Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Anal Bioanal Chem ; 415(5): 809-821, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36507958

RESUMEN

The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-µg folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-α-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC-MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates.


Asunto(s)
Ácido Fólico , Espectrometría de Masas en Tándem , Humanos , Ácido Fólico/análisis , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Estándares de Referencia , Ácido Ascórbico
2.
Clin Chem Lab Med ; 61(1): 78-85, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36279170

RESUMEN

OBJECTIVES: Vitamin D-binding protein (VDBP), a serum transport protein for 25-hydroxyvitamin D [25(OH)D], has three common proteoforms which have co-localized amino acid variations and glycosylation. A monoclonal immunoassay was found to differentially detect VDBP proteoforms and methods using liquid chromatography-tandem mass spectrometry (LC-MS/MS) might be able to overcome this limitation. Previously developed multiple reaction monitoring LC-MS/MS methods for total VDBP quantification represent an opportunity to probe the potential effects of proteoforms on proteolysis, instrument response and quantification accuracy. METHODS: VDBP was purified from homozygous human donors and quantified using proteolysis or acid hydrolysis and LC-MS/MS. An interlaboratory comparison was performed using pooled human plasma [Standard Reference Material® 1950 (SRM 1950) Metabolites in Frozen Human Plasma] and analyses with different LC-MS/MS methods in two laboratories. RESULTS: Several shared peptides from purified proteoforms were found to give reproducible concentrations [≤2.7% coefficient of variation (CV)] and linear instrument responses (R2≥0.9971) when added to human serum. Total VDBP concentrations from proteolysis or amino acid analysis (AAA) of purified proteoforms had ≤1.92% CV. SRM 1950, containing multiple proteoforms, quantified in two laboratories resulted in total VDBP concentrations with 7.05% CV. CONCLUSIONS: VDBP proteoforms were not found to cause bias during quantification by LC-MS/MS, thus demonstrating that a family of proteins can be accurately quantified using shared peptides. A reference value was assigned for total VDBP in SRM 1950, which may be used to standardize methods and improve the accuracy of VDBP quantification in research and clinical samples.


Asunto(s)
Espectrometría de Masas en Tándem , Proteína de Unión a Vitamina D , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Proteolisis , Vitamina D , Proteínas Sanguíneas/metabolismo , Aminoácidos/metabolismo
3.
Clin Mass Spectrom ; 16: 11-17, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34820515

RESUMEN

Vitamin D plays a vital role in successful pregnancy outcomes for both the mother and fetus. Vitamin D is bound to vitamin D binding protein (VDBP) in blood and is carried to the liver, kidneys and other target tissues. Accurate measurements of the clinically measured metabolite of vitamin D, 25-hydroxyvitamin D [25(OH)D], depend on complete removal from the binding protein. It has been found that VDBP concentrations increase in maternal serum during pregnancy, obfuscating the accuracy of 25(OH)D concentration measurements in pregnant women. Additionally, measurements of VDBP concentrations during pregnancy have been performed using immunoassays, which suffer from variations due to differences in antibody epitopes, making clinical comparisons difficult. Quantification of VDBP is also of interest because changes in VDBP expression levels may indicate negative outcomes during pregnancy, such as preterm delivery and restricted fetal growth. To address the need for accurate measurement of VDBP during pregnancy, a method using liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) was developed to quantify VDBP using isotopically labeled peptides as internal standards. This method was used to quantify VDBP in Standard Reference Material® (SRM) 1949 Frozen Human Prenatal Serum, which was prepared from separate serum pools of women who were not pregnant and women during each trimester of pregnancy. VDBP concentrations were found to be lowest in the serum pool from non-pregnant women and increased in each trimester. These data had good repeatability and were found to be suitable for reference value assignment of VDBP in SRM 1949.

4.
Anal Bioanal Chem ; 410(9): 2321-2329, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29435636

RESUMEN

Dietary fatty acids can be both beneficial and detrimental to human health depending on the degree and type of saturation. Healthcare providers and research scientists monitor the fatty acid content of human plasma and serum as an indicator of health status and diet. In addition, both the Centers for Disease Control & Prevention (CDC) and the National Institutes of Health - Office of Dietary Supplements are interested in circulating fatty acids (FAs) because they may be predictive of coronary heart disease. The National Institute of Standards and Technology (NIST) provides a wide variety of reference materials (RMs) and Standard Reference Materials® (SRM®s) including blood, serum, plasma, and urine with values assigned for analytes of clinical interest. NIST SRM 2378 Fatty Acids in Frozen Human Serum was introduced in 2015 to help validate methods used for the analysis of FAs in serum, and consists of three different pools of serum acquired from (1) healthy donors who had taken fish oil dietary supplements (at least 1000 mg per day) for at least one month (level 1 material), (2) healthy donors who had taken flaxseed oil dietary supplements (at least 1000 mg per day) for at least one month (level 2 material), and (3) healthy donors eating "normal" diets who had not taken dietary supplements containing fish or plant oils (level 3 material). The use of dietary supplements by donors provided SRMs with natural endogenous ranges of FAs at concentrations observed in human populations. Results from analyses using two methods at NIST, including one involving a novel microwave-assisted acid hydrolysis procedure, and one at the CDC are presented here. These results and their respective uncertainties were combined to yield certified values with expanded uncertainties for 12 FAs and reference values with expanded uncertainties for an additional 18 FAs.


Asunto(s)
Cromatografía de Gases/métodos , Suplementos Dietéticos , Ácidos Grasos/sangre , Ionización de Llama/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Conservación de la Sangre , Cromatografía de Gases/normas , Criopreservación , Suplementos Dietéticos/análisis , Ácidos Grasos/normas , Ácidos Grasos Insaturados/sangre , Ácidos Grasos Insaturados/normas , Aceites de Pescado/administración & dosificación , Aceites de Pescado/sangre , Ionización de Llama/normas , Congelación , Cromatografía de Gases y Espectrometría de Masas/normas , Humanos , Aceites de Plantas/administración & dosificación , Aceites de Plantas/análisis , Estándares de Referencia
5.
Anal Bioanal Chem ; 410(4): 1265-1278, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29222652

RESUMEN

A Standard Reference Material (SRM) of seaweed, SRM 3232 Kelp Powder (Thallus laminariae) has been developed to support food and dietary supplement measurements in compliance with the Food Safety Modernization Act (FSMA) and the Dietary Supplement Health and Education Act of 1994 (DSHEA). The material was characterized for nutritional minerals, arsenic species, isomers of vitamin K1, proximates, and toxic elements. Kelp is a rich source of vitamins and minerals, and it is an excellent source of dietary iodine. Kelp also contains a large amount of arsenic, which is toxic as inorganic species but much less so as organic species. To capture the dietary profile of kelp, certified values were issued for As, Ca, Cd, Cr, Cu, Fe, Hg, I, K, Mg, Mn, Mo, Na, Pb, and Zn. Reference values for proximates were assigned. For the first time, a certified value for iodine, reference values for isomers of vitamin K1, and reference values for arsenic species including arsenosugars were assigned in a seaweed. SRM 3232 fills a gap in Certified Reference Materials (CRMs) needed for quality assurance and method validation in the compositional measurements of kelp and similar seaweeds used as food and as dietary supplements. Graphical Absract Arsenic species and isomers of vitamin K1 were determined in the development of SRM 3232 Kelp Powder (Thallus laminariae).


Asunto(s)
Kelp/química , Polvos , Cromatografía Liquida , Estándares de Referencia , Espectrometría de Masas en Tándem
6.
Anal Chem ; 89(19): 10461-10467, 2017 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-28930436

RESUMEN

A new tobacco filler Standard Reference Material (SRM) has been issued by the National Institute of Standards and Technology (NIST) in September 2016 with certified and reference mass fraction values for nicotine, N-nitrosonornicotine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone, and volatiles. The constituents have been determined by multiple analytical methods with measurements at NIST and at the Centers for Disease Control and Prevention, and with confirmatory measurements by commercial laboratories. This effort highlights the development of the first SRM for reduced nicotine and reduced tobacco-specific nitrosamines with certified values for composition.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas/métodos , Espectrometría de Masas en Tándem/métodos , Productos de Tabaco/análisis , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Líquida de Alta Presión/normas , Congelación , Cromatografía de Gases y Espectrometría de Masas/normas , Nicotina/análisis , Nicotina/normas , Nitrosaminas/análisis , Nitrosaminas/normas , Transición de Fase , Estándares de Referencia , Espectrometría de Masas en Tándem/normas , Productos de Tabaco/normas , Compuestos Orgánicos Volátiles/análisis , Compuestos Orgánicos Volátiles/normas
7.
J AOAC Int ; 100(5): 1294-1303, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28917261

RESUMEN

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements and the Vitamin D Standardization Program, has recently issued a new serum-matrix Standard Reference Material (SRM): 2973 Vitamin D Metabolites in Frozen Human Serum (High Level). SRM 2973 was designed to provide a serum material with a total 25-hydroxyvitamin D [25(OH)D] concentration near 100 nmol/L to complement the existing serum-based SRMs with values assigned for total 25(OH)D between 20 and 80 nmol/L. Values were assigned for 25-hydroxyvitamin D2 [25(OH)D2], 25-hydroxyvitamin D3 [25(OH)D3], 3-epi-25(OH)D3, and total 25(OH)D [the sum of 25(OH)D2 + 25(OH)D3] using the NIST isotope dilution LC with tandem MS (MS/MS) reference measurement procedure (RMP) and related methods. SRM 2973 has a certified value of 98.4 ± 2.1 nmol/L for 25(OH)D3 and reference values of 1.59 ± 0.05 nmol/L for 25(OH)D2 and 5.23 ± 0.20 nmol/L for 3-epi-25(OH)D3. In addition, a candidate RMP for 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3] based on LC-MS/MS was used to assign values to SRM 2973 and the existing SRM 972a Vitamin D Metabolites in Frozen Human Serum. Reference values for 24R,25(OH)2D3 were assigned to SRM 2973 (7.51 ± 0.26 nmol/L) and the four levels of SRM 972a: Level 1 (6.38 ± 0.23 nmol/L), Level 2 (3.39 ± 0.12 nmol/L), Level 3 (3.88 ± 0.013 nmol/L), and Level 4 (6.32 ± 0.22 nmol/L). The development of SRM 2973 [with a higher concentration of 25(OH)D3] and the addition of values for 24R,25(OH)2D3 assigned to both SRM 972a and SRM 2973 provide laboratories involved in vitamin D measurements with improved QA tools.


Asunto(s)
25-Hidroxivitamina D 2/sangre , Análisis Químico de la Sangre/normas , Calcifediol/sangre , Humanos , Espectrometría de Masas en Tándem/normas , Estados Unidos , Vitamina D
8.
Anal Chem ; 89(9): 4907-4913, 2017 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-28375002

RESUMEN

The National Institute of Standards and Technology (NIST) has developed Standard Reference Material (SRM) 972a Vitamin D Metabolites in Frozen Human Serum as a replacement for SRM 972, which is no longer available. SRM 972a was developed in collaboration with the National Institutes of Health's Office of Dietary Supplements. In contrast to the previous reference material, three of the four levels of SRM 972a are composed of unmodified human serum. This SRM has certified and reference values for the following 25-hydroxyvitamin D [25(OH)D] species: 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3. The value assignment and certification process included three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). The value assignment methods employed have been modified from those utilized for the previous SRM, and all three approaches now incorporate chromatographic resolution of the stereoisomers, 25(OH)D3 and 3-epi-25(OH)D3.


Asunto(s)
25-Hidroxivitamina D 2/sangre , Calcifediol/sangre , Cromatografía Liquida/normas , Espectrometría de Masas/normas , 25-Hidroxivitamina D 2/normas , Calcifediol/química , Calcifediol/normas , Humanos , Estándares de Referencia , Valores de Referencia , Estereoisomerismo , Estados Unidos , United States Government Agencies
9.
Anal Bioanal Chem ; 409(4): 949-960, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27832301

RESUMEN

Two independent analytical approaches, based on liquid chromatography with absorbance detection and liquid chromatography with mass spectrometric detection, have been developed for determination of isoflavones in soy materials. These two methods yield comparable results for a variety of soy-based foods and dietary supplements. Four Standard Reference Materials (SRMs) have been produced by the National Institute of Standards and Technology to assist the food and dietary supplement community in method validation and have been assigned values for isoflavone content using both methods. These SRMs include SRM 3234 Soy Flour, SRM 3236 Soy Protein Isolate, SRM 3237 Soy Protein Concentrate, and SRM 3238 Soy-Containing Solid Oral Dosage Form. A fifth material, SRM 3235 Soy Milk, was evaluated using the methods and found to be inhomogeneous for isoflavones and unsuitable for value assignment. Graphical Abstract Separation of six isoflavone aglycones and glycosides found in Standard Reference Material (SRM) 3236 Soy Protein Isolate.


Asunto(s)
Cromatografía Liquida/métodos , Isoflavonas/análisis , Alimentos de Soja/análisis , Espectrofotometría Ultravioleta/métodos , Isótopos , Espectrometría de Masas , Espectroscopía de Protones por Resonancia Magnética , Estándares de Referencia
10.
Bioenergy Res ; 9(1): 303-314, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27019676

RESUMEN

Biomass compositional methods are used to compare different lignocellulosic feedstocks, to measure component balances around unit operations and to determine process yields and therefore the economic viability of biomass-to-biofuel processes. Four biomass reference materials (RMs NIST 8491-8494) were prepared and characterized, via an interlaboratory comparison exercise in the early 1990s to evaluate biomass summative compositional methods, analysts, and laboratories. Having common, uniform, and stable biomass reference materials gives the opportunity to assess compositional data compared to other analysts, to other labs, and to a known compositional value. The expiration date for the original characterization of these RMs was reached and an effort to assess their stability and recharacterize the reference values for the remaining material using more current methods of analysis was initiated. We sent samples of the four biomass RMs to 11 academic, industrial, and government laboratories, familiar with sulfuric acid compositional methods, for recharacterization of the component reference values. In this work, we have used an expanded suite of analytical methods that are more appropriate for herbaceous feedstocks, to recharacterize the RMs' compositions. We report the median values and the expanded uncertainty values for the four RMs on a dry-mass, whole-biomass basis. The original characterization data has been recalculated using median statistics to facilitate comparisons with this data. We found improved total component closures for three out of the four RMs compared to the original characterization, and the total component closures were near 100 %, which suggests that most components were accurately measured and little double counting occurred. The major components were not statistically different in the recharacterization which suggests that the biomass materials are stable during storage and that additional components, not seen in the original characterization, were quantified here.

11.
Anal Chem ; 85(24): 11732-8, 2013 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-24187941

RESUMEN

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health (NIH), has developed a Standard Reference Material (SRM) to support technology development in metabolomics research. SRM 1950 Metabolites in Human Plasma is intended to have metabolite concentrations that are representative of those found in adult human plasma. The plasma used in the preparation of SRM 1950 was collected from both male and female donors, and donor ethnicity targets were selected based upon the ethnic makeup of the U.S. population. Metabolomics research is diverse in terms of both instrumentation and scientific goals. This SRM was designed to apply broadly to the field, not toward specific applications. Therefore, concentrations of approximately 100 analytes, including amino acids, fatty acids, trace elements, vitamins, hormones, selenoproteins, clinical markers, and perfluorinated compounds (PFCs), were determined. Value assignment measurements were performed by NIST and the Centers for Disease Control and Prevention (CDC). SRM 1950 is the first reference material developed specifically for metabolomics research.


Asunto(s)
Análisis Químico de la Sangre/normas , Metabolómica/normas , Adulto , Aminoácidos/sangre , Biomarcadores/sangre , Carotenoides/sangre , Ácidos Grasos/sangre , Femenino , Humanos , Masculino , National Institutes of Health (U.S.) , Estándares de Referencia , Estados Unidos , Vitaminas/sangre
12.
Anal Bioanal Chem ; 405(13): 4539-48, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23529413

RESUMEN

The vitamin C concentrations in three food-matrix Standard Reference Materials (SRMs) from the National Institute of Standards and Technology (NIST) have been determined by liquid chromatography (LC) with absorbance detection. These materials (SRM 1549a Whole Milk Powder, SRM 1849a Infant/Adult Nutritional Formula, and SRM 3233 Fortified Breakfast Cereal) have been characterized to support analytical measurements made by food processors that are required to provide information about their products' vitamin C content on the labels of products distributed in the United States. The SRMs are primarily intended for use in validating analytical methods for the determination of selected vitamins, elements, fatty acids, and other nutrients in these materials and in similar matrixes. They can also be used for quality assurance in the characterization of test samples or in-house control materials, and for establishing measurement traceability. Within-day precision of the LC method used to measure vitamin C in the food-matrix SRMs characterized in this study ranged from 2.7% to 6.5%.


Asunto(s)
Ácido Ascórbico/normas , Cromatografía Liquida/normas , Suplementos Dietéticos/normas , Alimentos Formulados/normas , Ácido Ascórbico/análisis , Suplementos Dietéticos/análisis , Alimentos Formulados/análisis , Humanos , Lactante , Control de Calidad , Estándares de Referencia , Valores de Referencia , Reproducibilidad de los Resultados
13.
Anal Bioanal Chem ; 405(13): 4531-8, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23371533

RESUMEN

As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed Standard Reference Material (SRM) 3274 Botanical Oils Containing Omega-3 and Omega-6 Fatty Acids and SRM 3275 Omega-3 and Omega-6 Fatty Acids in Fish Oil. SRM 3274 consists of one ampoule of each of four seed oils (3274-1 Borage (Borago officinalis), 3274-2 Evening Primrose (Oenothera biennis), 3274-3 Flax (Linium usitatissimum), and 3274-4 Perilla (Perilla frutescens)), and SRM 3275 consists of two ampoules of each of three fish oils (3275-1 a concentrate high in docosahexaenoic acid, 3275-2 an anchovy oil high in docosahexaenoic acid and eicosapentaenoic acid, and 3275-3 a concentrate containing 60% long-chain omega-3 fatty acids). Each oil has certified and reference mass fraction values for up to 20 fatty acids. The fatty acid mass fraction values are based on results from analyses using gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS). These SRMs will complement other reference materials currently available with mass fractions for similar analytes and are part of a series of SRMs being developed for dietary supplements.


Asunto(s)
Suplementos Dietéticos/normas , Ácidos Docosahexaenoicos/normas , Ácido Eicosapentaenoico/normas , Aceites de Pescado/normas , Aceites de Plantas/normas , Cromatografía de Gases , Suplementos Dietéticos/análisis , Ácidos Docosahexaenoicos/aislamiento & purificación , Ácido Eicosapentaenoico/aislamiento & purificación , Aceites de Pescado/química , Ionización de Llama , Humanos , Aceites de Plantas/química , Estándares de Referencia , Valores de Referencia
14.
J AOAC Int ; 96(6): 1281-7, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24645505

RESUMEN

Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.


Asunto(s)
Química Farmacéutica/normas , Suplementos Dietéticos/análisis , Suplementos Dietéticos/normas , Vitaminas/análisis , Carotenoides/análisis , Química Farmacéutica/métodos , Control de Calidad , Estándares de Referencia , Reproducibilidad de los Resultados , Comprimidos , Estados Unidos , Vitaminas/química
15.
J Agric Food Chem ; 60(27): 6794-8, 2012 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-22686411

RESUMEN

Standard Reference Material (SRM) 3278 Tocopherols in Edible Oils has been issued for use as a quality assurance tool in the measurement of tocopherols. Like other natural-matrix SRMs, this material can be used in method validation or in assignment of tocopherol values to in-house quality control materials. Because most edible oils contain one predominant tocopherol isoform, the SRM is a blend of sunflower, soy, canola, and safflower oils to provide roughly comparable chromatographic peak heights of the two main tocopherols, γ and α, with smaller amounts of δ and ß. The four tocopherol isoforms were determined by three independent liquid chromatography methods with absorbance and fluorescence detection. Various chromatographic and detection modes are used for assignment of certified values because biases inherent to one method should not be present in the other, and the existence of bias can therefore be identified.


Asunto(s)
Cromatografía Liquida/normas , Aceites de Plantas/normas , Tocoferoles/normas , Cromatografía Liquida/métodos , Aceites de Plantas/análisis , Control de Calidad , Estándares de Referencia , Tocoferoles/análisis
16.
Anal Bioanal Chem ; 402(2): 749-62, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22015475

RESUMEN

Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total ß-cryptoxanthin, total ß-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-ß-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.


Asunto(s)
Carotenoides/sangre , Colesterol/sangre , Vitaminas/sangre , Carotenoides/química , Colesterol/química , Cromatografía Liquida , Humanos , Estructura Molecular , Estándares de Referencia , Vitaminas/química
17.
Anal Chem ; 84(2): 956-62, 2012 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-22141317

RESUMEN

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health's Office of Dietary Supplements (NIH-ODS), has developed a Standard Reference Material (SRM) for the determination of 25-hydroxyvitamin D [25(OH)D] in serum. SRM 972 Vitamin D in Human Serum consists of four serum pools with different levels of vitamin D metabolites and has certified and reference values for 25(OH)D(2), 25(OH)D(3), and 3-epi-25(OH)D(3). Value assignment of this SRM was accomplished using a combination of three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). Chromatographic resolution of the 3-epimer of 25(OH)D(3) proved to be essential for accurate determination of the metabolites.


Asunto(s)
Vitamina D/análogos & derivados , Cromatografía Liquida , Humanos , Espectrometría de Masas , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Vitamina D/análisis , Vitamina D/sangre , Vitamina D/normas
18.
J AOAC Int ; 94(3): 815-22, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21797009

RESUMEN

The concentrations of selected fat-soluble vitamins and carotenoids in Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets have been determined by two independent LC methods, with measurements performed by the National Institute of Standards and Technology (NIST). This SRM has been prepared as part of a collaborative effort between NIST and the National Institutes of Health Office of Dietary Supplements. The SRM is also intended to support the Dietary Supplement Ingredient Database that is being established by the U.S. Department of Agriculture. The methods used at NIST to determine the concentration levels of vitamins A and E, and beta-carotene in the SRM used RPLC with absorbance detection. The relative precision of these methods ranged from 2 to 8% for the analytes measured. SRM 3280 is primarily intended for use in validating analytical methods for the determination of selected vitamins, carotenoids, and elements in multivitamin/multielement tablets and similar matrixes.


Asunto(s)
Carotenoides/química , Cromatografía Liquida/métodos , Suplementos Dietéticos/análisis , Grasas/química , Vitaminas/química , Absorciometría de Fotón , Suplementos Dietéticos/normas , Estándares de Referencia , Sensibilidad y Especificidad , Comprimidos/química
19.
J Agric Food Chem ; 59(13): 7246-52, 2011 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-21688777

RESUMEN

The National Institute of Standards and Technology (NIST) has been working with the National Institutes of Health Office of Dietary Supplements to produce Standard Reference Materials (SRMs) of interest to analysts of dietary supplements. Some of these SRMs are traditional foods including SRM 3281 Cranberry (Fruit), SRM 3282 Low-Calorie Cranberry Juice Cocktail, and SRM 3287 Blueberry (Fruit), which have been characterized for nine nutritional elements and sugars. The blueberries have also been characterized for proximates, two water-soluble vitamins, and amino acids. These new materials are intended for use in method development and validation as well as for quality assurance and traceability in the assignment of values to in-house control materials. Foods can be difficult to analyze because of matrix effects. With the addition of these three new SRMs, it is now possible to more closely match controls to matrices and analyte levels for fruit and vegetable test samples. Several nutritional elements in these three SRMs are present at lower levels than in other food-matrix SRMs.


Asunto(s)
Arándanos Azules (Planta)/química , Frutas/química , Vaccinium macrocarpon/química , Suplementos Dietéticos/análisis , Etiquetado de Alimentos/legislación & jurisprudencia , National Institutes of Health (U.S.) , Valor Nutritivo , Control de Calidad , Estándares de Referencia , Estados Unidos
20.
J AOAC Int ; 93(4): 1262-74, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20922961

RESUMEN

Standard Reference Material (SRM) 1849 Infant/Adult Nutritional Formula has been issued by the National Institute of Standards and Technology (NIST) as a replacement for SRM 1846 Infant Formula, issued in 1996. Extraction characteristics of SRM 1846 have changed over time, as have NIST's analytical capabilities. While certified mass fraction values were provided for five constituents in SRM 1846 (four vitamins plus iodine), certified mass fraction values for 43 constituents are provided in SRM 1849 (fatty acids, elements, and vitamins) and reference mass fraction values are provided for an additional 43 constituents including amino acids and nucleotides, making it the most extensively characterized food-matrix SRM available from NIST.


Asunto(s)
Fórmulas Infantiles/normas , Aminoácidos/análisis , Conducta Cooperativa , Ácidos Grasos/análisis , Humanos , Lactante , Fórmulas Infantiles/química , Estándares de Referencia , Vitaminas/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA