Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39093119

RESUMEN

To improve the portability of magnets in gyrotron devices, we designed a compact Bitter-type magnet with power consumption optimization theory. This magnet operates at room temperature in a small volume. The theory revises existing electromagnetic theory for non-uniform structural Bitter-type magnets and achieves the lowest energy consumption through iterative optimization. To extend the magnetic field homogeneity region, the ferromagnetic material armature is applied to the Bitter-type system without additional power consumption. Unlike previous manual designs, the proposed Bitter-type magnets can obtain optimal parameters with a significant reduction in computing time. Through the introduction of correction factors, we improve accuracy through multiple verifications of simulations and experiments. On this basis, a room-temperature Bitter-type magnet system for Ka-band fundamental mode gyrotron amplifiers is designed. Its maximum magnetic field strength is 1.1 T, and the length of the homogeneity region is 300 mm. Through optimization, its energy consumption is only 27.5 kW.

2.
Rev Sci Instrum ; 94(10)2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37823769

RESUMEN

Backward wave oscillation seriously degrades the stability of gyrotron travelling-wave tubes (gyro-TWTs), especially during high average/continuous wave operation. To solve this problem, a selective mode suppression structure (SMSS) based on the mode coupling principle is proposed and applied in the nonlinear beam-wave interaction region to suppress the parasitic TE11 mode. It is capable of obtaining a high power and improving the tube stability. Simulation results demonstrate that the SMSS can raise the starting current from 10 to 18 A and the starting pitch factor from 1.2 to 1.6. Based on this proposed circuit, a Ka-band TE01 mode gyro-TWT was designed, and the particle-in-cell simulation shows that it can achieve a saturated output power of over 150 kW from 29.7 to 31.7 GHz with a velocity spread of 2.2%. For verification, a SMSS is manufactured and cold tested. The measurement of S-parameters reveals that it can effectively suppress the parasitic TE11 mode.

3.
Rev Sci Instrum ; 88(7): 074701, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28764507

RESUMEN

A generic approach to excite TEn0 (n ≥ 1) modes in a rectangular waveguide for confocal gyro-devices is proposed. The exciter consists of a 3 dB H-plane power divider (n ≥ 3) and a mode-converting section. The injection power is split into two in-phase signals with equal amplitudes which simultaneously excite the secondary waveguide via two sets of multiple slots. Both the position and width of the slot are symmetrically distributed with respect to the center line for each set of slots. The slot width complies with a geometry sequence, with adjacent slots being spaced a quarter wavelength apart to cancel the backward wave out. A TE40 mode exciter at 100 GHz is numerically simulated and optimized, achieving a 1 dB and a 3 dB transmission bandwidth of 18.2 and 21 GHz, respectively. The prototype is fabricated and measured. The cold test is carried out utilizing two identical back-to-back connected mode exciters, and the measured performances are in good agreement with the numerical simulation results when taking into account the wall loss and assembly tolerance.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA