Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 216
Filtrar
1.
J Nucl Med ; 65(10): 1611-1618, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39168519

RESUMEN

Radiolabeled small-molecule DOTA-haptens can be combined with antitumor/anti-DOTA bispecific antibodies (BsAbs) for pretargeted radioimmunotherapy (PRIT). For optimized delivery of the theranostic γ- and ß-emitting isotope 177Lu with DOTA-based PRIT (DOTA-PRIT), bivalent Gemini (DOTA-Bn-thiourea-PEG4-thiourea-Bn-DOTA, aka (3,6,9,12-tetraoxatetradecane-1,14-diyl)bis(DOTA-benzyl thiourea)) was developed. Methods: Gemini was synthesized by linking 2 S-2-(4-isothiocyanatobenzyl)-DOTA molecules together via a 1,14-diamino-PEG4 linker. [177Lu]Lu-Gemini was prepared with no-carrier-added 177LuCl3 to a molar-specific activity of 123 GBq/µmol and radiochemical purity of more than 99%. The specificity of BsAb-177Lu-Gemini was verified in vitro. Subsequently, we evaluated biodistribution and whole-body clearance for [177Lu]Lu-Gemini and, for comparison, our gold-standard monovalent [177Lu]Lu-S-2-(4-aminobenzyl)-DOTA ([177Lu]Lu-DOTA-Bn) in naïve (tumor-free) athymic nude mice. For our proof-of-concept system, a 3-step pretargeting approach was performed with an established DOTA-PRIT regimen (anti-GPA33/anti-DOTA IgG-scFv BsAb, a clearing agent, and [177Lu]Lu-Gemini) in mouse models. Results: Initial in vivo studies showed that [177Lu]Lu-Gemini behaved similarly to [177Lu]Lu-DOTA-Bn, with almost identical blood and whole-body clearance kinetics, as well as biodistribution and mouse kidney dosimetry. Pretargeting [177Lu]Lu-Gemini to GPA33-expressing SW1222 human colorectal xenografts was highly effective, leading to absorbed doses of [177Lu]Lu-Gemini for blood, tumor, liver, spleen, and kidneys of 3.99, 455, 6.93, 5.36, and 14.0 cGy/MBq, respectively. Tumor-to-normal tissue absorbed-dose ratios (i.e., therapeutic indices [TIs]) for the blood and kidneys were 114 and 33, respectively. In addition, we demonstrate that the use of bivalent [177Lu]Lu-Gemini in DOTA-PRIT leads to improved TIs and augmented [177Lu]Lu-Gemini tumor uptake and retention in comparison to monovalent [177Lu]Lu-DOTA-Bn. Finally, we established efficacy in SW1222 tumor-bearing mice, demonstrating that a single injection of anti-GPA33 DOTA-PRIT with 44 MBq (1.2 mCi) of [177Lu]Lu-Gemini (estimated tumor-absorbed dose, 200 Gy) induced complete responses in 5 of 5 animals and a histologic cure in 2 of 5 (40%) animals. Moreover, a significant increase in survival compared with nontreated controls was noted (maximum tolerated dose not reached). Conclusion: We have developed a bivalent DOTA-radiohapten, [177Lu]Lu-Gemini, that showed improved radiopharmacology for DOTA-PRIT application. The use of bivalent [177Lu]Lu-Gemini in DOTA-PRIT, as opposed to monovalent [177Lu]Lu-DOTA-Bn, allows curative treatments with considerably less administered 177Lu activity while still achieving high TIs for both the blood (>100) and the kidneys (>30).


Asunto(s)
Neoplasias Colorrectales , Lutecio , Radioinmunoterapia , Radioisótopos , Radioinmunoterapia/métodos , Animales , Ratones , Humanos , Neoplasias Colorrectales/radioterapia , Neoplasias Colorrectales/diagnóstico por imagen , Radioisótopos/uso terapéutico , Radioisótopos/química , Distribución Tisular , Línea Celular Tumoral , Marcaje Isotópico , Nanomedicina Teranóstica/métodos , Radiofármacos/uso terapéutico , Radiofármacos/farmacocinética , Radiofármacos/química , Femenino , Compuestos Heterocíclicos con 1 Anillo/química , Glicoproteínas de Membrana
2.
J Nucl Med ; 65(9): 1364-1370, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39142829

RESUMEN

Diffuse intrinsic pontine glioma (DIPG) is a rare childhood malignancy with poor prognosis. There are no effective treatment options other than external beam therapy. We conducted a pilot, first-in-human study using 124I-omburtamab imaging and theranostics as a therapeutic approach using a localized convection-enhanced delivery (CED) technique for administering radiolabeled antibody. We report the detailed pharmacokinetics and dosimetry results of intratumoral delivery of 124I-omburtamab. Methods: Forty-five DIPG patients who received 9.0-370.7 MBq of 124I-omburtamab intratumorally via CED underwent serial brain and whole-body PET/CT imaging at 3-5 time points after injection within 4, 24-48, 72-96, 120-144, and 168-240 h from the end of infusion. Serial blood samples were obtained for kinetic analysis. Whole-body, blood, lesion, and normal-tissue activities were measured, kinetic parameters (uptake and clearance half-life times) estimated, and radiation-absorbed doses calculated using the OLINDA software program. Results: All patients showed prominent activity within the lesion that was retained over several days and was detectable up to the last time point of imaging, with a mean 124I residence time in the lesion of 24.9 h and dose equivalent of 353 ± 181 mSv/MBq. Whole-body doses were low, with a dose equivalent of 0.69 ± 0.28 mSv/MBq. Systemic distribution and activities in normal organs and blood were low. Radiation dose to blood was very low, with a mean value of 0.27 ± 0.21 mGy/MBq. Whole-body clearance was monoexponential with a mean biologic half-life of 62.7 h and an effective half-life of 37.9 h. Blood clearance was biexponential, with a mean biologic half-life of 22.2 h for the rapid α phase and 155 h for the slower ß phase. Conclusion: Intratumoral CED of 124I-omburtamab is a novel theranostics approach in DIPG. It allows for delivery of high radiation doses to the DIPG lesions, with high lesion activities and low systemic activities and high tumor-to-normal-tissue ratios and achieving a wide safety margin. Imaging of the actual therapeutic administration of 124I-omburtamab allows for direct estimation of the therapeutic lesion and normal-tissue-absorbed doses.


Asunto(s)
Neoplasias del Tronco Encefálico , Glioma Pontino Intrínseco Difuso , Radioisótopos de Yodo , Radiometría , Humanos , Masculino , Femenino , Niño , Neoplasias del Tronco Encefálico/diagnóstico por imagen , Neoplasias del Tronco Encefálico/radioterapia , Glioma Pontino Intrínseco Difuso/diagnóstico por imagen , Glioma Pontino Intrínseco Difuso/radioterapia , Preescolar , Adolescente , Convección , Tomografía Computarizada por Tomografía de Emisión de Positrones , Glioma/diagnóstico por imagen , Glioma/radioterapia , Distribución Tisular , Lactante , Adulto Joven
3.
J Nucl Med Technol ; 52(2): 74-85, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839128

RESUMEN

Internal dosimetry evaluates the amount and spatial and temporal distributions of radiation energy deposited in tissue from radionuclides within the body. Historically, nuclear medicine had been largely a diagnostic specialty, and the implicitly performed risk-benefit analyses have been straightforward, with relatively low administered activities yielding important diagnostic information whose benefit far outweighs any potential risk associated with the attendant normal-tissue radiation doses. Although dose estimates based on anatomic models and population-average kinetics in this setting may deviate rather significantly from the actual normal-organ doses for individual patients, the large benefit-to-risk ratios are very forgiving of any such inaccuracies. It is in this context that the MIRD schema was originally developed and has been largely applied. The MIRD schema, created and maintained by the MIRD committee of the Society of Nuclear Medicine and Molecular Imaging, comprises the notation, terminology, mathematic formulas, and reference data for calculating tissue radiation doses from radiopharmaceuticals administered to patients. However, with the ongoing development of new radiopharmaceuticals and the increasing therapeutic application of such agents, internal dosimetry in nuclear medicine and the MIRD schema continue to evolve-from population-average and organ-level to patient-specific and suborgan to voxel-level to cell-level dose estimation. This article will review the basic MIRD schema, relevant quantities and units, reference anatomic models, and its adaptation to small-scale and patient-specific dosimetry.


Asunto(s)
Radiometría , Radiofármacos , Humanos , Radiometría/métodos
4.
J Nucl Med ; 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38388514

RESUMEN

90Y-microsphere radioembolization has become a well-established treatment option for liver malignancies and is one of the first U.S. Food and Drug Administration-approved unsealed radionuclide brachytherapy devices to incorporate dosimetry-based treatment planning. Several different mathematical models are used to calculate the patient-specific prescribed activity of 90Y, namely, body surface area (SIR-Spheres only), MIRD single compartment, and MIRD dual compartment (partition). Under the auspices of the MIRDsoft initiative to develop community dosimetry software and tools, the body surface area, MIRD single-compartment, MIRD dual-compartment, and MIRD multicompartment models have been integrated into a MIRDy90 software worksheet. The worksheet was built in MS Excel to estimate and compare prescribed activities calculated via these respective models. The MIRDy90 software was validated against available tools for calculating 90Y prescribed activity. The results of MIRDy90 calculations were compared with those obtained from vendor and community-developed tools, and the calculations agreed well. The MIRDy90 worksheet was developed to provide a vetted tool to better evaluate patient-specific prescribed activities calculated via different models, as well as model influences with respect to varying input parameters. MIRDy90 allows users to interact and visualize the results of various parameter combinations. Variables, equations, and calculations are described in the MIRDy90 documentation and articulated in the MIRDy90 worksheet. The worksheet is distributed as a free tool to build expertise within the medical physics community and create a vetted standard for model and variable management.

5.
Mol Imaging Biol ; 26(1): 17-28, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37964036

RESUMEN

Preclinical dosimetry is essential for guiding the design of animal radiopharmaceutical biodistribution, imaging, and therapy experiments, evaluating efficacy and/or toxicities in such experiments, ensuring compliance with ethical standards for animal research, and, perhaps most importantly, providing reasonable initial estimates of normal-organ doses in humans, required for clinical translation of new radiopharmaceuticals. This MIB Guide provides a basic protocol for obtaining preclinical dosimetry estimates with organ-level dosimetry software.


Asunto(s)
Radiometría , Radiofármacos , Animales , Humanos , Radiofármacos/uso terapéutico , Distribución Tisular , Radiometría/métodos , Diagnóstico por Imagen , Programas Informáticos
6.
Biomedicines ; 11(10)2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37892973

RESUMEN

Drugs with a long residence time at their target sites are often more efficacious in disease treatment. The mechanism, however, behind prolonged retention at the site of action is often difficult to understand for non-covalent agents. In this context, we focus on epichaperome agents, such as zelavespib and icapamespib, which maintain target binding for days despite rapid plasma clearance, minimal retention in non-diseased tissues, and rapid metabolism. They have shown significant therapeutic value in cancer and neurodegenerative diseases by disassembling epichaperomes, which are assemblies of tightly bound chaperones and other factors that serve as scaffolding platforms to pathologically rewire protein-protein interactions. To investigate their impact on epichaperomes in vivo, we conducted pharmacokinetic and target occupancy measurements for zelavespib and monitored epichaperome assemblies biochemically in a mouse model. Our findings provide evidence of the intricate mechanism through which zelavespib modulates epichaperomes in vivo. Initially, zelavespib becomes trapped when epichaperomes bound, a mechanism that results in epichaperome disassembly, with no change in the expression level of epichaperome constituents. We propose that the initial trapping stage of epichaperomes is a main contributing factor to the extended on-target residence time observed for this agent in clinical settings. Zelavespib's residence time in tumors seems to be dictated by target disassembly kinetics rather than by frank drug-target unbinding kinetics. The off-rate of zelavespib from epichaperomes is, therefore, much slower than anticipated from the recorded tumor pharmacokinetic profile or as determined in vitro using diluted systems. This research sheds light on the underlying processes that make epichaperome agents effective in the treatment of certain diseases.

7.
Methods Cell Biol ; 180: 93-111, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37890935

RESUMEN

Radiopharmaceutical therapy is a rapidly growing field for the treatment of cancer due to its high specificity and ability to target individual affected cells. A key component of the pre-clinical development of a new therapeutic radiopharmaceutical is the determination of its time-dependent distribution in tumors, normal tissues, and the whole body in mouse tumor models. Here, we provide an overview of the available instrumentation for the novice in radiation measurement. We also detail the methodology for assessing distribution and kinetics of a radiopharmaceutical and calculating radiation absorbed dose in mice using a gamma counter or a PET or SPECT camera.


Asunto(s)
Neoplasias , Radiofármacos , Ratones , Animales , Radiometría/métodos , Distribución Tisular
8.
Med Phys ; 50(12): 7390-7399, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37656137

RESUMEN

BACKGROUND: Potential risk associated with low-dose radiation exposures is often expressed using the effective dose (E) quantity. Other risk-related quantities have been proposed as alternatives. The recently introduced risk index (RI) shares similarities with E but expands the metric to incorporate medical imaging-appropriate risks factors including patient-specific size, age, and sex. PURPOSE: The aim of this work is to examine the RI metric for quantifying stochastic radiation risk and demonstrate its applications in nuclear imaging. The advantages in this improved metric may help the field progress toward stratified risk consideration in the course of patient management, improve efforts for procedure optimization, and support an evolution in the science of radiation risk assessment. METHODS: In this study we describe, implement, and calculate RI for various diagnostic nuclear imaging scenarios using reference biokinetics published in ICRP Publication 128 for commonly utilized radiopharmaceuticals. All absorbed dose, E and RI calculations were performed using the freely available MIRDcalc nuclear medicine dosimetry software; the organ specific risk parameters used in the software are also benchmarked in this text. The resulting RI and E values are compared and various trends in RI values identified. RESULTS: E and RI coefficients were calculated for 3016 use cases. Notably RI values vary depending on patient characteristics. Overall, across the population, global trends in RI values can be identified. In general, RI values were 2.15 times higher for females than males, due to higher risk coefficients and activities being distributed in smaller reference masses. The pediatric patients showed higher RIs than adults, as younger patients generally receive higher absorbed doses per administered activity, and are more radiosensitive, and have a longer projected lifespan at risk. A compendium of E and RI values is also provided in table format to serve as a reference for the community. CONCLUSIONS: RI is a rational quantity that could be used for justification, risk communication and protocol optimization in medical imaging. It has some advantages when compared to the long-utilized E value with respect to personalization, since accounts for patient size, age, sex, and natural incidence of cancer risk.


Asunto(s)
Radiometría , Radiofármacos , Masculino , Adulto , Femenino , Humanos , Niño , Dosis de Radiación , Radiometría/métodos , Programas Informáticos , Radiografía , Fantasmas de Imagen
9.
Res Sq ; 2023 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-37645915

RESUMEN

Preclinical dosimetry is essential for guiding the design of animal radiopharmaceutical biodistribution, imaging, and therapy experiments, evaluating efficacy and/or toxicities in such experiments, ensuring compliance with ethical standards for animal research, and providing reasonable initial estimates of normal-organ doses in humans, required for clinical translation of new radiopharmaceuticals. This MIB guide provides a basic protocol for obtaining preclinical dosimetry estimates with organ-level dosimetry software.

10.
J Nucl Med ; 64(9): 1439-1445, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37348919

RESUMEN

Epithelial ovarian cancer (EOC) is often asymptomatic and presents clinically in an advanced stage as widespread peritoneal microscopic disease that is generally considered to be surgically incurable. Targeted α-therapy with the α-particle-emitting radionuclide 225Ac (half-life, 9.92 d) is a high-linear-energy-transfer treatment approach effective for small-volume disease and even single cells. Here, we report the use of human epidermal growth factor receptor 2 (HER2) 225Ac-pretargeted radioimmunotherapy (PRIT) to treat a mouse model of human EOC SKOV3 xenografts growing as peritoneal carcinomatosis (PC). Methods: On day 0, 105 SKOV3 cells transduced with a luciferase reporter gene were implanted intraperitoneally in nude mice, and tumor engraftment was verified by bioluminescent imaging (BLI). On day 15, treatment was started using 1 or 2 cycles of 3-step anti-HER2 225Ac-PRIT (37 kBq/cycle as 225Ac-Proteus DOTA), separated by a 1-wk interval. Efficacy and toxicity were monitored for up to 154 d. Results: Untreated PC-tumor-bearing nude mice showed a median survival of 112 d. We used 2 independent measures of response to evaluate the efficacy of 225Ac-PRIT. First, a greater proportion of the treated mice (9/10 1-cycle and 8/10 2-cycle; total, 17/20; 85%) survived long-term compared with controls (9/27, 33%), and significantly prolonged survival was documented (log-rank [Mantel-Cox] P = 0.0042). Second, using BLI, a significant difference in the integrated BLI signal area to 98 d was noted between controls and treated groups (P = 0.0354). Of a total of 8 mice from the 2-cycle treatment group (74 kBq total) that were evaluated by necropsy, kidney radiotoxicity was mild and did not manifest itself clinically (normal serum blood urea nitrogen and creatinine). Dosimetry estimates (relative biological effectiveness-weighted dose, where relative biological effectiveness = 5) per 37 kBq administered for tumors and kidneys were 56.9 and 16.1 Gy, respectively. One-cycle and 2-cycle treatments were equally effective. With immunohistology, mild tubular changes attributable to α-toxicity were observed in both therapeutic groups. Conclusion: Treatment of EOC PC-tumor-bearing mice with anti-HER2 225Ac-PRIT resulted in histologic cures and prolonged survival with minimal toxicity. Targeted α-therapy using the anti-HER2 225Ac-PRIT system is a potential treatment for otherwise incurable EOC.


Asunto(s)
Neoplasias Peritoneales , Radioinmunoterapia , Humanos , Animales , Ratones , Radioinmunoterapia/métodos , Ratones Desnudos , Neoplasias Peritoneales/diagnóstico por imagen , Neoplasias Peritoneales/radioterapia , Neoplasias Peritoneales/tratamiento farmacológico , Radioisótopos/uso terapéutico , Línea Celular Tumoral
11.
J Vasc Interv Radiol ; 34(9): 1556-1564.e4, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37201655

RESUMEN

PURPOSE: To evaluate the yttrium-90 (90Y) activity distribution in biopsy tissue samples of the treated liver to quantify the dose with higher spatial resolution than positron emission tomography (PET) for accurate investigation of correlations with microscopic biological effects and to evaluate the radiation safety of this procedure. MATERIALS AND METHODS: Eighty-six core biopsy specimens were obtained from 18 colorectal liver metastases (CLMs) immediately after 90Y transarterial radioembolization (TARE) with either resin or glass microspheres using real-time 90Y PET/CT guidance in 17 patients. A high-resolution micro-computed tomography (micro-CT) scanner was used to image the microspheres in part of the specimens and allow quantification of 90Y activity directly or by calibrating autoradiography (ARG) images. The mean doses to the specimens were derived from the measured specimens' activity concentrations and from the PET/CT scan at the location of the biopsy needle tip for all cases. Staff exposures were monitored. RESULTS: The mean measured 90Y activity concentration in the CLM specimens at time of infusion was 2.4 ± 4.0 MBq/mL. The biopsies revealed higher activity heterogeneity than PET. Radiation exposure to the interventional radiologists during post-TARE biopsy procedures was minimal. CONCLUSIONS: Counting the microspheres and measuring the activity in biopsy specimens obtained after TARE are safe and feasible and can be used to determine the administered activity and its distribution in the treated and biopsied liver tissue with high spatial resolution. Complementing 90Y PET/CT imaging with this approach promises to yield more accurate direct correlation of histopathological changes and absorbed dose in the examined specimens.


Asunto(s)
Neoplasias Colorrectales , Embolización Terapéutica , Neoplasias Hepáticas , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Microtomografía por Rayos X , Autorradiografía , Tomografía de Emisión de Positrones/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamiento farmacológico , Radioisótopos de Itrio/efectos adversos , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/métodos , Biopsia Guiada por Imagen , Microesferas
12.
Adv Ther (Weinh) ; 6(3)2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37007587

RESUMEN

Despite advances by recently approved antibody-drug conjugates in treating advanced gastric cancer patients, substantial limitations remain. Here, several key obstacles are overcome by developing a first-in-class ultrasmall (sub-8-nanometer (nm)) anti-human epidermal growth factor receptor 2 (HER2)-targeting drug-immune conjugate nanoparticle therapy. This multivalent fluorescent core-shell silica nanoparticle bears multiple anti-HER2 single-chain variable fragments (scFv), topoisomerase inhibitors, and deferoxamine moieties. Most surprisingly, drawing upon its favorable physicochemical, pharmacokinetic, clearance, and target-specific dual-modality imaging properties in a "hit and run" approach, this conjugate eradicated HER2-expressing gastric tumors without any evidence of tumor regrowth, while exhibiting a wide therapeutic index. Therapeutic response mechanisms are accompanied by the activation of functional markers, as well as pathway-specific inhibition. Results highlight the potential clinical utility of this molecularly engineered particle drug-immune conjugate and underscore the versatility of the base platform as a carrier for conjugating an array of other immune products and payloads.

14.
J Neurooncol ; 162(1): 69-78, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36853490

RESUMEN

PURPOSE: Intraventricular compartmental radioimmunotherapy (cRIT) with 131-I-omburtamab is a potential therapy for recurrent primary brain tumors that can seed the thecal space. These patients often previously received external beam radiotherapy (EBRT) to a portion or full craniospinal axis (CSI) as part of upfront therapy. Little is known regarding outcomes after re-irradiation as part of multimodality therapy including cRIT. This study evaluates predictors of response, patterns of failure, and radiologic events after cRIT. METHODS: Patients with recurrent medulloblastoma or ependymoma who received 131-I-omburtamab on a prospective clinical trial were included. Extent of disease at cRIT initiation (no evidence of disease [NED] vs measurable disease [MD]) was assessed as associated with progression-free (PFS) and overall survival (OS) by Kaplan-Meier analysis. RESULTS: All 27 patients (20 medulloblastoma, 7 ependymoma) had EBRT preceding cRIT: most (22, 81%) included CSI (median dose 2340 cGy, boost to 5400 cGy). Twelve (44%) also received EBRT at relapse as bridging to cRIT. There were no cases of radionecrosis. At cRIT initiation, 11 (55%) medulloblastoma and 3 (43%) ependymoma patients were NED, associated with improved PFS (p = 0.002) and OS (p = 0.048) in medulloblastoma. Most relapses were multifocal. With medium follow-up of 3.0 years (95% confidence interval, 1.8-7.4), 6 patients remain alive with NED. CONCLUSION: For patients with medulloblastoma, remission at time of cRIT was associated with significantly improved survival outcomes. Relapses are often multifocal, particularly in the setting of measurable disease at cRIT initiation. EBRT is a promising tool to achieve NED status at cRIT initiation, with no cases of radiation necrosis.


Asunto(s)
Neoplasias Encefálicas , Neoplasias Cerebelosas , Ependimoma , Meduloblastoma , Humanos , Anticuerpos Monoclonales/uso terapéutico , Neoplasias Encefálicas/radioterapia , Neoplasias Cerebelosas/radioterapia , Enfermedad Crónica , Ependimoma/radioterapia , Radioisótopos de Yodo/uso terapéutico , Meduloblastoma/terapia , Recurrencia Local de Neoplasia/radioterapia , Estudios Prospectivos , Dosificación Radioterapéutica
15.
J Nucl Med ; 64(6): 946-950, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36759197

RESUMEN

Radiolabeled antibody treatment with 131I-omburtamab, administered intraventricularly into the cerebrospinal fluid (CSF) space, can deliver therapeutic absorbed doses to sites of leptomeningeal disease. Assessment of distribution and radiation dosimetry is a key element in optimizing such treatments. Using a theranostic approach, we performed pretreatment 131I-omburtamab imaging and dosimetric analysis in patients before therapy. Methods: Whole-body planar images were acquired 3 ± 1, 23 ± 2, and 47 ± 2 h after intracranioventricular administration of 75 ± 5 MBq of 131I-omburtamab via an Ommaya reservoir. Multiple blood samples were also obtained for kinetic analysis. Separate regions of interest (ROIs) were manually drawn to include the lateral ventricles, entire spinal canal CSF space, and over the whole body. Count data in the ROIs were corrected for background and physical decay, converted to activity, and subsequently fitted to an exponential clearance function. The radiation absorbed dose was estimated to the CSF, separately to the spinal column and ventricles, and to the whole body and blood. Biodistribution of the injected radiolabeled antibody was assessed for all patients. Results: Ninety-five patients were included in the analysis. Biodistribution showed prompt localization in the ventricles and spinal CSF space with low systemic distribution, noted primarily as hepatic, renal, and bladder activity after the first day. Using ROI analysis, the effective half-lives were 13 ± 11 h (range, 5-75 h) for CSF in the spinal column, 8 ± 3 h (range, 3-17 h) for ventricles, and 41 ± 11 (range, 23-81 h) for the whole body. Mean absorbed doses were 0.63 ± 0.38 cGy/MBq (range, 0.24-2.25 cGy/MBq) for CSF in the spinal column, 1.03 ± 0.69 cGy/MBq (range, 0.27-5.15 cGy/MBq) for the ventricular CSF, and 0.45 ± 0.32 mGy/MBq (range, 0.05-1.43 mGy/MBq) for the whole body. Conclusion: Pretherapeutic imaging with 131I-omburtamab allows assessment of biodistribution and dosimetry before the administration of therapeutic activity. Absorbed doses to the CSF compartments and whole body derived from the widely applicable serial 131I-omburtamab planar images had acceptable agreement with previously reported data determined from serial 124I-omburtamab PET scans.


Asunto(s)
Radioinmunodetección , Radiometría , Humanos , Cinética , Distribución Tisular , Radiometría/métodos , Anticuerpos Monoclonales/uso terapéutico
17.
J Hematol Oncol ; 15(1): 165, 2022 11 12.
Artículo en Inglés | MEDLINE | ID: mdl-36371226

RESUMEN

BACKGROUND: The prognosis for metastatic and recurrent tumors of the central nervous system (CNS) remains dismal, and the need for newer therapeutic targets and modalities is critical. The cell surface glycoprotein B7H3 is expressed on a range of solid tumors with a restricted expression on normal tissues. We hypothesized that compartmental radioimmunotherapy (cRIT) with the anti-B7H3 murine monoclonal antibody omburtamab injected intraventricularly could safely target CNS malignancies. PATIENTS AND METHODS: We conducted a phase I trial of intraventricular 131I-omburtamab using a standard 3 + 3 design. Eligibility criteria included adequate cerebrospinal fluid (CSF) flow, no major organ toxicity, and for patients > dose level 6, availability of autologous stem cells. Patients initially received 74 MBq radioiodinated omburtamab to evaluate dosimetry and biodistribution followed by therapeutic 131I-omburtamab dose-escalated from 370 to 2960 MBq. Patients were monitored clinically and biochemically for toxicity graded using CTCAEv 3.0. Dosimetry was evaluated using serial CSF and blood sampling, and serial PET or gamma-camera scans. Patients could receive a second cycle in the absence of grade 3/4 non-hematologic toxicity or progressive disease. RESULTS: Thirty-eight patients received 100 radioiodinated omburtamab injections. Diagnoses included metastatic neuroblastoma (n = 16) and other B7H3-expressing solid tumors (n = 22). Thirty-five patients received at least 1 cycle of treatment with both dosimetry and therapy doses. Acute toxicities included < grade 4 self-limited headache, vomiting or fever, and biochemical abnormalities. Grade 3/4 thrombocytopenia was the most common hematologic toxicity. Recommended phase 2 dose was 1850 MBq/injection. The median radiation dose to the CSF and blood by sampling was 1.01 and 0.04 mGy/MBq, respectively, showing a consistently high therapeutic advantage for CSF. Major organ exposure was well below maximum tolerated levels. In patients developing antidrug antibodies, blood clearance, and therefore therapeutic index, was significantly increased. In patients receiving cRIT for neuroblastoma, survival was markedly increased (median PFS 7.5 years) compared to historical data. CONCLUSIONS: cRIT with 131I-omburtamab is safe, has favorable dosimetry and may have a therapeutic benefit as adjuvant therapy for B7-H3-expressing leptomeningeal metastases. TRIAL REGISTRATION: clinicaltrials.gov NCT00089245, August 5, 2004.


Asunto(s)
Neoplasias del Sistema Nervioso Central , Neuroblastoma , Humanos , Animales , Ratones , Distribución Tisular , Recurrencia Local de Neoplasia/tratamiento farmacológico , Anticuerpos Monoclonales/efectos adversos , Neoplasias del Sistema Nervioso Central/radioterapia , Neuroblastoma/radioterapia , Antígenos B7
18.
J Nucl Med ; 63(10): 1467-1474, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36192334

RESUMEN

The application of radiopharmaceutical therapy for the treatment of certain diseases is well established, and the field is expanding. New therapeutic radiopharmaceuticals have been developed in recent years, and more are in the research pipeline. Concurrently, there is growing interest in the use of internal dosimetry as a means of personalizing, and potentially optimizing, such therapy for patients. Internal dosimetry is multifaceted, and the current state of the art is discussed in this continuing education article. Topics include the context of dosimetry, internal dosimetry methods, the advantages and disadvantages of incorporating dosimetry calculations in radiopharmaceutical therapy, a description of the workflow for implementing patient-specific dosimetry, and future prospects in the field.


Asunto(s)
Radiometría , Radiofármacos , Humanos , Radiometría/métodos , Radiofármacos/uso terapéutico
19.
Clin Cancer Res ; 28(13): 2938-2952, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35499557

RESUMEN

PURPOSE: Despite dramatic growth in the number of small-molecule drugs developed to treat solid tumors, durable therapeutic options to control primary central nervous system malignancies are relatively scarce. Chemotherapeutic agents that appear biologically potent in model systems have often been found to be marginally effective at best when given systemically in clinical trials. This work presents for the first time an ultrasmall (<8 nm) multimodal core-shell silica nanoparticle, Cornell prime dots (or C' dots), for the efficacious treatment of high-grade gliomas. EXPERIMENTAL DESIGN: This work presents first-in-kind renally clearable ultrasmall (<8 nm) multimodal C' dots with surface-conjugated doxorubicin (DOX) via pH-sensitive linkers for the efficacious treatment in two different clinically relevant high-grade glioma models. RESULTS: Optimal drug-per-particle ratios of as-developed nanoparticle-drug conjugates were established and used to obtain favorable pharmacokinetic profiles. The in vivo efficacy results showed significantly improved biological, therapeutic, and toxicological properties over the native drug after intravenous administration in platelet-derived growth factor-driven genetically engineered mouse model, and an EGF-expressing patient-derived xenograft (EGFR PDX) model. CONCLUSIONS: Ultrasmall C' dot-drug conjugates showed great translational potential over DOX for improving the therapeutic outcome of patients with high-grade gliomas, even without a cancer-targeting moiety.


Asunto(s)
Glioma , Nanopartículas , Animales , Línea Celular Tumoral , Doxorrubicina , Sistemas de Liberación de Medicamentos/métodos , Glioma/tratamiento farmacológico , Humanos , Ratones , Dióxido de Silicio , Índice Terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA