematic Reviews and Meta-analyses reporting guideline was followed for the systematic review, with multiple authors involved at each stage of the review. To account for the imperfect reference test sensitivity, we used a bayesian latent class bivariate model for the meta-analysis. Main Outcomes and Measures: The primary outcome was pooled sensitivity and specificity. Two secondary analyses were performed: one restricted to peer-reviewed studies, and a post hoc analysis limited to ambulatory settings. Results: The search strategy yielded 385 references, and 16 unique studies were identified for quantitative synthesis. Eight peer-reviewed studies and 8 preprints were included in the meta-analyses (5922 unique patients). There was significant variability in patient selection, study design, and stage of illness at which patients were enrolled. Fifteen studies included ambulatory patients, and 9 exclusively enrolled from an outpatient population with mild or no symptoms. In the primary analysis, the saliva NAAT pooled sensitivity was 83.2% (95% credible interval [CrI], 74.7%-91.4%) and the pooled specificity was 99.2% (95% CrI, 98.2%-99.8%). The nasopharyngeal swab NAAT had a sensitivity of 84.8% (95% CrI, 76.8%-92.4%) and a specificity of 98.9% (95% CrI, 97.4%-99.8%). Results were similar in secondary analyses. Conclusions and Relevance: These results suggest that saliva NAAT diagnostic accuracy is similar to that of nasopharyngeal swab NAAT, especially in the ambulatory setting. These findings support larger-scale research on the use of saliva NAAT as an alternative to nasopharyngeal swabs.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Saliva/virología , COVID-19/virología , Humanos , Sensibilidad y Especificidad