PURPOSE: Neo-sinus flow stasis has ben correlated with transcatheter heart valve (THV) thrombosis severity and occurrence. Standard benchtop flow field quantification techniques require optical access or modified prosthesis models that may not reflect the true nature of the original valve. En face and fluoroscopic videodensitometry enable visualization of washout in regions otherwise unviewable. METHODS: This study compares two in vitro methods of assessing flow stasis in scenarios with insufficient optical access for traditional techniques such as particle image velocimetry (PIV). A series of seven paired experiments were conducted using a previously described laser-enhanced video densitometry (LEVD) and fluoroscopic video densitometry (FVD). Both sets of experiments were analyzed to calculate washout time as a measure of flow stasis. A novel flow stasis measure termed contrast attenuation ratio (CAR) is proposed as a viable single measure of flow stasis obtainable from only a small number of cardiac cycles of in vitro or in vivo fluoroscopic data. Retrospective fluoroscopic datasets (n = 72) were analyzed to assess the feasibility of obtaining this metric from routine clinical practice and its ability to stratify results. RESULTS: Neo-sinus flow stasis calculated from in vitro fluoroscopy was well correlated with LEVD (r2 = 0.77, p = 0.009). The newly proposed CAR metric showed good agreement with the commonly used "washout time" measure of flow stasis (r2 = 0.91, p < 0.001) while allowing for assessment with incomplete or truncated data. As a proof of concept, CAR was measured in 72 consecutive retrospective fluoroscopic datasets. CAR averaged 10.6 ± 4.6% with a range of 1.5-20.3% in these patients. CONCLUSIONS: This study demonstrates two in vitro methods that can be used to assess relative flow stasis in otherwise optically inaccessible regions surrounding cardiac or vascular implants. In addition, the fluoroscopic benchtop technique was used to validate a metric that allows for extension to routine clinical fluoroscopy. This contrast attenuation ratio (CAR) metric was found to be both accurate and clinically obtainable, and potentially offers a new method for valve thrombosis risk stratification.
RESUMEN
Extracorporeal membrane oxygenation (ECMO) is a high-risk and low-volume life support with increasing clinical study. However, heterogenous outcome definitions impede data assimilation into evidence to guide practice. The Academic Research Consortium (ARC), an international collaborative forum committed to facilitating the creation of stakeholder-driven consensus nomenclature and outcomes for clinical trials of medical devices, supported the ECMO Core Elements Needed for Trials Regulation And quality of Life (ECMO-CENTRAL) ARC. The ECMO-CENTRAL ARC was assembled to develop definitions of paediatric ECMO adverse events for use in clinical trials and regulatory device evaluation. An initial candidate list of ECMO adverse events derived from the mechanical circulatory support ARC was supplemented with a review of ECMO-relevant adverse event definitions collated from literature published between Jan 1, 1988, and Feb 20, 2023. Distinct teams of international topic experts drafted separate adverse event definitions that were harmonised to existing literature when appropriate. Draft definitions were revised for paediatric ECMO relevance with input from patients, families, and an international expert panel of trialists, clinicians, statisticians, biomedical engineers, device developers, and regulatory agencies. ECMO-CENTRAL ARC was revised and disseminated across research societies and professional organisations. Up to three rounds of internet-based anonymous surveys were planned as a modified Delphi process. The expert panel defined 13 adverse event definitions: neurological, bleeding, device malfunction, acute kidney injury, haemolysis, infection, vascular access-associated injury, non-CNS thrombosis, hepatic dysfunction, right heart failure, left ventricular overload, lactic acidaemia, and hypoxaemia. Definitional structure varied. Among 165 expert panel members, 114 were eligible to vote and 111 voted. Consensus was achieved for all proposed definitions. Agreement ranged from 82% to 95%. ECMO-CENTRAL ARC paired rigorous development with methodical stakeholder involvement and dissemination to define paediatric ECMO adverse events. These definitions will facilitate new research and the assimilation of data across clinical trials and ECMO device evaluation in children.
Asunto(s)
Técnica Delphi , Oxigenación por Membrana Extracorpórea , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Niño , ConsensoRESUMEN
PURPOSE: Patient-specific simulations of transcatheter aortic valve (TAV) using computational fluid dynamics (CFD) often rely on assumptions regarding proximal and distal anatomy due to the limited availability of high-resolution imaging away from the TAV site and the primary research focus being near the TAV. However, the influence of these anatomical assumptions on computational efficiency and resulting flow characteristics remains uncertain. This study aimed to investigate the impact of different distal aortic arch anatomies-some of them commonly used in literature-on flow and hemodynamics in the vicinity of the TAV using large eddy simulations (LES). METHODS: Three aortic root anatomical configurations with four representative distal aortic arch types were considered in this study. The arch types included a 90-degree bend, an idealized distal aortic arch anatomy, a clipped version of the idealized distal aortic arch, and an anatomy extruded along the normal of segmented anatomical boundary. Hemodynamic parameters both instantaneous and time-averaged such as Wall Shear Stress (WSS), and Oscillatory Shear Index (OSI) were derived and compared from high-fidelity CFD data. RESULTS: While there were minor differences in flow and hemodynamics across the configurations examined, they were generally not significant within our region of interest i.e., the aortic root. The choice of extension type had a modest impact on TAV hemodynamics, especially in the vicinity of the TAV with variations observed in local flow patterns and parameters near the TAV. However, these differences were not substantial enough to cause significant deviations in the overall flow and hemodynamic characteristics. CONCLUSIONS: The results suggest that under the given configuration and boundary conditions, the type of outflow extension had a modest impact on hemodynamics proximal to the TAV. The findings contribute to a better understanding of flow dynamics in TAV configurations, providing insights for future studies in TAV-related experiments as well as numerical simulations. Additionally, they help mitigate the uncertainties associated with patient-specific geometries, offering increased flexibility in computational modeling.
Asunto(s)
Aorta Torácica , Válvula Aórtica , Hemodinámica , Modelos Cardiovasculares , Modelación Específica para el Paciente , Humanos , Aorta Torácica/anatomía & histología , Aorta Torácica/fisiología , Aorta Torácica/diagnóstico por imagen , Válvula Aórtica/anatomía & histología , Válvula Aórtica/diagnóstico por imagen , Hidrodinámica , Reemplazo de la Válvula Aórtica Transcatéter , Simulación por Computador , Velocidad del Flujo Sanguíneo , Flujo Sanguíneo Regional , Estrés MecánicoRESUMEN
Patient-specific aortic geometry and its influence on the flow in the vicinity of Transcatheter Aortic Valve (TAV) has been highlighted in numerous studies using both in silico and in vitro experiments. However, there has not yet been a detailed Particle Image Velocimetry (PIV) experiment conducted to quantify the relationship between the geometry, flow downstream of TAV, and the flow in the sinus and the neo-sinus. We tested six different patient-specific aorta models with a 26-mm SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA, USA) in a left heart simulator with coronary flow. Velocities in all three cusps and circulation downstream of TAV were computed to evaluate the influence of the ascending aorta curvature on the flow field. The in vitro analysis showed that the patient-specific aortic curvature had positive correlation to the circulation in the ascending aorta (p = 0.036) and circulation had negative correlation to the particle washout time in the cusps (p = 0.011). These results showed that distinct vortical flow patterns in the ascending aorta as the main jet impinges on the aortic wall causes a recirculation region that facilitates the flow back into the sinus and the neo-sinus, thus reducing the risk of flow stagnation and washout time.
Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Velocidad del Flujo Sanguíneo , Aorta , Diseño de PrótesisRESUMEN
BACKGROUND: Leaflet thrombosis after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) may be caused by blood flow stagnation in the native and neosinus regions. To date, aortic leaflet laceration has been used to mitigate coronary obstruction following TAVR; however, its influence on the fluid mechanics of the native and neosinus regions is poorly understood. This in vitro study compared the flow velocities and flow patterns in the setting of SAVR vs TAVR with and without aortic leaflet lacerations. METHODS: Two valves, (23-mm Perimount and 26-mm SAPIEN 3; Edwards Lifesciences) were studied in a validated mock flow loop under physiologic conditions. Neosinus and native sinus fluid mechanics were quantified using particle image velocimetry in the left and noncoronary cusp, with an increasing number of aortic leaflets lacerated or removed. RESULTS: Across all conditions, SAVR had the highest average sinus and neosinus velocities, and this value was used as a reference to compare against the TAVR conditions. With an increasing number of leaflets lacerated or removed with TAVR, the average sinus and neosinus velocities increased from 25% to 70% of SAVR flow (100%). Diastolic velocities were substantially augmented by leaflet laceration. Also, the shorter frame of the SAVR led to higher flow velocities compared with the longer frame of the TAVR, even after complete leaflet removal. CONCLUSIONS: Leaflet laceration augmented TAVR native and neosinus flow fields, approaching that of SAVR. These findings may have potential clinical implications for the use of single or multiple leaflet lacerations to reduce leaflet thrombosis and thus potentially improve TAVR durability.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Laceraciones , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Laceraciones/complicaciones , Laceraciones/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Trombosis/etiología , Estenosis de la Válvula Aórtica/cirugía , Resultado del TratamientoRESUMEN
The authors report a closed-chest, transcatheter large-vessel connection (hepatic conduit to azygous vein) to reverse pulmonary arteriovenous malformations in a 10-year-old patient after Fontan for heterotaxy/interrupted inferior vena cava, with an increase in oxygen saturation from 78% to 96%. Computational fluid dynamics estimated a 14-fold increase in hepatic blood flow to the left pulmonary artery (from 1.3% to 14%). (Level of Difficulty: Advanced.).
RESUMEN
PURPOSE: Leaflet thrombosis is a potentially fatal complication after transcatheter aortic valve replacement (TAVR). Blood flow stagnation in the neo-sinus and aortic sinuses are associated with increased thrombus severity. Native aortic leaflet modification may be a potential strategy to improve the neo-sinus and aortic sinus fluid dynamics. However, limited data exist on the effect of leaflet geometry modification on the flow within the neo-sinus and aortic sinus regions. We evaluate the effect of aortic leaflet modification on the neo-sinus and aortic sinus flow stagnation after simulated TAVR. METHODS: Particle image velocimetry measurements were performed under nominal (5 LPM) and low (2.5 LPM) cardiac output conditions for an intact leaflet (control) case, and 3 modified leaflet geometries. Aortic leaflet geometry modification via leaflet splay was simulated with increasing splay geometry (leaflet splay distance: 5 mm-narrow, 10 mm-medium, and 20 mm-wide). RESULTS: Leaflet geometry modification influenced flow features throughout the cardiac cycle, at both cardiac outputs, and allowed for flow communication between the neo-sinus and aortic sinus regions compared to the control. In the aortic sinus, flow stagnation reduced by over 64% at 5LPM, and over 36% at 2.5LPM for all simulated modified leaflet geometries compared to the control. However, only the medium and wide splay geometries enabled a reduction in neo-sinus flow stagnation compared to the control case. CONCLUSIONS: These findings suggest that aortic leaflet geometry modification (of at least 10 mm leaflet splay distance) may reduce flow stasis and potentially decrease valve thrombosis risk.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Seno Aórtico , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Seno Aórtico/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Trombosis/etiología , Diseño de PrótesisRESUMEN
HIF1A is significantly upregulated in calcified human aortic valves (AVs). Furthermore, HIF1A inhibitor PX-478 was shown to inhibit AV calcification under static and disturbed flow conditions. Since elevated stretch is one of the major mechanical stimuli for AV calcification, we investigated the effect of PX-478 on AV calcification and collagen turnover under a pathophysiological cyclic stretch (15%) condition. Porcine aortic valve (PAV) leaflets were cyclically (1 Hz) stretched at 15% for 24 days in osteogenic medium with or without PX-478. In addition, PAV leaflets were cyclically stretched at a physiological (10%) and 15% for 3 days in regular medium to assess its effect of on HIF1A mRNA expression. It was found that 100 µM (high concentration) PX-478 could significantly inhibit PAV calcification under 15% stretch, whereas 50 µM (moderate concentration) PX-478 showed a modest inhibitory effect on PAV calcification. Nonetheless, 50 µM PX-478 significantly reduced PAV collagen turnover under 15% stretch. Surprisingly, it was observed that cyclic stretch (15% vs. 10%) did not have any significant effect on HIF1A mRNA expression in PAV leaflets. These results suggest that HIF1A inhibitor PX-478 may impart its anti-calcific and anti-matrix remodeling effect in a stretch-independent manner.
RESUMEN
OBJECTIVE: Implantation of a transcatheter valve-in-mitral annular calcification (ViMAC) has emerged as an alternative to traditional surgical mitral valve (MV) replacement. Previous studies evaluating ViMAC aggregated transseptal, transapical, and transatrial forms of the procedure, leaving uncertainty about each technique's advantages and disadvantages. Thus, we sought to evaluate clinical outcomes specifically for transatrial ViMAC from the largest multicenter registry to-date. METHODS: Patients with symptomatic MV dysfunction and severe MAC who underwent ViMAC were enrolled from 12 centers across the United States and Europe. Clinical characteristics, procedural details, and clinical outcomes were abstracted from the electronic record. The primary end point was all-cause mortality. RESULTS: We analyzed 126 patients who underwent ViMAC (median age 76 years [interquartile range {IQR}, 70-82 years], 28.6% female, median Society of Thoracic Surgeons score 6.8% [IQR, 4.0-11.4], and median follow-up 89 days [IQR, 16-383.5]). Sixty-one (48.4%) had isolated mitral stenosis, 25 (19.8%) had isolated mitral regurgitation (MR), and 40 (31.7%) had mixed MV disease. Technical success was achieved in 119 (94.4%) patients. Thirty (23.8%) patients underwent concurrent septal myectomy, and 8 (6.3%) patients experienced left ventricular outflow tract obstruction (7/8 did not undergo myectomy). Five (4.2%) patients of 118 with postprocedure echocardiograms had greater than mild paravalvular leak. Thirty-day and 1-year all-cause mortality occurred in 16 and 33 patients, respectively. In multivariable models, moderate or greater MR at baseline was associated with increased risk of 1-year mortality (hazard ratio, 2.31; 95% confidence interval, 1.07-4.99, P = .03). CONCLUSIONS: Transatrial ViMAC is safe and feasible in this selected, male-predominant cohort. Patients with significant MR may derive less benefit from ViMAC than patients with mitral stenosis only.
RESUMEN
Background: This study assessed the long-term hemodynamic functional performance of the new Inspiris Resilia aortic valve after accelerated wear testing (AWT). Methods: Three 21-mm and 23-mm Inspiris valves were used for the AWT procedure. After 1 billion cycles (equivalent to 25 years), the valves' hemodynamic performance was compared with that of the corresponding zero-cycled condition. Next, 1 AWT cycled valve of each valve size was selected at random for particle image velocimetry (PIV) and leaflet kinematic tests, and the data were compared with data for an uncycled Inspiris Resilia aortic valve of the same size. PIV was used to quantitatively evaluate flow fields downstream of the valve. Valves were tested according to International Standards Organization 5840-2:2015 protocols. Results: The 21-mm and 23-mm valves met the International Organization for Standardization (ISO) durability performance requirements to 1 billion cycles. The mean effective orifice areas for the 21-mm and 23-mm zero-cycled and 1 billion-cycled valves were 1.89 ± 0.02 cm2 and 1.94 ± 0.01 cm2, respectively (P < .05) and 2.3 ± 0.13 cm2 and 2.40 ± 0.11 cm2, respectively (P < .05). Flow characterization of the control valves and the study valves demonstrated similar flow characteristics. The velocity and shear stress fields were also similar in the control and study valves. Conclusions: The Inspiris Resilia aortic valve demonstrated very good durability and hemodynamic performance after an equivalent of 25 years of simulated in vitro accelerated wear. The study valves exceeded 1 billion cycles of simulated wear, 5 times longer than the standard requirement for a tissue valve as stipulated in ISO 5840-2:2015.
RESUMEN
Background: A clinical study comparing the hemodynamic outcomes of transcatheter mitral valve replacement (TMVR) with vs. without Laceration of the Anterior Mitral leaflet to Prevent Outflow Obstruction (LAMPOON) has never been designed nor conducted. Aims: To quantify the hemodynamic impact of LAMPOON in TMVR using patient-specific computational (in silico) models. Materials: Eight subjects from the LAMPOON investigational device exemption trial were included who had acceptable computed tomography (CT) data for analysis. All subjects were anticipated to be at prohibitive risk of left ventricular outflow tract (LVOT) obstruction from TMVR, and underwent successful LAMPOON immediately followed by TMVR. Using post-procedure CT scans, two 3D anatomical models were created for each subject: (1) TMVR with LAMPOON (performed procedure), and (2) TMVR without LAMPOON (virtual control). A validated computational fluid dynamics (CFD) paradigm was then used to simulate the hemodynamic outcomes for each condition. Results: LAMPOON exposed on average 2 ± 0.6 transcatheter valve cells (70 ± 20 mm2 total increase in outflow area) which provided an additional pathway for flow into the LVOT. As compared to TMVR without LAMPOON, TMVR with LAMPOON resulted in lower peak LVOT velocity, lower peak LVOT gradient, and higher peak LVOT effective orifice area by 0.4 ± 0.3 m/s (14 ± 7% improvement, p = 0.006), 7.6 ± 10.9 mmHg (31 ± 17% improvement, p = 0.01), and 0.2 ± 0.1 cm2 (17 ± 9% improvement, p = 0.002), respectively. Conclusion: This was the first study to permit a quantitative, patient-specific comparison of LVOT hemodynamics following TMVR with and without LAMPOON. The LAMPOON procedure achieved a critical increment in outflow area which was effective for improving LVOT hemodynamics, particularly for subjects with a small neo-left ventricular outflow tract (neo-LVOT).
RESUMEN
This paper provides a review of engineering applications and computational methods used to analyze the dynamics of heart valve closures in healthy and diseased states. Computational methods are a cost-effective tool that can be used to evaluate the flow parameters of heart valves. Valve repair and replacement have long-term stability and biocompatibility issues, highlighting the need for a more robust method for resolving valvular disease. For example, while fluid-structure interaction analyses are still scarcely utilized to study aortic valves, computational fluid dynamics is used to assess the effect of different aortic valve morphologies on velocity profiles, flow patterns, helicity, wall shear stress, and oscillatory shear index in the thoracic aorta. It has been analyzed that computational flow dynamic analyses can be integrated with other methods to create a superior, more compatible method of understanding risk and compatibility.
RESUMEN
PURPOSE: This study examined changes in force distribution between the neochordae corresponding to different ventricular anchor locations. DESCRIPTION: Seven porcine mitral valves were mounted in a left heart simulator. Neochordae (expanded polytetrafluoroethylene) originated from either a simulated left ventricular apex, papillary muscle base, or papillary muscle tip location. The neochordae were attached at three sites along the P2 leaflet segment: P2Lateral; P2Center, and P2Medial. Mitral regurgitation was induced by cutting posterior leaflet P2 marginal chordae. The forces on each neochord required to restore normal mitral valve coaptation were quantified for different ventricular anchoring origins and leaflet insertion sites. EVALUATION: The results showed that under both normotensive and hypertensive conditions, the force exerted was much higher at P2Center than either P2Lateral or P2Medial, independent of ventricular anchor location. Also, forces on both P2Lateral and P2Medial were not statistically different. CONCLUSIONS: Artificial neochordae treatment for all anchoring locations was effective in correcting induced mitral regurgitation. The P2 central neochordae had a significantly higher force than both lateral neochords under all conditions.
Asunto(s)
Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Animales , Cuerdas Tendinosas/cirugía , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Músculos Papilares/cirugía , PorcinosRESUMEN
OBJECTIVE: With the recent expanded indication for transcatheter aortic valve replacement to low-risk surgical patients, thrombus formation in the neosinus is of particular interest due to concerns of reduced leaflet motion and long-term transcatheter heart valve durability. Although flow stasis likely plays a role, a direct connection between neosinus flow stasis and thrombus severity is yet to be established. METHODS: Patients (n = 23) were selected to minimize potential confounding factors related to thrombus formation. Patient-specific 3-dimensional reconstructed in vitro models were created to replicate in vivo anatomy and valve deployment using the patient-specific cardiac output and idealized coronary flows. Dye was injected into each neosinus to quantify washout time as a measure of flow stasis. RESULTS: Flow stasis (washout time) showed a significant, positive correlation with thrombus volume in the neosinus (rho = 0.621, P < .0001). Neither thrombus volume nor washout time was significantly different in the left, right, and noncoronary neosinuses (P ≥ .54). CONCLUSIONS: This is the first patient-specific study correlating flow stasis with thrombus volume in the neosinus post-transcatheter aortic valve replacement across multiple valve types and sizes. Neosinus-specific factors create hemodynamic and thrombotic variability within individual patients. Measurement of neosinus flow stasis may guide strategies to improve outcomes in transcatheter aortic valve replacement.
Asunto(s)
Enfermedades de la Aorta , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Enfermedades de la Aorta/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Humanos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodosRESUMEN
AIMS: To characterize the dynamic nature of the left ventricular outflow tract (LVOT) geometry and flow rate in patients following transcatheter mitral valve replacement (TMVR) with anterior leaflet laceration (LAMPOON) and derive insights to help guide future patient selection. METHODS AND RESULTS: Time-resolved LVOT geometry and haemodynamics were analysed with post-procedure computed tomography and echocardiography in subjects (N = 19) from the LAMPOON investigational device exemption trial. A novel post hoc definition for LVOT obstruction was employed to account for systolic flow rate and quality of life improvement [obstruction was defined as LVOT gradient >30 mmHg or LVOT effective orifice area (EOA) ≤1.15 cm2]. The neo-LVOT and skirt neo-LVOT were observed to vary substantially in area throughout systole (64 ± 27% and 25 ± 14% change in area, respectively). The peak systolic flow rate occurred most commonly just prior to mid-systole, while minimum neo-LVOT (and skirt neo-LVOT) area occurred most commonly in early-diastole. Subjects with LVOT obstruction (n = 5) had smaller skirt neo-LVOT values across systole. Optimal thresholds for skirt neo-LVOT area were phase-specific (260, 210, 200, and 180 mm2 for early-systole, peak flow, mid-systole, and end-systole, respectively). CONCLUSION: The LVOT geometry and flow rate exhibit dynamic characteristics following TMVR with LAMPOON. Subjects with LVOT obstruction had smaller skirt neo-LVOT areas across systole. The authors recommend the use of phase-specific threshold values for skirt neo-LVOT area to guide future patient selection for this procedure. LVOT EOA is a 'flow-independent' metric which has the potential to aid in characterizing LVOT obstruction severity.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Obstrucción del Flujo Ventricular Externo , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Calidad de Vida , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugíaRESUMEN
PURPOSE: Leaflet thrombosis is a significant adverse event after transcatheter aortic valve (TAV) replacement (TAVR). The purpose of our study was to present a semi-empirical, mathematical model that links patient-specific anatomic, valve, and flow parameters to predict likelihood of leaflet thrombosis. METHODS: The two main energy sources of neo-sinus (NS) washout after TAVR include the jet flow downstream of the TAV and NS geometric change in volume due to the leaflets opening and closing. Both are highly dependent on patient anatomic and hemodynamic factors. As rotation of blood flow is prevalent in both the sinus of Valsalva and then the NS, we adopted the vorticity flux or circulation (Ð) as a metric quantifying overall washout. Leaflet thrombus volumes were segmented based on hypo-attenuating leaflet thickening (HALT) in post-TAVR patient's gated computed tomography. Ð was assessed using dimensional scaling as well as computational fluid dynamics (CFD) respectively and correlated to the thrombosis volumes using sensitivity and specificity analysis. RESULTS: Ð in the NS, that accounted for patient flow and anatomic conditions derived from scaling arguments significantly better predicted the occurrence of leaflet thrombus than CFD derived measures such as stasis volumes or wall shear stress. Given results from the six patient datasets considered herein, a threshold Ð value of 28.0 yielded a sensitivity and specificity of 100% where patients with Gamma < 28 developed valve thrombosis. A 10% error in measurements of all variables can bring the sensitivity specificity down to 87%. CONCLUSION: A predictive model relating likelihood of valve thrombosis using Ð in the NS was developed with promising sensitivity and specificity. With further studies and improvements, this predictive technology may lead to alerting physicians on the risk for thrombus formation following TAVR.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Hemodinámica , Humanos , Hidrodinámica , Modelos Cardiovasculares , Trombosis/diagnóstico por imagen , Trombosis/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
This hemodynamic feasibility study examined total cavopulmonary connection (TCPC) designs connecting the extracardiac conduit to the anterior surface of pulmonary arteries (PAs) or superior vena cava (SVC) rather than to the inferior PA surface (traditional TCPC). The study involved twenty-five consecutive Fontan patients meeting inclusion criteria from a single institution. A virtual surgical platform mimicked the completed traditional TCPC and generated three anterior anastomosis designs: Anterior-PA, Middle-SVC, and SVC-Inn (Inn: innominate vein). Hemodynamic performance of anterior anastomosis designs was compared with the traditional TCPC regarding indexed power loss (iPL) and hepatic flow distribution (HFD). Compared to the traditional TCPC, the Anterior-PA design produces a similar iPL. The Middle-SVC design is also similar, though the iPL difference is positively correlated with the anastomosing height. The SVC-Inn design had significantly more iPL. The three anterior anastomosis designs did not have a significant difference in HFD (from traditional TCPC). Pulmonary flow distribution (PFD) has a stronger correlation with HFD from the anterior anastomosis designs than the traditional TCPC. This hemodynamic feasibility study examined anterior anastomosis, extracardiac TCPC designs that may offer surgeons clinical dexterity. The Anterior-PA design may be equivalent to the traditional TCPC. Fontan extracardiac conduit anastomosis just superior to the PAs (Middle-SVC) also preserves hemodynamic performance and avoids direct PA anastomosis. These designs could simplify surgical Fontan completion, and may particularly benefit patients requiring surgical dissection, having atypical PA orientation, or after PA stent angioplasty.
Asunto(s)
Procedimiento de Fontan , Cardiopatías Congénitas , Procedimiento de Fontan/efectos adversos , Cardiopatías Congénitas/cirugía , Hemodinámica , Humanos , Pulmón , Arteria Pulmonar/cirugía , Vena Cava Superior/cirugíaRESUMEN
In silico modeling has been proposed as a tool to simulate left ventricular (LV) outflow tract (LVOT) obstruction in patients undergoing transcatheter mitral valve replacement (TMVR). This study validated a simplified approach to simulate LV outflow hemodynamics in the setting of TMVR with anterior leaflet laceration, a clinical technique used to mitigate the risk of LVOT obstruction. Personalized, 3-dimensional computational fluid dynamics models were developed from computed tomography images of six patients who underwent TMVR with anterior leaflet laceration. LV outflow hemodynamics were simulated using the patient-specific anatomy and the peak systolic flow rate as boundary conditions. The peak outflow velocity, a clinically relevant hemodynamic metric, was extracted from each simulation (vsim-peak) and compared with the clinical measurement from Doppler echocardiography (vclin-peak) for validation. In silico models were successfully developed and implemented for all patients. The pre-processing time was 2 h per model and the simulation could be completed within 3 h. In three patients, the lacerated anterior leaflet exposed open cells of the transcatheter valve to flow. Good agreement was obtained between vsim-peak and vclin-peak (r = 0.97, p < 0.01) with average discrepancies of 5 ± 2% and 14 ± 1% for patients with exposed and unexposed cells of the transcatheter valve, respectively. The proposed in silico modeling paradigm therefore simulated LV outflow hemodynamics in a time-efficient manner and demonstrated good agreement with clinical measurements. Future studies should investigate the ability of this paradigm to support clinical applications.