Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Opt Lett ; 47(19): 4865-4868, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-36181136

RESUMEN

We demonstrate a method to image an object using a self-probing approach based on semiconductor high-harmonic generation. On the one hand, ptychography enables high-resolution imaging from the coherent light diffracted by an object. On the other hand, high-harmonic generation from crystals is emerging as a new source of extreme-ultraviolet ultrafast coherent light. We combine these two techniques by performing ptychography measurements with nanopatterned crystals serving as the object as well as the generation medium of the harmonics. We demonstrate that this strong field in situ approach can provide structural information about an object. With the future developments of crystal high harmonics as a compact short-wavelength light source, our demonstration can be an innovative approach for nanoscale imaging of photonic and electronic devices in research and industry.

2.
Front Oncol ; 11: 554668, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34113554

RESUMEN

Characterizing nanoparticles (NPs) distribution in multiple and complex metastases is of fundamental relevance for the development of radiological protocols based on NPs administration. In the literature, there have been advances in monitoring NPs in tissues. However, the lack of 3D information is still an issue. X-ray phase-contrast tomography (XPCT) is a 3D label-free, non-invasive and multi-scale approach allowing imaging anatomical details with high spatial and contrast resolutions. Here an XPCT qualitative study on NPs distribution in a mouse brain model of melanoma metastases injected with gadolinium-based NPs for theranostics is presented. For the first time, XPCT images show the NPs uptake at micrometer resolution over the full brain. Our results revealed a heterogeneous distribution of the NPs inside the melanoma metastases, bridging the gap in spatial resolution between magnetic resonance imaging and histology. Our findings demonstrated that XPCT is a reliable technique for NPs detection and can be considered as an emerging method for the study of NPs distribution in organs.

3.
Sensors (Basel) ; 21(3)2021 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-33525501

RESUMEN

For more than 15 years, Imagine Optic have developed Extreme Ultra Violet (EUV) and X-ray Hartmann wavefront sensors for metrology and imaging applications. These sensors are compatible with a wide range of X-ray sources: from synchrotrons, Free Electron Lasers, laser-driven betatron and plasma-based EUV lasers to High Harmonic Generation. In this paper, we first describe the principle of a Hartmann sensor and give some key parameters to design a high-performance sensor. We also present different applications from metrology (for manual or automatic alignment of optics), to soft X-ray source optimization and X-ray imaging.

4.
Sensors (Basel) ; 20(22)2020 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-33182797

RESUMEN

Wavefront analysis is a fast and reliable technique for the alignment and characterization of optics in the visible, but also in the extreme ultraviolet (EUV) and X-ray regions. However, the technique poses a number of challenges when used for optical systems with numerical apertures (NA) > 0.1. A high-numerical-aperture Hartmann wavefront sensor was employed at the free electron laser FLASH for the characterization of a Schwarzschild objective. These are widely used in EUV to achieve very small foci, particularly for photolithography. For this purpose, Schwarzschild objectives require highly precise alignment. The phase measurements acquired with the wavefront sensor were analyzed employing two different methods, namely, the classical calculation of centroid positions and Fourier demodulation. Results from both approaches agree in terms of wavefront maps with negligible degree of discrepancy.

5.
Sensors (Basel) ; 20(22)2020 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-33198428

RESUMEN

The Hartmann wavefront sensor is able to measure, separately and in absolute, the real δ and imaginary part ß of the X-ray refractive index. While combined with tomographic setup, the Hartman sensor opens many interesting opportunities behind the direct measurement of the material density. In order to handle the different ways of using an X-ray wavefront sensor in imaging, we developed a 3D wave propagation model based on Fresnel propagator. The model can manage any degree of spatial coherence of the source, thus enabling us to model experiments accurately using tabletop, synchrotron or X-ray free-electron lasers. Beam divergence is described in a physical manner consistent with the spatial coherence. Since the Hartmann sensor can detect phase and absorption variation with high sensitivity, a precise simulation tool is thus needed to optimize the experimental parameters. Examples are displayed.

6.
Sensors (Basel) ; 20(22)2020 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-33233576

RESUMEN

In recent years, integral imaging, a promising three-dimensional imaging technology, has attracted more and more attention for its broad applications in robotics, computational vision, and medical diagnostics. In the visible spectrum, an integral imaging system can be easily implemented by inserting a micro-lens array between a image formation optic and a pixelated detector. By using a micro-Fresnel Zone Plate (FZP) array instead of the refractive lens array, the integral imaging system can be applied in X-ray. Due to micro-scale dimensions of FZP in the array and current manufacturing techniques, the number of zones of FZP is limited. This may have an important impact on the FZP imaging performance. The paper introduces a simulation method based on the scalar diffraction theory. With the aid of this method, the effect of the number of zones on the FZP imaging performance is numerically investigated, especially the case of very small number of zones. Results of several simulation of FZP imaging are presented and show the image can be formed by a FZP with a number of zones as low as 5. The paper aims at offering a numerical approach in order to facilitate the design of FZP for integral imaging.

7.
Opt Lett ; 45(15): 4248-4251, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32735269

RESUMEN

We present a novel, to the best of our knowledge, Hartmann wave front sensor for extreme ultraviolet (EUV) spectral range with a numerical aperture (NA) of 0.15. The sensor has been calibrated using an EUV radiation source based on gas high harmonic generation. The calibration, together with simulation results, shows an accuracy beyond λ/39 root mean square (rms) at λ=32nm. The sensor is suitable for wave front measurement in the 10 nm to 45 nm spectral regime. This compact wave front sensor is high-vacuum compatible and designed for in situ operations, allowing wide applications for up-to-date EUV sources or high-NA EUV optics.

8.
Appl Opt ; 59(5): 1363-1370, 2020 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-32225398

RESUMEN

With high-harmonic generation (HHG), spatially and temporally coherent XUV to soft x-ray (100 nm to 10 nm) table-top sources can be realized by focusing a driving infrared (IR) laser on a gas target. For applications such as coherent diffraction imaging, holography, plasma diagnostics, or pump-probe experiments, it is desirable to have control over the wave front (WF) of the HHs to maximize the number of XUV photons on target or to tailor the WF. Here, we demonstrate control of the XUV WF by tailoring the driving IR WF with a deformable mirror. The WFs of both IR and XUV beams are monitored with WF sensors. We present a systematic study of the dependence of the aberrations of the HHs on the aberrations of the driving IR laser and explain the observations with propagation simulations. We show that we can control the astigmatism of the HHs by changing the astigmatism of the driving IR laser without compromising the HH generation efficiency with a WF quality from λ/8 to λ/13.3. This allows us to shape the XUV beam without changing any XUV optical element.

9.
RSC Adv ; 10(6): 3366-3370, 2020 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-35497736

RESUMEN

An efficient nano-sized delivery system is presented here allowing the immobilized, picolinium-tethered organic ligand to be released by X-ray irradiation. A marked difference was observed in the fragmentation efficiency by using conventional Cs-137 vs. pulsed sources.

10.
J Imaging ; 6(12)2020 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-34460535

RESUMEN

X-ray plenoptic cameras acquire multi-view X-ray transmission images in a single exposure (light-field). Their development is challenging: designs have appeared only recently, and they are still affected by important limitations. Concurrently, the lack of available real X-ray light-field data hinders dedicated algorithmic development. Here, we present a physical emulation setup for rapidly exploring the parameter space of both existing and conceptual camera designs. This will assist and accelerate the design of X-ray plenoptic imaging solutions, and provide a tool for generating unlimited real X-ray plenoptic data. We also demonstrate that X-ray light-fields allow for reconstructing sharp spatial structures in three-dimensions (3D) from single-shot data.

11.
Opt Lett ; 44(19): 4825-4828, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31568452

RESUMEN

A focused plenoptic camera has the ability to record and separate spatial and directional information of the incoming light. Combined with the appropriate algorithm, a 3D scene could be reconstructed from a single acquisition, over a depth range called plenoptic depth-of-field. In this Letter, we study the contrast variations with depth as a way to assess plenoptic depth-of-field. We take into account the impact of diffraction, defocus, and magnification on the resulting contrast. We measure the contrast directly on both simulated and acquired images. We demonstrate the importance of diffraction and magnification in the final contrast. Contrary to classical optics, the maximum of contrast is not centered around the main object plane, but around a shifted position, with a fast and nonsymmetric decrease of contrast.

12.
Opt Express ; 27(3): 2656-2670, 2019 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-30732300

RESUMEN

We perform wavefront measurements of high-order harmonics using an extreme-ultraviolet (XUV) Hartmann sensor and study how their spatial properties vary with different generation parameters, such as pressure in the nonlinear medium, fundamental pulse energy and duration as well as beam size. In some conditions, excellent wavefront quality (up to λ/11) was obtained. The high throughput of the intense XUV beamline at the Lund Laser Centre allows us to perform single-shot measurements of both the full harmonic beam generated in argon and individual harmonics selected by multilayer mirrors. We theoretically analyze the relationship between the spatial properties of the fundamental and those of the generated high-order harmonics, thus gaining insight into the fundamental mechanisms involved in high-order harmonic generation (HHG).

13.
Nanoscale ; 10(39): 18657-18664, 2018 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-30264838

RESUMEN

We report in this study the in vivo biodistribution of ultra-small luminescent gold (Au) particles (∼1.5 nm core size; 17 kDa), so-called nanoclusters (NCs), stabilized by bidentate zwitterionic molecules in subcutaneous (s.c.) and orthotopic glioblastoma mice models. Particular investigations on renal clearance and tumor uptake were performed using highly sensitive advanced imaging techniques such as multi-elemental Laser-Induced Breakdown Spectroscopy (LIBS) imaging and in-line X-ray Synchrotron Phase Contrast Tomography (XSPCT). Results show a blood circulation time of 6.5 ± 1.3 min accompanied by an efficient and fast renal clearance through the cortex of the kidney with a 66% drop between 1 h and 5 h. With a similar size range, these Au NCs are 5 times more fluorescent than the well-described Au25GSH18 NCs in the near-infrared (NIR) region and present significantly stronger tumor uptake and retention illustrated by an in vivo s.c. tumor-to-skin ratio of 1.8 measured by non-invasive optical imaging and an ex vivo tumor-to-muscle of 6.1. This work highlights the pivotal role of surface coating in designing optimum Au NC candidates for cancer treatment.


Asunto(s)
Medios de Contraste , Glioblastoma/diagnóstico por imagen , Oro , Nanopartículas del Metal , Neoplasias Experimentales/diagnóstico por imagen , Tomografía Óptica , Animales , Línea Celular Tumoral , Medios de Contraste/química , Medios de Contraste/farmacología , Femenino , Oro/química , Oro/farmacología , Humanos , Nanopartículas del Metal/química , Nanopartículas del Metal/uso terapéutico , Ratones , Ratones Desnudos , Tomografía por Rayos X
14.
Appl Opt ; 57(6): 1315-1320, 2018 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-29469828

RESUMEN

Short-wavelength imaging, spectroscopy, and lithography scale down the characteristic length-scale to nanometers. This poses tight constraints on the optics finishing tolerances, which is often difficult to characterize. Indeed, even a tiny surface defect degrades the reflectivity and spatial projection of such optics. In this study, we demonstrate experimentally that a Hartmann wavefront sensor for extreme ultraviolet (XUV) wavelengths is an effective non-contact analytical method for inspecting the surface of multilayer optics. The experiment was carried out in a tabletop laboratory using a high-order harmonic generation as an XUV source. The wavefront sensor was used to measure the wavefront errors after the reflection of the XUV beam on a spherical Ru/B4C multilayer mirror, scanning a large surface of approximately 40 mm in diameter. The results showed that the technique detects the aberrations in the nanometer range.

15.
Nat Commun ; 7: 13688, 2016 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-27905401

RESUMEN

Chirped pulse amplification in optical lasers is a revolutionary technique, which allows the generation of extremely powerful femtosecond pulses in the infrared and visible spectral ranges. Such pulses are nowadays an indispensable tool for a myriad of applications, both in fundamental and applied research. In recent years, a strong need emerged for light sources producing ultra-short and intense laser-like X-ray pulses, to be used for experiments in a variety of disciplines, ranging from physics and chemistry to biology and material sciences. This demand was satisfied by the advent of short-wavelength free-electron lasers. However, for any given free-electron laser setup, a limit presently exists in the generation of ultra-short pulses carrying substantial energy. Here we present the experimental implementation of chirped pulse amplification on a seeded free-electron laser in the extreme-ultraviolet, paving the way to the generation of fully coherent sub-femtosecond gigawatt pulses in the water window (2.3-4.4 nm).

17.
Sci Rep ; 6: 18970, 2016 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-26733106

RESUMEN

Does the excitation of ultrafast magnetization require direct interaction between the photons of the optical pump pulse and the magnetic layer? Here, we demonstrate unambiguously that this is not the case. For this we have studied the magnetization dynamics of a ferromagnetic cobalt/palladium multilayer capped by an IR-opaque aluminum layer. Upon excitation with an intense femtosecond-short IR laser pulse, the film exhibits the classical ultrafast demagnetization phenomenon although only a negligible number of IR photons penetrate the aluminum layer. In comparison with an uncapped cobalt/palladium reference film, the initial demagnetization of the capped film occurs with a delayed onset and at a slower rate. Both observations are qualitatively in line with energy transport from the aluminum layer into the underlying magnetic film by the excited, hot electrons of the aluminum film. Our data thus confirm recent theoretical predictions.

18.
Opt Express ; 23(14): 17665-74, 2015 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-26191828

RESUMEN

We present a setup for complete characterization of femtosecond pulses generated by seeded free-electron lasers (FELs) in the extreme-ultraviolet spectral region. Two delayed and spectrally shifted replicas are produced and used for spectral phase interferometry for direct electric field reconstruction (SPIDER). We show that it can be achieved by a simple arrangement of the seed laser. Temporal shape and phase obtained in FEL simulations are well retrieved by SPIDER reconstructions, allowing to foresee the implementation of this diagnostics tool on existing and future sources. This will be a significant step towards an experimental investigation and control of FEL spectral phase.

19.
Opt Lett ; 38(20): 4011-4, 2013 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-24321908

RESUMEN

The wavefront of an injection-seeded soft x-ray laser beam generated by amplification of high-harmonic pulses in a λ=18.9 nm molybdenum plasma amplifier was measured by a Hartmann wavefront sensor with an accuracy of λ/32 root mean square (rms). A significant improvement in wavefront aberrations of 0.51±0.03λ rms to 0.23±0.01λ rms was observed as a function of plasma column length. The variation of wavefront characteristic as a function time delay between the injection of the seed and peak of soft x-ray amplifier pump was studied. The measurements were used to reconstruct the soft x-ray source and confirm its high peak brightness.

20.
Opt Lett ; 37(20): 4341-3, 2012 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-23073456

RESUMEN

To date, plasma-based soft x-ray lasers have demonstrated experimentally 1 µJ, 1 ps (1 MW) pulses. This Letter reports extensive study using time-dependant Maxwell-Bloch code of seeding millimeter scale plasmas that store more than 100 mJ in population inversion. Direct seeding of these plasmas has to overcome very strong amplified spontaneous emission (ASE) as well as prevent wake-field amplification. Below 100 nJ injected energy, seed produces pulses with picosecond duration. To overcome this limitation, a new scheme has been studied, taking advantage of a plasma preamplifier that dramatically increases the seed energy prior to entering the main plasma amplifier leading to ASE and wake-free, fully coherent 21.6 µJ, 80 fs pulses (0.27 GW).


Asunto(s)
Fenómenos Ópticos , Gases em Plasma , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA