Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
Opt Express ; 32(3): 3402-3424, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38297562

RESUMEN

Rotor-stator axial clearance plays a pivotal role in ensuring the safety and efficiency of major rotating machinery. This paper introduces an innovative clearance measurement method based on wavelength division multiplexing (WDM) combined with all-fiber microwave photonic mixing. The method is distinguished by large measurement range, high accuracy and low drift. The WDM-based common optical path structure is established. A comprehensive theoretical model of axial clearance drift determined by wavelength and temperature is developed based on the thermo-optic effect of optical fiber material. To efficiently separate measurement and reference light at the probe, the optical design for a compact optical bandpass filter (OBPF) fiber sensor probe is proposed. The performance of the method is substantiated by simulations and experiments. The results demonstrate an accuracy of better than 2.8µm over a 23.5 mm range, surpassing existing methods. The method's capability to mitigate temperature-induced drift is further confirmed through high-temperature drift and comparative experiments.

2.
Appl Opt ; 62(29): 7819-7827, 2023 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-37855492

RESUMEN

In the domain of frequency sweeping interferometry, the accurate extraction of distance information from nonlinear frequency scanning signals holds paramount significance in ensuring meticulous measurements of high precision. This paper presents a novel, to the best of our knowledge, high-speed distance extraction algorithm based on the table lookup method and validates its feasibility through theoretical models, simulations, and practical experiments. The proposed algorithm achieves comparable accuracy to traditional methods involving resampling and Hilbert transform. However, it outperforms them in robustness against noise and variations in sampling points. This method can accurately process signals sampled even below the Nyquist sampling rate. The simplicity and computational efficiency of the proposed approach make it suitable for various nonlinear sampling applications, promising broad applicability in scientific and engineering contexts.

3.
Opt Express ; 31(17): 28549-28563, 2023 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-37710906

RESUMEN

Rotor-stator axial clearance is a crucial design parameter affecting rotating machines' efficiency and safety. To accurately measure the dynamic axial clearance in high-speed machinery, a precise method based on time division multiplexing with frequency domain interferometry has been proposed. This method has proven robust and accurate through simulations and experiments. The inclusion of an optical switch enables the utilization of dispersive interferometry(DPI) and time division multiplexing for multiple channels of the light source. It achieves a static accuracy of 1.5 µm for a 15 mm range and a dynamic accuracy of 9 µm at 3000 rpm.

4.
Opt Express ; 31(13): 20994-21013, 2023 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-37381210

RESUMEN

In this paper, a high-accuracy measurement method for rotor-stator axial clearance in narrow spaces is proposed. The optical path structure based on all-fiber microwave photonic mixing is established. To improve the accuracy and expand the measurement range, the total coupling efficiency over the entire measurement range at different working distances of fiber probe was evaluated by Zemax analysis tool and theoretical model. The performance of the system was verified by experiments. The experimental results show that the measurement accuracy of axial clearance is better than 10.5 um within the range of 0.5-20.5 mm. The measurement accuracy has been effectively improved compared to previous methods. Additionally, the probe size is reduced to a mere diameter of 2.78 mm, which is more suitable for axial clearance measurement in narrow spaces inside rotating machines.

5.
Opt Express ; 31(3): 4652-4666, 2023 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-36785427

RESUMEN

A robust five-degree-of-freedom (5-DOF) measurement system is proposed in this paper. The compact optical configuration with high resolution is designed based on lens combination and multiple reflections. Beam drift and dual-beam parallelism are monitored and compensated by autocollimator units and a polarizer unit respectively. In addition, a protection method is proposed to reduce the intensity of air turbulence by reducing the Reynolds number of the beam path. The performance of the system is verified by experiments. The experimental results show that the self-compensation methods and air turbulence protection can effectively improve the accuracy and stability of the system under the long-term interference of external environments. The proposed system has high precision, desirable robustness, and convenient pre-calibration, which can be used for error measurement of precision machines.

6.
Artículo en Inglés | MEDLINE | ID: mdl-12219228

RESUMEN

The time-resolved polarized fluorescence of oriented R-phycoerythrin single crystal from red alga Porphyra yezoensis was studied in picosecond time scale. The fluorescence decay of the crystal exhibited two exponential processes, one of which was related to the energy transfer and excitation equilibrium between chromophores (tau(1)

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA