Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
2.
J Cardiothorac Surg ; 9: 81, 2014 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-24885948

RESUMEN

BACKGROUND: Left ventricular hypertrophy (LVH) is a potent risk factor for sudden death and congestive heart failure. METHODS: We tested the effect of sorafenib, a multikinase inhibitor (10 mg/kg, given orally, starting 2 days prior to banding, till sacrifice on day 14), on the development of LVH following aortic banding in rats. RESULTS: The latter resulted in significant LVH caused by both an increase in cardiomyocyte volume and interstitial collagen deposition. The observed LVH was entirely blocked by sorafenib downregulating both of these components. LVH was associated with PDGF-BB and TGFß1 overexpression, as well as phosphorylation of c-raf and ERK1/2. Additionally, the transcription factors c-myc and c-fos leading to proliferation as well as the hypertrophy-inducing transcription factor GATA4 and its regulated gene ANP were all upregulated in response to aortic banding. All these overexpressions and upregulations were inhibited upon sorafenib treatment. CONCLUSION: We show that sorafenib exhibits a regulatory role on the occurrence of LVH following AB in rats by blocking the rise in growth factors PDGF-BB and TGFß1, activation of the corresponding c-Raf-ERK1/2 signaling pathway and effector mechanisms, including GATA4 and ANP. This effect of sorafenib may be of clinical importance in modulating the maladaptive hypertrophic response to pressure overload.


Asunto(s)
Regulación de la Expresión Génica/efectos de los fármacos , Hipertrofia Ventricular Izquierda/prevención & control , Sistema de Señalización de MAP Quinasas/efectos de los fármacos , Niacinamida/análogos & derivados , Compuestos de Fenilurea/farmacología , Proteínas Proto-Oncogénicas c-raf/genética , ARN/genética , Animales , Becaplermina , Presión Sanguínea , Western Blotting , Modelos Animales de Enfermedad , Ensayo de Inmunoadsorción Enzimática , Ventrículos Cardíacos/metabolismo , Ventrículos Cardíacos/fisiopatología , Hipertrofia Ventricular Izquierda/genética , Hipertrofia Ventricular Izquierda/metabolismo , Masculino , Niacinamida/farmacología , Fosforilación , Inhibidores de Proteínas Quinasas/farmacología , Proteínas Proto-Oncogénicas c-raf/metabolismo , Proteínas Proto-Oncogénicas c-sis/biosíntesis , Proteínas Proto-Oncogénicas c-sis/genética , Ratas , Ratas Endogámicas Lew , Receptores de Factores de Crecimiento Endotelial Vascular , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Transducción de Señal/efectos de los fármacos , Sorafenib , Factor de Crecimiento Transformador beta1/biosíntesis , Factor de Crecimiento Transformador beta1/genética
3.
Eur J Clin Pharmacol ; 70(2): 215-23, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24150532

RESUMEN

PURPOSE: Hyperkalaemia due to potassium-increasing drug-drug interactions (DDIs) is a clinically important adverse drug event. The purpose of this study was to identify patient- and physician-related risk factors for the development of hyperkalaemia. METHODS: The risk for adult patients hospitalised in the University Hospital Zurich between 1 December 2009 and 31 December 2011 of developing hyperkalaemia was correlated with patient characteristics, number, type and duration of potassium-increasing DDIs and frequency of serum potassium monitoring. RESULTS: The 76,467 patients included in this study were prescribed 8,413 potentially severe potassium-increasing DDIs. Patient-related characteristics associated with the development of hyperkalaemia were pulmonary allograft [relative risk (RR) 5.1; p < 0.0001), impaired renal function (RR 2.7; p < 0.0001), diabetes mellitus (RR 1.6; p = 0.002) and female gender (RR 1.5; p = 0.007). Risk factors associated with medication were number of concurrently administered potassium-increasing drugs (RR 3.3 per additional drug; p < 0.0001) and longer duration of the DDI (RR 4.9 for duration ≥6 days; p < 0.0001). Physician-related factors associated with the development of hyperkalaemia were undetermined or elevated serum potassium level before treatment initiation (RR 2.2; p < 0.001) and infrequent monitoring of serum potassium during a DDI (interval >48 h: RR 1.6; p < 0.01). CONCLUSION: Strategies for reducing the risk of hyperkalaemia during potassium-increasing DDIs should consider both patient- and physician-related risk factors.


Asunto(s)
Interacciones Farmacológicas , Hiperpotasemia/inducido químicamente , Hiperpotasemia/epidemiología , Pautas de la Práctica en Medicina/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Diabetes Mellitus/epidemiología , Femenino , Humanos , Hiperpotasemia/sangre , Trasplante de Pulmón , Masculino , Persona de Mediana Edad , Potasio/sangre , Insuficiencia Renal/epidemiología , Factores de Riesgo , Factores Sexuales , Suiza/epidemiología
4.
Stud Health Technol Inform ; 192: 1056, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23920830

RESUMEN

Electronic alerts for preventing hyperkalaemia during potassium-increasing drug-drug-interactions (DDIs) are often overridden due to their low specificity. Treatments of 76,467 inpatients were retrospectively analysed to establish more specific alerts. Alerting concepts for identifying DDIs that induced hyperkalaemia (serum potassium ≥5.5 mEq/l were compared. The positive predictive value (PPV) of alerts was 2.9% if they were triggered at onset of each potassium-increasing DDI. The PPV increased to 5.1% if alerts at onset were suppressed for serum potassium levels of <4.0 mEq/l. The PPV rose to 24.2% with a novel approach, triggering alerts whenever an elevated potassium level of >4.8 mEq/l was detected at onset or during the entire DDI period. Thus, triggering DDI alerts based on periodically monitored potassium levels may improve specificity of alerts and thereby reduce alert fatigue.


Asunto(s)
Sistemas de Registro de Reacción Adversa a Medicamentos/organización & administración , Sistemas de Apoyo a Decisiones Clínicas/organización & administración , Interacciones Farmacológicas , Hiperpotasemia/diagnóstico , Hiperpotasemia/prevención & control , Sistemas de Entrada de Órdenes Médicas/organización & administración , Potasio/sangre , Diagnóstico por Computador/métodos , Humanos , Hiperpotasemia/sangre , Sistemas de Medicación en Hospital/organización & administración , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Suiza
5.
Stud Health Technol Inform ; 180: 1200-2, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22874400

RESUMEN

Computer-triggered reminders alerting physicians on every potentially harmful drug-drug-interaction (DDI) induce alert fatigue due to frequent messages of limited clinical relevance. On demand DDI-checks, however, are not commonly used by physicians. Optimal strategies for sustained quality assurance have to consider patients' risk factors and focus on the most significant DDIs only. An approach is proposed based on the analysis of concurrent prescription of potassium-sparing diuretics and potassium supplements (CPPP), which are the most frequent DDIs classified as contraindicated. Although the frequency of monitoring potassium serum levels declined during prolonged periods of CPPP, the likelihood of observing a hyperkalaemia increased. The median treatment period of CPPP was 3.3 days, whereas hyperkalaemia occurred after a median observation time of 4.5 days of CPPP. Thus, computer-triggered reminders for ordering potassium serum levels may be indicated if monitoring has been discontinued after 48h of CPPP.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas/estadística & datos numéricos , Interacciones Farmacológicas , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/diagnóstico , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/epidemiología , Hiperpotasemia/sangre , Hiperpotasemia/inducido químicamente , Potasio/sangre , Quimioterapia Asistida por Computador , Humanos , Hiperpotasemia/prevención & control , Sistemas Recordatorios , Suiza/epidemiología
6.
Biomaterials ; 33(33): 8277-85, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22906604

RESUMEN

Living autologous tissue engineered vascular-grafts (TEVGs) with growth-capacity may overcome the limitations of contemporary artificial-prostheses. However, the multi-step in vitro production of TEVGs requires extensive ex vivo cell-manipulations with unknown effects on functionality and quality of TEVGs due to an accelerated biological age of the cells. Here, the impact of biological cell-age and tissue-remodeling capacity of TEVGs in relation to their clinical long-term functionality are investigated. TEVGs were implanted as pulmonary-artery (PA) replacements in juvenile sheep and followed for up to 240 weeks (∼4.5years). Telomere length and telomerase activity were compared amongst TEVGs and adjacent native tissue. Telomerase-activity of in vitro expanded autologous vascular-cells prior to seeding was <5% as compared to a leukemic cell line, indicating biological-aging associated with decreasing telomere-length with each cellular-doubling. Up to 100 weeks, the cells in the TEVGs had consistently shorter telomeres compared to the native counterpart, whereas no significant differences were detectable at 240 weeks. Computed tomography (CT) analysis demonstrated physiological wall-pressures, shear-stresses, and flow-pattern comparable to the native PA. There were no signs of degeneration detectable and continuous native-analogous growth was confirmed by vessel-volumetry. TEVGs exhibit a higher biological age compared to their native counterparts. However, despite of this tissue engineering technology related accelerated biological-aging, growth-capacity and long-term functionality was not compromised. To the contrary, extensive in-vivo remodeling processes with substantial endogenous cellular turnover appears to result in "TEVG rejuvenation" and excellent clinical performance. As these large-animal results can be extrapolated to approximately 20 human years, this study suggests long-term clinical-safety of cardiovascular in vitro tissue engineering and may contribute to safety-criteria as to first-in-man clinical-trials.


Asunto(s)
Envejecimiento/fisiología , Células Endoteliales/citología , Ingeniería de Tejidos/métodos , Animales , Células Cultivadas , Células Endoteliales/metabolismo , Citometría de Flujo , Inmunohistoquímica , Arteria Pulmonar/citología , Ovinos , Telomerasa/metabolismo , Telómero/metabolismo
7.
JACC Cardiovasc Interv ; 5(8): 874-83, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22917460

RESUMEN

OBJECTIVES: This study sought to investigate the combination of transcatheter aortic valve implantation and a novel concept of stem cell-based, tissue-engineered heart valves (TEHV) comprising minimally invasive techniques for both cell harvest and valve delivery. BACKGROUND: TAVI represents an emerging technology for the treatment of aortic valve disease. The used bioprostheses are inherently prone to calcific degeneration and recent evidence suggests even accelerated degeneration resulting from structural damage due to the crimping procedures. An autologous, living heart valve prosthesis with regeneration and repair capacities would overcome such limitations. METHODS: Within a 1-step intervention, trileaflet TEHV, generated from biodegradable synthetic scaffolds, were integrated into self-expanding nitinol stents, seeded with autologous bone marrow mononuclear cells, crimped and transapically delivered into adult sheep (n = 12). Planned follow-up was 4 h (Group A, n = 4), 48 h (Group B, n = 5) or 1 and 2 weeks (Group C, n = 3). TEHV functionality was assessed by fluoroscopy, echocardiography, and computed tomography. Post-mortem analysis was performed using histology, extracellular matrix analysis, and electron microscopy. RESULTS: Transapical implantation of TEHV was successful in all animals (n = 12). Follow-up was complete in all animals of Group A, three-fifths of Group B, and two-thirds of Group C (1 week, n = 1; 2 weeks, n = 1). Fluoroscopy and echocardiography displayed TEHV functionality demonstrating adequate leaflet mobility and coaptation. TEHV showed intact leaflet structures with well-defined cusps without signs of thrombus formation or structural damage. Histology and extracellular matrix displayed a high cellularity indicative for an early cellular remodeling and in-growth after 2 weeks. CONCLUSIONS: We demonstrate the principal feasibility of a transcatheter, stem cell-based TEHV implantation into the aortic valve position within a 1-step intervention. Its long-term functionality proven, a stem cell-based TEHV approach may represent a next-generation heart valve concept.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Trasplante de Células Madre , Animales , Cateterismo Cardíaco , Modelos Animales , Ovinos
8.
Biomaterials ; 33(16): 4031-43, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22421386

RESUMEN

Prenatal heart valve interventions aiming at the early and systematic correction of congenital cardiac malformations represent a promising treatment option in maternal-fetal care. However, definite fetal valve replacements require growing implants adaptive to fetal and postnatal development. The presented study investigates the fetal implantation of prenatally engineered living autologous cell-based heart valves. Autologous amniotic fluid cells (AFCs) were isolated from pregnant sheep between 122 and 128 days of gestation via transuterine sonographic sampling. Stented trileaflet heart valves were fabricated from biodegradable PGA-P4HB composite matrices (n = 9) and seeded with AFCs in vitro. Within the same intervention, tissue engineered heart valves (TEHVs) and unseeded controls were implanted orthotopically into the pulmonary position using an in-utero closed-heart hybrid approach. The transapical valve deployments were successful in all animals with acute survival of 77.8% of fetuses. TEHV in-vivo functionality was assessed using echocardiography as well as angiography. Fetuses were harvested up to 1 week after implantation representing a birth-relevant gestational age. TEHVs showed in vivo functionality with intact valvular integrity and absence of thrombus formation. The presented approach may serve as an experimental basis for future human prenatal cardiac interventions using fully biodegradable autologous cell-based living materials.


Asunto(s)
Líquido Amniótico/citología , Sangre Fetal/citología , Válvulas Cardíacas/citología , Ovinos/embriología , Células Madre/citología , Ingeniería de Tejidos , Animales , Materiales Biocompatibles , Fenómenos Biomecánicos , Válvulas Cardíacas/diagnóstico por imagen , Ultrasonografía Prenatal
9.
Eur J Cardiothorac Surg ; 41(1): 167-72, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21530291

RESUMEN

OBJECTIVES: We have previously demonstrated the functionality and growth of autologous, living, tissue-engineered vascular grafts (TEVGs) in long-term animal studies. These grafts showed substantial in vivo tissue remodeling and approximation to native arterial wall characteristics. Based on this, in vitro and in vivo matrix metalloproteinase (MMP) activity of TEVGs is investigated as a key marker of matrix remodeling. METHODS: TEVGs fabricated from biodegradable scaffolds (polyglycolic-acid/poly-4-hydroxybutyrate, PGA/P4HB) seeded with autologous vascular cells were cultured in static and dynamic in vitro conditions. Thereafter, TEVGs were implanted as pulmonary artery replacements in lambs and followed up for 2 years. Gelatin gel zymography to detect MMP-2 and -9 was performed and collagen content quantified (n=5). Latent (pro) and active MMP-2 and -9 were detected. RESULTS: Comparable levels of active MMP-9 and pro-MMP-2 were detected in static and dynamic culture. Higher levels of active MMP-2 were detected in dynamic cultures. Expression of MMP-2 and -9 was minimal in native grafts but was increased in implanted TEVG. Pro-MMP-9 was expressed 20 weeks post implantation and persisted up to 80 weeks post implantation. Collagen content in vitro was increased in dynamically conditioned TEVG as compared with static constructs and was increased in vivo compared with the corresponding native pulmonary artery. CONCLUSIONS: MMPs are up-regulated in vitro by dynamic culture conditions and could contribute to increased matrix remodeling, native analogous tissue formation and functional growth of TEVGs in vivo. Monitoring of MMP activity, for example, by molecular imaging techniques, may enable the non-invasive assessment of functional tissue quality in future clinical tissue-engineering applications.


Asunto(s)
Prótesis Vascular , Metaloproteinasas de la Matriz/metabolismo , Ingeniería de Tejidos/métodos , Implantes Absorbibles , Animales , Biomarcadores/metabolismo , Implantación de Prótesis Vascular , Colágeno/metabolismo , Modelos Animales de Enfermedad , Metaloproteinasa 2 de la Matriz/metabolismo , Metaloproteinasa 9 de la Matriz/metabolismo , Arteria Pulmonar/enzimología , Arteria Pulmonar/patología , Arteria Pulmonar/cirugía , Ovinos , Técnicas de Cultivo de Tejidos , Andamios del Tejido
10.
Eur Heart J ; 32(22): 2830-40, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21415068

RESUMEN

AIMS: A living heart valve with regeneration capacity based on autologous cells and minimally invasive implantation technology would represent a substantial improvement upon contemporary heart valve prostheses. This study investigates the feasibility of injectable, marrow stromal cell-based, autologous, living tissue engineered heart valves (TEHV) generated and implanted in a one-step intervention in non-human primates. METHODS AND RESULTS: Trileaflet heart valves were fabricated from non-woven biodegradable synthetic composite scaffolds and integrated into self-expanding nitinol stents. During the same intervention autologous bone marrow-derived mononuclear cells were harvested, seeded onto the scaffold matrix, and implanted transapically as pulmonary valve replacements into non-human primates (n = 6). The transapical implantations were successful in all animals and the overall procedure time from cell harvest to TEHV implantation was 118 ± 17 min. In vivo functionality assessed by echocardiography revealed preserved valvular structures and adequate functionality up to 4 weeks post implantation. Substantial cellular remodelling and in-growth into the scaffold materials resulted in layered, endothelialized tissues as visualized by histology and immunohistochemistry. Biomechanical analysis showed non-linear stress-strain curves of the leaflets, indicating replacement of the initial biodegradable matrix by living tissue. CONCLUSION: Here, we provide a novel concept demonstrating that heart valve tissue engineering based on a minimally invasive technique for both cell harvest and valve delivery as a one-step intervention is feasible in non-human primates. This innovative approach may overcome the limitations of contemporary surgical and interventional bioprosthetic heart valve prostheses.


Asunto(s)
Prótesis Valvulares Cardíacas , Trasplante de Células Madre Mesenquimatosas , Monocitos/trasplante , Válvula Pulmonar/fisiología , Trasplante de Células Madre/métodos , Animales , Bioprótesis , Estudios de Factibilidad , Citometría de Flujo , Supervivencia de Injerto/fisiología , Inyecciones , Microscopía Electrónica de Rastreo , Papio ursinus , Stents , Ingeniería de Tejidos , Andamios del Tejido , Trasplante Autólogo
11.
J Am Coll Cardiol ; 56(6): 510-20, 2010 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-20670763

RESUMEN

OBJECTIVES: The aim of this study was to demonstrate the feasibility of combining the novel heart valve replacement technologies of: 1) tissue engineering; and 2) minimally-invasive implantation based on autologous cells and composite self-expandable biodegradable biomaterials. BACKGROUND: Minimally-invasive valve replacement procedures are rapidly evolving as alternative treatment option for patients with valvular heart disease. However, currently used valve substitutes are bioprosthetic and as such have limited durability. To overcome this limitation, tissue engineering technologies provide living autologous valve replacements with regeneration and growth potential. METHODS: Trileaflet heart valves fabricated from biodegradable synthetic scaffolds, integrated in self-expanding stents and seeded with autologous vascular or stem cells (bone marrow and peripheral blood), were generated in vitro using dynamic bioreactors. Subsequently, the tissue engineered heart valves (TEHV) were minimally-invasively implanted as pulmonary valve replacements in sheep. In vivo functionality was assessed by echocardiography and angiography up to 8 weeks. The tissue composition of explanted TEHV and corresponding control valves was analyzed. RESULTS: The transapical implantations were successful in all animals. The TEHV demonstrated in vivo functionality with mobile but thickened leaflets. Histology revealed layered neotissues with endothelialized surfaces. Quantitative extracellular matrix analysis at 8 weeks showed higher values for deoxyribonucleic acid, collagen, and glycosaminoglycans compared to native valves. Mechanical profiles demonstrated sufficient tissue strength, but less pliability independent of the cell source. CONCLUSIONS: This study demonstrates the principal feasibility of merging tissue engineering and minimally-invasive valve replacement technologies. Using adult stem cells is successful, enabling minimally-invasive cell harvest. Thus, this new technology may enable a valid alternative to current bioprosthetic devices.


Asunto(s)
Endotelio Vascular/trasplante , Prótesis Valvulares Cardíacas , Válvulas Cardíacas , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Músculo Liso Vascular/trasplante , Trasplante de Células Madre/métodos , Ingeniería de Tejidos/métodos , Animales , Modelos Animales de Enfermedad , Endotelio Vascular/citología , Estudios de Seguimiento , Músculo Liso Vascular/citología , Ovinos , Andamios del Tejido , Trasplante Autólogo
12.
J Biotechnol ; 148(1): 46-55, 2010 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-20223267

RESUMEN

Current scientific attempts to generate in vitro tissue-engineered living blood vessels (TEBVs) show substantial limitations, thereby preventing routine clinical use. In the present report, we describe a novel biotechnology concept to create living small diameter TEBV based exclusively on microtissue self-assembly (living cellular re-aggregates). A novel bioreactor was designed to assemble microtissues in a vascular shape and apply pulsatile flow and circumferential mechanical stimulation. Microtissues composed of human artery-derived fibroblasts (HAFs) and endothelial cells (HUVECs) were accumulated and cultured for 7 and 14 days under pulsatile flow/mechanical stimulation or static culture conditions with a diameter of 3mm and a wall thickness of 1mm. The resulting vessels were analyzed by immunohistochemistry for extracellular matrix (ECM) and cell phenotype (von Willebrand factor, alpha-SMA, Ki67, VEGF). Self-assembled microtissues composed of fibroblasts displayed significantly accelerated ECM formation compared to monolayer cell sheets. Accumulation of vessel-like tissue occurred within 14 days under both, static and flow/mechanical stimulation conditions. A layered tissue formation was observed only in the dynamic group, as indicated by luminal aligned alpha-SMA positive fibroblasts. We could demonstrate that self-assembled cell-based microtissues can be used to generate small diameter TEBV. The significant enhancement of ECM expression and maturation, together with the pre-vascularization capacity makes this approach highly attractive in terms of generating functional small diameter TEBV devoid of any foreign material.


Asunto(s)
Arterias/citología , Reactores Biológicos , Prótesis Vascular , Técnicas de Cultivo de Tejidos , Ingeniería de Tejidos , Actinas/metabolismo , Fenómenos Biomecánicos , Colágeno Tipo IV/metabolismo , Células Endoteliales/citología , Fibroblastos/citología , Perfilación de la Expresión Génica , Humanos , Inmunohistoquímica , Modelos Cardiovasculares , Técnicas de Cultivo de Tejidos/instrumentación , Técnicas de Cultivo de Tejidos/métodos , Ingeniería de Tejidos/instrumentación , Ingeniería de Tejidos/métodos , Factor A de Crecimiento Endotelial Vascular/metabolismo , Factor de von Willebrand/metabolismo
13.
Eur J Cardiothorac Surg ; 35(5): 839-46; discussion 846, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19237290

RESUMEN

OBJECTIVE: Cardioprotective properties of recombinant human Erythropoietin (rhEpo) have been shown in in vivo regional or ex vivo global models of ischemia-reperfusion (I/R) injury. The aim of this study was to characterize the cardioprotective potential of rhEPO in an in vivo experimental model of global I/R approximating the clinical cardiac surgical setting and to gain insights into the myocardial binding sites of rhEpo and the mechanism involved in its cardioprotective effect. METHODS: Hearts of donor Lewis rats were arrested with cold crystalloid cardioplegia and after 45 min of cold global ischemia grafted heterotopically into the abdomen of recipient Lewis rats. Recipients were randomly assigned to control non-treated or Epo-treated group receiving 5000 U/kg of rhEpo intravenously 20 min prior to reperfusion. At 5 time points 5-1440 min after reperfusion, the recipients (n=6-8 at each point) were sacrificed, blood and native and grafted hearts harvested for subsequent analysis. RESULTS: Treatment with rhEpo resulted in a significant reduction in myocardial I/R injury (plasma troponin T) in correlation with preservation of the myocardial redox state (reduced glutathione). The extent of apoptosis (activity of caspase 3 and caspase 9, TUNEL test) in our model was very modest and not significantly affected by rhEpo. Immunostaining of the heart tissue with anti-Epo antibodies showed an exclusive binding of rhEpo to the coronary endothelium with no binding of rhEpo to cardiomyocytes. Administration of rhEpo resulted in a significant increase in nitric oxide (NO) production assessed by plasma nitrite levels. Immunostaining of heart tissue with anti-phospho-eNOS antibodies showed that after binding to the coronary endothelium, rhEpo increased the phosphorylation and thus activation of endothelial nitric oxide synthase (eNOS) in coronary vessels. There was no activation of eNOS in cardiomyocytes. CONCLUSIONS: Intravenous administration of rhEpo protects the heart against cold global I/R. Apoptosis does not seem to play a major role in the process of tissue injury in this model. After binding to the coronary endothelium, rhEpo enhances NO production by phosphorylation and thus activation of eNOS in coronary vessels. Our results suggest that cardioprotective properties of rhEpo are at least partially mediated by NO released by the coronary endothelium.


Asunto(s)
Cardiotónicos/uso terapéutico , Vasos Coronarios/efectos de los fármacos , Endotelio Vascular/efectos de los fármacos , Eritropoyetina/uso terapéutico , Daño por Reperfusión Miocárdica/prevención & control , Óxido Nítrico/biosíntesis , Animales , Apoptosis/efectos de los fármacos , Factor Natriurético Atrial/sangre , Agua Corporal/metabolismo , Cardiotónicos/farmacología , Vasos Coronarios/metabolismo , Modelos Animales de Enfermedad , Evaluación Preclínica de Medicamentos/métodos , Endotelio Vascular/metabolismo , Eritropoyetina/farmacología , Trasplante de Corazón/patología , Masculino , Daño por Reperfusión Miocárdica/metabolismo , Daño por Reperfusión Miocárdica/patología , Estrés Oxidativo , Ratas , Ratas Endogámicas Lew , Proteínas Recombinantes , Síndrome de Respuesta Inflamatoria Sistémica/sangre , Síndrome de Respuesta Inflamatoria Sistémica/prevención & control , Troponina T/sangre
14.
Eur J Cardiothorac Surg ; 35(1): 111-5, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18835783

RESUMEN

OBJECTIVE: Monitoring of cardiac surgical patients after transfer from the intensive care unit to the normal ward is incomplete. Undetected hypoxia, however, is known to be a risk factor for occurrence of atrial fibrillation. We have utilized Auricall for continuous wireless monitoring of oxygen saturation and heart rate until discharge. The object of the study was to analyze if oxygen therapy as a result of Auricall alerts of hypoxia can decrease the incidence of postoperative atrial fibrillation. METHODS: Auricall is a wireless portable pulse oximeter. An alert is generated depending on preset threshold values (heart rate, oxygen saturation). Over a period of 6 months, 119 patients were monitored with the Auricall following coronary artery bypass graft and/or valve surgery. Oxygen therapy was started subsequent to an oxygen saturation below 90%. These patients were compared with a cohort of 238 patients from the time period before availability of Auricall. The patient characteristics were comparable in both groups. In a retrospective study, the incidence of atrial fibrillation was measured in both groups. RESULTS: The postoperative AF was observed in 22/119 patients (18%) in group I and in 66/238 patients (28%) in group II. This difference between the two groups approached significance (p=0.056). In the subgroup of patients with coronary artery bypass graft with our without simultaneous valve surgery (n=312), Auricall monitoring resulted in a significantly reduced incidence of atrial fibrillation (14% vs 26%, p=0.016). CONCLUSIONS: Continuous monitoring of oxygen saturation on the normal ward and subsequent oxygen therapy for hypoxia can reduce the incidence of atrial fibrillation in a subgroup of patients after cardiac surgery. Prospective randomized trials are warranted to confirm these data.


Asunto(s)
Fibrilación Atrial/prevención & control , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Hipoxia/diagnóstico , Terapia por Inhalación de Oxígeno , Oxígeno/sangre , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/etiología , Puente de Arteria Coronaria , Femenino , Humanos , Hipoxia/etiología , Hipoxia/terapia , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Cuidados Posoperatorios/métodos , Factores de Riesgo , Telemetría/métodos
15.
J Cardiovasc Pharmacol ; 52(4): 369-74, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18841072

RESUMEN

Smooth muscle cell (SMC) migration contributes to vascular remodeling. Nitric oxide (NO) produced via endothelial NO synthase (eNOS) inhibits SMC migration. This study analyzes signal transduction mechanisms of SMC migration targeted by NO. SMCs were cultured from human saphenous veins, and cell migration was studied using Boyden chambers. PDGF-BB (0.1 to 10 ng/ml) stimulated SMC migration in a concentration-dependent manner, which was inhibited by adenoviral-mediated overexpression of eNOS and by the NO donor diethylentriamine NONOate (DETANO, 10 to 10 mol/L). NO release was enhanced in eNOS-transduced SMCs, and L-NAME blunted the effect of eNOS overexpression on migration. PDGF-BB (10 ng/ml) activated Rho A, which was inhibited by the overexpression of eNOS by DETANO and by 8 bromo-cGMP. The inhibitory effect of DETANO on Rho A activity was prevented by the cGMP-dependant kinase inhibitor. Furthermore, inhibition of Rho A by C3 exoenzyme and inhibition of ROCK by Y-27632 diminished cell migration stimulated by PDGF-BB. Finally, in the cells overexpressing constitutively active ROCK mutant (CAT), DETANO failed to prevent PDGF-BB-induced SMC migration. In conclusion, NO inhibits human SMC migration via blockade of the Rho A pathway.


Asunto(s)
Movimiento Celular/genética , Regulación Enzimológica de la Expresión Génica/genética , Técnicas de Transferencia de Gen , Músculo Liso Vascular/metabolismo , Óxido Nítrico Sintasa de Tipo III/genética , Quinasas Asociadas a rho/antagonistas & inhibidores , Adenoviridae/genética , Becaplermina , Movimiento Celular/fisiología , Células Cultivadas , Medio de Cultivo Libre de Suero , Relación Dosis-Respuesta a Droga , Activación Enzimática/efectos de los fármacos , Humanos , Músculo Liso Vascular/citología , Donantes de Óxido Nítrico/farmacología , Factor de Crecimiento Derivado de Plaquetas/farmacología , Proteínas Proto-Oncogénicas c-sis , Vena Safena/citología
16.
J Heart Valve Dis ; 17(4): 446-55; discussion 455, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18751475

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Fetal stem cells represent a promising cell source for heart valve tissue engineering. In particular, amniotic fluid-derived cells (AFDC) have been shown to lead to autologous fetal-like heart valve tissues in vitro for pediatric application. In order to expand the versatility of these cells also for adult application, cryopreserved AFDC were investigated as a potential life-long available cell source for heart valve tissue engineering. METHODS: Human AFDC were isolated using CD133 magnetic beads, and then differentiated and analyzed. After expansion of CD133- as well as CD133+ cells up to passage 7, a part of the cells was cryopreserved. After four months, the cells were re-cultured and phenotyped by flow cytometry and immunohistochemistry, including expression of CD44, CD105, CD90, CD34, CD31, CD141, eNOS and vWF, and compared to their non-cryopreserved counterparts. The stem cell potential was investigated in differentiation assays. The viability of cryopreserved AFDC for heart valve tissue engineering was assessed by creating heart valve leaflets in vitro. RESULTS: After cryopreservation, amniotic fluid-derived CD133- and CD133+ cells retained their stem cell-like phenotype, expressing mainly CD44, CD90 and CD105. This staining pattern was comparable to that of their non-cryopreserved counterparts. Moreover, CD133- cells demonstrated differentiation potential into osteoblast-like and adipocyte-like cells. CD133+ cells showed characteristics of endothelial-like cells by eNOS, CD141 and beginning vWF expression. When used for the fabrication of heart valve leaflets, cryopreserved CD133- cells produced extracellular matrix elements comparable to their non-cryopreserved counterparts. Moreover, the resulting tissues showed a cellular layered tissue formation covered by functional endothelia. The mechanical properties were similar to those of tissues fabricated from non-cryopreserved cells. CONCLUSION: The study results suggest that the use of cell bank technology fetal amniotic fluid-derived stem cells might represent a life-long available autologous cell source for heart valve tissue engineering, and also for adult application.


Asunto(s)
Líquido Amniótico/citología , Criopreservación , Células Madre Fetales/citología , Válvulas Cardíacas/citología , Ingeniería de Tejidos , Fenómenos Biomecánicos , Bioprótesis , Recuento de Células , Diferenciación Celular , Supervivencia Celular , Células Cultivadas , Matriz Extracelular/metabolismo , Células Madre Fetales/metabolismo , Prótesis Valvulares Cardíacas , Humanos , Fenotipo , Trasplante Autólogo
17.
Eur J Cardiothorac Surg ; 33(4): 583-9, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18255306

RESUMEN

INTRODUCTION: Latest techniques enable positioning of devices into the coronary sinus (CS) for mitral valve (MV) annuloplasty. We evaluate the feasibility of non-invasive assessment to determine CS anatomy and its relation to MV annulus and coronary arteries by multi-slice CT (MSCT) in normal and insufficient MV. METHODS: Fifty patients (33 males, 17 females, age 67+/-11 years) were studied retrospectively by 64-MSCT scans for anatomical criteria regarding CS and its relation to MV annulus and circumflex artery (CX). We included 24 patients with severe mitral insufficiency and 26 with no MV disease. Diameter of MV, of proximal and distal ostium of CS, length and volume of CS, angle between anterior interventricular vein (AIV) and CS, caliber change of CX before, under/over and after CS were analysed. Different anatomical correlations were demonstrated: distance of MV annulus to CS, CX to CS. RESULTS: Diameter of proximal CS ostium was significantly larger in insufficient MV compared to normal MV (11+/-2.8 mm vs 9.9+/-2.5 mm; p<0.024). CS was significantly longer in patients with insufficient MV (125.4+/-17 mm vs 108.9+/-18 mm; p<0.003) with also significant differences in volume of CS (p<0.039). Significant difference in annulus diameter, 46.1+/-6mm (insufficient MV) versus 39.5+/-7.5 mm, p<0.004 was observed. Angle CS-AIV was 103.5+/-29 degrees (range 52 degrees -144 degrees ) in insufficient valves versus 118.2+/-24.5 degrees (range 73 degrees -166 degrees ) in normal valves with a tendency to higher angles in normal valves (p=0.06). Distance of MV annulus to CS measured 16+/-4.1/14.2+/-3.6 mm (insufficient/normal MV) without significant difference between groups. In 15 patients CX ran under CS. Eighty-four percent of these patients (13/15) show a decrease in CS caliber in the area of intersection. In 14 patients CS ran over and in one patient the diameter of the CS at intersecting region was smaller. In 16 patients no direct point of contact was visible, in five patients CX to CS positioning was not evaluable. CONCLUSION: There is a significant anatomic difference between normal and insufficient MV, which might be the basis for any interventional approaches through the CS. Exact measurements of all structures and its anatomic correlations are possible with MSCT, which allows pre-interventional planning.


Asunto(s)
Seno Coronario/anatomía & histología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/anatomía & histología , Tomografía Computarizada por Rayos X/métodos , Anciano , Seno Coronario/patología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Válvula Mitral/patología , Insuficiencia de la Válvula Mitral/patología , Estudios Retrospectivos
18.
Int J Cardiol ; 129(1): 141-3, 2008 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-17720264

RESUMEN

Sleep apnoea syndrome is frequent in patients with heart failure and associated with a worse prognosis. We evaluated a new device (Auricall) for non-invasive, continuous recording of oxygen saturation (SpO(2)) and heart rate (HR) in patients with heart failure. We studied 20 patients (mean age 48.43+/-14.4 years, NYHA class II-III). All patients were requested to carry the device for at least 36 h and to write a diary during the recording time. Satisfactory recording of SpO(2) and HR was possible to obtain in 18 of 20 patients. Indeed 9 out of 18 patients showed significant periodic changes in SpO(2) during sleep. Therefore, Auricall is a useful tool to non-invasively monitor SpO(2) and HR in patients with heart failure and to detect breathing disorders in these patients.


Asunto(s)
Insuficiencia Cardíaca/metabolismo , Frecuencia Cardíaca/fisiología , Monitoreo Ambulatorio/instrumentación , Monitoreo Ambulatorio/tendencias , Consumo de Oxígeno/fisiología , Adulto , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio/métodos , Oximetría/instrumentación , Oximetría/métodos , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/metabolismo
19.
J Card Surg ; 22(5): 406-9, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17803577

RESUMEN

INTRODUCTION: Surgical repair of the mitral valve is in most cases limited to the posterior leaflet of the mitral valve and to the annulus fibrosus. The term annulus fibrosus is still used in anatomical and clinical terminology and is described as a cord like structure providing the attachment of the mitral vale. However, to date no evidence exists of a ring-or cord-like structure at this area. Herein, we describe the attachment of the mitral valve by using the macroscopical and microscopical techniques. MATERIAL AND METHODS: The ventricular attachment of the posterior mitral valve leaflet was investigated in 10 human hearts. In dry dissected specimens, the intraventricular illumination was used to identify the attachment of the mitral valve to the left ventricular muscle. Using the histological techniques, we verified the position of the annulus fibrosus. RESULTS: The attachment of the posterior mitral valve leaflet is a band-like structure positioned between the left ventricular muscle and the left atrium. This fibrous band illustrates the morphological attachment of the mitral valve and, as thus, was interpreted as the annulus fibrosus of the mitral valve. CONCLUSION: Based on our data, no ring-like structure was found corresponding to the anatomical description of the annulus fibrosus, instead the band-like fibrous tissue was identified positioned between the mitral valve and the left ventricle. Histologicaly, we detected that this structure is part of the greater structural system that is directly connected to the membranous septum, to the left and right fibrous trigone and the attachment aortic root to the left ventricular muscle.


Asunto(s)
Proteínas de la Matriz Extracelular , Enfermedades de las Válvulas Cardíacas , Válvula Mitral/anatomía & histología , Adulto , Anciano , Cadáver , Humanos , Persona de Mediana Edad , Válvula Mitral/patología , Proyectos Piloto
20.
Circulation ; 116(11 Suppl): I64-70, 2007 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-17846327

RESUMEN

BACKGROUND: A novel concept providing prenatally tissue engineered human autologous heart valves based on routinely obtained fetal amniotic fluid progenitors as single cell source is introduced. METHODS AND RESULTS: Fetal human amniotic progenitors were isolated from routinely sampled amniotic fluid and sorted using CD133 magnetic beads. After expansion and differentiation, cell phenotypes of CD133- and CD133+ cells were analyzed by immunohistochemistry and flowcytometry. After characterization, CD133- derived cells were seeded onto heart valve leaflet scaffolds (n=18) fabricated from rapidly biodegradable polymers, conditioned in a pulse duplicator system, and subsequently coated with CD133+ derived cells. After in vitro maturation, opening and closing behavior of leaflets was investigated. Neo-tissues were analyzed by histology, immunohistochemistry, and scanning electron microscopy (SEM). Extracellular matrix (ECM) elements and cell numbers were quantified biochemically. Mechanical properties were assessed by tensile testing. CD133- derived cells demonstrated characteristics of mesenchymal progenitors expressing CD44 and CD105. Differentiated CD133+ cells showed features of functional endothelial cells by eNOS and CD141 expression. Engineered heart valve leaflets demonstrated endothelialized tissue formation with production of ECM elements (GAG 80%, HYP 5%, cell number 100% of native values). SEM showed intact endothelial surfaces. Opening and closing behavior was sufficient under half of systemic conditions. CONCLUSIONS: The use of amniotic fluid as single cell source is a promising low-risk approach enabling the prenatal fabrication of heart valves ready to use at birth. These living replacements with the potential of growth, remodeling, and regeneration may realize the early repair of congenital malformations.


Asunto(s)
Líquido Amniótico/citología , Bioprótesis , Prótesis Valvulares Cardíacas , Válvulas Cardíacas/citología , Células Madre/citología , Adulto , Líquido Amniótico/fisiología , Células Cultivadas , Femenino , Válvulas Cardíacas/fisiología , Humanos , Masculino , Embarazo , Células Madre/fisiología , Ingeniería de Tejidos/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA