Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Viruses ; 15(2)2023 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-36851500

RESUMEN

Host range is a major determinant in the industrial utility of a bacteriophage. A model host range permits broad recognition across serovars of a target bacterium while avoiding cross-reactivity with commensal microbiota. Searching for a naturally occurring bacteriophage with ideal host ranges is challenging, time-consuming, and restrictive. To address this, SPTD1.NL, a previously published luciferase reporter bacteriophage for Salmonella, was used to investigate manipulation of host range through receptor-binding protein engineering. Similar to related members of the Ackermannviridae bacteriophage family, SPTD1.NL possessed a receptor-binding protein gene cluster encoding four tailspike proteins, TSP1-4. Investigation of the native gene cluster through chimeric proteins identified TSP3 as the tailspike protein responsible for Salmonella detection. Further analysis of chimeric phages revealed that TSP2 contributed off-target Citrobacter recognition, whereas TSP1 and TSP4 were not essential for activity against any known host. To improve the host range of SPTD1.NL, TSP1 and TSP2 were sequentially replaced with chimeric receptor-binding proteins targeting Salmonella. This engineered construct, called RBP-SPTD1-3, was a superior diagnostic reporter, sensitively detecting additional Salmonella serovars while also demonstrating improved specificity. For industrial applications, bacteriophages of the Ackermannviridae family are thus uniquely versatile and may be engineered with multiple chimeric receptor-binding proteins to achieve a custom-tailored host range.


Asunto(s)
Bacteriófagos , Caudovirales , Bacteriófagos/genética , Reacciones Cruzadas , Especificidad del Huésped , Ingeniería de Proteínas , Proteínas Recombinantes de Fusión/metabolismo
2.
Viruses ; 16(1)2023 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-38275943

RESUMEN

Engineered bacteriophages (phages) can be effective diagnostic reporters for detecting a variety of bacterial pathogens. Although a promising biotechnology, the large-scale use of these reporters may result in the unintentional release of genetically modified viruses. In order to limit the potential environmental impact, the ability of these phages to propagate outside the laboratory was targeted. The phage SEA1 has been previously engineered to facilitate food safety as an accurate and sensitive reporter for Salmonella contamination. In this study, homologous recombination was used to replace the expression of an essential baseplate wedge subunit (gp141) in SEA1 with a luciferase, NanoLuc®. This reporter, referred to as SEA1Δgp141.NL, demonstrated a loss of plaque formation and a failure to increase in titer following infection of Salmonella. SEA1Δgp141.NL was thus incapable of producing infectious progeny in the absence of gp141. In contrast, production of high titer stocks was possible when gp141 was artificially supplied in trans during infection. As a reporter, SEA1Δgp141.NL facilitated rapid, sensitive, and robust detection of Salmonella despite an inability to replicate. These results suggest that replication-deficient reporter phages are an effective method to obtain improved containment without sacrificing significant performance or the ease of production associated with many phage-based diagnostic methods.


Asunto(s)
Bacteriófagos , Bacteriófagos/genética , Salmonella/genética , Bacterias
3.
Viruses ; 14(8)2022 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-36016370

RESUMEN

Bacteriophages have been investigated for clinical utility, both as diagnostic tools and as therapeutic interventions. In order to be applied successfully, a detailed understanding of the influence of the human matrix on the interaction between bacteriophage and the host bacterium is required. In this study, a cocktail of luciferase bacteriophage reporters was assessed for functionality in a matrix containing human serum and spiked with Staphylococcus aureus. The inhibition of signal and loss of sensitivity was evident with minimal amounts of serum. This phenotype was independent of bacterial growth and bacteriophage viability. Serum-mediated loss of signal was common, albeit not universal, among S. aureus strains. Immunoglobulin G was identified as an inhibitory component and partial inhibition was observed with both the f(ab')2 and Fc region. A modified bacteriophage cocktail containing recombinant protein A was developed, which substantially improved signal without the need for additional sample purification. This study highlights the importance of assessing bacteriophage activity in relevant host matrices. Furthermore, it identifies an effective solution, recombinant protein A, for promoting bacteriophage-based detection of S. aureus in matrices containing human serum.


Asunto(s)
Bacteriófagos , Infecciones Estafilocócicas , Bacteriófagos/fisiología , Humanos , Inmunoglobulina G , Proteínas Recombinantes/genética , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/terapia , Staphylococcus aureus
4.
J AOAC Int ; 104(6): 1609-1619, 2021 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-33734389

RESUMEN

BACKGROUND: The PhageDx™ Listeria Assay is a simple, specific, and sensitive assay based on the infection of Listeria spp. by selected bacteriophages and the resultant expression of a luciferase reporter gene. Results are generated in as little as 24.5 h for stainless steel and ceramic environmental surfaces. OBJECTIVE: An AOAC Performance Tested MethodsSM (PTM) study was conducted to validate the PhageDx Listeria Assay for the detection of Listeria on stainless steel and ceramic surfaces. METHOD: The performance of the PhageDx method was compared to that of the U.S. Food and Drug Administration (FDA) Bacterial Analytical Manual (BAM) Ch. 10. Inclusivity/exclusivity, product consistency and stability, and robustness testing also were conducted. RESULTS: Inclusivity testing demonstrated that the reporter bacteriophages were specific for Listeria ssp. and detected 58/61 Listeria strains tested, including all 34 L. monocytogenes strains. The reporter bacteriophage also was shown to not detect 46/47 non-Listeria bacteria in exclusivity testing. Robustness testing showed that the method performed well with specific deviations from the standard protocol. Consistency and stability testing demonstrated that the recombinant phage gave consistent results across three production lots and was stable when stored under appropriate conditions for at least 6 months. Matrix studies on stainless steel and ceramic surfaces showed that there was no significant difference between the PhageDx Listeria Assay and the FDA/BAM Chapter 10 reference method. CONCLUSIONS AND HIGHLIGHTS: The validation study demonstrates that the PhageDx Listeria Assay is an effective method for the detection of Listeria spp. on stainless steel and ceramic environmental surfaces and meets the qualifications for AOAC PTM status.


Asunto(s)
Listeria , Técnicas Bacteriológicas , Cerámica , Microbiología de Alimentos , Listeria/genética , Acero Inoxidable
5.
Viruses ; 12(6)2020 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-32545159

RESUMEN

Engineered luciferase reporter bacteriophages provide specific, sensitive, rapid and low-cost detection of target bacteria and address growing diagnostic needs in multiple industries. Detection of methicillin-resistant Staphylococcus aureus (MRSA) nasal colonization and antibiotic susceptibility play a critical supportive role in preventing hospital-acquired infections and facilitating antibiotic stewardship. We describe the development and evaluation of a novel phage-based MRSA diagnostic screen for nasal swab specimens. The screen utilizes two luciferase reporter phages capable of recognizing genetically-diverse Staphylococcus aureus. The beta-lactam antibiotic cefoxitin is included to differentiate between resistant (MRSA) and susceptible organisms. The screen positively identified 97.7% of 390 clinical MRSA isolates at low bacterial concentrations. At higher inoculums, 93.5% of 123 clinical non-MRSA Staphylococcus aureus yielded appropriate negative results. Although cross-reactivity of the phage cocktail was observed with other staphylococcal and bacillus species, these false positives were absent under selective conditions. MRSA remained detectable in the presence of 38 distinct competing species and was accurately identified in 100% of 40 spiked nasal specimens. Thus, this six-hour screen sensitively detected MRSA both in vitro and in human nasal matrix.


Asunto(s)
Bacteriófagos/fisiología , Técnicas y Procedimientos Diagnósticos , Staphylococcus aureus Resistente a Meticilina/virología , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/microbiología , Bacteriófagos/genética , Técnicas y Procedimientos Diagnósticos/instrumentación , Genes Reporteros , Humanos , Luciferasas/genética , Luciferasas/metabolismo , Staphylococcus aureus Resistente a Meticilina/fisiología , Nariz/microbiología , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA