Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Chromatogr A ; 1636: 461783, 2021 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-33340744

RESUMEN

New Psychoactive Substances (NPS) are quickly developing to evade legislation, posing unprecedented challenges to public health and law enforcement authorities around the world. The aim of this work was to develop and validate a simple and reliable non-target gas chromatography/mass spectrometry (GC/MS) analytical method based on linear retention indexes for the expeditious identification of NPS without the need of analytical standards. The method was optimized and validated for 22 different drugs covering ten categories: phenethylamines (amphetamine, MDMA, methamphetamine, 25CNBOMe, 2-FA, 5-MAPB), "classic" drugs (cocaine, ephedrine, THC, heroine), synthetic cannabinoids (JWH-081, AM-2201, JWH-210, MAM-2201), piperazines (o-CPP, p-CPP), tryptamines (5-MeO-MiPT), synthetic cathinones (N-ethylpentylone), synthetic opioids (U-47700), aminoindanes (5-IAI), plant-based substances (Salvinorin-A) and "other" (methiopropamine). Three figures of merit (Selectivity, Precision and Robustness) were evaluated with retention index confidence intervals ranging from 0.5 to 20.6 i.u. and relative standard deviations in the range of 0.003% to 0.027% (repeatability) and 0.02% to 0.29% (intermediate precision). A general equation for estimating linear retention index variation as a function of retention time tolerance has been derived. This result in combination with a 2III6-3 fractional factorial design allowed to conclude column polarity to be only statistically relevant factor as compared to gas flow, split ratio, injection temperature, temperature program offset and column brand.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas/métodos , Psicotrópicos/análisis , Analgésicos Opioides/análisis , Cannabinoides/análisis , Humanos , Modelos Teóricos , Fenetilaminas/análisis , Reproducibilidad de los Resultados
2.
Forensic Sci Int ; 290: 169-177, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30053736

RESUMEN

Cocaine use has been reported for more than 2500 years, but along this period of time its damage to society in general became evident. Nowadays, cocaine is classified as an illicit drug and studies which give support to drug enforcement institutions, particularly in the area of police intelligence, are very relevant. Often, trafficked cocaine is not traded in its pure form, but mixed with adulterants and diluents. In the analysis of seized samples, the reference method is based on gas chromatography, however the interest in the use of vibrational spectroscopy has increased. This work aims at developing a method for determination of the concentrations of cocaine, adulterants and diluents in cocaine samples employing Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FTIR) associated with Multivariate Curve Resolution with Alternating Least-Squares (MCR-ALS). A total of 6 adulterants, 3 diluents, 2 forms of cocaine (base and hydrochloride) were determined and the method developed based on 55 synthetic mixtures prepared according to a mixture design and 20 seized samples. For validation purposes 708 seized samples and 9 synthetic mixtures were analyzed. The results proved to be satisfactory, showing that the proposed method has a great potential in the classification of the chemical form of cocaine, identification of adulterants, diluents and cocaine in seized samples, as well as providing an estimate for their concentration.


Asunto(s)
Cocaína/química , Contaminación de Medicamentos , Drogas Ilícitas/química , Toxicología Forense/métodos , Humanos , Análisis de los Mínimos Cuadrados , Espectrofotometría Infrarroja
3.
Forensic Sci Int ; 257: 297-306, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26448534

RESUMEN

Middle infrared spectroscopy and multivariate analysis have been applied for the development of methods to perform both quantitative and qualitative analysis of real drug samples seized by the Brazilian Police Federal (BPF). Currently, quantification of cocaine and determination of adulterants in seizures is performed using gas chromatography with flame ionization detection. However, this technique requires a relatively complex sample preparation, higher time of analysis, the destruction of sample and a high cost. In this context, this paper presents a simpler method to quantify cocaine and its major adulterants in seized materials. Out of 375 seizures, taken within a time frame of 2009-2013. A total of 1085 samples were analyzed of which 500 were selected for the calibration set and 585 for the validation set. Cocaine concentration in seized samples was determined by using middle infrared spectroscopy and partial least squares regression (PLSR), obtaining an average prediction error of 3.0% (w/w), precision of 2.0 and 11.8% (w/w) of minimum detectable cocaine concentration in a range varying from 24.2 to 99.9% (w/w). Results indicate that the developed method is able to discriminate between cocaine hydrochloride and free base samples, to quantify cocaine content as well as to estimate the concentration of main adulterants phenacetin, benzocaine, caffeine, lidocaine and aminopyrine.


Asunto(s)
Cocaína/análisis , Contaminación de Medicamentos , Drogas Ilícitas/química , Análisis de los Mínimos Cuadrados , Espectrofotometría Infrarroja , Brasil , Tráfico de Drogas , Humanos
4.
Anal Chim Acta ; 860: 15-22, 2015 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-25682242

RESUMEN

The aim of this study was to develop a methodology using Raman hyperspectral imaging and chemometric methods for identification of pre- and post-blast explosive residues on banknote surfaces. The explosives studied were of military, commercial and propellant uses. After the acquisition of the hyperspectral imaging, independent component analysis (ICA) was applied to extract the pure spectra and the distribution of the corresponding image constituents. The performance of the methodology was evaluated by the explained variance and the lack of fit of the models, by comparing the ICA recovered spectra with the reference spectra using correlation coefficients and by the presence of rotational ambiguity in the ICA solutions. The methodology was applied to forensic samples to solve an automated teller machine explosion case. Independent component analysis proved to be a suitable method of resolving curves, achieving equivalent performance with the multivariate curve resolution with alternating least squares (MCR-ALS) method. At low concentrations, MCR-ALS presents some limitations, as it did not provide the correct solution. The detection limit of the methodology presented in this study was 50 µg cm(-2).

5.
Sci Justice ; 54(4): 300-6, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25002048

RESUMEN

Over the past six years the Brazilian Federal Police has undertaken major efforts in order to implement and to develop its own drug chemical profiling program. This paper aims to provide a broad perspective regarding the managerial strategies and some examples of subsequent technical issues involved in the implementation of such a project. Close collaboration with local drug enforcement and investigation teams, establishment of proper worldwide partnerships with well recognized institutions in the field of drug analysis and the attainment of suitable funding and human resources are shown to be key success factors. Some preliminary results concerning the chemical profile of cocaine seizures in Brazil during this process are presented.

6.
Anal Chem ; 85(4): 2457-64, 2013 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-23330818

RESUMEN

Cocaine sample correlation provides important information in the identification of traffic networks. However, available methods for estimating if samples are linked or not require the use of previous police investigation and forensic expert knowledge regarding the number of classes and provide thresholds that are both static and data set specific. In this paper, a novel unsupervised linkage threshold method (ULT) based on chemometric analysis is described and applied to the analysis of headspace gas chromatography mass spectrometry (HS-GC/MS) data of more than 250 real cocaine hydrochloride samples seized by Brazilian Federal Police. The method is capable of establishing linkage thresholds that do not require any prior information about the number of classes or distribution of the samples and can be dynamically updated as the data set changes. It is envisaged that the ULT method may also be applied to other forensic expertise areas where limited population knowledge is available and data sets are continually modified with the inflow of new information.


Asunto(s)
Cocaína/química , Residuos de Medicamentos/análisis , Cromatografía de Gases y Espectrometría de Masas , Solventes/química , Brasil , Ciencias Forenses
7.
Forensic Sci Int ; 221(1-3): 113-9, 2012 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-22571827

RESUMEN

Recent information from various sources suggests that a new illicit drug, called "oxi", is being spread across Brazil. It would be used in the smoked form and it would look like to crack cocaine: usually small yellowish or light brown stones. As fully released in the media, "oxi" would differ from crack cocaine in the sense that crack would contain carbonate or bicarbonate salts whereas "oxi" would include the addition of calcium oxide and kerosene (or gasoline). In this context, this work presents a chemical profiling comparative study between "oxi" street samples seized by the Civil Police of the State of Acre (CP/AC) and samples associated with both international and interstate drug trafficking seized by the Brazilian Federal Police in Acre (FP/AC). The outcome of this work assisted Brazilian authorities to stop inaccurate and alarmist releases on this issue. It may be of good use by the forensic community in order to better understand matters in their efforts to guide local law enforcement agencies in case such claims reach the international illicit market.

8.
J Agric Food Chem ; 58(17): 9407-12, 2010 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-20695638

RESUMEN

Direct-infusion electrospray ionization-mass spectrometry [ESI(+)-MS] of several milk powder samples, confiscated by the Brazilian Federal Police, showed ions accounting for sodiated and potassiated molecules of disaccharides (m/z 365 and 381) as well as trisaccharides (m/z 527 and 543), whereas monosaccharide ions were not detected. The trisaccharide ions were not detected in samples of genuine milk powder, raising the suspicion that their presence indicates adulteration by the addition of maltodextrin. In control samples, maltose and maltotriose were hydrolyzed by alpha-glucosidase and not beta-galactosidase, whereas lactose was resistant to alpha-glucosidase but was hydrolyzed with beta-galactosidase. Samples suspected of being adulterated behaved in the same fashion, confirming the presence of maltose and maltotriose or maltodextrin. Direct-infusion ESI-MS is shown therefore to provide rapid screening of milk powder for adulteration with maltodextrin, whereas its combination with selective enzymatic hydrolysis provides highly reliable confirmation for unambiguous results.


Asunto(s)
Leche/química , Polisacáridos/química , Espectrometría de Masa por Ionización de Electrospray/métodos , alfa-Glucosidasas/metabolismo , Animales , Hidrólisis
9.
Analyst ; 135(4): 745-50, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20309447

RESUMEN

Using easy ambient sonic-spray ionization mass spectrometry (EASI-MS), fast and non-destructive fingerprinting identification and aging of ballpoint pen ink writings have been performed directly from paper surfaces under ordinary ambient conditions. EASI-MS data obtained directly from the ink lines showed that pens from different brands provide typical ink chemical profiles. Accelerated ink aging has also been monitored by EASI-MS revealing contrasting degradation behaviors for six different common ink dyes. As demonstrated for Basic Violet 3, some dyes display a cascade of degradation products whose abundances increase linearly with time thus functioning as 'chemical clocks' for ink aging. Analysis of questionable documents has confirmed the ink aging capabilities of EASI-MS. The order of superimposition at a crossing point has also been determined by EASI-MS. For two superimposed ink lines, continuous EASI-MS analysis has also shown that the EASI spray is able to penetrate through the layers and therefore both ink layers could be characterized.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA